• Title/Summary/Keyword: Calibration Standard

Search Result 1,157, Processing Time 0.026 seconds

Determination of Trace Mo(VI) in Seawater Samples by Ion Pair Formation and Solvent Extraction (이온쌍 형성-용매추출에 의한 해수 중 극미량 Mo(VI)의 정량)

  • Kim, Young-Sang;Nho, Seung-Gu;Choi, Jong-Moon
    • Analytical Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.329-334
    • /
    • 1993
  • The formation of Mo(VI)-alizarin red S chelate ion its extraction into an organic solvent by ion-pairing for the separarive determination of trace Mo(VI) in natural water was applied in seawater samples. Removed Fe(III) and Zn(II), and Cu(II) by precipitating with anthranilic acid at pH 4.0 and 2.0, seawater 100mL was sampled in 250mL separatory funnel. After Mo(VI)-ARS chelate ion was formed by adding 0.01M alizarin red S solution 1.0mL to the water sample of pH 4.6, 0.6% aliquat-336 chloroform solution 10mL was added and the solution was vigorously shaked for about 30 seconds to form the ion-pair between Mo(VI)-ARS and aliquat-336 perfectly. The solution was stood for about 30 minutes. And the organic phase was taken for the absorbance measurement of the ion-pair at 520nm. The content of Mo(VI) was obtained from the standard calibration curve. Several extraction conditions such as pH, adding amounts of alizarin red S and aliquat-336, and shaking and standing times were optimized and the interferences and release of concomitant ions was also studied. This procedure was applied to the analysis of Eastern and Yellow seawaters. It could be confirmed from the recoveries of over 85% in samples spiked with a given amount of Mo(VI) that this method was also quantitative in the determination of trace Mo(VI) in a seawater.

  • PDF

Solvent Extraction of Trace Mo(VI) in Natural Water Samples by Chelation and Ion-pairing (킬레이트 및 이온쌍 형성을 이용한 자연수 중 극미량 Mo(VI)의 용매추출)

  • Kim, Young-Sang;Nho, Seung-Gu;Choi, Jong-Moon;Choi, Hee-Seon
    • Analytical Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.289-296
    • /
    • 1993
  • The formation of Mo(VI)-alizarin red S chelate ion and its extraction into an organic solvent by ion-pairing were studied for the separative determination of trace Mo(VI) in natural water samples. Natural water 100mL was sampled in 250mL separatory funnel. After Mo(VI)-ARS chelate ion was formed by adding 0.01M alizarin red S solution 0.5mL to the water sample of pH 4.0, 0.2% aliquat-336 chloroform solution 10mL was added and the solution was vigorously shaked for about 30 seconds to from the ion-pair between Mo(VI)-ARS and aliquat-336, completely. The solution was stood for about 90 minutes. And the organic phase was taken for the absorbance measurement of the ion-pair at 520 nm. The content of Mo(VI) in sample was obtained from the standard calibration curve. Several extraction conditions such as pH, adding amounts of alizarin red S and aliquat-336, and shaking and standing times were optimized. This procedure was applied to the analysis of river and tap waters. It could be confirmed from the recoveries of over 99% in samples spiked with a given amount of Mo(VI) that this method was quantitiative in the determination of trace Mo(VI) in a natural water.

  • PDF

Development of alternative assay method without hazardous reagent, carbon tetrachloride, for cefroxadine capsules in Korean Pharmaceutical Codex (세프록사딘 캡슐 시험에 사용되는 유해시약인 사염화탄소 대체 공정시험법 개발)

  • Seo, Narae;Kang, Yeoul;Park, Yeong Shin;Lee, Jong Min;Jeong, Myung Jin;Jeon, Sang Seol;An, Jae Hyung;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.161-166
    • /
    • 2014
  • Currently oxidation-reduction titration method for the assay method using the hazardous reagent, carbon tetrachloride, for cefroxadine capsules has been used in Korean Pharmaceutical Codex. We developed and validated an alternative HPLC assay method by substituting the use of the hazardous reagent, carbon tetrachloride, to the use of less toxic ones like acetonitrile. The linearity of the calibration curves in the desired concentration range was good ($r^2$ > 0.999). Relative standard deviations of intra-day precision were ranged between 0.30% and 0.69% and inter-day precision were ranged between 0.47% and 0.82%. Accuracy was obtained with recoveries in range of 100.20% and 100.56%. Developed method was applied to the determination of cefroxadine in commercial cefroxadine capsule and could be expected to become valuable tools for revising the Korean Pharmaceutical Codex.

