• Title/Summary/Keyword: Cam Function

Search Result 214, Processing Time 0.024 seconds

Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis (Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례)

  • Kim, Seong-Mo;Park, Jin-Hong;Ryu, Jae-Jun;Shin, Sang Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.126-133
    • /
    • 2018
  • The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.

Expression and in vitro function of anti-cancer mAbs in transgenic Arabidopsis thaliana

  • Song, Ilchan;Kang, Yang Joo;Kim, Dae Heon;Kim, Mi Kyung;Ko, Kisung
    • BMB Reports
    • /
    • v.53 no.4
    • /
    • pp.229-233
    • /
    • 2020
  • The anti-colorectal cancer monoclonal antibody CO17-1A (mAb CO), which recognizes the tumor-associated antigen EpCAM, was expressed in transgenic Arabidopsis plants. PCR and western blot analyses showed the insertion and expression of heavy chain (HC)/HC fused to the KDEL ER retention modif (HCK) and light chain (LC) of mAb CO and mAb CO with HCK (mAb COK) in Arabidopsis transformants. Both plant-derived mAbP CO and mAbP COK were purified from a biomass of approximately 1,000 seedlings grown in a greenhouse. In sandwich ELISA, both mAbP CO showed a slightly higher binding affinity for the target, EpCAM, compared to mAbM CO. In cell ELISA, both mAbsP COs showed binding affinity to the human colorectal cancer cell line SW480. Furthermore, mAbM CO, mAbP CO, and mAbP COK exhibited dose and timedependent regression effects on SW480 cells in vitro. In summation, both mAbP CO and mAbP COK, expressed in Arabidopsis, recognized the target antigen EpCAM and showed anti-proliferative activity against human colorectal cancer cells.

RPD framework fabrication using computer-aided design (CAD) and rapid prototyping (Computer-aided design (CAD) 및 쾌속조형술을 이용한 가철성 국소의치 수복 증례)

  • Park, Seon-Ah;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.94-99
    • /
    • 2017
  • Nowadays, digital dentistry is generally applied to prosthodontics with fabrication of inlays or any other fixed prostheses by utilizing CAD/CAM (computer-aided design/computer-aided manufacturing) technology and intraoral scanner. However, in fabricating removable prosthesis, there are some limitations for digital technology to substitute conventional casting method. Therefore, approaching removable prostheses fabrication with CAD/CAM technology would be a meaningful trial. In this case report, Kennedy class III mandibular edentulous patient who was in need of increasing the vertical dimension of occlusion was treated with removable partial denture using CAD and rapid prototyping technique. Surveying and designing the metal framework of the partial denture was performed with CAD, and sacrificial plastic pattern was fabricated with rapid prototyping technique. During the follow up period of nine months, the removable partial denture has provided satisfactory results in esthetics and function.

Full-mouth rehabilitation of skeletal anterior open bite with severely decayed dentition: A case report (심한 우식을 동반한 골격성 전치부 개방 교합 환자의 전악 수복 증례)

  • Kim, Seong-A;Noh, Kwantae;Pae, Ahran;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.79-87
    • /
    • 2017
  • The open bite malocclusion is a common clinical entity and has multifactorial causes. Development of effective treatment plan and management is dependent on proper diagnosis. The skeletal open bite patient requires a coordinated orthodontic and orthognathic surgical approach to achieve stable occlusion, acceptable esthetics, and improved function. But in case of open bite with severely decayed dentition, restoration in the entire dentition is necessary. Using the facial analysis and diagnostic wax-up, the most effective treatment was prosthetic rehabilitation. The provisional restorations were fabricated to satisfy esthetic and functional requirements, which result in the uniformly distributed occlusal force, anterior and canine guidance. The inter-arch relationship, labio-dental harmony, and the soft tissue aspect, which is important to estimate the longevity were evaluated. Definitive restorations of monolithic zirconia were made by replicating provisional restorations by using the latest CAD/CAM technology. They were delivered to the patient and clinical follow-up observation was satisfactory.

A full-mouth rehabilitation using zirconia all-ceramic crowns: a case report (지르코니아 전부 도재관을 이용한 구강 완전 회복 증례)

  • Choi, In-Seon;Kim, Dong-Woon;Lee, Jung-Jin;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.231-241
    • /
    • 2015
  • As patients' esthetic expectations increase, there is an increase in demand for cosmetic restorations of anterior and posterior teeth that resemble the natural tooth morphology and color. An example of high-strength all-ceramic systems is zirconia with CAD/CAM application. This case report describes a full-mouth rehabilitation using zirconia all-ceramic crowns supported by upper and lower implants and by a minimal increase in the occlusal vertical dimension in a patient with severe abrasion due to loss of posterior teeth.

Full mouth rehabilitation with dental implant utilizing 3D digital image and CAD/CAM system: case report (3차원 디지털 영상과 CAD/CAM 시스템을 활용한 전악 임플란트 수복 증례)

  • Kang, Se-Ha;Jeong, Seung-Mi;Shin, Jae-Ok;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.158-168
    • /
    • 2015
  • This article describes how to use digital system in a fully edentulous case that diagnosis to definitive prosthesis fabrication. While proceeding oral scan and CBCT taking, digital markers were attached on maxillary palate and lower existing denture. Using CBCT image and oral scan image, the bone contour and anatomical structures were analyzed and flapless surgical guide, customized abutment and prosthesis were made. After the osseointegration, the definitive prosthesis was fabricated using the oral scan image with scan body. It provides clinicians with a fast workflow and improves clinical efficiency.

