• 제목/요약/키워드: Can loss

검색결과 9,170건 처리시간 0.037초

Micro-CT analysis of LPS-induced Alveolar Bone Loss in Diabetic Mice

  • Park, Hae-Ryoung;Park, Byung-Ju
    • International Journal of Oral Biology
    • /
    • 제37권3호
    • /
    • pp.85-90
    • /
    • 2012
  • Periodontal disease induces an increased incidence of tooth loss, particularly in cases with an associated loss of alveolar bone and periodontal ligaments. In this study, alveolar bone loss was detected by micro-computed tomography (CT) following exposure to E. coli lipopolysaccharide (LPS) in a streptozotocin (STZ)-induced diabetic mouse model. A 10 mg/ml dosage of E. coli LPS was applied between the first, second and third molars of the mice three times a week for 10 weeks. The loss of periodontal ligaments and alveolar processes was then evaluated by micro-CT using two and three dimensional microstructure morphometric parameters. In the diabetic mice, E. coli LPS induced the destruction of periodontal ligaments and loss of alveolar process spaces. The distances between periodontal ligaments were significantly widened in the STZ-LPS group compared with the untreated STZ group. The 10 mg/ml exposure to E. coli LPS in the STZ mice also resulted in a significant decrease in the alveolar bone volume fraction. The results of our study suggest that alveolar bone loss can be readily detected by volumetric micro-CT analysis as an increase in the distance between periodontal ligaments and in the alveolar process length.

Accuracy of Free Space Path Loss and Matched Filter Gain Approximated by Using Passband Rectangular Pulse for Ultra Wideband Radio Systems

  • Supanakoon, Pichaya;Tanchotikul, Suchada;Tangtisanon, Prakit;Promwong, Sathaporn;Takada, Jun-Ichi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.223-226
    • /
    • 2004
  • This paper analyzes the accuracy of free space path loss and matched filter gain approximated by using a passband rectangular pulse for ultra wideband (UWB) radio systems. The example causal signal, a modulated Gaussian pulse with the same center frequency and frequency bandwidth of the passband rectangular pulse, is used to consider the accuracy. The path loss and matched filter gain of the modulated Gaussian pulse are simulated for the reference results. The UWB free space path loss is shown and is compared with that obtained from simulation and Friis' transmission formula. The UWB matched filter gain is shown and compared with simulation results. From the results, we can see that the UWB path loss formula is more accurate than the Friis' transmission formula. The results from the UWB free space path loss and matched filter gain formulas agree with the simulation. Then, these free space path loss and matched filter gain formulas approximated by using a passband rectangular pulse are appropriate for UWB system.

  • PDF

저 레이놀즈 수가 압축기 성능에 미치는 영향에 대한 수치적 연구 (Numerical Study About the Effect of the Low Reynolds Number on the Performance in an Axial Compressor)

  • 최민석;정희택;오성환;고한영;백제현
    • 대한기계학회논문집B
    • /
    • 제32권2호
    • /
    • pp.83-91
    • /
    • 2008
  • A three-dimensional computation was conducted to understand effects of the low Reynolds number on the performance in a low-speed axial compressor at the design condition. The low Reynolds number can originates from the change of the air density because it decreases along the altitude in the troposphere. The performance of the axial compressor such as the static pressure rise was diminished by the separation on the suction surface with full span and the boundary layer on the hub, which were caused by the low Reynolds number. The total pressure loss at the low Reynolds number was found to be greater than that at the reference Reynolds number at the region from the hub to 85% span. Total pressure loss was scrutinized through three major loss categories in a subsonic axial compressor such as the profile loss, the tip leakage loss and the endwall loss using Denton#s loss model, and the effects of the low Reynolds number on the performance were analyzed in detail.

석유화학산업에서의 지속적 발전을 위한 손실관리시스템 개발 (The Loss Control Management System for Continuous Improvement of the Petrochemical Industries)

  • 고재욱;임동호;유진환
    • 한국가스학회지
    • /
    • 제9권3호
    • /
    • pp.15-20
    • /
    • 2005
  • 최근에 환경안전관리는 효과성, 효율성, 우수성이라는 측면에서 사고의 손실비용을 줄이기 위하여 다양하게 접근을 하고 있다. 대부분의 기업은 산업화시대의 대량생산적인 측면에서의 생산성향상보다는 기업을 건전하게 성장시킬 수 있는 손실을 감소시키는데 초점을 맞추고 있다. 본 연구는 석유화학산업에서 기본적으로 운영하고 있는 ISO14001, OHSAS18001, PSM, Responsible Care의 기본적인 요구사항과 지속적 발전을 위하여 요구되는 사항을 분석하여, 손실을 지속적으로 관리할 수 있는 석유화학공장에서의 지속적 발전을 위한 손실관리시스템(LCMCI; the Loss Control Management system for Continuous Improvement of the Petrochemical Industries)를 개발하였다.

