• Title/Summary/Keyword: Cancer Patients's Discharge

Search Result 42, Processing Time 0.021 seconds

An Analysis of Referrals, Nursing Diagnosis, and Nursing Interventions in Home Care - Wonju Christian Hospital Community Health Nursing Service - (가정간호 기록지 분석 - 원주기독병원 가정간호 보건활동을 중심으로 -)

  • Suh, Mi-Hae;Huh, Hae-Kyung
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.3
    • /
    • pp.53-66
    • /
    • 1996
  • Home Health Care is one part of the total health care system. It includes health care services that link the hospital to the community. While it is important for early discharge patients, home care is also important for people with chronic illnesses or handicapping conditions. In 1989 the Korean government passed a law that opened the way for formal development of home health care services beginning with education programs to certify nurses for home care, and then demonstration home care services. Part of the mandate of the demonstration projects was evaluation of home care services. This study was done in order to provide basic data that would contribute to the development of records that could be used for evaluation through a retrospective audit and to examine the care that had been given in Home Care at Wonju Christian Hospital over a twenty year period from 1974 to 1994. The purposes of the study were : to identify to characteristics of the clients who had received home care, to identify the reasons for client referrals, to identify the nursing problems of these clients, to identify the nursing care provided to these clients, and to identify differences in these areas over the twenty year period. The study was a descriptive study involving a retrospective audit of the client records. Demographic data on all clients were included : 4,171 clients from 2,564 families. Data on referrals, nursing diagnosis and nursing interventions were from even numbered records which had a patient problem list included in the record, 2,801 clients, Frequencies and ANOVA were used in the analysis. The results of the study showed that the majority of the clients were from Wonju city /county. There were more women than men related to the high number of postpartum clients(1,300). The high number of postparttum clients and newborns was also evident in the age distribution. An the number of maternal-child clients decreased over the 20 years, the mean age of the clients increased significantly. Other factors also contributed to this change ; as increasing number of clients with brain injuries or with cancer, and fewer children with burns, osteomyelitis and tuberculosis. There was a decrease in the mean number of visits and mean length of coverage, reflecting a movement towards a short term acute care model. The number of new clents dropped sharply after 1985. The reasons for this are : the development of other treatment alternatives for clients, the establishment of an active wellbaby clinic, many more options plus a decreasing number of new cases of Hansen's Disase, and insurance that allows people with burns to be kept in hospital until skin grafts are healed. Socioeconomic changes have resulted in an increase in the number of cases of cancer, stroke, head injuries following car accidents, and of diabetes. Of the 2,801 client records, 2,541(60.9%) contained a written referral but for 1,802 it contained only the medical diagnosis. The number of records with a referral requesting specific nursing care was 739(29.1%). Many family members who were identified as in need of nursing care had no written referral. Analysis of the patient problem list showed that 41.9% of the enteries were nursing diagnoses. Others incuded medical diagnosis, symptoms, and plans. The most frequently used diagnoses were alteration in nutrition, less than body requirements(115 entries), alteration in skin integrity(114), knowledge deficit(111), pain(78), self-care deficit(66), and alteration in pattern of urinary elimination(50). These are reflected in the NANDA categories for which the highest number of diagnosis was in the Exchanging pattern(446), followed by Moving(178), Feeling(136) and Knowing (115). Analysis of the frequency of interventions showed that exercise and teaching about exercise was the most frequent intervention, followed by teaching concering the need for follow-up care, checking vital signs, managing nutritional problems, managing catheters, giving emotional support, changing dressings, teaching about medication, teaching (subject not specified), teaching about diet, IM and IV medications or fluid, and skin care, in that order. Recommendations included: development of a record that would allow for efficient recording of frequently used nursing diagnoses and nursing interventions: expansion of the catchment area for Home Care at Wonju Christian Hospital ; expansion of the service to provide complication prevention, rehabilitation services, and support to increase the health maintenance /health promotion of the people being served as well as providing client dentered care ; and development of a clinical record that will allow efficient data collection from records, even though the recording is done by a variety of health care providers.

  • PDF

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF