• Title/Summary/Keyword: Calibration source

Search Result 387, Processing Time 0.028 seconds

Coincidence Summing Corrections in HPGe Gamma Ray Spectrometry in Marinelli-beakers with Efficiency (효율을 적용한 마리넬리 비이커에서 HPGe 감마선 분광분석법의 동시합성보정)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.557-563
    • /
    • 2018
  • Coincidence summing correction effects are known to be greater as the efficiency of the detector increases and as the distance between the source and the detector increases. A point source($^{60}Co$) was used to vary the distance in the direction of the detector's center axis and in the radial direction to obtain the P/T ratio for Coincidence summing correction calibration. In this study, values for coincidence summing corrected calibration of the values in the central and radial directions were applied to the mixed volume source(450 ml CRM source) to compare the overall peak efficiency change according to P/T with Geant4. In addition, the efficiency obtained from the mapping method is applied to the seaweed, a marine sample, and the compatibility of the P/T ratio with the detector and sample very dose together. The efficiency corrected to 1,836 keV was applied to the energy zone affected by the efficiency of 500 keV and the relative error of the measured and corrected values was well matcched by the 3.2 % peak efficiency correction. As with 450 mL CRM source, the larger the volume, the lower the P/T ratio was by ${\pm}5%$. This is due to the increased scattering of gamma-rays emitted as the source becomes farther away from the detector, and this change in P/T has been confirmed to affect the Coincidence summing corrected peak efficiency.

Characteristics of Pollutant Loads according to Types of Sources for the Chungju Dam Watershed (충주댐 유역의 오염원에 따른 오염부하량 발생 특성)

  • Kim, Chul-Gyum;Kim, Nam-Won
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.465-472
    • /
    • 2008
  • Soil and Water Assessment Tool (SWAT) model was selected as a tool for assessing the effect of pollutant sources on the total loads from the Chungju Dam upstream watershed. The model was constructed through calibration of parameters related to nitrogen (N) and phosphorus (P), which was based on the runoff and sediment modeling performed in the previous research. Using this, the spatial and temporal pollutant loadings by source type were investigated. Results of this study indicated that in most forested upstream sub-watersheds, pollutant loadings from point sources were very low, and total loadings by point and non-point sources were also insignificant. On the other hand, in #14 sub-watershed including Jecheon city, the loadings by point source were relatively considerable. For the whole watershed, non-point sources accounted for 99% of sediment, 97% of N, and 93% of P loads. And monthly non-point source loadings were concentrated on rainy summer season, while point source loadings of N and P kept nearly constant throughout the year and were high on dry winter season relative to non-point source.

$K_s$-band luminosity evolution of AGB populations based on star clusters in the Large Magellanic Cloud

  • Ko, You-Kyung;Lee, Myung-Gyoon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.56.2-56.2
    • /
    • 2012
  • We present a study of the asymptotic giant branch (AGB) contribution to the total Ks band luminosity of star clusters in the Large Magellanic Cloud (LMC) as a function of age. AGB stars, a representative intermediate-age population, are a strong source of NIR to MIR emission so that they are a critical component for understanding the near-to-mid infrared observation of galaxies. Current calibration of IR emission in evolutionary population synthesis (EPS) models for galaxies is mainly based on a small number of LMC star clusters. However, each LMC star cluster with intermediate age contains only a few AGB stars so that it suffers from a stochastic effect. Therefore a large number of them are needed for solid calibration of the EPS models. We study physical properties of a large number of LMC star clusters to estimate the Ks band luminosity fraction of AGB stars in star clusters as a function of age. We discuss the stochastic effect in calibrating models, and the importance of this calibration for studying the evolution of not only nearby galaxies but also of high-z galaxies.

  • PDF

Sensor Calibration of a Helmet MEG System (헬멧형 뇌자도 장치의 센서 교정)

  • Kwon, H.;Kim, K.;Yu, K.K.;Kim, J.M.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.57-61
    • /
    • 2010
  • We have developed a whole-head MEG system for basic brain research and clinical application. The sensor system consists of a 152 SQUID gradiometer array oriented and located in a suitable way to cover a whole head of the human. The system measures magnetic fields generated by neuronal currents in the brain to get information on the brain activities. For this purpose, the field sensitivity determined by the position, orientation and geometry of the pickup coil as well as amplification factor of the electronic circuits should be known precisely. However, the position and orientation of the pickup coil might be changed from the designed specifications during cool down of the dewar and it is necessary to characterize the field sensitivity. In this study, we made calibration systems to determine the actual position and orientation of the 152 pickup coils and compared the localization results of the N100m source in the auditory cortex.

