• Title/Summary/Keyword: Calibration source

Search Result 385, Processing Time 0.028 seconds

Quantifying Uncertainty of Calcium Determination in Infant Formula by AAS and ICP-AES (AAS 및 ICP-AES에 의한 조제분유 중 칼슘 함량 분석의 측정불확도 산정)

  • Jun, Jang-Young;Kwak, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.5
    • /
    • pp.701-710
    • /
    • 2004
  • Uncertainty was quantified to evaluate calcium determination result in infant formula with AAS (Atomic Absorption Spectrometry) and ICP-AES (Inductively Coupled Plasma-Atomic Emission Spectrometry). Uncertainty sources in measurand, such as sample weight, final volume of sample, sample dilution and the instrumental result were identified and used as parameters for combined standard uncertainty based on the GUM (Guide to the expression of uncertainty in measurement) and Draft EURACHEM/CITAC Guide. Uncertainty components of each sources in measurand were identified as resolution, reproducibility and stability of chemical balance, standard material purity, standard material molecular weight, standard solution concentration, standard solution dilution factor, sample dilution factor, calibration curve, recovery, instrumental precision, reproducibility, and stability, Each uncertainty components were evaluated by uncertainty types and included to calculate combined uncertainty. The kinds of uncertainty sources and components in the analytical method by AAS and ICP-AES were same except sample dilution factor for AAS. The analytical results and combined standard uncertainties of calcium content were estimated within the certification range $(367{\pm}20\;mg/100g)$ of CRM (Certified Reference Material) and were not significantly different between method by AAS followed by ashing and method by ICP-AES followed by acid digestion as $359.52{\pm}23.61\;mg/100g\;and\;354.75{\pm}16.16\;mg/100g$, respectively. Identifying uncertainty sources related with precision, repeatability, stability, and maintaining proper instrumental conditions as well as personal proficiency was needed to reduce analytical error.

Study on the calibration phantom and metal artifacts using virtual monochromatic images from dual energy CT (듀얼 에너지 CT의 가상 단색 영상을 이용한 영상 교정 팬텀과 금속 인공음영에 관한 연구)

  • Lee, Jun seong;Lee, Seung hoon;Park, Ju gyung;Lee, Sun young;Kim, Jin ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: To evaluate the image quality improvement and dosimetric effects on virtual monochromatic images of a Dual Source-Dual Energy CT(DS-DECT) for radiotherapy planning. Materials and Methods: Dual energy(80/Sn 140 kVp) and single energy(120 kVp) scans were obtained with dual source CT scanner. Virtual monochromatic images were reconstructed at 40-140 keV for the catphan phantom study. The solid water-equivalent phantom for dosimetry performs an analytical calculation, which is implemented in TPS, of a 10 MV, $10{\times}10cm^2$ photon beam incident into the solid phantom with the existence of stainless steel. The dose profiles along the central axis at depths were discussed. The dosimetric consequences in computed treatment plans were evaluated based on polychromatic images at 120 kVp. Results: The magnitude of differences was large at lower monochromatic energy levels. The measurements at over 70 keV shows stable HU for polystyrene, acrylic. For CT to ED conversion curve, the shape of the curve at 120 kVp was close to that at 80 keV. 105 keV virtual monochromatic images were more successful than other energies at reducing streak artifacts, which some residual artifacts remained in the corrected image. The dose-calculation variations in radiotherapy treatment planning do not exceed ${\pm}0.7%$. Conclusion: Radiation doses with dual energy CT imaging can be lower than those with single energy CT imaging. The virtual monochromatic images were useful for the revision of CT number, which can be improved for target coverage and electron densities distribution.

  • PDF

Application of the QUAL2E Model and Risk Assessment for Water Quality Management in Namyang Stream in Hwaong Polder (화옹유역 남양천의 수질관리를 위한 QUAL2E적용과 위해성 평가)

  • Jang, Jae-Ho;Jung, Kwang-Wook;Kim, Hyung-Chul;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.110-118
    • /
    • 2006
  • The Namyang Stream in Hwaong polder was planned for several water uses including recreation, where people can contact the water and consume some amount during the recreational activity. A human health risk was assessed from exposure to E. coli in the Namyang Stream, which receives partially treated wastewater from watershed. The QUAL2E model was applied to simulate stream water quality, and this model was calibrated and verified with field monitoring data. The calibration result showed a high correlation coefficient of greater than 0.9. The mean concentration of E. coli in the Namyang Stream from the QUAL2E output was in the range of 5,000 ${\sim}$ 8,000 MPN 100 mL^{-1}$, which exceeded national and international guidelines. The Beta-Poisson was used to estimate the microbial risk of pathogens ingestion and the Monte-Carlo analysis (10,000 trials) was used to estimate the risk characterization of uncertainty. The Microbial risk assessment showed that the risk ranged from 7.9 ${\times}\;10^{-6}\;to\;9.4\;{\times}10^{-6}$. Based on USEPA guidelines, the range of $10^{-6}\;to\;10^{-8}$ was considered reasonable levels of risk for communicable disease transmission from environmental exposure, and the risk above $10^{-4}$ was considered to be in the danger of infection. Therefore, water quality of the Namyang Stream might not be in the danger of infection although it exceeded national and international guidelines. However, it was in the range of communicable disease transmission, and thorough wastewater collection and treatment at the source is recommended to secure safe recreation water quality.

