• Title/Summary/Keyword: Capacity Design

Search Result 5,647, Processing Time 0.035 seconds

A Study on Evaluation of Performance Point for the Latticed Dome (래티스 돔의 성능점 산정에 관한 연구)

  • Han Sang-Eul;Lee Sang-Joo;Gan Eun-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.317-324
    • /
    • 2006
  • Performance-based design concept is needed to evaluate the seismic capacity of building. In this study, the method estimating the performance point of the spatial structures based on capacity spectrum method (CSM) is proposed. And for efficient evaluation for the performance point of the spatial structures, the algorithm to convert spatial structural system to ESDOF system is simulated Its efficiency is confirmed by comparing with time history analysis of full model. And dynamic behaviors of spatial structures are examined by using this method. At last, evaluation of structural performance according to variation of stiffness after plastic deformation on the substructures is carried out.

  • PDF

A Study on Capacity Design of Energy Storage System for Urban Transit System (도시철도시스템용 에너지저장시스템 용량설계에 관한 연구)

  • Lee, Han-Min;Kim, Gil-Dong;Lee, Chang-Mu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.697-700
    • /
    • 2007
  • Six thousands of vehicles are operated on Korean urban transit system. 95% of them have regeneration system. Especially, the VVVF-Inverter vehicle has a merit of the highest regeneration rate. Therefore, the energy storage system is needed to be developed to use regeneration energy when the vehicle is braking. Therefore, Measuring regeneration energy in the substation need to know how much regeneration energy occurs, how much capacity of energy storage system is needed. After measuring regeneration energy, we design the capacity of energy storage system.

  • PDF

Fracture Behavior of Cast-in-place Headed Anchors to Concrete (콘크리트 CIP 앵커시스템의 파괴거동에 관한 연구)

  • 박성균;김호섭;윤영수;김상윤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.491-496
    • /
    • 2000
  • This paper presents the evaluation of behavior and the prediction of tensile capacity of anchors that fail concrete, as the design basis for anchorage. Tests of cast-in-place headed anchors, domestically manufactured and installed in uncracked, unreinforced concrete are performed to investigate the behavior of single anchors and multiple anchors with the consideration of various embedment lengths and edge distances. The failure mode and the load-deformation response of these anchors are discussed and the concrete failure dta are then compared with capacity predictions by the two existing methods : the 45 degree cone method of ACI 349, 318 and the concrete capacity design (CCD) method. Discrepancies between the test results and these two prediction methods, FEM analysis are assessed.

  • PDF

A Numerical Study on the effect of Volute Geometry on the Performance of Centrifugal Pump (볼류트 형상이 원심 펌프의 성능에 미치는 영향에 대한 수치 해석적 연구)

  • Kim, Deok-Su;Choi, Young-Seok;Jeon, Sang-Gyu;Yoon, Joon-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.497-502
    • /
    • 2005
  • In this study. the effect of volute area distribution on the performance of a centrifugal pump were numerically studied using a commercial CFD code. To reduce the shutoff head, maintaining head and efficiency at a design flow rate. the flat head-capacity characteristic curves in which the head varies only slightly with capacity from shutoff to design capacity are frequently required. In order to control the shutoff head of a pump, several volute cross-sectional area distributions were proposed as a main parameter with the same impeller geometry. The calculation results show that the slope of the performance characteristic curve of the centrifugal pump can be controlled by modifying the area distribution from volute tongue to volute outlet with fixed volute outlet area and also varied volute outlet area.

  • PDF

Feasibility Study on Design of Thrust Bearing for Micro Gas Turbine Generator (초소형 가스 터빈 제너레이터용 스러스트 베어링의 설계 및 타당성에 관한 연구)

  • 이용복;곽현덕;김창호;장건희
    • Tribology and Lubricants
    • /
    • v.17 no.6
    • /
    • pp.467-475
    • /
    • 2001
  • Feasibility study of gas-lubricated bearing in micro gas turbine was performed. Based on Reynolds equation, finite difference method with coupled boundary was developed to analyze bearing characteristics, such as load capacity, mass flow rates and stiffness. By the bearing force and mass flow rates analysis with the variation of supply pressure, bearing clearance and capillary radius, acceptable range of design parameters were suggested in terms of load capacity and stiffness of bearings. Additionally, coupled boundary effect on pressure distribution was investigated and it is stated that coupling could reduce an excitation force due to narrow pressure distribution.