Development of an Analytical Method for Chloropicrin Determination in Hulled Rice by GC-ECD and GC-MS (GC-ECD 및 GC-MS를 이용한 현미 중 chloropicrin의 잔류시험법 개발)

  • Do, Jung-Ah;Choi, Jeong-Heui;Park, Hyejin;Park, Yong-Chun;Yoon, Hae-Jung;Choi, Dongmi;Oh, Jae-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.222-226
    • /
    • 2013
  • A simple and sensitive analytical method was developed using gas chromatograph with electron capture detector (GC-ECD) and gas chromatograph-mass spectrometer (GC-MS) for determination and identification of chloropicrin. Because of small molecular weight and high volatile properties of chloropicrin, analytical method was developed utilizing headspace extraction and direct injection to the GC. The developed method was validated using hulled rice sample spiked with chloropicrin at different concentration levels, 0.1 and 0.5 mg/kg. Average recoveries of chloropicrin (using each concentration three replicates) ranged 77.7~79.3% with relative standard deviations less than 10% and calibration solutions concentration in the range $0.005{\sim}0.5{\mu}g/mL$, and limit of detection (LOD) and limit of quantification (LOQ) were 0.004 and 0.01 mg/kg, respectively. The result showed that developed analytical methods was successfully applied to detect a small amount of chloropicrin in hulled rice.

Standardization for Analysis Method of Total Polyphenol in Complex of Picao Preto (피카오프레토 등 복합물 중 총 폴리페놀 분석법 표준화)

  • Hu, Soojung;Kim, Ji-An;Moon, Myung-Hee;Lee, Sung-Hye;Yoon, Hae-Seong;Hong, Jin-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.1
    • /
    • pp.44-49
    • /
    • 2018
  • As generic health functional food items have been expanded, this research project has been conducted to prepare a scientific and systematic standardized analytical method of relevant food item and examine the suitability of the method for health/functional foods on sale. Total polyphenol was necessary for development and verification of standardized analytical method. The method exhibited high linearity in the tannic acid calibration curve ($r^2$ > 0.999) over concentrations of $5-50{\mu}g/mL$. The limits of detection and quantitation for tannic acid were $5{\mu}g/mL$ and $15{\mu}g/mL$, respectively, while tannic acid recovery was 102.3-112.4% with standard deviations of 0.8-3.2%. To verify the accuracy of the analytical method, the labeled amounts of purchased health functional foods were monitored. The recovery for tannic acid was 105.6% of the labeled amounts. Thus, the new method was suitable for all cases.

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

Prediction of the content of white clover and perennial ryegrass in fresh or dry mixtures made up from pure botanical samples, by near infrared spectroscopy

  • Blanco, Jose A.;Alomar, Daniel J.;Fuchslocher, Rita I.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1266-1266
    • /
    • 2001
  • Pasture composition, an important attribute determining sward condition and value, is normally assessed by hand separation, drying and measuring weight contribution of each species in the mixture. This is a tedious, time and labour consuming procedure. NIRS has demonstrated the potential for predicting botanical composition of swards, but most of the work has been carried out on dry samples. The aim of this work was to evaluate the feasibility of developing NIR models for predicting the white clover and ryegrass content in fresh or dry mixtures artificially prepared from pure samples of both species. Mixtures from pure stands of white clover(Trifolium repens) and perennial ryegrass (Lolium perenne) were prepared with different proportions (0 to 100%) of each species (fresh weight). A total of 55 samples were made (11 mixtures,5 cuts). Spectra (400 to 2500 nm) were taken from fresh chopped (rectangular cuvettes, transport sample module) samples, in a NIR Systems 6500 scanning monochromator controlled by the software NIRS 3 (Infrasoft International), which was also utilized for calibration development. Different math treatments (derivative order, subtraction gap and smooth segment) and a scatter correction treatment of the spectra (SNV and Detrend) were tested. Equations were developed by modified partial least squares. Prediction accuracy evaluated by cross-validation, showed that percentage of clover or ryegrass, as contribution in dry weight, can be successfully percentage of clover or ryegrass, as contribution in dry weight, can be successfully predicted either on fresh or dried samples, with equations developed by different math treatments. Best equations for fresh samples were developed including a first, second, or third derivative, whereas for dry samples best equations included a second or third derivative. Standard errors of ross validation were about 6% for fresh and 3.6% for dry samples, Coefficient of determination of cross validation (1-VR) were over 0.95 times the value of SECV for fresh samples and over 8 times the value of SECV for dry samples. Scatter correction (SNV and Detrend) in general improved prediction accuracy. It is concluded more precise on dried and ground samples, it can be used with an acceptable error level and less time and labour, on fresh samples.

