• Title/Summary/Keyword: Calibration process

Search Result 762, Processing Time 0.03 seconds

Speeding up the KLT Tracker for Real-time Image Georeferencing using GPS/INS Data

  • Tanathong, Supannee;Lee, Im-Pyeong
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.6
    • /
    • pp.629-644
    • /
    • 2010
  • A real-time image georeferencing system requires all inputs to be determined in real-time. The intrinsic camera parameters can be identified in advance from a camera calibration process while other control information can be derived instantaneously from real-time GPS/INS data. The bottleneck process is tie point acquisition since manual operations will be definitely obstacles for real-time system while the existing extraction methods are not fast enough. In this paper, we present a fast-and-automated image matching technique based on the KLT tracker to obtain a set of tie-points in real-time. The proposed work accelerates the KLT tracker by supplying the initial guessed tie-points computed using the GPS/INS data. Originally, the KLT only works effectively when the displacement between tie-points is small. To drive an automated solution, this paper suggests an appropriate number of depth levels for multi-resolution tracking under large displacement using the knowledge of uncertainties the GPS/INS data measurements. The experimental results show that our suggested depth levels is promising and the proposed work can obtain tie-points faster than the ordinary KLT by 13% with no less accuracy. This promising result suggests that our proposed algorithm can be effectively integrated into the real-time image georeferencing for further developing a real-time surveillance application.

Feasibility study on a stabilization method based on full spectrum reallocation for spectra having non-identical momentum features

  • Kilyoung Ko ;Wonku Kim ;Hyunwoong Choi;Gyuseong Cho
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2432-2437
    • /
    • 2023
  • Methodology for suppressing or recovering the distorted spectra, which may occur due to mutual non-uniformity and nonlinear response when a multi-detector is simultaneously operated for gamma spectroscopy, is presented with respect to its applicability to stabilization of spectra having the non-identical feature using modified full spectrum reallocation method. The modified full-spectrum reallocation method is extended to provide multiple coefficients that describe the gain drift for multi-division of the spectrum and they were incorporated into an optimization process utilizing a random sampling algorithm. Significant performance improvements were observed with the use of multiple coefficients for solving partial peak dislocation. In this study, our achievements to confirm the stabilization of spectrum having differences in moments and modify the full spectrum reallocation method provide the feasibility of the method and ways to minimize the implication of the non-linear responses normally associated with inherent characteristics of the detector system. We believe that this study will not only simplify the calibration process by using an identical response curve but will also contribute to simplifying data pre-processing for various studies as all spectra can be stabilized with identical channel widths and numbers.

Development of Dual-mode Signal Processing Module for Multi-slit Prompt-gamma Camera (다중 슬릿 즉발감마선 카메라를 위한 이중모드 신호처리 모듈 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Sung Hun;Kim, Chan Hyeong;Shin, Dong Ho;Lee, Se Byeong;Jeong, Jonh Hwi
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.37-45
    • /
    • 2016
  • In proton therapy, in vivo proton beam range verification is very important to deliver conformal dose to the target volume and minimize unnecessary dose to normal tissue. For this purpose, a multi-slit prompt-gamma camera module made of 24 scintillation detectors and 24-channel signal processing system is under development. In the present study, we have developed and tested a dual-mode signal processing system, which can operate in the energy calibration mode and the fast data acquisition mode, to process the signals from the 24 scintillation detectors. As a result of performance test, using the energy calibration mode, we were able to perform energy calibration for the 24 scintillation detectors at the same time and determine the discrimination levels for the detector channels. Further, using the fast data acquisition mode, we were able to measure a prompt-gamma distribution induced by a 45 MeV proton beam. The measured prompt gamma distribution was found similar to the proton dose distribution at the distal fall-off region, and the estimated beam range was $17.13{\pm}0.76mm$, which is close to the proton beam range of 16.15 mm measured by an EBT film.

A Practical standard Air Flow Generator System to Calibrate and Compare Performance of Two Different Respiratory Air Flow Measurement Modules (호흡기류 계측모듈의 교정과 성능 비교를 위한 실용적인 표준기류 생성 시스템)

