• Title/Summary/Keyword: Capacity of Anchorage

Search Result 142, Processing Time 0.035 seconds

Earthwork Volume Calculation of Anchorage Underground Capacity Using Laser Scanner (레이저스캐너를 이용한 앵커리지 지하공동의 토공량 산정)

  • Choi, Seok-Keun;Kim, Dong-Yeun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.18 no.3
    • /
    • pp.21-27
    • /
    • 2010
  • When the capacity of underground caverns' structures is measured, a general surveying is difficult to decide an accurate section of irregular shape and a photographic surveying has problems on picture acquisition due to underground dusts, noise and lighting conditions, etc. The laser scanner system is being much used for 3-dimensional modeling such as topography, planimetric features and structures, etc. without a target by measuring arriving time of a laser pulse reflected after scanning the laser pulse and calculating space coordinates of the reflection position. Accordingly, the present research carried out section and earthwork volume measurement of a tunnel by using a laser scanner in underground anchorage excavation work that a bridge construction is being executed.

Experimental Study of Friction Pendulum System to Improve the Seismic Capacity of Transformer (변압기의 내진성능 향상을 위한 마찰진자 면진장치의 시험 연구)

  • Jang, Jung-Bum;Kim, Jeong-Ki;Hwang, Kyeong-Min;Ham, Kyung-Won;Park, Jin-Wan;Lee, Chan-Wook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.1-8
    • /
    • 2008
  • Friction pendulum system is developed to prevent the damage of transformer, which is the most important among the electric power facilities, due to the earthquake and its seismic capacity is verified through the shaking table test. The applicability of friction pendulum system is confirmed as test results of compressive capacity test and friction test. Especially, as a result of shaking table test with a large scale transformer model, friction pendulum system gives to the reduction of maximum response acceleration by 30% at anchorage of transformer and 59% at the top of porcelain bushing comparing with the existing anchorage type. In addition to the reduction of maximum response acceleration, natural frequency of transformer is shifted to long period due to the friction pendulum system. In case that friction pendulum system is applied to the transformer, the damage of transformer can be prevented effectively under the earthquake.

Ductility of carbon fiber-reinforced polymer (CFRP) strengthened reinforced concrete beams: Experimental investigation

  • Kim, Sang Hun;Aboutaha, Riyad S.
    • Steel and Composite Structures
    • /
    • v.4 no.5
    • /
    • pp.333-353
    • /
    • 2004
  • Strength of reinforced concrete beams can easily be increased by the use of externally bonded CFRP composites. However, the mode of failure of CFRP strengthened beam is usually brittle due to tension-shear failure in the concrete substrate or bond failure near the CFRP-Concrete interface. In order to improve the ductility of CFRP strengthened concrete beams, critical variables need to be investigated. This experimental and analytical research focused on a series of reinforced concrete beams strengthened with CFRP composites to enhance the flexural capacity and ductility. The main variables were the amount of CFRP composites, the amount of longitudinal and shear reinforcement, and the effect of CFRP end diagonal anchorage system. Sixteen full-scale beams were investigated. A new design guideline was proposed according to the effects of the above-mentioned variables. The experimental and analytical results were found to be in good agreement.

Strengthening of RC beams with prefabricated RC U cross-sectional plates

  • Demir, Ali;Tekin, Muhammed;Turali, Tezcan;Bagci, Muhiddin
    • Structural Engineering and Mechanics
    • /
    • v.49 no.6
    • /
    • pp.673-685
    • /
    • 2014
  • The topic of this study is to strengthen cracked beams with prefabricated RC U cross-sectional plates. The damaged beams were repaired by epoxy based glue. The repaired beams were strengthened using prefabricated plates. The strengthening plates were bonded to the bottom and side faces of the beams by anchorage rods and epoxy. The strengthened beams were incrementally loaded up to maximum load capacities. The experimental results were satisfactory since the load carrying capacities of damaged beams were increased approximately 76% due to strengthening. It was observed that strengthening plates had a dominant effect on the performance of beams in terms of both the post-elastic strength enhancement and the ductility. The experimental program was supported by a three-dimensional nonlinear finite element analysis. The experimental results were compared with the results obtained from the beam modeled with ANSYS finite element program.

An Experimental Study on the Structural Behavior of Reinforced Concrete Continuous Deep Beams Using Welded Deformed Wire Fabric as Shear Reinforcements (이형 용접철망을 전단철근으로 사용한 철근콘크리트 연속 깊은 보의 구조적 거동에 대한 실험적 연구)

  • Yang Keun-Hyeok;Chung Heon-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.95-98
    • /
    • 2005
  • The objective of this experimental study was to understand the structural behavior of reinforced concrete continuous deep beams with welded deformed wire fabric(WWF) as shear reinforcement. The structural behavior of deep beams reinforced with WWF was compared with that of deep beams reinforced with orthogonal shear reinforcement which had standard anchorage corresponding to ACI 318-02. Test results showed that the load transferring capacity and the control of splitting cracks in the strut of WWF were almost as effective as those of orthogonal shear reinforcement with standard anchorage.

