Estimation of Moisture Content in Comminuted Miscanthus based on the Intensity of Reflected Light

  • Cho, Yongjin;Lee, Dong Hoon
    • Journal of Biosystems Engineering
    • /
    • 제40권3호
    • /
    • pp.296-304
    • /
    • 2015
  • Purpose: The balance between miscanthus production and its cost effectiveness depends greatly on its moisture content during post processing. The objective of this research was to measure the moisture content using a non-destructive and non-contact methodology for in situ applications. Methods: The moisture content of comminuted miscanthus was controlled using a closed chamber, a humidifier, a precision weigher, and a real-time monitoring software developed in this research. A CMOS sensor equipped with $50{\times}$ magnifier lens was used to capture magnified images of the conditioned materials with moisture content level from 5 to 30%. The hypothesis is that when light is incident on the comminuted particles in an inclined manner, higher moisture content results in light being reflected with a higher intensity. Results: A linear regression analysis for an initiative hypothesis based on general histogram analysis yielded insufficient correlations with low significance level (<0.31) for the determination coefficient. A significant relationship (94% confidence level) was determined at level 108 in a reverse accumulative histogram proposed based on a revised hypothesis. A linear regression model with the value at level 108 in the reverse accumulative histogram for a magnified image as the independent variable and the moisture content of comminuted miscanthus as the dependent variable was proposed as the estimation model. The calibrated linear regression model with a slope of 92.054 and an offset of 32.752 yielded 0.94 for the determination coefficient (RMSE = 0.2%). The validation test showed a significant relationship at the 74% confidence level with RMSE 6.4% (n = 36). Conclusions: To compensate the inconsistent significance between calibration and validation, an estimation model robust against various systematic interferences is necessary. The economic efficiency of miscanthus, which is a promising energy resource, can be improved by the real-time measurement of its crucial material properties.

표적모의장치를 이용한 SAR 장비의 성능 분석 (Performance Analysis of SAR System Using Radar Target Simulation Equipment)

  • 권순구;여환용;박성민;한지훈;정창식;김기완;신현익
    • 한국전자파학회논문지
    • /
    • 제29권2호
    • /
    • pp.118-127
    • /
    • 2018
  • 본 논문에서는 합성개구레이다(Synthetic Aperture Radar: SAR) 장비의 성능 분석을 위하여 레이다 표적모의장치를 설계, 제작한 결과를 선보인다. 먼저 표적모의장치의 기능과 성능에 대해 설명하고, SAR 장비와 연동하기 위한 표적 시나리오 생성방법에 대해 설명하였다. 또한 제작된 표적모의장치를 이용하여 SAR 장비의 시간지연 값을 간단하고 정확하게 측정하고 보상하는 방법을 개발하였다. 시간지연이 보상된 SAR 장비와 표적모의장치를 이용하여 SAR 영상에서 점표적을 획득하고, IRF(Impulse Response Function) 분석을 통해 성능을 분석하였다. 그 결과, 방위방향 IRF의 PSLR(Peak to Side Lobe Ratio)은 -13.25 dB, 해상도는 0.49 m로 이론값과 매우 유사한 값을 보였다.

지능형 다중 화상감시시스템을 위한 움직이는 물체 추적 및 보행자/차량 인식 방법 (Tracking and Recognition of vehicle and pedestrian for intelligent multi-visual surveillance systems)

  • 이삭;조재수
    • 한국정보통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.435-442
    • /
    • 2015
  • 본 논문에서는 지능형 다중 화상감시시스템에 응용할 수 있는 움직이는 물체 추적 및 보행자/차량 인식 방법을 제안한다. 지능형 다중 화상감시시스템은 다수의 고정형 카메라와 한 대의 PTZ 카메라로 구성되며, 고정형 카메라에서 검출된 움직이는 물체들을 PTZ 카메라로 팬/틸트/줌 제어하고, 보행자인지 또는 차량인지를 자동으로 인식한다. 넓은 영역을 감시하는 고정된 카메라에서 검출된 물체는 너무 작고, 변별력이 떨어지는 문제가 있다. 이러한 문제를 극복하기 위해 PTZ 카메라를 통한 특정 움직이는 물체를 팬/틸트/줌인 제어함으로써 움직이는 물체의 변별력과 감시성능을 높일 수 있다. 제안된 시스템은 움직이는 물체를 추적하는 기능 외에 SVM 학습알고리즘을 이용하여 검출된 물체가 보행자 또는 차량인지를 판단할 수도 있다. 그리고 추적에러를 줄이기 위해 기존의 고정된 카메라와 PTZ 카메라간의 캘리브레이션 방법을 개선한다. 다양한 실험결과를 통하여 제안한 시스템의 효용성을 입증하였다.

