• Title/Summary/Keyword: Calibration Standard

Search Result 1,155, Processing Time 0.049 seconds

Simultaneous Determination of B Group Vitamins in Supplemented Food Products by High Performance Liquid Chromatography-Diode Array Detection

  • Suh, Joon-Hyuk;Yang, Dong-Hyug;Lee, Byung-Kyu;Eom, Han-Young;Kim, Un-Yong;Kim, Jung-Hyun;Lee, Hye-Yeon;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2648-2656
    • /
    • 2011
  • A simple HPLC-DAD method was developed and validated to determine B group vitamin content (thiamine, riboflavin, nicotinamide, pantothenic acid, pyridoxine and folic acid) in supplemented food samples, i.e., infant formula, cereal, low-calorie food, a multi-vitamin pill and a vitamin drink. In this study, the most significant advantages were simultaneous determination of the six B group vitamins in various food matrices and a small number of sample treatment steps that required only an organic solvent, acetonitrile. Moreover, this method prevents reduction of column durability, because the mobile phase does not contain ion-pairing reagents. Analytes were separated on a Develosil RPAQUEOUS $C_{30}$ (4.6 mm ${\times}$ 250 mm, 5 ${\mu}M$ particle size) column with a gradient elution of acetonitrile and 20 mM phosphate buffer (pH 3.0) at a flow rate between 0.8 and 1.0 mL/min. Detection was performed at 275 nm, except for that of pantothenic acid (205 nm). The calibration curves for all six vitamins showed good linearity with correlation coefficients ($r^2$) higher than 0.995. The developed method was validated with respect to linearity, intra- and inter-day accuracy and precision, limit of quantification (LOQ), recovery and stability. The method showed good precision and accuracy, with intra- and inter-assay coefficients of variation less than 15% at all concentrations. The recovery was carried out according to the standard addition procedure, with yields ranging from 89.8 to 104.4%. This method was successfully applied to the determination of vitamin B groups in supplemented food products.

Development of a force measurement device for curling sweeping with load cells (로드셀을 이용한 컬링 스위핑 힘 측정 장치 개발)

  • Lee, Sangcheol;Kim, Taewhan;Kil, Sekee;Choi, Sanghyup
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.49-56
    • /
    • 2017
  • Curling sweeping is one of important motion to control the position of the curling stone, and sweeping speed and applied force to the broom pad are major research subjects. In this study, a device was developed to measure the force applied to the curling broom pad in curling sweeping motion, and two load cells were mounted between the broom pad and pad holder. Analog signals generated from the load cells were sampled about 300 times per second using a micro controller, and then converted to 10-bit digital signals. Calibration of the load cell and set up of regression equations to convert the measured electrical signals into mass (force) was done by three M1 class weights, and the developed system was designed as wearable device to minimize increasing of total weight of the broom. Same force was applied to the developed system and a force plate that was using as a reference force measurement system in field of sports, and the difference between the measured values were showed about $0.909{\pm}1.375N$(mean and standard deviation). The developed system could be applied other kinds of study which required force measurement function similar to sweeping motion.

Measurement of soft tissue thickness on posterior palatal area by using computerized tomography in Korean population (전산화단층촬영법을 통한 한국인의 구개 저작 점막 두께에 대한 연구)

