• Title/Summary/Keyword: Calibration process

Search Result 762, Processing Time 0.028 seconds

Calibration of Low-cost Inertia Navigation System with Sun Line of Sight Vector (태양시선벡터를 이용한 저가 관성항법시스템의 보정)

  • Jang, Se-Ah;Choi, Kee-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.8
    • /
    • pp.774-778
    • /
    • 2008
  • The inaccuracy of inertial sensors used in low cost IMU's limits the usage to ARS, at best. Sensor fusion technologies are widely used to overcome this problem. GPS is the most popular secondary sensor, but GPS alone cannot fully compensate the IMU errors in the initial alignment process and rectilinear flights. This paper presents a new concept of aiding the low cost IMU with the sun line of sight vector. The simulation and experimental results in this paper proves that aiding of INS/GPS with the sun line of sight vector increases the observability and improves accuracy remarkably.

Application simulations as numerical laboratory for large diameter rockfill materials (대입경 락필재료에 대한 수치시험실 활용해석)

  • Jeon, Je-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.852-855
    • /
    • 2010
  • Numerical simulations for large scale triaxial tests with large diameter rockfill materials are conducted using distinct element method. For generation of compacted assembly with specific grain size distribution and initial material porosity, the clump logic method and expansion of generated particles are adapted. With micro parameters which are chosen by calibration process, discrete particle modelling of triaxial test in case of other confining stress and cyclic loading condition were conducted. Also numerical simulations of fluid injection into particulate materials were conducted to observe cavity initiation and propagation using distinct element method. The fluid scheme solves the continuity and Navior-Stokes equations numerically, then derives pressure and velocity vectors for fixed grid by considering the existence of particles within the fluid cell.

  • PDF

Improvement of Accuracy for Determination of Hydrogen Storage of Sieverts Apparatus (부피법을 이용한 수소 저장 성능 평가 장치의 수소 저장량 측정법 개선)

  • Cho, Won-Chul;Han, Sang-Sub;Park, Chu-Sik
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.1
    • /
    • pp.64-70
    • /
    • 2008
  • This paper briefly discusses the main sources of errors and their solutions for measuring hydrogen uptake from gas phase by the Sieverts technique. Correction of volumetric errors of apparatus, density of hydrogen storage material, estimation of temperature gradient are investigated. Systematic errors and the change of density of the host material according to the pressure have been the subject of much controversy in recent years. We considered the standard ball calibration, temperature gradient distribution, pretreatment of hydrogen storage materials to minimize errors. We could lessen the miscalculations after applying those methods to Equilibrium pressure-composition isotherm data.

Motion Capture of the Human Body Using Multiple Depth Sensors

  • Kim, Yejin;Baek, Seongmin;Bae, Byung-Chull
    • ETRI Journal
    • /
    • v.39 no.2
    • /
    • pp.181-190
    • /
    • 2017
  • The movements of the human body are difficult to capture owing to the complexity of the three-dimensional skeleton model and occlusion problems. In this paper, we propose a motion capture system that tracks dynamic human motions in real time. Without using external markers, the proposed system adopts multiple depth sensors (Microsoft Kinect) to overcome the occlusion and body rotation problems. To combine the joint data retrieved from the multiple sensors, our calibration process samples a point cloud from depth images and unifies the coordinate systems in point clouds into a single coordinate system via the iterative closest point method. Using noisy skeletal data from sensors, a posture reconstruction method is introduced to estimate the optimal joint positions for consistent motion generation. Based on the high tracking accuracy of the proposed system, we demonstrate that our system is applicable to various motion-based training programs in dance and Taekwondo.

