• Title/Summary/Keyword: Capacity Limitation

Search Result 362, Processing Time 0.033 seconds

A Novel Multi-Function PV Micro-Inverter with an Optimized Harmonic Compensation Strategy

  • Zhu, Guofeng;Mu, Longhua;Yan, Junhua
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2284-2293
    • /
    • 2016
  • With the rapid development of clean energy, photovoltaic (PV) generation has been utilized in the harmonic compensation of power systems. This paper presents a novel multi-function PV micro-inverter with three stages (pseudo-two-stage). It can inject active power and compensate harmonic currents in the power grid at the same time. In order to keep the micro-inverter working under the maximum allowable output power, an optimized capacity limitation strategy is presented. Moreover, the harmonic compensation can be adjusted according to the customized requirements of power quality. Additionally, a phase shedding strategy in the DC/DC stage is introduced to improve the efficiency of parallel Boost converters in a wide range. Compared with existing capacity limitation methods, the proposed strategy shows better performance and energy efficiency. Simulations and experiments verify the feasibility of the micro-inverter and the effectiveness of the strategy.

A Digital System Modelling for Narrow Band ISDN and A Decision Methodology of Channel Capacity Limitation (협대역 ISDN을 위한 디지털 시스템 모델링과 통신로 용량의 한계 결정)

  • 이종현;성태경;신용옥
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.6
    • /
    • pp.591-597
    • /
    • 1988
  • In this paper, we have studied a channel capacity affected by noise which produces burst errors in the ISDN(approx 140Kbps) data transmission using a existing PSTN. First, a digital communication system model to apply a subscriber line to a narrow band ISDN channel is presented. Second, the decision methodology of a channel capacity limitation whether the pdf of the noise generated by a waveform synthesizer is Pisson or Laplacian is described. As a result of the simulation, we have obtained that the Poission distributed noise is approached to the Guassian rather than the Laplacian under the same SNR condition.

  • PDF

Analysis of the Heat Transport Capacity of a Axial Grooved Heat Pipe for Solar Collector (태양열 집열기용 히트파이프의 열전달 특성에 대한 해석)

  • Chung, Kyung-Taek;Bae, Chan-Hyo;Suh, Jeong-Se;Kim, Byeong-Gi
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.317-322
    • /
    • 2005
  • This study is aimed to analyze the effects of heat pipe shape on the heat transfer in solar collector with a axial grooved heat pipe. In the design of a heat pipe. two of the most important criteria to be met are the operating temperature range and the maximum heat transport capacity, When the operating temperature range is known and the working fluid has been selected, the maximum heat transport capacity depends strongly on capillary pressure and liquid flow. The heat transport capacity of the heat pipe will depend on the geometry of the heat pipe, the wick structure. the vapor channel shape. groove number. cooling temperature. condenser length and pipe diameter. So various shapes are used for mathematical models of two-phase flow in grooved heat pipe. From the results. the adequate groove shape and scale are presented by considering the heat transport and capillary limitation.

  • PDF

The analysis of the conversive limitation of electric energy for the gate turn on thyristor inverter (Gate turn on thyristor 역변환장치의 변환전력한계치에 대하여)

  • Hee Yung Chun
    • 전기의세계
    • /
    • v.17 no.2
    • /
    • pp.6-10
    • /
    • 1968
  • The conversive limitation of electric energy for the thyristor inverter is analysed under the boundary conditions which the term of a negative inverse voltage is longer than that of the turn off time of the thyristor under commutation. It is clear that the maximum electric energy conversion is affected by the turn off time of the thyristor, the reactance of a commutation reactor, the capacity of a commutation condenser and the voltage of Direct current source. It is useful for design the thyrister invertor and the motor speed control to apply the above conclusion.

