• 제목/요약/키워드: Calibration process

검색결과 759건 처리시간 0.027초

온도변화를 고려한 가변온도형 열선유속계의 교정식 (Calibration Equation for VTA Including the Effect of Ambient Temperature Drift)

  • 이신표;고상근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.99-104
    • /
    • 2000
  • Calibration equation for Variable Temperature Anemometer(VTA) has been tested for measured velocity-output data and the calibration process has been compared with that of Constant Temperature Anemometer(CTA). VTA has greater sensitivity than that of any other conventional anemometers, but to be more popular technique in flow field measurement, simple, accurate and well established calibration process should be suggested. To meet this purpose, similar calibration method used for CTA has been adopted for VTA and finally calibration equation for VTA including the effect of temperature drift has been proposed.

  • PDF

Evaluation of Field Calibration Test on Rail for Train Wheel Force Measurement

  • Sim, Hyoung-Bo;Yeo, Inho
    • International Journal of Railway
    • /
    • 제8권1호
    • /
    • pp.1-4
    • /
    • 2015
  • An accurate measurement of the train-track interaction forces is important for track performance evaluation. In the field calibration test as a wheel load measurement process, the calibration system creates a different boundary condition in comparison with that in the train wheel passage. This study aims to evaluate a reliability of the field calibration test in the process of wheel load measurement. Finite element models were developed to compare the deformed shapes, bending moment and shear force profiles on the rail section. The analysis results revealed that the deformed shapes and their associated bending moment profiles on the rail are significantly different in two numerical simulations of the calibration test and the train wheel load passage. However, the shear stress profile on the rail section of the strain gauge installation in the field was almost identical, which may imply that the current calibration test is sufficiently reliable.

실리콘 웨이퍼 휨형상 측정 정밀도 향상을 위한 시스템변수 보정법 (System calibration method for Silicon wafer warpage measurement)

  • 김병창
    • 한국기계가공학회지
    • /
    • 제13권6호
    • /
    • pp.139-144
    • /
    • 2014
  • As a result of a mismatch of the residual stress between both sides of the silicon wafer, which warps and distorts during the patterning process. The accuracy of the warpage measurement is related to the calibration. A CCD camera was used for the calibration. Performing optimization of the error function constructed with phase values measured at each pixel on the CCD camera, the coordinates of each light source can be precisely determined. Measurement results after calibration was performed to determine the warpage of the silicon wafer demonstrate that the maximum discrepancy is $5.6{\mu}m$ with a standard deviation of $1.5{\mu}m$ in comparison with the test results obtained by using a Form TalySurf instrument.

밀도검층 검출기 보정에 관한 기초 연구 (An Experimental Study on Density Tool Calibration)

  • 김영화;김기주;임헌태;김지훈;공남영
    • 지구물리
    • /
    • 제7권4호
    • /
    • pp.237-245
    • /
    • 2004
  • 밀도 검층에 미치는 각 영향 요소들을 검토하고 현행 사용자 보정의 한계와 문제점 파악을 위한 기초 실험이 수행되었다. 간접 보정 방법에 속하는 현행 사용자 보정을 물과 알루미늄 블럭을 사용하는 사용자 보정과 반감기 식을 이용한 사용자 보정으로 구분하여 분석하였으며 국내에서 처음 시도된 지구물리모형 시추공을 이용한 직접 보정 방법의 적용 결과와 비교, 분석되었고 이로부터 기존의 사용자 보정의 한계와 가능성을 평가할 수 있었다.

  • PDF

Viewing Angle-Improved 3D Integral Imaging Display with Eye Tracking Sensor

  • Hong, Seokmin;Shin, Donghak;Lee, Joon-Jae;Lee, Byung-Gook
    • Journal of information and communication convergence engineering
    • /
    • 제12권4호
    • /
    • pp.208-214
    • /
    • 2014
  • In this paper, in order to solve the problems of a narrow viewing angle and the flip effect in a three-dimensional (3D) integral imaging display, we propose an improved system by using an eye tracking method based on the Kinect sensor. In the proposed method, we introduce two types of calibration processes. First process is to perform the calibration between two cameras within Kinect sensor to collect specific 3D information. Second process is to use a space calibration for the coordinate conversion between the Kinect sensor and the coordinate system of the display panel. Our calibration processes can provide the improved performance of estimation for 3D position of the observer's eyes and generate elemental images in real-time speed based on the estimated position. To show the usefulness of the proposed method, we implement an integral imaging display system using the eye tracking process based on our calibration processes and carry out the preliminary experiments by measuring the viewing angle and flipping effect for the reconstructed 3D images. The experimental results reveal that the proposed method extended the viewing angles and removed the flipping images compared with the conventional system.

