• 제목/요약/키워드: Calibration and Validation

검색결과 658건 처리시간 0.025초

근적외선 분광광도법을 이용한 PVC포장재 중 DEHP 정량법에 관한연구 (A method for quantitative analysis of DEHP in PVC packing material by Near-Infrared Spectroscopy)

  • 김재관;윤미혜;박포현;김기철
    • 환경위생공학
    • /
    • 제17권4호
    • /
    • pp.61-67
    • /
    • 2002
  • NIRS(Near infrared spectroscopy) scanning from 1300nm to 2400nm was appl ied for the DEHP(di-(2 ethylhexyl)phthalate) in PVC(polyvinyl chloride_packing material. All samples were devided into calibration group and validation group. As a result of conduction the multiple regression analysis on the correlation between the NIR spectrum data and chemical assay value obtained by the Korea Food Sanitation Act. The validation model for measuring the DEHP content had R of 0.997, SEC of 0.132, SEP of 0.176 by MLR and R of 0.996, SEC of 0.142, SEP of 0.198 by PLS and the detection limit was 0.1%. The obtained results indicate that the NIR procedure can potentially be used as a nondestructive analysis method for the purpose of rapid and simple measurement of DEHP in PVC packing material.

Validation, Measurement Uncertainty, and Determination of Bixin and Norbixin in Processed Foods of Animal Resources Distributed in Korea

  • Ga-Yeong Lee;Choong-In Yun;Juhee Cho;Young-Jun Kim
    • 한국축산식품학회지
    • /
    • 제43권6호
    • /
    • pp.949-960
    • /
    • 2023
  • This research aimed to validate a high-performance liquid chromatography method for the quantitative determination of bixin and norbixin in various foods. The Diode Array Detector (495 nm) technique was used. Method was validated for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy, and the measurement uncertainty was assessed. The calibration curve showed excellent linearity (r2≥0.9999) over the tested concentration range of 0.2-25 mg/L. The LOD and LOQ were 0.03-0.11 and 0.02-0.05 mg/L for bixin and norbixin, respectively. The intra-and inter-day accuracies and precisions were 88.0±1.3-97.0±0.5% and 0.2%-2.6% relative SD (RSD) for bixin and 88.2±0.8-105.8±0.8% and 0.3%-2.7% RSD for norbixin, respectively. Inter-laboratory validation for accuracy and precision was conducted in three laboratories, and these results all met the AOAC guidelines. In addition, the relative expanded uncertainty (<22%) satisfied the CODEX recommendation. Furthermore, products distributed in Korea were monitored for annatto extracts using the proposed method to demonstrate its application. The developed analytical method is reliable for quantifying bixin and norbixin in various foods.

다변량 분석법에 의한 Anionic Surfactant와 Nonionic Surfactant의 동시정량 (Simultaneous Determination of Anionic and Nonionic Surfactants Using Multivariate Calibration Method)

  • 이상학;권순남;손범목
    • 대한화학회지
    • /
    • 제47권1호
    • /
    • pp.19-25
    • /
    • 2003
  • 흡수 분광법에 의해 얻은 스펙트럼을 주성분분석(principal analysis, PCA) 으로 자료를 요약하여 주성분 회귀분서(principal component regression, PCR)과 부분 최소자승법(partial least squares, PLS)으로 음이온과 비이온 계면활성제(anionic and nonionic surfactant)를 동시에 정량하는 방법에 대하여 연구하였다. 두 가지 계면활성제가 서로 다른 농도로 혼합되어 있는 26개의 시료용액을 400~700 nm 범위에서 스펙트럼을 얻었고, 이를 이용하여 PCR과 PLS회귀모델을 얻었다. 두 가지 계면활성제가 서로 다른 농도로 포함된 5개의 외부검정용 시료들의 스펙트럼들을 이용해서 회귀모델의 적합성을 검정하기 위하여 외부검정용 시료의 농도를 계산하였다. 계산된 농도를 이용하여 relative standard error of prediction(RSEP$_{\alpha}$)를 구하여 회귀모델의 적합성을 검정하였다.