  • PDF

고자속밀도와 저손실 특성을 갖는 중주파수대 철심재료 개발 및 응용 (Development of Core Material with High Magnetic Induction and Low Iron Loss for Middle-Frequency Applications)

  • 조성수;한상옥
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.190-195
    • /
    • 2009
  • Thin-gauged 3% silicon steel sheets having a highly grain-oriented texture have been developed as a core material for applications of middle-frequency (400 Hz ${\sim}$ 10 kHz) devices. The newly developed sheets with a tension coating showed an excellent reduction in iron loss at 400 Hz (iron loss at 1.0 T and 400 Hz = 4.677 W/kg, iron loss at 1.5 T and 400 Hz = 9.742 W/kg) due to high magnetic induction, $B_{10}$(measured induction at 1000 A/m), of over 1.9 T. In cases of frequencies below 400 Hz, magnetic induction, $B_{10}$, of the sample plays a major role to reduce its iron loss as excitation induction increases, whereas, in case of frequency of 1 kHz, thickness dependence becomes dominant due to a lower iron loss at relatively thinner sample. The sheets with a high magnetic induction, therefore, are favorable for high excitation induction (over 1.0 T) and low excitation frequency (below 400 Hz) applications, whereas the sheets that can reduce eddy current loss by reducing thickness or domain wall width are advantageous for low excitation induction (below 1.0 T) and high excitation frequency (around 1 kHz) applications.

광섬유 접속부의 환경 변화에 따른 손실변화 연구 (A Study on the Variation of Optical Fiber Splicing Loss due to Environment)

  • 김영호;유강희
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2006년도 하계학술대회
    • /
    • pp.105-110
    • /
    • 2006
  • The most sensitive part of the installed optical cable is the optical loss variation of the splicing point according to the environmental changes. This paper presents the details of the experimental results of the external environmental changes on optical loss, such as bending, temperature variation, temperature variation after water osmosis and variation. Through the bending test of optical fiber, rapid increase of optical loss was measured within the diameter of 30mm. The result of optical loss variation within the temperature range of $-30^{\circ}C{\sim}60^{\circ}C$ is less than 0.02dB. It was confirmed that the maximum optical loss increased up to 0.2dB in case of water osmosis within the temperature range of $-40^{\circ}C{\sim}80^{\circ}C$. There is small optical loss variation of 0.01dB under the 1mm vibration test. The experimental results of this paper can be used as the reference data for the design of the optical fiber cable splicing enclosure to protect the optical loss variation due to environmental changes.

  • PDF

형상 축소된 연소기의 열손실 및 소염해석 모델 (Thermodynamic Modeling of Heat Loss and Quenching in a Down Scaled Combustor)

  • 이대훈;권세진
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.919-926
    • /
    • 2002
  • Down scaled combustor undergoes increased heat loss that results in incomplete combustion or quenching of the flame as a consequence. Therefore, effect of enhanced heat loss should be understood to design a MEMS scale combustion devices. Existing combustion models are inadequate for micro combustors because they were developed for analysis of regular scale combustor where heat loss can be ignored during the flame propagation. In this research a combustion model is proposed in order to estimate the heat loss and predict quenching limit of flame in a down scaled combustor. Heat loss in the burned region is expressed in a convective form as a product of wall surface area, heat transfer coefficient and temperature difference. Comparison to the measurements showed satisfactory agreement of the pressure and temperature drop. Quenching is accounted for by introducing a correlation of quenching parameter and heat loss. The present model predicted burnt fraction of gases with reasonable accuracy and proved to be applicable in thermal design of a micro combustor.

저 레이놀즈 수가 압축기 성능에 미치는 영향 (EFFECTS OF THE LOW REYNOLDS NUMBER ON THE PERFORMANCE OF AN AXIAL COMPRESSOR)

  • 최민석;백제현;오성환;고한영
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 춘계 학술대회논문집
    • /
    • pp.138-141
    • /
    • 2007
  • A three-dimensional computation was conducted to understand effects of the low Reynolds number on the performance in a low-speed axial compressor at the design condition. The low Reynolds number can originates from the change of the air density became it decreases along the altitude in the troposphere. The performance of the axial compressor such as the static pressure rise wag diminished by the separation on the suction surface and the boundary layer on the hub, which were caused by the low Reynolds number. The total pressure loss at the low Reynolds number was found to be greater than that at the reference Reynolds number at the region from the hub to 90% span. Total pressure loss was scrutinized through three major loss categories in a subsonic axial compressor such as profile loss, tip leakage loss and endwall loss using Denton's loss model, and effects of the low Reynolds number on the performance were analyzed in detail.

  • PDF

배관 해석 프로그램을 통한 해수담수화 플랜트 수압 시스템 분석 (Analysis of hydraulic system for seawater desalination plant through piping analysis program)

  • 최지혁;최용준;양흥식;이상호;최준석
    • 상하수도학회지
    • /
    • 제34권3호
    • /
    • pp.221-230
    • /
    • 2020
  • In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/㎥ of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.

신도시 개발에 따른 첨두유출량과 토양유실량 변화에 관한 연구 -목포시 남악 신도시 개발지를 대상으로- (A Study on the Peak Discharge and Soil Loss Variation due to the New Town Development - In the Case of Namak New Town Development Area -)

  • 우창호;조남열
    • 환경영향평가
    • /
    • 제11권4호
    • /
    • pp.271-280
    • /
    • 2002
  • The purpose of this study is to explore the hydrological impacts and soil loss variation due to the land use change of Namak New Town development area. The analysis of hydrological effects and soil loss variation has been carried out using GIS in this study. In order to estimate the peak runoff volume, the Rational Method which is the most popular technique to predict runoff amounts is used. To estimate the soil loss in the study area, Universal Soil Loss Equation(USLE), which is one of the most comprehensive and useful technique to predict soil erosion is adopted. The result of this study has shown that the peak runoff volume and the total soil loss increase according to the land use change. The peak runoff volume and the total soil loss have been increased about 2 times and about 48 times more than that of pre development. The increasing of the peak runoff volume can be effective erosion, flooding and so on. A careful city planning is the first essential step to minimize the environmental impacts and to construct the ecological city.