• Title/Summary/Keyword: Calibration process

Search Result 759, Processing Time 0.025 seconds

Calculation of Dumping Vehicle Trajectory and Camera Coordinate Transform for Detection of Waste Dumping Position (폐기물 매립위치의 검출을 위한 매립차량 궤적 추적 계산 및 카메라 좌표변환)

  • Lee, Dong-Gyu;Lee, Young-Dae;Cho, Sung-Yun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.243-249
    • /
    • 2013
  • In waste repository environment, we can process the waste history efficiently for reuse by recording the history trajectory of the vehicle which loaded waste and the dumping position of the waste vehicle. By mapping the unloaded waste to 3D and by extracting the dumping point, a new method was implemented so as to record the final dumping position and the waste content under various experiments. In this paper, we developed the algorithm which tracking the vehicle and deciding the moment of dumping in landfills. We first trace the position of vehicle using the difference image between current image and background image and then we decide the stop point from the shape of vehicle route and detect the dumping point by comparing the dumping image with the image that vehicle is stopping. From the camera parameters, The transform method between screen coordinate and real coordinate of landfills is proposed.

Field measurement and numerical simulation of excavation damaged zone in a 2000 m-deep cavern

  • Zhang, Yuting;Ding, Xiuli;Huang, Shuling;Qin, Yang;Li, Peng;Li, Yujie
    • Geomechanics and Engineering
    • /
    • v.16 no.4
    • /
    • pp.399-413
    • /
    • 2018
  • This paper addresses the issue of field measurement of excavation damage zone (EDZ) and its numerical simulation method considering both excavation unloading and blasting load effects. Firstly, a 2000 m-deep rock cavern in China is focused. A detailed analysis is conducted on the field measurement data regarding the mechanical response of rock masses subjected to excavation and blasting operation. The extent of EDZ is revealed 3.6 m-4.0 m, accounting for 28.6% of the cavern span, so it is significantly larger than rock caverns at conventional overburden depth. The rock mass mechanical response subjected to excavation and blasting is time-independent. Afterwards, based on findings of the field measurement data, a numerical evaluation method for EDZ determination considering both excavation unloading and blasting load effects is presented. The basic idea and general procedures are illustrated. It features a calibration operation of damage constant, which is defined in an elasto-plastic damage constitutive model, and a regression process of blasting load using field blasting vibration monitoring data. The numerical simulation results are basically consistent with the field measurement results. Further, some issues regarding the blasting loads, applicability of proposed numerical method, and some other factors are discussed. In conclusion, the field measurement data collected from the 2000 m-deep rock cavern and the corresponding findings will broaden the understanding of tunnel behavior subjected to excavation and blasting at great depth. Meanwhile, the presented numerical simulation method for EDZ determination considering both excavation unloading and blasting load effects can be used to evaluate rock caverns with similar characteristics.

Analysis of Organic Acids in Urine by Gas Chromatography/Mass Spectrometry (기체 크로마토그래피/질량분석법을 이용한 요 중에서의 유기산 분석)

  • Yoo, Eun Ah;Ko, Sun Young;Kim, Jong Won;Kim, Jeong Uk;Myung, Seung Woon
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.9
    • /
    • pp.471-482
    • /
    • 1997
  • GC/MS was used to find an optimum experimental condition for the screening of organic acids in urine. Urinary organic acids were isolated through the liquid-liquid extraction method (LLE) to examine the influence of pH and the effect of including the back extraction and oximation processes respectively on the extraction. When pH was adjusted to 0.5 during the extraction without oximation process, relatively higher recovery rate and the smallest relative standard deviations (0.3-12.4%) were obtained. By removing the interference, the addition of back extraction made possible surer identification of organic acids with retention time of 15-16 minutes. Under this condition, we obtained the content distribution of urinary organic acids in healthy Korean children (n=16) by establishing the calibration curves for 51 standard organic acids.

