• 제목/요약/키워드: Calibration process

검색결과 759건 처리시간 0.023초

Surrogate based model calibration for pressurized water reactor physics calculations

  • Khuwaileh, Bassam A.;Turinsky, Paul J.
    • Nuclear Engineering and Technology
    • /
    • 제49권6호
    • /
    • pp.1219-1225
    • /
    • 2017
  • In this work, a scalable algorithm for model calibration in nuclear engineering applications is presented and tested. The algorithm relies on the construction of surrogate models to replace the original model within the region of interest. These surrogate models can be constructed efficiently via reduced order modeling and subspace analysis. Once constructed, these surrogate models can be used to perform computationally expensive mathematical analyses. This work proposes a surrogate based model calibration algorithm. The proposed algorithm is used to calibrate various neutronics and thermal-hydraulics parameters. The virtual environment for reactor applications-core simulator (VERA-CS) is used to simulate a three-dimensional core depletion problem. The proposed algorithm is then used to construct a reduced order model (a surrogate) which is then used in a Bayesian approach to calibrate the neutronics and thermal-hydraulics parameters. The algorithm is tested and the benefits of data assimilation and calibration are highlighted in an uncertainty quantification study and requantification after the calibration process. Results showed that the proposed algorithm could help to reduce the uncertainty in key reactor attributes based on experimental and operational data.

사용자 캘리브레이션이 필요 없는 시선 추적 모델 연구 (User-Calibration Free Gaze Tracking System Model)

  • 고은지;김명준
    • 한국정보통신학회논문지
    • /
    • 제18권5호
    • /
    • pp.1096-1102
    • /
    • 2014
  • 적외선 조명을 이용한 간접시선추적 시스템에서는 촬영된 이미지에서 동공에 반사된 조명의 위치에 대한 캘리브레이션이 필수적이다. 하지만 안구의 크기나 머리의 위치에 따라 달라질 수도 있는 변수가 캘리브레이션 과정에서 정의된 상수로 계산에 포함되어 있어 오차를 감소시키는데 한계가 있다. 본 논문은 적외선 조명을 사용하면서도, 사용자 캘리브레이션 과정을 생략할 수 있는 방법을 연구한다. 반사각에 의한 글린트(glint)위치 차이에 영향을 받지 않게 하면서, 시스템의 모델과 시선 계산은 단순하게 하여 실시간 연산이 가능하도록 하는 것이 목표이다.

보스-리브 시험 시 마찰보정선도에 대한 펀치형상 및 유동응력의 영향 (Effect of Punch Design and Flow Stress on Frictional Calibration Curve in Boss and Rib Test)

  • 윤여웅;강성훈;이영선;김병민
    • 소성∙가공
    • /
    • 제18권8호
    • /
    • pp.640-645
    • /
    • 2009
  • Recently, boss and rib test based on backward extrusion process was proposed to quantitatively evaluate the interfacial friction condition in bulk forming process. In this test, the tube-shaped punch with hole pressurizes the workpiece so that the boss and rib are formed along the hole and outer surface of the punch. It was experimentally and numerically revealed that the height of boss is higher than that of the rib under the severe friction condition. This work is focused on the effect of the punch design and flow stress on deformation pattern in boss and rib test. From the boss and rib test simulations, it was found that there is slight variation in both the heights of boss and rib according to the length of punch land, nose radius, and face angle. However the hole diameter of the punch and the clearance between the punch and die have a significant influence on the calibration curves showing the heights of the boss and rib. In addition, the effect of flow stress on the calibration curves was investigated through FE simulations. It was found that there is no effect of strength coefficient of the workpiece on the calibration curves for estimation of friction condition. On the other hand, the strain-hardening exponent of the workpiece has a significant influence on the calibration curve.