  • Song, Ji-Eun;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.1
    • /
    • pp.103-113
    • /
    • 2007
  • The purpose of this study was to measure the thickness of masticatory mucosa in the hard palate as a donor site for mucogingival surgery by using computerized tomography(CT), Thickness measurements were performed in 84 adult patients who took CT on maxilla for implant surgery and 24 standard measurement points were defined in the hard palate according to the gingival margin and mid palatal suture. Radiographic measurements were utilized after calibration for standardization. Data were analyzed to determine the differences in mucosal thickness by gender, age, tooth positions and depth of palatal vault. The results of this study were as follows: 1. Mean thickness of palatal masticatory mucosa was $3.93{\pm}0.6mm$ and females had significantly thinner mean masticatory mucosa($3.76{\pm}0.56mm$) than males($4.04{\pm}0.6mm$)(p<0.05). 2. The thickness of palatal masticatory mucosa increased by aging. 3. Depending on position, masticatory mucosa thickness increased from canine to premeolar, but decreased at the first molar, and increased again in the second molar region(p<0.0001). 4. No significant difference in mean thickness of palatal masticatory mucosa were indentified between low palatal vault group and high palatal vault group(p>0.05). The results suggest that canine and premolar area appears to be the most appropriate donor site for soft tissue grafting procedure. The measurement of the thickness of palatal masticatory mucosa by using computerized tomography can offer useful information clinically but further studies in as-sessing the validity and reliability of the method using computerized tomography is needed.

Measurement and Estimation for the Clearance of Radioactive Waste Contaminated with Radioisotopes for Medical Application (의료용 방사성폐기물 자체처분을 위한 방사능 측정 및 평가)

  • Kim, Changbum;Park, MinSeok;Kim, Gi-Sub;Jung, Haijo;Jang, Seongjoo
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • The amounts of radioactive wastes to be disposed in the medical institute have been increased due to development of radiation diagnosis and therapy rapidly. They are produced mostly by the very short lived radioisotopes such as $^{18}F$ used in PET/CT, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}Tl$, etc. IAEA proposed a criteria for the clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). Radioactive wastes of $^{18}F$, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}TI$ in the several types of container like Marinelli beaker, vial and plastic, were collected to measure the concentration of the waste of each nuclide in accordance with IAEA criteria. The measurement method and procedure of determining specific activity of the wastes using gamma emitters like MCA, gamma counter and beta emitters were developed. For the efficiency calibration of the detectors, CRM (certified reference material) which has the same dimension and shape was provided by Korea Research Institute of Standards and Science (KRISS). Correction factor of the radioactivity decay was calculated based on the measurement results, and the consideration of mutual relation with theoretical equation. The result of this study will be proposed as ISO standard.

Dose Distribution of Wedge filter by Dose Rate in LINAC (선형가속기의 선량율에 따른 쐐기필터의 선량분포)

  • Gwon, Taehyeong;Kim, Seunguk;Yoon, Yonghak;Won, Doyeon;Jeong, Kyeonghwan;Jung, Jaeeun;Cho, Juneho
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.323-329
    • /
    • 2015
  • This study is aimed at assessing whether dynamic wedge filters are appropriate to be used instead of physical wedge filters. The X-ray energy generated from linear accelerator is commercialize 6 MV and 10 MV. $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ of physical wedge filter was irradiated by dose rate 100, 200, 300, 400, 500, and 600 MU/min for each angle and for comparison with a dynamic wedge filter, irradiate 96 times under the same conditions. The measurement conditions are as 100 cm source-film distance and $10{\times}10cm$ irradiated surface. A developed film was scanned and analyzed after a calibration through a dose analysis program and the dose rate was compared after calculating the standard deviation. Dynamic wedge filters make dose, scattered rays and treatment time reduced and very useful due to less irradiated doses to patients. The errors at each dose rate under the same conditions were irrelevant. Thus, treatment based on a high dose rate depending on the patient is expected to be feasible.

Development of Profile Technique for Steam Generator Tubes in Nuclear Power Plants Using $8{\times}1$ Multi-Array Eddy Current Probe ($8{\times}1$ 다중코일 와전류탐촉자를 이용한 원전 증기발생기 전열관 단면형상검사 기법 개발)