Feasibility Study on Design of Thrust Bearing for Micro Gas Turbine/Generator (초소형 가스 터빈/제너레이터용 스러스트 베어링의 설계 및 타당성에 관한 연구)

  • 곽현덕;이용복;김창호;장건희
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.273-281
    • /
    • 2001
  • Feasibility study of gas-lubricated bearing in micro gas turbine was performed. Based on Reynolds equation, finite difference method with coupled boundary was developed to analyze bearing characteristics, such as load-carrying capacity, mass flow rates and stiffness. By the bearing force and mass flow rates analysis with the variation of supply pressure, bearing clearance and capillary radius, acceptable range of design parameters were suggested in terms of load capacity and stiffness of bearings. Additionally, coupled boundary effect on pressure distribution was investigated and it is stated that coupling could reduce all excitation force due to narrow pressure distribution.

  • PDF

Experience for development and capacity certification of safely relief valves (안전방출밸브 개발과 용량인증 사례)

  • Kim, Chil-Seong;No, Hui-Seon;Kim, Gang-Tae;Kim, Ji-Heon;Kim, Jong-Su
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.492-500
    • /
    • 2004
  • The purpose of this study is localization of safety relief valves fur Nuclear Service through technical development with overall design, fabrication, inspection, capacity certification test and functional qualification test of safety relief valves in accordance with KEPIC MN Code(or ASME Sec.III ). The safely relief valve is the important equipment used to protect the pressure vessel, the steam generator and the other pressure facility from overpressure by discharging the operating medium when the pressure of system is reaching the design pressure of the system. But we're depending on technology of the other country up to the present time. Because we don't have our own technologies, we have been spent the great time and money on installing and repairing safety relief valve at nuclear power plant. Therefore we have to achieve the development of safety relief valves for Nuclear Service with our own technologies.

  • PDF

Effect of Volute Area Distributions on the Performance Characteristic Curve of a Centrifugal Pump (볼류트 단면적 변화가 원심펌프의 성능곡선에 미치는 영향)

  • Kim, Deok-Su;Lee, Kyoung-Young;Yoon, Joon-Yong;Choi, Young-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.558-563
    • /
    • 2005
  • In this paper, the effect of volute area distribution on the performance characteristic curve of a centrifugal pump were numerically studied using a commercial CFD code. To reduce the shutoff head, maintaining head and efficiency at a design flow rate, the flat head-capacity characteristic curves in which the head varies only slightly with capacity from shutoff to design capacity are frequency required. In order to control the shutoff head of a pump, several volute area distributions were proposed as a main parameter with the same impeller geometry. The calculation results show that the characteristic curve of a centrifugal pump can be controlled by modifying the area distribution with the same volute outlet area.

  • PDF

Assessment of the New Capacity and LOS of Transfer Facilities in the High-speed Railway Stations (고속철도역 환승시설 용량 및 서비스수준 산정 방안)

  • Kim, Jong-Hae;Kim, Si-Gon;Lee, Kyung-No
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1374-1384
    • /
    • 2008
  • The Design manual for adjusting the capacity and LOS of facilities has been shared in urban railways and high-speed railway stations. However, the pattern of urban railways users and those of high-speed railway users are different from each other. For an example, the high-speed railway users tend to carry voluminous luggages and the transportation disadvantaged such as children and the elderlies. Accordingly, we see that the scale of facilities and the station itself should be constructed differently. The transfer facilities in the high-speed railway stations are classified widely into walking assisting facilities and convenient facilities. We invented the concept of PME(Pedestrian Moving Equivalent) and PWE(Pedestrian Waiting Equivalent)for the spatial calculation of those who are with wheeled luggages, back packs, and children to reflect the uniqueness of users in high-speed railway stations. These equivalents have been applied to the design of the facilities to asses the new Capacity and LOS that are users' favored.

  • PDF

A Study on Lateral Bearing Capacity of PHC Piles Driven Vertically in Decomposed Granite and Clayey Soil (화강토와 점토지반에 연직으로 타입된 PHC말뚝의 수평지지력에 관한 연구(지반공학))

  • 문영민;이문수;이대재
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.466-470
    • /
    • 2000
  • Recently, the calculation of horizontal bearing capacity of piles foundation has been considered very important for earthquake or wind resistant design in Korea. This study deals with the lateral resistance of PHC pile instead of vertical capacity for earthquake resistant design as well as wind. As case study, the prediction values were compared with measured ones based on ASTM. During this research, Matlock & Reese, Davisson & Gill, Broms and Chang's methods were selected in calculating prediction of lateral resistance of PHC piles. In decomposed granite and clayey soils, The result showed that prediction values proposed by Matlock & Reese(Davisson & Gill), Chang and Broms were smaller values than real values. four proposed methods by Matlock & Reese(Davisson & Gill) and Chang based on lateral deflection and Broms by ultimate lateral resistance turned out valid in view of engineering practice.

  • PDF