근적외 분광분석법을 이용한 나프록센 정제의 정량분석 (Quantification of Naproxen in Pharmaceutical Formulation using Near-Infrared Spectrometry)

  • 김도형;우영아;김효진
    • 약학회지
    • /
    • 제49권1호
    • /
    • pp.1-5
    • /
    • 2005
  • Near-infrared (NIR) spectroscopy has been widely applied in various field, since it is nondestructive and no sample preparation is required. In this paper, NIR spectroscopy was used for the determination of naproxen in a commercial pharmaceutical preparation. NIR spectroscopy was used to determine the content of naproxen in intact naproxen tablets containing 250 mg ($65.8\%$ nominal concentration) by collecting NIR spectra in the range of $1100{\sim}1750nm$. The laboratory-made samples had $46.1{\sim}85.5\%$ nominal naproxen concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR). Model validation was performed by randomly splitting the data set into calibration and validation data set (63 samples as a calibration data set and 42 samples as a validation data set). The developed NIR calibration gave results comparable to the known values of tablets in a laboratorial manufacturing process with standard error of calibration (SEC) and standard error of prediction (SEP) of $1.06\%\;and\;1.04\%$, respectively. The NIR method showed good accuracy and repeatability. NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

광절단법을 이용한 물체 크기 측정 시스템 (Object Width Measurement System Using Light Sectioning Method)

  • 이병주;강현수
    • 한국정보통신학회논문지
    • /
    • 제18권3호
    • /
    • pp.697-705
    • /
    • 2014
  • 본 논문에서는 비전기반 물체의 폭 측정과 그 응용을 위해 광절단법을 이용한 측정방법에 대해 제안한다. 측정 대상은 트레드이며 자동차 타이어의 가장 바깥쪽 면을 의미한다. 전체 시스템은 두 개의 과정으로 구성되는데 교정과정과 검출과정으로 구성된다. 교정과정에서는 카메라 평면과 레이저 평면간의 변환 관계를 규명하고 왜곡 파라미터를 추출한다. 이때 정교하게 제작된 테스트패턴인 지그가 필요하다. 검출과정에서는 레이저가 비추는 영역을 추출하기 위해 배경영역의 화소 분포에 따라 적응식 임계방법을 적용한다. 다음으로 검출된 영역에 세선화 알고리즘을 적용하여 트레드의 숄더와 끝을 검출한다. 최종적으로 숄더와 전체 폭은 호모그래피와 왜곡계수를 이용하여 폭을 계산한다.

채점자 조정(calibration) 교육 제안을 위한 평가자 신뢰도 분석 (Analysis of Evaluator Reliability for the Raters' Calibration Training)

  • 김주아;신유석;서정택
    • 대한치과의사협회지
    • /
    • 제58권5호
    • /
    • pp.284-291
    • /
    • 2020
  • This study analyzed the change in the rater reliability based on the student's practice evaluation process conducted at Yonsei University College of Dentistry. Through this, we suggest the significance of the rater calibration training in the student's practical evaluation of dental college. Nine professors from the department of Conservative Dentistry, Yonsei University College of Dentistry, analyzed the results of class II restoration cases twice in 2017 and once in 2018. Intra Class Correlation (ICC) which is a statistic used to determine the consistency of raters with three or more scores, was also calculated. ICC values increased as raters participated in rater calibration meetings and grading experiences. This shows that the rater reliability is related to the grading experience and feedback from calibration meeting. Based on the results of previous studies that grading experiences and rater calibration training can cause a meaningful change in rater behavior, we propose to conduct rater calibration training to ensure the evaluator reliability.

  • PDF

다층퍼셉트론의 정합 근사화에 의한 2차원 영상의 카메라 오차보정 (A 2-D Image Camera Calibration using a Mapping Approximation of Multi-Layer Perceptrons)

  • 이문규;이정화
    • 제어로봇시스템학회논문지
    • /
    • 제4권4호
    • /
    • pp.487-493
    • /
    • 1998
  • Camera calibration is the process of determining the coordinate relationship between a camera image and its real world space. Accurate calibration of a camera is necessary for the applications that involve quantitative measurement of camera images. However, if the camera plane is parallel or near parallel to the calibration board on which 2 dimensional objects are defined(this is called "ill-conditioned"), existing solution procedures are not well applied. In this paper, we propose a neural network-based approach to camera calibration for 2D images formed by a mono-camera or a pair of cameras. Multi-layer perceptrons are developed to transform the coordinates of each image point to the world coordinates. The validity of the approach is tested with data points which cover the whole 2D space concerned. Experimental results for both mono-camera and stereo-camera cases indicate that the proposed approach is comparable to Tsai's method[8]. Especially for the stereo camera case, the approach works better than the Tsai's method as the angle between the camera optical axis and the Z-axis increases. Therefore, we believe the approach could be an alternative solution procedure for the ill -conditioned camera calibration.libration.

