• Title/Summary/Keyword: Can loss

Search Result 9,170, Processing Time 0.035 seconds

The analysis of the relation between noise induced hearing loss and noise exposure (소음유발 청력손실과 소음폭로에 대한 연구)

  • 장호경
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.217-225
    • /
    • 1998
  • In this paper, the analysis of the relation between noise induced hearing loss and noise exposure is described for the A-weighted noise levels and exposure duration. The hearing loss and sensitivity threshold shift is investigated by changing the various parameters such as the effects of aging and noise exposure. Total hearing loss is proportional to a function of exposure level based upon the integral of pressure with time. If the noise exposure term is large so that the presbycusis may be neglected, the hearing loss due to aging and noise exposure becomes the noise induced hearing loss. It is shown that exposure to excessive noise can cause temporary loss of hearing that may become permanent if the exposure is prolonged or intense. An audiogram taken from a person suffering from noise induced hearing loss will usually show the greatest loss of hearing sensitivity in the 4kHz region, which is typically the region most sensitive to damage resulting from many types of industrial noise.

  • PDF

An Experimental Study for Drainage Capacity Increment at Surcharged Square Manholes (과부하 사각형 맨홀의 배수능력 증대에 관한 실험적 연구)

  • Kim, Jung Soo;Song, Ju Il;Yoon, Sei Eui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.619-625
    • /
    • 2008
  • Urban sewer systems are designed to operate in open-channel flow regime and energy loss at square manholes is usually not significant. However, the energy loss at surcharged manholes is considered as one of the major causes of inundation in urban area. Therefore, it is necessary to analyze the head loss associated with manholes, especially in surcharged flow. Hydraulic experimental apparatus which can change the manhole inner profile(CASE I, II, III, and IV) and the invert types(CASE A, B, C) were installed for this study. The experimental discharge was $16{\ell}/sec$. As the ratio of b/D(manhole width/inflow pipe diameter) increases, head loss coefficient increases due to strong horizontal swirl motion. The head loss coefficients for CASE I, II, III, and IV were 0.46, 0.38, 0.28 and 0.37, respectively. Side covers increase considerably drainage capacity at surcharged square manhole when the ratio of d/D(side cover diameter/inflow pipe diameter) was 1.0. The head loss coefficients for CASE A, B, and C were 0.45, 0.37, and 0.30, respectively. Accordingly, U-invert is the most effective for energy loss reduction at surcharged square manhole. This head loss coefficients could be available to evaluate the urban sewer system with surcharged flow.

Stator Slot Shape Optimization of Induction Motors for Iron Loss Reduction (철손 저감을 위한 유도전동기 고정자 슬롯 형상 최적화)

  • Park, S.B.;Lee, H.B.;Park, I.H.;Chung, T.K.;Hahn, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.150-152
    • /
    • 1994
  • In this paper, the optimum shape design of stator slot of induction motors for iron loss reduction is proposed. To obtain the flux distribution in induction motors, 2-D finite element method with voltage source is employed. The iron loss is calculated from the iron loss data given by the iron manufacturer. To calculate the sensitivity of iron loss to shape variation, the sensitivity analysis of discrete approach is used. The proposed algorithm is applied to a 3-phase squirrel cage induction motor. The nodes at stator slot boundary of the induction motor are defined as design parameters. By controlling these parameters under the constant volume of iron, we can minimize the iron loss. Furthermore, the stator copper loss is reduced by increasing the slot area. So the stator slot area is determined at the point that the summation of iron loss and copper loss of stator is minimized. Since the constraint of constant volume of iron is nonlinear to the design parameters, the Gradient Projection method is used as an optimization algorithm.

  • PDF

The Quality Loss of a X-Band Transmitter on the LEO Satellite (저궤도 관측위성에 탑재된 X-밴드 송신기의 Quality Loss)

  • 동문호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.9A
    • /
    • pp.1306-1312
    • /
    • 2000
  • The quality loss of a X-band transmitter has been derived by means of MC simulation. The transmitter as a payload of LEO(Low Earth Orbit) satellite is capable of the down transmission the image data of hundreds Mbps generated from the Electro-Optical Instrument in real time. The parameters such as data asymmetry amplitude unbalance,phase unbalance, wave shaping and channel interference are included in the quality loss simulation Assuming that normally distributed gaussian noise is simply added to the channel, the quality loss of 0.7 dB has been obtained through this simulation based on a 95% confidence interval. The obtained quality loss can be applied to the link budgets as an additional loss item.

  • PDF

Approaching Knowledge, Attitudes, and Practices Model for Elderly with Dementia Who are Suspected to Have Hearing Impairment in Korea

  • You, Sunghwa;Han, Woojae
    • Journal of Audiology & Otology
    • /
    • v.24 no.1
    • /
    • pp.40-47
    • /
    • 2020
  • Because the psychophysical symptoms of hearing loss and dementia in the elderly are very similar, untrained healthcare professionals in dementia facilities can easily overlook a severity of hearing loss in their patients. The present study identifies their knowledge, attitudes, and practices (KAP) on hearing loss using a survey whether they may help hearing problem of the patients with dementia. A total of 29 health-care professionals responded to the KAP survey. Also, 2 family members participated. The results showed that most of the nurses and caregivers in elderly medical welfare facilities who worked with dementia patients did not have knowledge of their hearing loss. Even the facility managers did not know how to conduct hearing tests for their patients although they did recognize that some of their patients had a hearing loss. Eventually, actual practice was not possible at this moment by the professionals. However, our respondents did have a positive attitude toward screening for hearing loss and help their patients with dementia wear hearing aids if a clinical guideline was provided. We suggest to develop clear and precise clinical guidelines of the hearing screening test for the dementia patients due to the interrelationship between dementia and hearing loss. When these guidelines apply to elderly residents in a medical welfare facility, early diagnosis and treatment of their sensory loss will help alleviate their dementia as well.