근적외 분광분석법을 이용한 버어리종 잎담배 화학성분 분석

  • 김용옥;장기철;이경구
    • 한국연초학회지
    • /
    • 제21권1호
    • /
    • pp.95-101
    • /
    • 1999
  • This study was carried out to analyze chemical components in burley tobacco using near infrared spectroscopy(NIRS). Samples were collected in '96 and '97 crop year. Calibration equations were developed by modified partial least square. The standard error performance(SEP) of '96 crop year samples between NIRS and standard laboratory analysis were 0.25% for nicotine, 0.18% for total nitrogen, 0.59% for crude ash, 0.32% for ether extracts, and 0.14% for chlorine, respectively. The analytical results of '97 crop year samples were similar to those of '96 crop year samples. The analytical result of '97 crop year samples analyzed by '96 calibration equation was more inaccurate than that of '96 crop year samples. The SEP of '96 or '97 crop year samples applying calibration equation derived from '96 plus '97 crop year samples was similar to that of '96 or '97 crop year samples analyzed by '96 or '97 calibration equation, respectively. The SEP of '97 crop year samples analyzed by calibration equation derived from '96 plus '97 crop year samples was more accurate than that of '97 crop year samples analyzed by '96 calibration equation. To improve the analytical inaccuracy caused by the difference of crop year between calibration and prediction samples, we need to include the prediction sample spectra which were different from calibration sample spectra in recalibration sample spectra, and then develop recalibration equation. The NIRS can apply to analyze burley leaf tobacco, leaf process or tobacco manufacturing process which were required the rapid analytical result.

  • PDF

EXAMINING THE BOUNDARIES OF INSTRUMENT-TO-INSTRUMENT CALIBRATION TRANSPORT

  • Kester, Michael D.;Baudais, Fred L.;Simpson, Michael B.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1191-1191
    • /
    • 2001
  • Generation of precise, accurate, and robust calibration models for spectroscopic methods of analysis can be time-consuming, expensive, and sometimes difficult to achieve. For these reasons, efforts have been made to find ways in which the calibration from one instrument can be moved to another with minimal performance reduction. A slight shift in nomenclature from the common term calibration transfer to the term calibration transport is used here to help resolve the subtle difference between two means of moving a calibration from one instrument to another. The former term denotes a transfer procedure that includes mathematical manipulation of the calibration data via some determined transfer function, whereas the latter term does not. Todays generation of process and laboratory FTNIR analyzers is capable of not only achieving calibration transfer, but also calibration transport often without the need of slope or bias adjustments. Several studies are used to examine the boundaries of the extent to which calibration transport is achieved in the refining industry. Data collected on multiple on-line and laboratory FTNIR analyzers located in multiple countries are considered, and the ultimate limitations discussed.

  • PDF

선박용 곡판형상의 실시간 측정을 위한 다중 슬릿빔 보정법 (3D Calibration Method on Large-Scale Hull Pieces Profile Measurement using Multi-Slit Beams)

  • 김병창;이세한
    • 제어로봇시스템학회논문지
    • /
    • 제19권11호
    • /
    • pp.968-973
    • /
    • 2013
  • In the transportation industry, especially in the shipbuilding process, 3D surface measurement of large-scale hull pieces is needed for fabrication and assembly. We suggest an efficient method for checking the shape of curved plates under the forming operation with short time by measuring 3D profiles along the multi lines of the target surface. For accurate profile reconstruction, 2D camera calibration and 3D calibration using gauge blocks were performed. The evaluation test shows that the measurement accuracy is within the boundary of tolerance required in the shipbuilding process.

Large Calibration Chamber의 개발 (Development of Large Calibration Chamber System)

  • 정충열;김태준;김대규;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.673-678
    • /
    • 2002
  • Laboratory calibration chamber tests for cone penetrometers, pressuremeters and dilatometers in cohesionless soil specimens have been conducted by numerous researchers. However, there have been only few applications to compacted or preconsolidated cohesive soils. Therefore, for the first time, Calibration Chamber System was developed in Korea University. This can be attributed to the extremely time consuming and laborious process involved in the preparation of large cohesive soil specimens in addition to other complexities involving instrumentation for pore pressure monitoring and the need for maintaing saturation by back pressure. Chamber System with similar principle as LSU Chamber System was made of more strengthen and complementary form by increasing system diameter(1.2m), carrying out 1st and 2nd consolidation process in one system for smooth and safe work, accurate Data Aquisition.

  • PDF

룩업테이블을 이용한 스캐너 캘리브레이션에 관한 연구 (A Study on the Scanner Calibration Method Using Look-up Table)

  • 신춘범;강상훈
    • 한국인쇄학회지
    • /
    • 제20권1호
    • /
    • pp.79-90
    • /
    • 2002
  • Recently, the research about color matching for the input/output devices of printing process is progressing rapidly by the digitization. The calibration method of flatbed scanner widely used as an input device for prepress process is especially important for color proofing of high quality color prints. In this paper, scanner calibration method using 3-dimensional look-up table and tetrahedral interpolation was examined and analysed comparatively on the three kinds of original copies, such as photograph, dye sublimation proof and ink jet print for IT8.T/2 target.

  • PDF