• Title/Summary/Keyword: Calibration process

Search Result 763, Processing Time 0.034 seconds

An Advanced Method of Simulation and Analysis for Electromagnetic Environment on the Mobile Receiver in a Shielded Anechoic Chamber

  • Kim, Jung-Hoon;Rhee, Joong-Geun
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.4
    • /
    • pp.229-234
    • /
    • 2006
  • This paper presents an advanced method of simulation for EM(electromagnetic) environment that affects on mobile receivers. A new calibration algorithm in the process of simulation is introduced. With a proposed calibration method, the time required for simulation is reduced and this makes it possible to simulate a near-real time EM environment in a shielded anechoic chamber. EM environment data acquisition and logging techniques with GPS for simulation were developed.

The Study of The Calibration Method for The UHF PD Detection in GIS (GIS에서 UHF 부분방전 검출법의 교정방안 연구)

  • Lee, W.Y.;Chong, J.K.;Choi, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2290-2292
    • /
    • 1999
  • The Ultra-High Frequency(UHF) method for detecting a partial discharge in Gas-Insulated Substation(GIS) has some advantages compared to a conventional method(IEC 270) but there is a shortage in view of a quantitative analysis. Therefore, this paper describes the implementation of a calibrator and the calibration process based on it. And its characteristics are confirmed through the experiment using the 362kV GIS chamber.

  • PDF

DRAM bus system을 위한 analog calibration 적용 Pre-emphasis Transmitter

  • Park, Jeong-Jun;Cha, Su-Ho;Yu, Chang-Sik;Gi, Jung-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.653-654
    • /
    • 2006
  • A Pre-emphasis transmitter for DRAM bus system has achieved 3.2Gbps/pin operation at 1.8V supply voltage with 0.18um CMOS process. The transmitter has 800MHz PLL to generate 4 phase clocks. The 4 phase clocks are used for input clock of PRBS and multiplexing. One tap pre-emphasis is used to reduce inter symbol interference (ISI) caused by channel low pass effects. The analog calibration makes the optimized driver impedance independent with the PVT variation.

  • PDF

A Study on the Forming Process of Stair Type Side Sill for Automobile using DP780 (DP780이 적용된 자동차용 계단형 사이드실의 성형공정 연구)

  • Suh, C.H.;Shin, H.D.;Jung, Y.C.;Park, C.D.;Lim, Y.H.;Kim, Y.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.301-306
    • /
    • 2009
  • High strength steels are widely used for lightweight automobile parts and the control of springback is very important in sheet metal forming. The object of this study is to develop the forming process for stair type side sill made of high strength steel, DP780. Stair type side sill with local formed area and geometry change area can improve stiffness and design freedom but there are a few studies for forming process. The forming technology considered in this paper is form type process, which have many advantages for farming of high strength steel compared with draw type process. Finite element analysis is carried out to predict formability and springback. It is shown that angle calibration of die is essential for reducing springback, and local forming involving bead is effective to control springback also. The effectiveness of local forming and angle calibration is verified by experimental.

  • PDF

A Study on the Forming Process of Stair Type Side Sill for Automobile using DP780 (DP780이 적용된 자동차용 계단형 사이드실의 성형공정 연구)

  • Suh, C.H.;Shin, H.D.;Jung, Y.C.;Park, C.D.;Lim, Y.H.;Kim, Y.S.
    • Transactions of Materials Processing
    • /
    • v.18 no.8
    • /
    • pp.601-606
    • /
    • 2009
  • High strength steels are widely used for lightweight automobile parts and the control of springback is very important in sheet metal forming. The object of this study is to develop the forming process for stair type side sill made of high strength steel, DP780. Stair type side sill with local formed area and geometry change area can improve stiffness and design freedom but there are few studies for forming process. The forming technology considered in this paper is form type process, which has many advantages for forming of high strength steel compared with draw type process. Finite element analysis is carried out to predict formability and springback. It is shown that angle calibration of die is essential for reducing springback, and local forming involving bead is effective to control springback also. The effectiveness of local forming and angle calibration is verified by experimental.

Fabrication of the FET-based SPM probe by CMOS standard process and its performance evaluation (CMOS 표준 공정을 통한 SPM 프로브의 제작 및 그 성능 평가)

  • Lee, Hoontaek;Kim, Junsoo;Shin, Kumjae;Moon, Wonkyu
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.236-242
    • /
    • 2021
  • In this paper, we report the fabrication of the tip-on-gate of a field-effect-transistor (ToGoFET) probe using a standard complementary metal-oxide-semiconductor (CMOS) process and the performance evaluation of the fabricated probe. After the CMOS process, I-V characteristic measurement was performed on the reference MOSFET. We confirmed that the ToGoFET probe could be operated at a gate voltage of 0 V due to channel ion implantation. The transconductance at the operating point (Vg = 0 V, Vd = 2 V) was 360 ㎂/V. After the fabrication process was completed, calibration was performed using a pure metal sample. For sensitivity calibration, the relationship between the input voltage of the sample and the output current of the probe was determined and the result was consistent with the measurement result of the reference MOSFET. An oxide sample measurement was performed as an example of an application of the new ToGoFET probe. According to the measurement, the ToGoFET probe could spatially resolve a hundred nanometers with a height of a few nanometers in both the topographic image and the ToGoFET image.