Approaching Knowledge, Attitudes, and Practices Model for Elderly with Dementia Who are Suspected to Have Hearing Impairment in Korea

  • You, Sunghwa;Han, Woojae
    • Korean Journal of Audiology
    • /
    • v.24 no.1
    • /
    • pp.40-47
    • /
    • 2020
  • Because the psychophysical symptoms of hearing loss and dementia in the elderly are very similar, untrained healthcare professionals in dementia facilities can easily overlook a severity of hearing loss in their patients. The present study identifies their knowledge, attitudes, and practices (KAP) on hearing loss using a survey whether they may help hearing problem of the patients with dementia. A total of 29 health-care professionals responded to the KAP survey. Also, 2 family members participated. The results showed that most of the nurses and caregivers in elderly medical welfare facilities who worked with dementia patients did not have knowledge of their hearing loss. Even the facility managers did not know how to conduct hearing tests for their patients although they did recognize that some of their patients had a hearing loss. Eventually, actual practice was not possible at this moment by the professionals. However, our respondents did have a positive attitude toward screening for hearing loss and help their patients with dementia wear hearing aids if a clinical guideline was provided. We suggest to develop clear and precise clinical guidelines of the hearing screening test for the dementia patients due to the interrelationship between dementia and hearing loss. When these guidelines apply to elderly residents in a medical welfare facility, early diagnosis and treatment of their sensory loss will help alleviate their dementia as well.

A Computational Study on the Pressure Loss of Intake System for the Combat Vehicle (전투차량 흡기시스템의 압력손실에 관한 수치적 연구)

  • Moon, Seong-Mok;An, Su-Hong;Lee, Kyoung-Hoon;Woo, Kwan-Je
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.3
    • /
    • pp.25-31
    • /
    • 2012
  • A computational study on the improvement of the pressure loss of intake system, which is located at engine manifold of the combat vehicle, has been conducted using a finite-volume-based, Reynolds-Averaged Navier-Stokes (RANS) solver. The computational result of the pressure loss through the air cleaner is in good agreement with equivalent experimental data. A parametric study was done for improving of the pressure loss of intake system over the baseline case. The effects of five primary parameters such as the height of inlet, the width of interconnection pipe, the shape of drain chamber and the diameter of filter housing were considered in this study. Consequently, this computational investigation can contribute to finding an optimal guideline for the idea of improvement in the pressure loss of intake system.

Electromagnetic field analysis and performance characteristics of PMSM/G with Halbach magnetized array rotor (Halbach 자화 배열 회전자를 갖는 영구자석 동기 전동발전기의 전자기적 해석 및 성능 특성)

  • Jang, Seok-Myeong;You, Dae-Joon;Ko, Kyoung-Jin;Choi, Sang-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.86-88
    • /
    • 2008
  • The rotational loss is one of the most important problems for the practical use of the high power Flywheel Energy Storage System (FESS). This rotational loss is divided as the mechanical loss by windage and bearing and iron loss by hysteresis loop and eddy current in the part of the magnetic field. So, In this paper, a double-sided PMSM/G without the iron loss is designed by analytical method of the magnetic field and estimation of the back-EMF constant represented as the design parameter. This design model consists of the double-sided PM rotor with Halbach magnetized any and coreless 3-phase winding stator. The results show that the double-sided PMSM/G without iron loss can be applicable to the high power FESS.

  • PDF

Loss Minimization for Distribution Network using Partial Tree Search (부분 tree 탐색을 이용한 배전계통의 손실 최소화)

  • Choi, S.Y.;Shin, M.C.;Nam, G.Y.;Cho, P.H.;Park, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.519-521
    • /
    • 2000
  • Network reconfiguration is an operation task, and consists in the determination of the switching operations such to reach the minimum loss conditions of the distribution network. In this paper, an effective heuristic based switch scheme for loss minimization is given for the optimization of distribution loss reduction and a solution approach is presented. The solution algorithm for loss minimization has been developed based on the two stage solution methodology. The first stage of this solution algorithm sets up a decision tree which represent the various switching operations available, the second stage applies a proposed technique called cyclic best first search. Therefore, the solution algorithm of proposed method can determine on-off switch statuses for loss reduction, with a minimum computational effort.

  • PDF

A Study on the Flow Friction Loss of a Shrouded Rotating Disk (밀폐된 단일 회전 원판 주위의 유동손실에 관한 연구)

  • 조성욱;임윤철
    • Tribology and Lubricants
    • /
    • v.19 no.5
    • /
    • pp.292-297
    • /
    • 2003
  • The fundamental fluid mechanics associated with the rotation of a smooth plane disk enclosed within a cylindrical chamber have been studied experimentally. In order to acquire systematic information pertinent to this problem torque and friction loss data were obtained over a wide range of disk Reynolds numbers for axial clearance-disk radius ratio H/R from 0.025 to 0.2 and radial tip gap-disk radius ratio s/R from 0.021 to 0.105. Loss analysis of hard disk drive (HDD) is presented to describe the contribution of windage loss of a rotating disk. The minimum loss form factor of HDD can be obtained from this analysis at each operation conditions.