EVALUATION OF RAPID DETERMINATION OF PHOSPHORUS IN SOILS BY NIR SPECTROSCOPY

  • Ryu, Kwan-Shig;Kim, Book-Jin;Park, Jin-Sook
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1072-1072
    • /
    • 2001
  • The purpose of this research is to evaluate rapid determination of phosphorus in soils using NIR spectroscopy. The soil samples from the fields subject to different crops and land-use in Kyeongbook province, Korea were used to make the calibration and validation of the calibration set estimating phosphorus in soil. The NIR reflectance was scanned at 2nm intervals from 1100 to 2500nm with an InfraAlyzer 500 (Bran+Luebbe Co.). Various regression analyses were used to evaluate a NIRS method for determination of phosphorus in the soil. NIR absorption approach requires many soil samples to obtain optimal prediction. Applicability of NIR spectra technique may allow for the analysis of available soil phosphorus rapidly as well as total component within a few seconds.

  • PDF

정량분석을 통한 Eleutherococcus species의 HPLC 분석법 검증과 표준화 (Standardization of Eleutherococcus species and HPLC Method Validation for Quantitative Analysis)

  • 송미경;김미연;김호철
    • 대한본초학회지
    • /
    • 제26권1호
    • /
    • pp.103-110
    • /
    • 2011
  • Objective : For the standardization and quality control of eleutheroside E in Eleutherococcus species, HPLC analysis was performed and eleutherosdie E content was compared in 23 kinds of Eleutherococcus species collected from Korea and China. Methods : The content of eleutheroside E in stem bark of Eleutherococcus species collected from Korea and China were analyzed by HPLC. 0.5% phosphoric acid and acetonitrile was used as mobile solvent. Validation of HPLC analysis method was confirmed by analyzing specificity, linearity, precision and accuracy following ICH guideline. Results : Content of eleutheroside E was determined to be 1.0-1.6% and 0.5-0.8% in Korean and Chinese E. senticosus, respectively. Content of eleutheroside E in E. sessiliflorus was 0.7-1.1% and 0.2-0.4% respectively in Korean and Chinese origin. All calibration curves showed good linear regression. The method showed good precision and accuracy with intra-day and inter-day variations of 0.880-3.442% (RSD) and 0.606-3.328% (RSD), respectively, and average recovery was of 0.141-1.363% (RSD), for the eleutheroside E analyzed. Conclusion : These results might be used to establish a criterion of eleutheroside E in Eleutherococcus species.

Determination of Protein and Oil Contents in Soybean Seed by Near Infrared Reflectance Spectroscopy

  • Choung, Myoung-Gun;Baek, In-Youl;Kang, Sung-Taeg;Han, Won-Young;Shin, Doo-Chull;Moon, Huhn-Pal;Kang, Kwang-Hee
    • 한국작물학회지
    • /
    • 제46권2호
    • /
    • pp.106-111
    • /
    • 2001
  • The applicability of near infrared reflectance spectroscopy(NIRS) was tested to determine the protein and oil contents in ground soybean [Glycine max (L.) Merr.] seeds. A total of 189 soybean calibration samples and 103 validation samples were used for NIRS equation development and validation, respectively. In the NIRS equation of protein, the most accurate equation was obtained at 2, 8, 6, 1(2nd derivative, 8 nm gap, 6 points smoothing and 1 point second smoothing) math treatment condition with SNV-D (Standard Normal Variate and Detrend) scatter correction method and entire spectrum by using MPLS (Modified Partial Least Squares) regression. In the case of oil, the best equation was obtained at 1, 4, 4, 1 condition with SNV-D scatter correction method and near infrared (1100-2500nm) region by using MPLS regression. Validation of these NIRS equations showed very low bias (protein:-0.016%, oil : -0.011 %) and standard error of prediction (SEP, protein: 0.437%, oil: 0.377%) and very high coefficient of determination ($R^2$, protein: 0.985, oil : 0.965). Therefore, these NIRS equation seems reliable for determining the protein and oil content, and NIRS method could be used as a mass screening method of soybean seed.