  • PDF

Quantitative Determination of $UO2^{2+}$ with Modified $[Ru(v-bpy)_3]^{2+}$ Polymer Film Electrode (수식된 $[Ru(v-bpy)_3]^{2+}$ 고분자 피막전극을 이용한 U(VI)의 정량)

  • Cha, Seong-Keuck
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.1
    • /
    • pp.17-23
    • /
    • 2000
  • Electrodes of the polycationic film with electropolymerized $[Ru(v-bpy)_3]^{2+}$ having about 1:1 ratio of $PF6^-/ClO_4^-$as the doped counter ions, were modified with xylenol orange and diethylditbiocarbamate by ion exchange which had stability constant as 38.6 and 17.5 respectively. These electrodes were employed in the quantitative multiple determination of U(W) in solution. The working electrode of electrochemical cell for the analytical signal was Pt/p-$[Ru(v-bpy)_3]^{2+}$, ligand, U(VI) with Ag/AgCl reference elecrode. In the stripping voltammetry. electrode process was electron transfer controlled one and calibration curves at the ranges of $1.0{\times}10^{-3}{\sim}1.0{\times}10^{-7}$ M had excellent relationship as 0.99 and relative standard deviation as 5${\sim}$8%.

  • PDF

Poly-3,4-dihydroxybenzoic Acid Film Electrodes Modified with Dopamine for Determination of Ti(IV) Ions (도파민으로 수식된 3,4-dihydroxybenzoic acid 고분자 피막전극을 이용한 Ti(IV)이온의 정량)

  • Cha, Seong-Keuck
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.2
    • /
    • pp.130-133
    • /
    • 2003
  • 3,4-dihydroxybenzoic acid(3,4-DHBA) was electropolymerized on glassy carbon electrode to give the GC/p-3,4-DHBA type electrode which was modified with dopamine by the help of 1-(3-dimethylaminopropyl)-3-ethyl carbodiimide hydrochloride(EDC) acting as a coupling agent. The carboxylic sites on the polymeric surface of p-3,4-DHBA and mine group at the dopamine gave a QCA(Au)/p-3,4-DHBA-dopamine type of modified electrodes. The o-quinone moieties at the electrode surface exhibited high selectivity to titanium ions in solution. The redox process of the electrode is hydroquinone : quinone +$2H^+2e^-$, which had two strong and two weak pairs of peaks at CV. The modified electrode can deposit Ti(IV) ions as much as $4.13\times10^{-5}gcm^{-2}$. The calibration curve of the electrodes, log of the surface coverage-normalized redox response vs log[Ti], exhibited an excellent correlation$(r{\geq}0.997)$ for titanium concentrations ranging from $5.25\times10^{-4}\;to\;5.25\tiems10^{-8}M.$.

Envelope Elimination and Restoration Transmitter for Efficiency and Linearity Improvement of Power Amplifier (전력증폭기의 효율 및 선형성 개선을 위한 포락선 제거 및 복원 송신기)

  • Cho, Young-Kyun;Kim, Changwan;Park, Bong Hyuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.3
    • /
    • pp.292-299
    • /
    • 2015
  • An envelope elimination and restoration transmitter that uses a tri-level envelope encoding scheme is presented for improving the efficiency and linearity of the system. The proposed structure amplifies the same magnitude signal regardless of the input peak-to-average power ratio and reduces the quantization noise by spreading out the noise to the out-of-band frequency, resulting in the enhancement of power efficiency. An improved linearity is also obtained by providing a new timing mismatch calibration technique between the envelope and phase signal. Implementation in a 130 nm CMOS process, transmitter measurements on a 20-MHz long-term evolution input signal show an error vector magnitude of 3.7 % and an adjacent channel leakage ratio of 37.5 dBc at 2.13 GHz carrier frequency.

다채널 표면 플라즈몬 공명 영상장치를 이용한 자기조립 단분자막의 표면 분석

  • Pyo, Hyeon-Bong;Sin, Yong-Beom;Yun, Hyeon-Cheol
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.74-78
    • /
    • 2003
  • Multi-channel images of 11-MUA and 11-MUOH self-assembled monolayers were obtained by using two-dimensional surface plasmon resonance (SPR) absorption. Patterning process was simplified by exploiting direct photo-oxidation of thiol bonding (photolysis) instead of conventional photolithography. Sharper images were resolved by using a white light source in combination with a narrow bandpass filter in the visible region, minimizing the diffraction patterns on the images. The line profile calibration of the image contrast caused by different resonance conditions at each points on the sensor surface (at a fixed incident angle) enables us to discriminate the monolayer thickness in sub-nanometer scale. Furthermore, there is no signal degradation such as photo bleaching or quenching which are common in the detection methods based on the fluorescence.