  • Lee, In-Kwang;Park, Mi-Jung;Lee, Sang-Bong;Kim, Kyoung-Ok;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.115-122
    • /
    • 2015
  • A standard air flow generator system was developed to generate air flows of various levels simultaneously applied to two different air flow transducer modules. Axes of two identical standard syringes for spirometer calibration were connected with each other and driven by a servo-motor. Linear displacement transducer was also connected to the syringe axis to accurately acquire the volume change signal. The user can select either sinusoidal or square waveform of volume change and manually input any volume as well as maximal flow rate levels ranging 0~3 l and 0~15 l/s, respectively. Various volume and flow levels were input to operate the system, then the volume signal was acquired followed by numerical differentiation to obtain the air flow signal. The measured volumes and maximal air flow rates were compared with the user input data. The relative errors between the user-input and the measured stroke volumes were all within 0.5%, demonstrating very accurate driving of the system. In case of the maximal flow rate, relatively large error was observed when the syringe was driven very fast within a very short time duration. However, except for these few data, most measured flow rates revealed relative errors of approximately 2%. When the measure and user-input stroke volume and maximal flow rate data were analyzed by linear regression analysis, respectively, the correlation coefficients were satisfactorily higher than 0.99 (p < 0.0001). These results demonstrate that the servo-motor controls the syringes with enough accuracy to generate standard air flows. Therefore, the present system would be very much practical for calibration process as well as performance evaluation and comparison of two different air flow transducer modules.

Estimation of Measurement Uncertainty for the HPLC Analysis of Deoxynivalenol in Wheat (밀에서 HPLC에 의한 데옥시니발레놀 분석의 측정불확도 산정)

  • Ok, Hyun-Ee;Chang, Hyun-Joo;Ahn, Jang-Hyuk;Cho, Jae-Young;Chun, Hyang-Sook
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.258-264
    • /
    • 2009
  • The principal objective of this study was to estimate the measurement uncertainty associated with determination of deoxynivalenol (DON), a mycotoxin generated by Fusarium strain, in food. In service of this goal, wheat as a food matrix was analyzed via high performance liquid chromatography-ultraviolet (HPLC-UV) detection using an immunoaffinity column for clean-up. The uncertainty sources in the measurement process were identified by sample weight, final volume, and sample concentration in extraction volume with components including standard stock solution, working standard solution, 5 standard solutions, calibration curve, matrix, and instrument. The expanded uncertainty for DON at a concentration of 300 ${\mu}g/kg$ was estimated as 71.62 ${\mu}g/kg$ using a coverage factor of two, which provides a confidence level of approximately 95%. The most influential component in the uncertainty sources was the recovery of the wheat matrix, followed by the calibration curve. These results indicate that all efforts may be directed toward reducing the uncertainties of the recovery of the wheat matrix and the calibration curve to obtain a reliable HPLC-UV method for DON analysis in wheat.

Development of Rapid and Simple Drug Identification and Semi Quantitative Analytical Program by Gas Chromatography-Mass Spectrometry (가스크로마토그래피/질량분석기를 이용한 약물의 확인 및 간이 정량분석 프로그램 개발)

  • Kim, Eun-Mi;Han, Eun-Young;Hong, Hyo-Jeong;Jeong, Su-Jin;Choe, Sang-Gil;Rhee, Jong-Sook;Jung, Jin-Mi;Yeom, Hye-Sun;Lee, Han-Sun;Lee, Sang-Ki
    • YAKHAK HOEJI
    • /
    • v.55 no.2
    • /
    • pp.106-115
    • /
    • 2011
  • Systematic toxicological analysis (STA) means the process for general unknown screening of drugs and toxic compounds in biological fluids. In order to establish STA, in previous study we investigated pattern of drugs & poisons in autopsy cases during 2007~2009 in Korea, and finally selected 62 drugs as target drugs for STA. In this study, rapid and simple drug identification and quantitative analytical program by gas chromatography-mass spectrometry(GC-MS) was developed. The in-house program, "DrugMan", consisted of modified chemstation data analysis menu and newly developed macro modules. Total 55 drugs among 62 target drugs were applied to this program, they were 14 antidepressants, 8 anti-histamines, 5 sedatives/hypnotics, 5 narcotic analgesics, 3 antipsychotic drugs, and etc. For calibration curves, fifty five drugs were divided into four groups of range considering their therapeutic or toxic concentrations in blood specimen, i.e. 0.05~1 mg/l, 0.1~1 mg/l, 0.1~5 mg/l or 0.5~10 mg/l. Standards spiked bloods were extracted by solid-phase extraction (SPE) with trimipramine-D3 as internal standard. Parameters such as retention times, 3 mass fragment ions, and calibration curves for each drug were registered to DrugMan. A series of identification, semi quantitation of target drugs and reporting the results were performed automatically. Calibration curves for most drugs were linear with correlation coefficients exceeding 0.98. Sensitivity rate of DrugMan was 0.90 (90%) for 55 drugs at the level of 0.5 mg/l. For standard spiked bloods at the level of 0.5 mg/l for 29 drugs, semi quantitative concentrations were ranged 0.36~0.64 mg/l by DrugMan. If more drugs are registered to database in DrugMan in further study, it will be useful tools for STA in forensic toxicology.