  • PDF

A Study on Riding Capacity of Railway Vehicles for Military Passengers (철도 객차별 군 인원 탑승능력 판단 연구)

  • Oh, Sukmun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.129-136
    • /
    • 2017
  • This paper aims to establish a guideline for ridership capacity of different rail vehicles for military passengers. Previous guideline is limited only to a Mungungwha(hauled by diesel locomotive) vehicle, but this paper expands the limitation to ITX- Saemaeul and urban rail vehicles classified to Electric Motivated Unit(EMU). The guideline considers both with and without personal armor conditions, and based on repetitive ridership experiments. The experiments are designed under considerations of the required number of soldiers for the sample spaces of the different rail vehicles. Moreover, the design tries to establish a concept of optimal capacity additionally to a traditional limiting ridership capacity. In order to do this, ridership comfort is questioned to participant soldiers repetitively over the experiments and all answers of them are surveyed as a results of it. The results of the experiments presented by this paper can be referenced to establish a new guideline on ridership capacity for Korean army.

A Development of Environmental Capacity Estimation Model Using the National Environmental Assessment Indicators (국토환경성평가 지표를 이용한 환경용량 산정모델 개발)

  • Lee, Chong-Soo;Lee, Woo-Kyun;Jeon, Seong-Woo
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.6
    • /
    • pp.385-394
    • /
    • 2006
  • Land resources should be managed not only for human utilizations but also for environmental preservation. Based on that, environmental capacity should be estimated in both environmental and developmental ways. This study was performed for developing an estimation model for relative environmental capacity, considering both Development Tolerance Index(DTI), which shows environmental and ecological conservation value and is based on national environmental assessment indicators of the Korea Ministry of Environment, and Development Attractiveness Index(DAI), which shows topographical characteristics and geographical accessibility. The relative environmental capacity in this study can be helpful to coping with the conflict in planning and managing the use of land resources. The relative environmental capacity in this study, however, did not include either environmental or ecological sensitivity of land resources. This limitation should be solved through further research.

The detection of collapsible airways contributing to airflow limitation (기류 제한에 영향을 미치는 허탈성 기도의 분석)

  • Kim, Yun Seong;Park, Byung Gyu;Lee, Kyong In;Son, Seok Man;Lee, Hyo Jin;Lee, Min Ki;Son, Choon Hee;Park, Soon Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.558-570
    • /
    • 1996
  • Background : The detection of Collapsible airways has important therapeutic implications in chronic airway disease and bronchial asthma. The distinction of a purely collapsible airways disease from that of asthma is important because the treatment of the dormer may include the use of pursed lip breathing or nasal positive pressure ventilation whereas in the latter, pharmacologic approaches are used. One form of irreversible airflow limitation is collapsible airways, which has been shown to be a Component of asthma or to emphysema, it can be assessed by the volume difference between what exits the lung as determined by a spirometer and the volume compressed as measured by the plethysmography. Method : To investigate whether volume difference between slow and forced vital Capacity(SVC-FVC) by spirometry may be used as a surrogate index of airway collapse, we examined pulmonary function parameters before and after bronchodilator agent inhalation by spirometry and body plethysmography in 20 cases of patients with evidence of airflow limitation(chronic obstructive pulmonary disease 12 cases, stable bronchial asthma 7 cases, combined chronic obstructive pulmonary disease with asthma 1 case) and 20 cases of normal subjects without evidence of airflow limitation referred to the Pusan National University Hospital pulmonary function laboratory from January 1995 to July 1995 prospectively. Results : 1) Average and standard deviation of age, height, weight of patients with airflow limitation was $58.3{\pm}7.24$(yr), $166{\pm}8.0$(cm), $59.0{\pm}9.9$(kg) and those of normal subjects was $56.3{\pm}12.47$(yr), $165.9{\pm}6.9$(cm), $64.4{\pm}10.4$(kg), respectively. The differences of physical characteristics of both group were not significant statistically and male to female ratio was 14:6 in both groups. 2) The difference between slow vital capacity and forced vital capacity was $395{\pm}317ml$ in patients group and $154{\pm}176ml$ in normal group and there was statistically significance between two groups(p<0.05). Sensitivity and specificity were most higher when the cut-off value was 208ml. 3) After bronchodilator inhalation, reversible airway obstructions were shown in 16 cases of patients group, 7 cases of control group(p<0.05) by spirometry or body plethysmography d the differences of slow vital capacity and forced vital capacity in bronchodilator response group and nonresponse group were $300.4{\pm}306ml$, $144.7{\pm}180ml$ and this difference was statistically significant. 4) The difference between slow vital capacity and forced vital capacity before bronchodilator inhalation was correlated with airway resistance before bronchodilator(r=0.307 p=0.05), and the difference between slow vital capacity and forced vital capacity after bronchodilator was correlated with difference between slow vital capacity and forced vital capacity(r=0.559 p=0.0002), thoracic gas volume(r=0.488 p=0.002) before bronchodilator and airway resistance(r=0.583 p=0.0001), thoracic gas volume(r=0.375 p=0.0170) after bronchodilator, respectively. 5) The difference between slow vital capacity and forced vital capacity in smokers and nonsmokers was $257.5{\pm}303ml$, $277.5{\pm}276ml$, respectively and this difference did not reach statistical significance(p>0.05). Conclusion : The difference between slow vital capacity and forced vital capacity by spirometry may be useful for the detection of collapsible airway and may help decision making of therapeutic plans.