Accurate Camera Calibration Method for Multiview Stereoscopic Image Acquisition (다중 입체 영상 획득을 위한 정밀 카메라 캘리브레이션 기법)

  • Kim, Jung Hee;Yun, Yeohun;Kim, Junsu;Yun, Kugjin;Cheong, Won-Sik;Kang, Suk-Ju
    • Journal of Broadcast Engineering
    • /
    • v.24 no.6
    • /
    • pp.919-927
    • /
    • 2019
  • In this paper, we propose an accurate camera calibration method for acquiring multiview stereoscopic images. Generally, camera calibration is performed by using checkerboard structured patterns. The checkerboard pattern simplifies feature point extraction process and utilizes previously recognized lattice structure, which results in the accurate estimation of relations between the point on 2-dimensional image and the point on 3-dimensional space. Since estimation accuracy of camera parameters is dependent on feature matching, accurate detection of checkerboard corner is crucial. Therefore, in this paper, we propose the method that performs accurate camera calibration method through accurate detection of checkerboard corners. Proposed method detects checkerboard corner candidates by utilizing 1-dimensional gaussian filters with succeeding corner refinement process to remove outliers from corner candidates and accurately detect checkerboard corners in sub-pixel unit. In order to verify the proposed method, we check reprojection errors and camera location estimation results to confirm camera intrinsic parameters and extrinsic parameters estimation accuracy.

Analyses of Steady State Mixing Process of Two-Liquids Using Artificial Intelligence (인공지능을 이용한 이종액체 정상 상태 혼합의 혼합과정 해석)

  • KONG, DAEKYEONG;YUM, JUHO;CHO, GYEONGRAE;DOH, DEOGHEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.523-529
    • /
    • 2018
  • Two liquids which are generally used as fuels of rockets are mixed and their mixing process is quantitatively investigated by the use of particle image velocimetry (PIV). As working fluids for the liquid mixing, Dimethylfuran (DMF) and JetA1 oils have been used. Since the specific gravity of DMF is larger than that of JetA1 oil, the DMF oil has been set at the lower part of the JetA1 oil. For better visualization of the mixing process, Rhodamin B powder has been blended into the DMF oil. An agitator having 3 blades has been used for mixing the two liquids. For quantitative visualization, a LCD monitor has been used as a light source. A color camera, camcoder, has been used for recording the mixing process. The images captured by the camcoder have been digitized into three color components, R, G, and B. The color intensities of R, G, and B have been used as the inputs of the neural network of which hidden layer has 20 neurons. Color-to-concentration calibration has been performed before commencing the main experiments. Once this calibration is completed, the temporal changes of the concentration of the DMF has been quantitatively analyzed by using the constructed measurement system.

Applications of MSC Pan Nuc for RAdiometric Cal/Val of KOMPSAT-2 (KOMPSAT-2 검보정을 위한 MSC Pan에 대한 NUC 적용과 결과 분석)

  • Song, Jeong-Heon;Seo, Du-Cheon;Lee, Dong-Han;Lim, Hyo-Suk
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.209-212
    • /
    • 2007
  • In the NUC of KOMPSAT-2, The NUC table for each pixel are divided as HF NUC(high frequency NUC) and LF NUC (low frequency NUC) to apply to few restricted facts in the operating system of KOMPSAT-2. This work presents the algorithm and process of NUC table generation and shows the imagery to compare with and without calibration.

  • PDF

Application and testing of a triple bubbler sensor in molten salts

  • Williams, A.N.;Shigrekar, A.;Galbreth, G.G.;Sanders, J.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1452-1461
    • /
    • 2020
  • A triple bubbler sensor was tested in LiCl-KCl molten salt from 450 to 525 ℃ in a transparent furnace to validate thermal-expansion corrections and provide additional molten salt data sets for calibration and validation of the sensor. In addition to these tests, a model was identified and further developed to accurately determine the density, surface tension, and depth from the measured bubble pressures. A unique feature of the model is that calibration constants can be estimated using independent depth measurements, which allow calibration and validation of the sensor in an electrorefiner where the salt density and surface tension are largely unknown. This model and approach were tested using the current and previous triple bubbler data sets, and results indicate that accuracies are as high as 0.03%, 4.6%, and 0.15% for density, surface tension, and depth, respectively.