  • PDF

Determination of Seed Lipid and Protein Contents in Perilla and Peanut by Near-Infrared Reflectance Spectroscopy

  • Oh, Ki-Won;Choung, Myoung-Gyun;Pae, Suk-Bok;Jung, Chan-Sik;Kim, Byung-Joo;Kwon, Yil-Chan;Kim, Jung-Tae;Kwack, Yong-Ho
    • 한국작물학회지
    • /
    • 제45권5호
    • /
    • pp.339-342
    • /
    • 2000
  • Near-infrared reflectance spectroscopy (NIRS) was used to estimate the lipid and protein contents in ground seed samples of perilla (Perilla frutescens Brit.) and peanut (Arachis hypogaea L.). A total of 46 perilla and 80 peanut calibration samples and 23 perilla and 46 pea. nut NIRS validation samples were used for NIRS equation development and validation, respectively. Validation of these NIRS equations showed a range of very low bias (-0.05 to 0.13 %) and standard error of prediction corrected for bias (0.224 to 0.803%) and very high coefficient of determination ($R^2$) (0.962 to 0.985). It was concluded that NIRS could be adapted as a mass screening method for lipid and protein contents in perilla and peanut seed.

  • PDF

Simulation and Model Validation of a Parabolic Trough Solar Collector for Water Heating

  • Euh, Seung-Hee;Kim, Dae Hyun
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.17-26
    • /
    • 2013
  • The aim of this study is to analyze the performance of a parabolic trough solar collector (PTC) for water heating and to validate the model performance. The simulated model was compared, calibrated and verified with the experimental results. RMSE (Root mean square error) was used to calibrate the convective heat transfer coefficient between the absorber pipe and the ambient air which was the main factor affecting the heat transfer associated with the PTC. The calibrated model was better fitted with the experimental model. The maximum, minimum and mean deviation between the measured and predicted water temperatures differed only $0.81^{\circ}C$, $0.09^{\circ}C$ and $0.31^{\circ}C$ respectively in the calibrated model. RMSE values were decreased from 0.5389 to 0.4910, 0.0134 to 0.0125 and R-squared was increased from 0.9955 to 0.9956 after calibration. The temperature of water was increased from $33.7^{\circ}C$ to $48^{\circ}C$ in 12hour test. The thermal efficiency of the collector was calculated to be 55%. The calibrated model showed good agreement with the experimental data for model validation.

LC-MS/MS를 이용한 반려동물 사료에서 곰팡이독소 동시분석법 유효성 확인 (Validation of simultaneous mycotoxin analysis method in pet food using LC-MS/MS)

  • 최윤화;안우석;김지은;김두환
    • 한국동물위생학회지
    • /
    • 제45권3호
    • /
    • pp.237-242
    • /
    • 2022
  • The simultaneous analysis of mycotoxins using LC-MS/MS, a food official analysis method, was applied with compound feed for pets with high consumer preferences. In this study, the linearity of all calibration curves showed good linearity of 0.99 or more. and both the accuracy (recovery rate) and precision (repeatability) criteria of the concentration range for each mycotoxin in the National Agricultural Products Quality Management Service's Validation and Verification Guidelines were met. And as a result of analyzing FAPAS QCM in the same way, it was assesed that the z-scores of Aflatoxin B1, Ochratoxin A, Zearalenone, and Fumonisin B1, were within ±2 range. This study showed that the application of the food official analysis method to compound feed for pets is suitable.

CGCM3 전지구모형에 의한 한반도 미래 일평균 풍속의 평가 (Estimation of Future Daily Wind Speed over South Korea Using the CGCM3 Model)

  • 함희정
    • 산업기술연구
    • /
    • 제33권A호
    • /
    • pp.41-48
    • /
    • 2013
  • A statistical downscaling methodology has been developed to investigate future daily wind speeds over South Korea. This methodology includes calibration of the statistical downscaling model by using large-scale atmospheric variables encompassing NCEP/NCAR reanalysis data, validation of the model for the calibration period, and estimation of the future wind speed based on the general circulation model (GCM) outputs of scenario A1B of the CGCM3. Based on the scenario A1B of the CGCM3 model, the potential impacts of climate change on the daily surface wind speed is relatively small (+/- 1m/s) in South Korea.

  • PDF