  • PDF

Behavior of Mechanical Anchorage Surface-Embedded in Concrete for Post-tensioning CFRP Strips (외부 프리스트레스트 탄소섬유판 정착장치의 콘크리트에 대한 정착성능)

  • You, Young-Chan;Choi, Ki-Sun;Park, Young-Hwan;Park, Jong-Sup;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.226-229
    • /
    • 2006
  • Strengthening with externally post-tensioned CFRP strips is more effective in increasing load carrying capacity of existing structures as well as reducing crack width and deflection. This study developed concrete embedded anchorages system for externally post-tensioned CFRP strips, and carried out experimental study to verify anchoring performance quantitatively. Through experimental results, anchoring strength of concrete embedded anchorage were quantified into shear strength of anchor bolt, bearing strength of concrete at the front of anchor plate and bond strength between anchor plate and concrete surface. In addition, overall anchoring performances according to combination of each unit force are examined in this study.

  • PDF

Experimental Study on the Bond[ Behavior with Concrete Surface Preparation. and Anchorage Type of CFRP (콘크리트 표면처리와 CFRP 단부정착 방법에 따른 부착특성실험)

  • 유영준;조정래;정우태;박종섭;박영환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.579-584
    • /
    • 2003
  • For strengthening deteriorated concrete structures, externally bonded FRP sheets or plates using epoxy resins are widely used. For the external FRP composites to be effective in improving the performance of the structure, bond between FRP composites and concrete is required. In general, the most frequently observed failure mode in FRP strengthened concrete structures is debonding failure at the interfacial section between FRP and concrete. Therefore, it is very important to find out the interfacial behavior properties. This paper presents experimental results of the relationship of concrete and FRP sheet for some conditions including concrete compressive strength, concrete surface preparation to observe the bond behavior between concrete and FRP sheet and various anchorage types to increase the bond capacity of FRP sheet.

  • PDF

Cyclic-Leading Tests of RC Exterior Beam-Column Joints with Non-Seismic Detailing (비내진 상세를 가진 RC 외부접합부의 반복 횡하중 실험)

  • Cha, Byung-Gi;Ko, Dong-Woo;Woo, Sung-Woo;Lee, Han-Seon
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.11-16
    • /
    • 2003
  • The objective of this study is to clarify the seismic capacity and the characteristics in the hysteretic behavior of RC structures with non-seismic detailing. To do this, an exterior beam-column subassemblage was selected from a ten story RC building and six 1/3-scale specimens were manufactured with three variables; (1) with and without slab, (2) upward and downward direction of anchorage for the bottom bar in beams, and (3) with and without hoop bars in the joint region. The test results have shown that (1) the existence of slab increased the strength in positive and negative moment, 25% and 52%, respectively; (2) the Korean practice of anchorage (downward and 25 $d_{b}$ anchorage length) caused the 8% reduction of strength and the early strength degradation in comparison with the case of seismic details; and (3) the existence of hoop bars in the joint region shows significant role in preventing the pull-out.t.

Influence of Anchorage of T-Plate on the Seismic Performance of RC Columns Strengthened with Unbounded Wire Rope Units (와이어로프 기반 비부착 보강된 RC 기둥의 내진거동에 대한 T형 강판 정착의 영향)

  • Sim, Jae-Il;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.133-140
    • /
    • 2010
  • Five strengthened columns and an unstrengthened column were tested under constant axial load and cyclic lateral loads to examine the seismic performance of the unbounded strengthening procedure using wire ropes and T-plates. Main variables considered were the presence of mortar cover for strengthening steel element and anchorage method of T-plate. Test results clearly showed that T-plates having a proper anchorage contribute to transfer of applied moment as well as enhancement of ductility of reinforced concrete columns. However, T-plate not anchored fully into a column base can seldom transfer the externally applied moment, though it highly improves the ductility of column. The presence of mortar cover for strengthening steel elements is significantly effective in enhancing the initial stiffness and flexural capacity of the strengthened columns, but has an adversely effect on enhancing the ductility. The ultimate moment strength predicted from the extended section laminae method in better agreement with test results compared with predictions obtained using stress black specified in ACI 318-05.

Fracture behavior of Cast-in-place Headed Anchors to Concrete (콘크리트 CIP 앵커시스템의 파괴 거동에 관한 연구)

  • Park, Sung-Gyun;Kim, Ho-Seop;Yoon, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.3
    • /
    • pp.141-152
    • /
    • 2001
  • This paper presents the evaluation of behavior and the prediction of tensile capacity of anchors that can cause a failure of the concrete on the basis of the design for anchorage. Tests of cast-in-place headed anchors, domestically manufactured and installed in uncracked and unreinforced concrete member are conducted to test the effected of embedment length and edge distance. The failure modes and the load-deformation responses of the anchors are discussed and then the concrete failure data are compared with capacities by the two present methods : the 45 degree cone method of ACI 349, 318 and the concrete capacity design (COD) method. Differences between the results by test and by two prediction methods are analyzed Finite Element Method (FEM).

  • PDF