An Experimental Investigation of Air Fuel Ratio Measurement using Laser Induced Acetone Fluorescence (아세톤 형광을 이용한 공연비 측정 기법 연구)

  • Park Seungjae;Huh Hwanil;Oh Seungmook
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.353-356
    • /
    • 2002
  • Planar laser induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Preliminary investigation was performed to measure quantitative air excess ratio distribution in an engine fueled with LPG. It is known that fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone was excited by KrF excimer laser (248nm) and its fluorescence image was acquired by ICCD camera with a cut-of filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile was suggested. Raw images were divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which was taken by a calibration process, were converted to air excess ratio distribution. This investigation showed instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

  • PDF

Study on the multi-channel dosimetry system with microprocessor and its application to radition therapy (마이크로 프로세서를 이용한 선량측정 장치의 제작과 그 응용에 관한 연구)

  • 강정구;이정옥;김승곤;김부길;김진기
    • Progress in Medical Physics
    • /
    • v.3 no.1
    • /
    • pp.19-24
    • /
    • 1992
  • We have desingned multi channel dosimetry system with Intel single-chip microprocessor. We considered that this system is very useful for patient dose measurement, measurement of sealed source dose distribution and calibration of small field for stereotatic radiosurgery system We have designed that this system use commercially available semicondutor detector and personal computer can control this system and process data through RS-232C serial port.

  • PDF

A study on the nonlinear error correction of the phase measuring profilometry (PMP 형상 측정법에서 비선형 오차보정에 관한 연구)

  • 황용선;강영준;박낙규;백성훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.513-516
    • /
    • 2003
  • Phase Measuring Profilometry(PMP) has been developed as one of three dimensional 3-D shape measuring methods. The 3-D profile of an object was calculated from the phase data obtained by the sinusoidal patterns projected on the object. However, in some cases the approximation includes considerable errors. In this paper, the effect on the errors caused by the optical geometry and the calibration procedure in PMP technique are discussed. The errors which occured in the process of calculating the 3-D profile from the phase distribution are investigated theoritically and experimentally.

  • PDF

Experimental and numerical studies toward the implementation of shape memory alloy ties in masonry structures

  • Casciati, Sara;Hamdaoui, Karim
    • Smart Structures and Systems
    • /
    • v.4 no.2
    • /
    • pp.153-169
    • /
    • 2008
  • The use of pre-tensioned shape memory alloy (SMA) wires to retrofit historic masonry structures is investigated. A small wall, serving as a prototype masonry specimen, is constructed to undergo a series of shaking-table tests. It is first studied in its original state, and its dynamic characteristics (in terms of modal frequencies) are extracted from the recorded signals. The results are then compared with those obtained when an increasing number of couples of pre-stressed SMA wires are introduced in the specimen to link the bricks together. A three-dimensional finite element model of the specimen is developed and calibrated according to the modal parameters identified from each experimental test (with and without SMA wires). The calibration process is conducted by enhancing the masonry mechanical behaviour. The results and the effectiveness of the approach are presented.

A 6-Gb/s Differential Voltage Mode Driver with Independent Control of Output Impedance and Pre-Emphasis Level

  • Bae, Chang-Hyun;Choi, Dong-Ho;Ahn, Keun-Seon;Yoo, Changsik
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.5
    • /
    • pp.423-429
    • /
    • 2013
  • A 6-Gb/s differential voltage mode driver is presented whose output impedance and pre-emphasis level can be controlled independently. The voltage mode driver consists of five binary-weighted slices each of which has four sub-drivers. The output impedance is controlled by the number of enabled slices while the pre-emphasis level is determined by how many sub-drivers in the enabled slices are driven by post-cursor input. A prototype transmitter with a voltage-mode driver implemented in a 65-nm CMOS logic process consumes 34.8-mW from a 1.2-V power supply and its pre-emphasized output signal shows 165-mVpp,diff and 0.56-UI eye opening at the end of a cable with 10-dB loss at 3-GHz.

Development of Automatic ALC Block Measurement System Using Machine Vision (머신 비전을 이용한 ALC 블록 생산공정의 자동 측정 시스템 개발)

  • 엄주진;허경무
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.6
    • /
    • pp.494-500
    • /
    • 2004
  • This paper presents a machine vision system, which inspects the measurement of the ALC block on a real-time basis in the production process. The automatic measurement system was established with a CCD camera, an image grabber, and a personal computer without using assembled measurement equipment. Images obtained by this system was processed by an algorithm, specially designed for an enhanced measurement accuracy. For the realization of the proposed algorithm, a preprocessing method that can be applied to overcome uneven lighting environment, boundary decision method, unit length decision method in uneven condition with rocking objects, and a projection of region using pixel summation are developed. From our experimental results, we could find that the required measurement accuracy specification is sufficiently satisfied by using the proposed method.