Comparison of Solidification Pre-treatment Methods for the Determination of δ13C of Dissolved Organic Carbon: Alkaline Persulfate Oxidation-Carbonate Precipitation vs. Freeze Drying (용존유기탄소의 δ13C : 분석시 고형화 전처리 방법 비교 알칼린 과황산칼륨산화 탄산침전과 동결건조)

  • Jeon, Byeong-Jun;Park, Hyun-Jin;Choi, Woo-Jung;Park, Yong-Se;Lee, Sang-Mo;Yoon, Kwang-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.2
    • /
    • pp.113-118
    • /
    • 2017
  • BACKGROUND: The carbon (C) isotope ratio (${\delta}^{13}C$) of dissolved organic C (DOC) is an indicator of water pollution source. In this study, the potential use of two pre-treatments for the ${\delta}^{13}C$ analysis, alkaline persulfate oxidation coupled with carbonate precipitation (precipitation) and freeze drying (drying), were compared to suggest a more feasible pre-treatment method. METHODS AND RESULTS: Two reference materials with different ${\delta}^{13}C$ values were used for the experiments; chemical grade glucose ($-12.0{\pm}0.02$‰) and pig manure compost extract ($-23.3{\pm}0.04$‰). In the precipitation method, the measured ${\delta}^{13}C$ values were consistently lower than the theoretically calculated values as dissolved $CO_2$ could not be removed due to the alkaline property of the reagents and the dissolution of air $CO_2$ into the alkaline solution. The drying method also resulted in more negative ${\delta}^{13}C$ than the calculated ${\delta}^{13}C$; however, the difference was systematic ($3.9{\pm}0.3$‰) and there was a strong correlation (${\delta}^{13}C_{calculated}=0.87{\times}{\delta}^{13}C_{measured}-0.624$, $r^2=0.98$) between the calculated and measured ${\delta}^{13}C$. Calibration of ${\delta}^{13}C$ using the relationship between the calculated and the measured ${\delta}^{13}C$ values produced reliable and accurate ${\delta}^{13}C$ values. CONCLUSION: Our results suggest that the drying method is more accurate pre-treatment method to minimize the influence of air $CO_2$ compared to the precipitation method for the determination of ${\delta}^{13}C$ of DOC.

Monitoring of Pesticides in the Yeongsan and Seomjin River Basin (영산강 및 섬진강 수계 중 농약 분포 조사)

  • Lee, Young-Jun;Choi, Jeong-Heui;Kim, Sang Don;Jung, Hee-Jung;Lee, Hyung-Jin;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.274-281
    • /
    • 2015
  • BACKGROUND: A lasting release of low levels of persistence chemicals including pesticides and pharmaceuticals into river has a bad influence on aquatic ecosystems and humans. The present study monitored pesticide residues in the Yeongsan and Seomjin river basins and their tributaries as a fundamental study for water quality standard of pesticides.METHODS AND RESULTS: Nine pesticides(aldicarb, carbaryl, carbofuran, chlorpyrifos, 2,4-D, MCPA, methomyl, metolachlor, and molinate) were determined from water samples using SPE-Oasis HLB(pH 2) and LC/MS/MS. Validation of the method was conducted through matrix-matched internal calibration curve, method detection limit(MDL), limit of quantification(LOQ), accuracy, precision, and recovery. MDLs of all pesticides satisfied the GV/10 values. Linearity(r2) was 0.9965- 0.9999, and a percentage of accuracy, precision, and recovery was 89.4-113.6%, 3.1-14.0%, and 90.8-106.2%, respectively. All pesticides exclusive of aldicarb were determined in the river samples, and there was a connection between the positive monitoring results and agricultural use of the pesticides.CONCLUSION: Monitoring outcomes of the present study implied that pesticides were a possible non-point pollutant source in the Yeongsan and Seomjin river basins and tributaries. Therefore, it is required to produce and accumulate more monitoring results on pesticides in river waters to set water quality standards, finally to preserve aquatic ecosystems.