  • PDF

Estimating Environmental Carrying Capacity of Seoul Metropolitan Area Using System Dynamics and Box Model

  • Moon, Taehoon
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.10a
    • /
    • pp.20-36
    • /
    • 2001
  • The purpose of this paper is estimating environmental carving capacity of Seoul Metropolitan Area for a sustainable city management using system dynamics model. A sustainable development requires a society to define sustainability constraints or environmental limits, environmental carving capacity. Environmental carving capacity can be defined as the level of human activity which a region can sustain at an acceptable quality of life level. This concept of environmental carving capacity has several important application to sustainable city planning and management. If the limitation of a human activity can be supported by a scientific data on carving capacity, the resulting decision and actions could more easily win public support for a sustainable development. However, one of the key issues is how to operationalize the carving capacity. In this paper, the environmental carving capacity was operationalized as a maximum number of industry structure, population, and housing that can sustain certain level of environmental quality of Seoul Metropolitan Area. The model developed in this paper consisted off sectors: population, housing, industry, land, and environmental sector. The model limits its main focus on the NO$_2$level of ambient air of Seoul. Carving capacity Seoul Metropolitan Area was estimated by figuring out the maximum number of population, industry structure, housing at an equilibrium point that sustain a desirable NO$_2$level. Based on the model estimation, several policy implications for a sustainable city management was discussed.

  • PDF

Capacity Firming for Wind Generation using One-Step Model Predictive Control and Battery Energy Storage System

  • Robles, Micro Daryl;Kim, Jung-Su;Song, Hwachang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.2043-2050
    • /
    • 2017
  • This paper presents two MPC (Model Predictive Control) based charging and discharging algorithms of BESS (Battery Energy Storage System) for capacity firming of wind generation. To deal with the intermittency of the output of wind generation, a single BESS is employed. The proposed algorithms not only make the output of combined systems of wind generation and BESS track the predefined reference, but also keep the SoC (State of Charge) of BESS within its physical limitation. Since the proposed algorithms are both presented in simple if-then statements which are the optimal solutions of related optimization problems, they are both easy to implement in a real-time system. Finally, simulations of the two strategies are done using a realistic wind farm library and a BESS model. The results on both simulations show that the proposed algorithms effectively achieve capacity firming while fulfilling all physical constraints.

A Study on the Fuzzy ELDC of Composite Power System Based on Probabilistic and Fuzzy Set Theories

  • Park, Jaeseok;Kim, Hongsik;Seungpil Moon;Junmin Cha;Park, Daeseok;Roy Billinton
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.3
    • /
    • pp.95-101
    • /
    • 2002
  • This paper illustrates a new fuzzy effective load model for probabilistic and fuzzy production cost simulation of the load point of the composite power system. A model for reliability evaluation of a transmission system using the fuzzy set theory is proposed for considering the flexibility or ambiguity of capacity limitation and overload of transmission lines, which are subjective matter characteristics. A conventional probabilistic approach was also used to model the uncertainties related to the objective matters for forced outage rates of generators and transmission lines in the new model. The methodology is formulated in order to consider the flexibility or ambiguity of load forecasting as well as capacity limitation and overload of transmission lines. It is expected that the Fuzzy CMELDC (CoMposite power system Effective Load Duration Curve) proposed in this study will provide some solutions to many problems based on nodal and decentralized operation and control of an electric power systems in a competitive environment in the future. The characteristics of this new model are illustrated by some case studies of a very simple test system.