Uncertainty of Total Alkaloids and Reducing Sugar Determination in Flue-cured Tobacco (황색종 담배중 전알카로이드와 환원당 분석에 대한 불확도 측정)

  • 백순옥;장기철;이운철;한상빈
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.23 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • This study was carried out to evaluate the uncertainty in the analysis of total alkaloids and reducing sugar content in flue-cured tobacco. The sources of uncertainty associated with the analysis of total alkaloids and reducing sugar were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the preparation of standard solution, the precision of calibration curve for standard solution, the reproducibility of analysis, and the determination of water content in tobacco, etc. For the calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier’s catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the calibration curve of standard solution, the reproducibility of analysis, the volume measurement of 1$m\ell$, and the purity of nicotine reference material in the preparation of standard solution. The uncertainty in the addition of extracting solution, the sample weighing, the volume measurement of 100$m\ell$, and the determination of water content of tobacco contributed relatively little to the overall uncertainty. The expanded uncertainty of total alkaloids and reducing sugar in flue-cured tobacco at 95% level of confidence was $\pm$0.12% and $\pm$0.54%, respectively.

  • PDF

Vision Aided Inertial Sensor Bias Compensation for Firing Lane Alignment (사격 차선 정렬을 위한 영상 기반의 관성 센서 편차 보상)

  • Arshad, Awais;Park, Junwoo;Bang, Hyochoong;Kim, Yun-young;Kim, Heesu;Lee, Yongseon;Choi, Sungho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.9
    • /
    • pp.617-625
    • /
    • 2022
  • This study investigates the use of movable calibration target for gyroscopic and accelerometer bias compensation of inertial measurement units for firing lane alignment. Calibration source is detected with the help of vision sensor and its information in fused with other sensors on launcher for error correction. An algorithm is proposed and tested in simulation. It has been shown that it is possible to compensate sensor biases in firing launcher in few seconds by accurately estimating the location of calibration target in inertial frame of reference.

Improvement of Calibration Method of Thermochromic Liquid Crystal Reflecting Measurement Angle (측정각도를 고려한 액정교정기법의 개선)

  • Yoon, Soon-Hyun;Sim, Jae-Kyung;Woo, Chang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.188-194
    • /
    • 2000
  • Thermochromic liquid crystal reflect a unique color at even temperature. Therefore, they have been successfully applied to non-intrusive heat transfer research. Hue capturing method is widely used in the quantitative measurement from the TLC image. However it is affected by several measurement conditions. The distances of camera and light source have little influence on the color, but the value of hue is seriously affected by the measurement angle. In this study, the hue capturing method is improved by considering the effect of measurement angle. This improved calibration method can diminish the misreading of temperature caused by curvature of test surface.

Error correction in laser scanner 3D measurement (레이저 스캐너 3차원 계측에 있어서의 오차 보정)

  • 김응규
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.5
    • /
    • pp.94-101
    • /
    • 1996
  • When objects are scanned spatially by a laser-beam and mechanical mirror scanners, spatial information can be obtained, and then it is improtant to accurately obtain the parameters relating the light source and camera positions, etc.. In this paper, a calibration technique is presented for correction of measuremtn errors in a three-dimensional laser scanner system with two galvanometers. First, a model of the systematic errors is developed based on the geometry of the scanning system. Calibration parameter values are then iteratively adjusted with coarse-fine search in order to minimize errors (evaluation function) between measured and computed distances. It is shown that this correction method results in measurement precision suitable for practical use.

  • PDF

Velocity Calibration of Sinusoidal Mode for Mossbauer Spectrometer and Mossbauer Study on $Fe_3O_4$ (사인파속도형 Mossbauer 분광계의 속도눈금 매기기와 Magnetite의 Mossbauer 분광법에 의한 연구)

  • 이충섭;이찬영
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.5
    • /
    • pp.232-236
    • /
    • 1997
  • We have gone into details about the velocity calibration of sinusoidal mode for Mossbauer spectrometer. Since sinusoidal Mossbauer spectrometer has a ${\gamma}$-ray source that oscillates at the end of loudspeaker with the natural frequency. Doppler velocity is accurate and stable. From the analyzing Mossbauer spectra of $Fe_3O_4$ and U $Fe_3O_4$ (unbalanced $Fe_3O_4$), we have shown the power of correct velocity for sinusoidal mode.

  • PDF

Restoration of Realtime Three-Dimension Positions Using PSD Sensor (PSD센서를 이용한 실시간 3차원 위치의 복원)

  • Choi, Hun-Il;Jo, Yong-Jun;Ryu, Young-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.507-510
    • /
    • 2003
  • In this paper, optical sensor system using PSD(Position Sensitive Detection) is proposed to obtain the three dimensional position of moving markers attached to human body. To find the coordinates of an moving marrer with stereo vision system, two different sight rays of an moving marker are required. Usually, those are acquired with two optical sensors synchronized at the same time. PSD sensor is used to measure the position of an incidence light in real-time. To get the three-dimension position of light source on moving markers, a conventional camera calibration method are used. In this research, we realized a low cost motion capture system. The proposed system shows high three-dimension measurement accuracy and fast sampling frequency.

  • PDF