  • Nam, Min-Woo;Lee, Hee-Jong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.184-190
    • /
    • 2008
  • Various ECT techniques have been applied basically to assess the integrity of steam generator tithing in nuclear power plant. Among these techniques, the bobbin probe technique is applied generally to examine the volumetric flaws such as a crack-like defect and wear which is generally occurred on steam generator tubing, and additionally MRPC probe is used to examine closely tile top of tubesheet and bending regions due to the high possibility of cracking. Dent and bulge also may be formed on tube during installation process and operation of steam generator, but the dent and bulge indications greater than specific size criteria are recorded on examination report because these indications are not considered as flaw. These indications can be easily detected with bobbin probe and approximately sized with profile bobbin probe, but the size and shape can not be accurately verified. Accordingly, in this study, the $8{\times}1$ multi-array EC probe was designed to increase the measurement accuracy of the sectional profiling EC testing of tube. As a result, we would like to propose the application of $8{\times}1$ multi-array EC probe for the measurement of size and shape of profile change on steam generator tube in OPR-1000 nuclear power plant.

Prediction from Linear Regression Equation for Nitrogen Content Measurement in Bentgrasses leaves Using Near Infrared Reflectance Spectroscopy (근적외선 분광분석기를 이용한 잔디 생체잎의 질소 함량 측정을 위한 검량식 개발)

  • Cha, Jung-Hoon;Kim, Kyung-Duck;Park, Dae-Sup
    • Asian Journal of Turfgrass Science
    • /
    • v.23 no.1
    • /
    • pp.77-90
    • /
    • 2009
  • Near Infrared Reflectance Spectroscopy(NIRS) is a quick, accurate, and non-destructive method to measure multiple nutrient components in plant leaves. This study was to acquire a liner regression equation by evaluating the nutrient contents of 'CY2' creeping bentgrass rapidly and accurately using NIRS. In particular, nitrogen fertility is a primary element to keep maintaining good quality of turfgrass. Nitrogen, moisture, carbohydrate, and starch were assessed and analyzed from 'CY2' creeping bentgrass clippings. A linear regression equation was obtained from accessing NIRS values from NIR spectrophotometer(NIR system, Model XDS, XM-1100 series, FOSS, Sweden) programmed with WinISI III project manager v1.50e and ISIscan(R) (Infrasoft International) and calibrated with laboratory values via chemical analysis from an authorized institute. The equation was formulated as MPLS(modified partial least squares) analyzing laboratory values and mathematically pre-treated spectra. The accuracy of the acquired equation was confirmed with SEP(standard error of prediction), which indicated as correlation coefficient($r^2$) and prediction error of sample unacquainted, followed by the verification of model equation of real values and these monitoring results. As results of monitoring, $r^2$ of nitrogen, moisture, and carbohydrate in 'CY2' creeping bentgrass was 0.840, 0.904, and 0.944, respectively. SEP was 0.066, 1.868, and 0.601, respectively. After outlier treatment, $r^2$ was 0.892, 0.925, and 0.971, while SEP was 0.052, 1.577, and 0.394, respectively, which totally showed a high correlation. However, $r^2$ of starch was 0.464, which appeared a low correlation. Thereof, the verified equation appearing higher $r^2$ of nitrogen, moisture, and carbohydrate showed its higher accuracy of prediction model, which finally could be put into practical use for turf management system.

Simultaneous Determination of Tetracycline Antibiotics by 3-Phase Hollow Fiber-Liquid Phase Microextraction (HF-LPME) and HPLC-UV/Vis (3-상 속빈 섬유-액체상 미량추출법(HF-LPME)과 HPLC-UV/Vis을 이용한 Tetracycline류 항생제 동시분석)