방사선원 3차원 위치탐지를 위한 방사선 영상장치 개발 (Development of Three-Dimensional Gamma-ray Camera)

  • 이남호;황영관;박순용
    • 한국정보통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.486-492
    • /
    • 2015
  • 방사선 영상장치는 방사능 누출사고의 조기처리 및 확산 피해 최소화에 필수적인 장비이며, 가까운 미래에 빅마켓으로 성장될 원전폐로 분야에서도 중요한 역할을 담당할 것으로 예상된다. 현재까지 개발된 방사선 영상장치는 방사선 오염원의 위치를 방향 정보만으로 탐지하여 가시화하고 있고 방사선원의 거리 측정은 불가능한 실정이다. 본 논문에서는 스테레오 카메라 원리를 적용하여 방사선원의 3차원 위치정보를 추출할 수 있는 새로운 기법의 방사선 3차원 영상장치의 구현에 대해 연구하였다. 한 대의 방사선 센서와 CCD 카메라, 그리고 팬틸의 컴팩트한 구성으로 설계된 방사선 3차원 영상장치(K3-RIS)는 위치변환 제어에 의한 스테레오 방사선 영상 취득과 연속모드 제어 및 고속 스테레오 영상정보처리 기능이 특징이다. 개발한 장치의 기능검증을 위해 감마 방사선원(Cs-137)을 대상으로 실험을 수행한 결과 선원간의 거리와 무관하게 3% 이하의 거리측정 오차를 확인하였다.

시선 추적 시스템에서의 호모그래피를 이용한 글린트 복원 알고리즘 (Glint Reconstruction Algorithm Using Homography in Gaze Tracking System)

  • 고은지;김명준
    • 한국정보통신학회논문지
    • /
    • 제18권10호
    • /
    • pp.2417-2426
    • /
    • 2014
  • 간접 시선 추적 시스템은 적외선 조명을 각막에 반사시켜 그 모습을 카메라로 촬영하여 얻은 이미지에서 시선을 계산한다. 적외선 조명이 각막에 반사되어 이미지에 나타난 점을 글린트라고 한다. 최근 간접 추적 시스템은 머리의 움직임에 민감하지 않고 캘리브레이션 과정을 거치지 않도록 하기 위해 여러 개의 적외선 조명, 즉 여러개의 글린트를 사용하는 경우가 많다. 하지만 실험 도중 글린트의 일부가 보이지 않을 수 있는데, 이러한 경우 해당 프레임에서는 시선 계산을 할 수 없게 된다. 본 논문에서는 여러 개의 적외선 조명을 사용하는 시선 추적 시스템에서 여러 가지 이유로 유실되거나 인식이 어려운 글린트의 모습을 살펴본 후, 인식이 가능한 나머지 글린트 위치를 이용하여 이러한 글린트의 위치를 복원하는 알고리즘을 제안한다. 이 알고리즘을 통해 시선 추적 시 유효한 이미지 프레임의 개수를 증가 시키고, 복원 단계에서 글린트의 위치 변형 모델을 이용하여 글린트의 왜곡 또한 보정하여 시선 추적 결과의 오차도 줄일 수 있다.

CT 모의치료장치에서 발생된 X-선 빔의 유효에너지 계산식 유도 (Derivation of the Effective Energy Calculation Formula of the X-ray Beam Generated by the CT Simulator)

  • 김종언;이상훈
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.869-875
    • /
    • 2021
  • 이 연구의 목적은 CT 모의치료장치에서 발생된 X-선 빔의 유효에너지 계산식을 유도하는데 있다. 90, 120, 140 kVp X-선 빔 하에서, AAPM CT 성능 팬텀의 CT수 교정 삽입부는 CT 모의치료장치로 5번 스캔하였다. 폴리에틸렌, 폴리스틸렌, 물, 나일론, 폴리카보네이트, 그리고 아크릴의 CT수는 각각의 CT 슬라이스 영상에 대하여 측정하였다. 단일 관전압 하에서 측정된 CT수 평균값과 미국표준기술연구소의 자료로부터 계산된 각각의 광자에너지에 대응하는 선감쇠계수들을 선형정합하였다. 얻어진 상관계수들 중 최대값을 갖는 광자에너지를 유효에너지를 결정하였다. 이와 같은 방법으로, 각각의 관전압에서 생성된 X-선 빔의 유효에너지를 결정하였다. 결정된 유효에너지(y)들와 관전압(x)들을 선형정합하여 유효에너지 계산식으로서 y=0.33026x+30.80263을 유도하였다.

Hyperspectral imaging technique to evaluate the firmness and the sweetness index of tomatoes

  • Rahman, Anisur;Park, Eunsoo;Bae, Hyungjin;Cho, Byoung-Kwan
    • 농업과학연구
    • /
    • 제45권4호
    • /
    • pp.823-837
    • /
    • 2018
  • The objective of this study was to evaluate the firmness and the sweetness index (SI) of tomatoes with a hyperspectral imaging (HSI) technique within the wavelength range of 1000 - 1550 nm. The hyperspectral images of 95 tomatoes were acquired with a push-broom hyperspectral reflectance imaging system, from which the mean spectra of each tomato were extracted from the regions of interest. The reference firmness and sweetness index of the same sample was measured and calibrated with their corresponding spectral data by partial least squares (PLS) regression with different preprocessing methods. The calibration model developed by PLS regression based on the Savitzky-Golay second-derivative preprocessed spectra resulted in a better performance for both the firmness and the SI of the tomatoes compared to models developed by other preprocessing methods. The correlation coefficients ($R_{pred}$) were 0.82, and 0.74 with a standard error of prediction of 0.86 N, and 0.63, respectively. Then, the feature wavelengths were identified using a model-based variable selection method, i.e., variable importance in projection, from the PLS regression analyses. Finally, chemical images were derived by applying the respective regression coefficients on the spectral image in a pixel-wise manner. The resulting chemical images provided detailed information on the firmness and the SI of the tomatoes. The results show that the proposed HSI technique has potential for rapid and non-destructive evaluation of firmness and the sweetness index of tomatoes.