Wear evaluation of CAD-CAM dental ceramic materials by chewing simulation

  • Turker, Izim;Kursoglu, Pinar
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.281-291
    • /
    • 2021
  • PURPOSE. To evaluate the wear of computer-aided design/computer-aided manufacturing (CAD-CAM) dental ceramic materials opposed by enamel as a function of increased chewing forces. MATERIALS AND METHODS. The enamel cusps of healthy human third molar teeth (n = 40) opposed by materials from CAD-CAM dental ceramic groups (n = 10), including Vita Enamic® (ENA), a polymer-infiltrated ceramic network (PICN); GC Cerasmart® (CERA), a resin nanoceramic; Celtra® Duo (DUO), a zirconia-reinforced lithium silicate (ZLS) ceramic; and IPS e.max ZirCAD (ZIR), a polycrystalline zirconia, were exposed to chewing simulation (1,200,000 cycles; 120 N load; 1 Hz frequency; 0.7 mm lateral and 2 mm vertical motion). The wear of both enamel cusps and materials was quantified using a 3D laser scanner, and the wear mechanisms were evaluated by scanning electron microscopy (SEM). The results were analysed using Welch ANOVA and Kruskal Wallis test (α = .05). RESULTS. ZIR showed lower volume loss (0.02 ± 0.01 mm3) than ENA, CERA and DUO (P = .001, P = .018 and P = .005, respectively). The wear of cusp/DUO [0.59 mm3 (0.50-1.63 mm3)] was higher than cusp/CERA [0.17 mm3 (0.04-0.41 mm3)] (P = .007). ZIR showed completely different wear mechanism in SEM. CONCLUSION. Composite structured materials such as PICN and ZLS ceramic exhibit more abrasive effect on opposing enamel due to their loss against wear, compared to uniform structured zirconia. The resin nano-ceramic causes the lowest enamel wear thanks to its flexible nano-ceramic microstructure. While zirconia appears to be an enamel-friendly material in wear volume loss, it can cause microstructural defects of enamel.

Detachable zirconia prosthesis using Milled bar and ADD-TOC attachment in partial edentulous mandible: A case report (하악 부분 무치악 환자에서 Milled-bar와 ADD-TOC 부착 장치를 이용한 탈착 가능한 지르코니아 보철물 수복 증례)

  • Min-Sung Sohn;Jung-Bo Huh
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.90-99
    • /
    • 2023
  • Implant overdentures are widely used as a treatment method to restore oral function in completely edentulous or partially edentulous patients with severe bone resorption. Using a milled bar, it is mechanically advantageous as the implant fixtures are splinted. Applying additional attachments to the bar has the advantage of dispersing the stress applied to the implant. In this case, a patient who used implant overdentures using 4 implants wanted to fabricate a new prosthesis due to repeated fractures of the denture and weakened retention. Milled bar with ADD-TOC attachment and zirconia prosthesis were fabricated by CAD-CAM method and mechanically and aesthetically satisfactory results were obtained.

The Retrospective Study of Advanced Cancer Patients Receiving Integrative Cancer Treatments in single Comprehensive and Integrative Medicine Hospital

  • Jeonghyun Joo;Songha Chon;Kicheul Sohn;Sanghun Lee
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.16-26
    • /
    • 2022
  • Objectives: Traditional Korean medicine (TKM) has been supplied as part of a national health care system in South Korea under a dual medical system, however it has been difficult to mix western medicine and TKM medical practices in existing hospitals. For the objective of innovative integration between them, Comprehensive and Integrative Medicine Hospital were founded in Daegu, South Korea. Here, we discussed the clinical outcomes of cancer patients who received integrative cancer treatment (ICT). Methods: A total of 678 patients previously diagnosed with cancer were retrospectively checked in our institution for 2 years. After applying inclusion/exclusion criteria, 573 patients were eligible for the final analysis. The overall survival (OS) of these patients in the aftercare period were determined. We looked at how clinical factors and treatments including chemotherapy, complementary and alternative medicine (CAM), and TKM affected the OS. Results: At the first visit, 212 subjects had no evidence of disease after tumor resection and 355 ones with advanced cancer, who receiving ICT including chemotherapy, CAM, and TKM showed better OS compared to the CAM including TKM or the best supportive care (median OS = 216, 78, and 46 days, respectively). The median OS was not reached in TKM only, even though the sample size was small (N=12). Even after adjusting for clinical factors associated to liver, renal, and hematologic manifestation, ICT still remained significant. Conclusions: We demonstrated that ICT might be beneficial for advanced cancer regardless of the performance status, liver and renal function, since it positively affected the OS.

Periodontal and prosthetic treatment of maxillary incisors with pathological tooth migration: a case report with 10-year follow-up (병적 치아 이동된 상악 전치의 치주, 보철 치료 후 10년 경과 증례)

  • Kim, So-Yeun;Kwon, Eun-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.26-33
    • /
    • 2022
  • Anterior tooth spacing is observed by pathological tooth movement (PTM), which is common in periodontal patients. And various occlusal factors contribute to PTM, especially in the maxillary anterior region, when there is excessive occlusal force, flaring due to position problem easily occurs. Teeth with loss of periodontal support tissue can secure stability when expanding the support area through intentional splinting, and change the occlusion when restored as a fixed prosthesis. After confirming the stable occlusion through the provisional prosthesis, it can be transferred to the final prosthesis through CAD-CAM. In this case, we present a long-term stable case through accurate diagnosis and treatment of the maxillary anterior teeth that have lost interdental contact.