  • PDF

An Automatic Measuring System of the Electric Fields Produced by Lightning Strokes (뇌방전에 의하여 발생하는 전장의 자동측정시스템)

  • Lee, Bok-Hee;Ahn, Chang-Hwan;Kil, Gyung-Suk
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.47-54
    • /
    • 1996
  • This paper deals with the electric field sensor and automatic measuring system of the time-varying space electric field produced by lightning discharges. The theoretical principle and the design rule of the measuring devices are investigated, and the semisphere-type electric field sensor and the signal process system are fabricated. From the calibration experiments, the frequency bandwidth of the measuring system ranges from 200 [Hz] to 1.56 [MHz] and the sensitivity is 0.96 [m V/V/m] as the amplification gain is 10. In addition, the electric field waveforms produced by lightning discharges are observed by the proposed electric field measuring system from June to August in 1995. The data is sampled with the time interval of 200 [ns] and is automatically recorded by transient signal analyzer(Necolet Pro 30), the resolution of which is 12 bit. And it is registered at personal computer. The electric field waveforms produced by intracloud discharge tend to be bipolar, with two or three narrow and fast rising pulses superimposed on the initial half-cycle.

  • PDF

IMAGING SPECTROMETRY FOR DETECTING FECES AND INGESTA ON POULTRY CARCASSES

  • Park, Bo-Soon;William R.Windham;Kurt C.Lawrence;Smith, Douglas-P
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3106-3106
    • /
    • 2001
  • Imaging spectrometry or hyperspectral imaging is a recent development that makes possible quantitative and qualitative measurement for food quality and safety. This paper presents the research results that a hyperspectral imaging system can be used effectively for detecting fecal (from duodenum, cecum, and colon) and ingesta contamination on poultry carcasses from the different feed meals (wheat, mile, and corn with soybean) for poultry safety inspection. A hyperspectral imaging system has been developed and tested for the identification of fecal and ingesta surface contamination on poultry carcasses. Hypercube image data including both spectral and spatial domains between 430 and 900 nm were acquired from poultry carcasses with fecal and ingesta contamination. A transportable hyperspectral imaging system including fiber optically fabricated line lights, motorized lens control for line scans, and hypercube image data from contaminated carcasses with different feeds are presented. Calibration method of a hyperspectral imaging system is demonstrated using different lighting sources and reflectance panels. Principal Component and Minimum Noise Fraction transformations will be discussed to characterize hyperspectral images and further image processing algorithms such as image band ratio of dual-wavelength images and its histogram stretching with thresholding process will be demonstrated to identify fecal and ingesta materials on poultry carcasses. This algorithm could be further applied for real-time classification of fecal and ingesta contamination on poultry carcasses in the poultry processing line.

  • PDF

MEASUREMENTS OF METABOLIC PARAMETERS IN LACTATING DAIRY COWS WITH NEAR INFRARED SPECTROSCOPY ANALYSIS USING CATTLE FAECAL SAMPLES

  • De la roza, Begona;Martinez, Adela;Modrono, Sagrario;Argamenteria, Alejandro
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1629-1629
    • /
    • 2001
  • The knowledge of the nutrition in animal production is difficult to assess due of difficulty to determine the amount and quality of feeds intake, mainly if forages are the most important compound in the diet. It must be able to know responses to the metabolic process in lactating dairy cows earring out feeds evaluation trials. These metabolism studies with cows, requires measurements of: I) The amount of all feeds consumed. II) Excretion of faeces. III) Excretion of urine. Taking as a basis these trials, forage and total intake, dietary digestibility and balances of nitrogen and energy can be calculated. However, these feeds evaluation experiments with animals are very time consuming and expensives. The faeces excreted by animals containt undigested residues of the diet consumed. For this reason, their analysis can be an successful tool to determine the amount and quality of feed intake and other important biological parameters. The aim of this work was to know if faeces analysis by NIR could be used to determine with enough accuracy some attributes of different lactating dairy cows diets, using a global equation, developed on an heterogeneus population. For this purpose a total of 79 faecal samples from eight grass, three grass silages and two maize silages metabolic trials, on six cows each one, were used to constitute the initial population. The calibration equations were developed to predict forage and total intake, organic matter digestibility, digestibility coefficient of crude energy and digestibility energy. The combination of several trials with different diets and animal conditions gave promising results.

  • PDF