그림자 제거와 색도 히스토그램 비교를 이용한 배회행위 검출 (Loitering Behavior Detection Using Shadow Removal and Chromaticity Histogram Matching)

  • 박은수;이형호;윤명규;김민규;곽종훈;김학일
    • 정보보호학회논문지
    • /
    • 제21권6호
    • /
    • pp.171-181
    • /
    • 2011
  • 본 논문에서는 감시영역을 벗어난 후 다시 돌아온 객체에 대한 배회행위를 효과적으로 인식 할 수 있는 지능형 배회행위 검출 시스템을 제안한다. 전경과 배경을 가우시안 혼합 모델을 이용하여 분리하고 그림자를 제거하여 객체를 인식한 후, 객체의 색도 히스토그램을 이용하여 감시영역을 벗어난 후 돌아온 객체들을 판단하고 감시영역에 존재하는 시간을 보전한다. 배회행위를 판단하기 위해 카메라 캘리브레이션을 통해 실세계 배회패턴과 같은 행태의 매크로 블록을 영상좌표에 도입한 후 배회궤적을 추출하고, 감시영역에 객체가 존재하는 시간을 함께 고려하여 배회행위를 판단한다. 제안하는 방법은 실험에 사용된 모든 배회행위 프레임에서 정확하게 배회행위를 검출하여 그 효과를 입증하였다.

Impact of viewing conditions on the performance assessment of different computer monitors used for dental diagnostics

  • Hastie, Thomas;Venske-Parker, Sascha;Aps, Johan K.M.
    • Imaging Science in Dentistry
    • /
    • 제51권2호
    • /
    • pp.137-148
    • /
    • 2021
  • Purpose: This study aimed to assess the computer monitors used for analysis and interpretation of digital radiographs within the clinics of the Oral Health Centre of Western Australia. Materials and Methods: In total, 135 computer monitors(3 brands, 6 models) were assessed by analysing the same radiographic image of a combined 13-step aluminium step wedge and the Artinis CDDent 1.0® (Artinis Medical Systems B.V.®, Elst, the Netherlands) test object. The number of steps and cylindrical objects observed on each monitor was recorded along with the monitor's make, model, position relative to the researcher's eye level, and proximity to the nearest window. The number of window panels blocked by blinds, the outside weather conditions, and the number of ceiling lights over the surgical suite/cubicle were also recorded. MedCalc® version 19.2.1 (MedCalc Software Ltd®, Ostend, Belgium, https://www.medcalc.org; 2020) was used for statistical analyses(Kruskal-Wallis test and stepwise regression analysis). The level of significance was set at P<0.05. Results: Stepwise regression analysis showed that only the monitor brand and proximity of the monitor to a window had a significant impact on the monitor's performance (P<0.05). The Kruskal-Wallis test showed significant differences (P<0.05) in monitor performance for all variables investigated, except for the weather and the clinic in which the monitors were placed. Conclusion: The vast performance variation present between computer monitors implies the need for a review of monitor selection, calibration, and viewing conditions.

노출지수를 이용한 요추 X선 촬영의 조사야 유효성 평가 (Effect of Field Size on the Clinical Exposure Index for Lumbar Spine X-ray Examination)

  • 박혜민;윤용수;김정수;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.183-187
    • /
    • 2021
  • The field size of the lumbar spine X-ray examination, which belongs to the most frequent examination in general radiography, is 5 times wider than the width of the lumbar spine. Exposure index (EI) as per International Electrotechnical Commission has a proportional relationship with the dose incident on the image receptor for clinical protocols in addition to RQA5, which is a calibration beam quality. In this study, the effectiveness of the set field size was evaluated through the change of EI according to the size of field during lumbar spine X-ray examinations. Lumbar anterior-posterior and lateral examinations was performed using a whole-body phantom, and the national average exposure conditions of Korea investigated in 2017 were introduced for the X-ray exposure. As a result of comparing the EI displayed on the console of digital radiography system for the three field size in ① 18 × 36 cm2 ② 25 × 36 cm2 ③ 36 × 36 cm2, the EI values showed a tendency to increase as the field size increased. Since the patient dose, such as organ dose around the lumbar spine, increases as the field size becomes larger, thus, if the EI obtained from the field size at a level that does not interfere with diagnosis is set as a reference, the effectiveness of the field size can be evaluated through the EI displayed on the console when the lumbar spine X-ray examination is conducted.