  • PDF

Single-Phase Energy Metering Chip with Built-in Calibration Function

  • Lee, Youn-Sung;Seo, Jeongwook;Wee, Jungwook;Kang, Mingoo;Kim, Dong Ku
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권8호
    • /
    • pp.3103-3120
    • /
    • 2015
  • This paper presents a single-phase energy metering chip with built-in calibration function to measure electric power quantities. The entire chip consists of an analog front end, a filter block, a computation engine, a calibration engine, and an external interface block. The key design issues are how to reduce the implementation costs of the computation engine from repeatedly used arithmetic operations and how to simplify calibration procedure and reduce calibration time. The proposed energy metering chip simplifies the computation engine using time-division multiplexed arithmetic units. It also provides a simple and fast calibration scheme by using integrated digital calibration functionality. The chip is fabricated with 0.18-μm six-layer metal CMOS process and housed in a 32-pin quad-flat no-leads (QFN) package. It operates at a clock speed of 4096 kHz and consumes 9.84 mW in 3.3 V supply.

근적외 분광분석법을 이용한 황색종 잎담배의 화학성분 분석

  • 김용옥;이경구;장기철;김기환
    • 한국연초학회지
    • /
    • 제20권2호
    • /
    • pp.183-190
    • /
    • 1998
  • This study was conducted to analyze chemical components in flue-cured tobacco using near infrared spectroscopy(NIRS). Samples were collected in '96 and '97 crop year and were scanned in the wavelengths of 400 ~ 2500 nm by near infrared analyzer(NIRSystem Co., Model 6500). Calibration equations were developed and then analyzed flue-cured samples by NIRS. The standard error of calibration(SEC) and performance (SEP) of '96 crop year samples between NIRS and standard laboratory analysis(SLA) were 0.18% and 0.24% for nicotine, 1.60% and 1.77% for total sugar, 0.13% and 0.15% for total nitrogen, 0.58% and 0.68% for crude ash, 0.23% and 0.28% for ether extracts, and 0.09% and 0.08% for chlorine, respectively. The coefficient of determination($R^2$) of calibration and prediction samples between NIRS and SLA of '96 crop year samples was 0.94~0.99 and 0.83~0.97 depending on chemical components, respectively. The SEC and SEP of '97 crop year samples were similar to those of '96 crop year samples. The SEP of '97 crop year samples which were analyzed using '96 calibration equation was 0.32 % for nicotine, 2.72% for total sugar, 0.14 % for total nitrogen, 1.00 % for crude ash, 0.48 for ether extracts and 0.17% for chlorine, respectively. The prediction result was more accurate when calibration and prediction samples were produced in the same crop year than those of the different crop year. The SEP of '96 and '97 crop year samples using calibration equation which was developed '96 plus '97 crop year samples was similar to that of '96 crop year samples using 96 calibration equation and that of '97 crop year samples using '97 calibration equation, respectively. The SEP of '97 crop year samples using calibration equation which was developed '96 plus '97 crop year samples was lower than that of '97 crop year samples analyzed by '96 calibration equation. To improve the analytical inaccuracy caused by the difference of crop year between calibration and prediction samples, we need to include the prediction sample spectra which are different from calibration sample spectra in recalibration sample spectra, and then develop recalibration equation. Although the analytical result using NIR is not as good as SLA, the chemical component analysis using NIR can apply to tobacco leaves, leaf process or tobacco manufacturing process which demand the rapid analytical result.

  • PDF

항공기용 디지털 영상에 대한 검정(Calibration) 및 정확도 평가 (Calibration and accuracy evaluation of airborne digital camera images)

  • 이승헌;위광재;이강원;이홍술
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 춘계학술발표회논문집
    • /
    • pp.183-195
    • /
    • 2004
  • Photogrammetry is one of the most important sources of GIS application. Nowadays, color photos are used and camera is integrated with GPS/INS sensors. However the photos are still taken from analogue camera and scanned for digital image. For the convenient and accurate image application especially for 3D, airborne digital camera images is essential. In this paper, digital image calibration process with GPS/INS and its accuracy evaluation was presented.

  • PDF