  • Oh, Woong Kyo;Myung, Seung-Woon
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.6
    • /
    • pp.535-542
    • /
    • 2014
  • A simple and efficient preconcentration method was developed using three-phase liquid phase microextraction prior to HPLC-UV for simultaneous extraction and determination of tetracycline antibiotics (tetracycline, oxytetracycline, and chlortetracycline). The tetracycline antibiotics were separated simultaneously on a column ($C_8$, $3.0{\times}150mm$, $3{\mu}m$) with high selectivity and sensitivity using gradient elution. Under optimized conditions (extraction solvent, heptanal; pH of donor, 9.0; pH of acceptor, 1.0; stirring speed, 700 rpm; NaCl salt, 0%; and extraction time, 60 min), enrichment factors (EF) were between 5.6 and 22.3. The limit of detection (LOD) and limit of quantitation (LOQ) in the spiked urine matrix were in the concentration range of $0.08{\sim}0.8{\mu}g/mL$ and $0.4{\sim}1.6{\mu}g/mL$, respectively. The calibration curves were linear within the range of $0.1{\sim}32{\mu}g/mL$ with the square of the correlation coefficient being more than 0.995. The precision (as a relative standard deviation, RSD) and accuracy (as a relative recovery) within working range were 1.3~9.1% and 84~118%, respectively.

Simultaneous Analysis of Antimicrobial Three Straight Chain 1,2-alkanediols in Cosmetics by Gas Chromatography (가스크로마토그래피를 이용한 화장품 중 항균작용의 3종의 직쇄상 1,2-알칸디올류의 동시분석)

  • Lee, Hoo Seob;Lee, Sang Hun;Kim, Eun Juk;Chung, Cheol Hee;Pyo, Hyeong Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.1
    • /
    • pp.37-44
    • /
    • 2014
  • Preservatives such as paraben, phenoxyethanol, and chlorphene are commonly used in cosmetics thanks to cheap price and good antiseptic effect. Recently, consumers' concerns about their possible toxicity and skin irritation forced them to be replaced with straight 1,2-alkanediols. However, as the alkanediols may also irritate skin, limited amount of them should be used in cosmetics. Three 1,2-alkanediols including 1,2-pentanediol, 1,2-hexanediol, and 1,2-octanediol in cosmetics were analyzed simultaneously by gas chromatogrphy with flame ionization detector. As a result of method validation, the specificity was confirmed by the calibration curves of 1,2-pentanediol, 1,2-hexanediol, and 1,2-octanediol showing good linearity correlation coefficient of above 0.999 over the concentration range of $100{\sim}1,200{\mu}g/g$. The limit of detection (LOD) and quantification (LOQ) of 1,2-pentanediol, 1,2-hexanediol, and 1,2-octanediol were 31, 40, and $19{\mu}g/g$ and 98, 108, and $57{\mu}g/g$, respectively. The precision (Repeatability) of the amount in cosmetics showed less than 2.0%. Relative Standard Deviation (% RSD) and the Accuracy (% recovery) of the amount in cosmetics showed 99.3 ~ 103.3, 99.4 ~ 106.7, 97.5 ~ 107.3% respectively. As a result, simultaneous analysis of antimicrobial three 1,2-alkanediols in cosmetics were possible. This method can be utilized in accurate quantitative analysis of 1,2-alkanediols in cosmetics.

Development of Rapid Prediction Model of C3G Content in Black Pigmented Rice (흑자색미의 C3G 색소함량 신속 예측모델 개발)

  • Ryu Su-Noh;Yang Jong-Jin;Park Sun-Zik
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.spc1
    • /
    • pp.1-3
    • /
    • 2005
  • It has been reported that Cyanidin 3-Glu-coside (C3G) of the black pigmented rice was as the high anti-oxidency and analyzed by high performance liquid chromatography (HPLC). However, the analysis of C3G by HPLC is needed long pre-treated steps, so development of methods with simple pre-treated steps is needed in order to breed vices with high C3G contents. The analysis of components using near infrared reflectance (NIR) was well known as non pre-treated and nondestructive. C3G contents of Bengjinjubyeo$\times$Suwon425 $F_{10}$ 385 lines were used in order to develop C3G content prediction model in pigmented rice using FT-NIR. The results of C3G content of FT-NIR compared with HPLC were showed that the equation was f(x)=0.9427x+34.0430, $R^2$, standard error of calibration was 0.943, 0.116 and those of validation was 0.928, 0.122, respectively. This prediction model will be able to be used for analyzing C3G contents in black pigmented rice.