A Class-C type Wideband Current-Reuse VCO With 2-Step Auto Amplitude Calibration(AAC) Loop (2 단계 자동 진폭 캘리브레이션 기법을 적용한 넓은 튜닝 범위를 갖는 클래스-C 타입 전류 재사용 전압제어발진기 설계)

  • Kim, Dongyoung;Choi, Jinwook;Lee, Dongsoo;Lee, Kang-Yoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.94-100
    • /
    • 2014
  • In this paper, a design of low power Current-Reuse Voltage Controlled Oscillator (VCO) which has wide tuning range about 1.95 GHz ~ 3.15 GHz is presented. Class-C type is applied to improve phase noise and 2-Step Auto Amplitude Calibration (AAC) is used for minimizing the imbalance of differential VCO output voltage which is main issue of Current-Reuse VCO. The mismatch of differential VCO output voltage is presented about 1.5mV ~ 4.5mV. This mismatch is within 0.6 % compared with VCO output voltage. Proposed Current-Reuse VCO is designed using CMOS $0.13{\mu}m$ process. Supply voltage is 1.2 V and current consumption is 2.6 mA at center frequency. The phase noise is -116.267 dBc/Hz at 2.3GHz VCO frequency at 1MHz offset. The layout size is $720{\times}580{\mu}m^2$.

Effect Analysis of Tillage Depth on Rotavator Shaft Load Using the Discrete Element Method (이산요소법을 활용한 경심이 로타리 작업기의 경운날 축 부하에 미치는 영향 분석)

  • Bo Min Bae;Dae Wi Jung;Dong Hyung Ryu;Jang Hyeon An;Se O Choi;Yeon Soo Kim;Sang Dae Lee;Seung Je Cho
    • Journal of Drive and Control
    • /
    • v.20 no.4
    • /
    • pp.115-122
    • /
    • 2023
  • This study utilized a discrete element method (DEM) simulation, as one of the virtual field trials, to predict the impact of tillage depth on the rotary blade shaft during rotavator tilling. The virtual field for the simulation was generated according to soil properties observed in an actual field. Following the generation of particles for the virtual field, a sequence of calibration steps followed to align the mechanical properties more closely with those of real soil. Calibration was conducted with a focus on bulk density and shear torque, resulting in calibration errors of just 0.02% for bulk density and 0.52% for shear torque. The prediction of the load on a rotary tiller's blade shaft involved a three-pronged approach, considering shaft torque, draft force, and vertical force. In terms of shaft torque, the values exhibited significant increases of 42.34% and 36.91% for every 5-centimeter increment in tillage depth. Similarly, the vertical force saw substantial growth by 40.41% and 36.08% for every 5-centimeter increment. In contrast, the variation in draft force based on tillage depth was comparatively lower at 18.49% and 0.96%, indicating that the effect of tillage depth on draft force was less pronounced than its impact on shaft torque and vertical force. From a perspective of agricultural machinery research, this study provides valuable insights into the DEM soil modeling process, accounting for changes in soil properties with varying tillage depths. These findings are expected to be instrumental in future agricultural machinery design studies.

A Calibration Technique for a Two-Axis Magnetic Compass in Telematics Devices

  • Cho, Seong-Yun;Park, Chan-Gook
    • ETRI Journal
    • /
    • v.27 no.3
    • /
    • pp.280-288
    • /
    • 2005
  • This paper presents an efficient algorithm for using the two-axis magnetic compass in portable devices. The general magnetic compass module consists of a three-axis magnetic compass and a two-axis inclinometer to calculate tilt-compensated azimuth information. In this paper, the tilt error is compensated using just a two-axis magnetic compass and two-axis accelerometer. The third-axis data of the magnetic compass is estimated using coordinate information that includes the extended dip angle and tilt information. The extended dip angle is estimated during the normalization process. This algorithm can be used to provide the tilt-compensated heading information to small portable devices such as navigation systems, PDAs, cell phones, and so on.

  • PDF

Position estimation of welding panels for sub-assembly welding line in shipbuilding using camera vision system (조선 소조립 용접자동화의 부재위치 인식을 위한 camera vision system)

  • 전바롬;윤재웅;고국원;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.361-364
    • /
    • 1997
  • There has been requested to automate the welding process in shipyard due to its dependence on skilled operators and the inferior working environments. According to these demands, multiple robot welding system for sub-assembly welding line has been developed, realized and installed at Keoje Shipyard. In order to realize automatic welding system, robots have to be equipped with the sensing system to recognize the position of the welding panels. In this research, a camera vision system is developed to detect the position of base panels for subassembly line in shipbuilding. Two camera vision systems are used in two different stages (Mounting and Welding) to automate the recognition and positioning of welding lines. For automatic recognition of panel position, various image processing algorithms are proposed in this paper.

  • PDF