  • PDF

Effects of variety, region and season on near infrared reflectance spectroscopic analysis of quality parameters in red wine grapes

  • Esler, Michael B.;Gishen, Mark;Francis, I.Leigh;Dambergs, Robert G.;Kambouris, Ambrosias;Cynkar, Wies U.;Boehm, David R.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1523-1523
    • /
    • 2001
  • The wine industry requires practical methods for objectively measuring the composition of both red wine grapes on the vine to determine optimal harvest time; and of freshly harvested grapes for efficient allocation to vinery process streams for particular red wine products, and to determine payment of contract grapegrowers. To be practical for industry application these methods must be rapid, inexpensive and accurate. In most cases this restricts the analyses available to measurement of TSS (total soluble solids, predominantly sugars) by refractometry and pH by electropotentiometry. These two parameters, however, do not provide a comprehensive compositional characterization for the purpose of winemaking. The concentration of anthocyanin pigment in red wine grapes is an accepted indicator of potential wine quality and price. However, routine analysis for total anthocyanins is not considered as a practical option by the wider wine industry because of the high cost and slow turnaround time of this multi-step wet chemical laboratory analysis. Recent work by this ${group}^{l,2}$ has established the capability of near infrared (NIR) spectroscopy to provide rapid, accurate and simultaneous measurement of total anthocyanins, TSS and pH in red wine grapes. The analyses may be carried out equally well using either research grade scanning spectrometers or much simpler reduced spectral range portable diode-array based instrumentation. We have recently expanded on this work by collecting thousands of red wine grape samples in Australia. The sample set spans two vintages (1999 and 2000), five distinct geographical winegrowing regions and three main red wine grape varieties used in Australia (Cabernet Sauvignon, Shiraz and Merlot). Homogenized grape samples were scanned in diffuse reflectance mode on a FOSE NIR Systems6500 spectrometer and subject to laboratory analysis by the traditional methods for total anthocyanins, TSS and pH. We report here an analysis of the correlations between the NIR spectra and the laboratory data using standard chemometric algorithms within The Unscrambler software package. In particular, various subsets of the total data set are considered in turn to elucidate the effects of vintage, geographical area and grape variety on the measurement of grape composition by NIR spectroscopy. The relative ability of discrete calibrations to predict within and across these differences is considered. The results are then used to propose an optimal calibration strategy for red wine grape analysis.

  • PDF

Near infrared spectroscopy for classification of apples using K-mean neural network algorism

  • Muramatsu, Masahiro;Takefuji, Yoshiyasu;Kawano, Sumio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1131-1131
    • /
    • 2001
  • To develop a nondestructive quality evaluation technique of fruits, a K-mean algorism is applied to near infrared (NIR) spectroscopy of apples. The K-mean algorism is one of neural network partition methods and the goal is to partition the set of objects O into K disjoint clusters, where K is assumed to be known a priori. The algorism introduced by Macqueen draws an initial partition of the objects at random. It then computes the cluster centroids, assigns objects to the closest of them and iterates until a local minimum is obtained. The advantage of using neural network is that the spectra at the wavelengths having absorptions against chemical bonds including C-H and O-H types can be selected directly as input data. In conventional multiple regression approaches, the first wavelength is selected manually around the absorbance wavelengths as showing a high correlation coefficient between the NIR $2^{nd}$ derivative spectrum and Brix value with a single regression. After that, the second and following wavelengths are selected statistically as the calibration equation shows a high correlation. Therefore, the second and following wavelengths are selected not in a NIR spectroscopic way but in a statistical way. In this research, the spectra at the six wavelengths including 900, 904, 914, 990, 1000 and 1016nm are selected as input data for K-mean analysis. 904nm is selected because the wavelength shows the highest correlation coefficients and is regarded as the absorbance wavelength. The others are selected because they show relatively high correlation coefficients and are revealed as the absorbance wavelengths against the chemical structures by B. G. Osborne. The experiment was performed with two phases. In first phase, a reflectance was acquired using fiber optics. The reflectance was calculated by comparing near infrared energy reflected from a Teflon sphere as a standard reference, and the $2^{nd}$ derivative spectra were used for K-mean analysis. Samples are intact 67 apples which are called Fuji and cultivated in Aomori prefecture in Japan. In second phase, the Brix values were measured with a commercially available refractometer in order to estimate the result of K-mean approach. The result shows a partition of the spectral data sets of 67 samples into eight clusters, and the apples are classified into samples having high Brix value and low Brix value. Consequently, the K-mean analysis realized the classification of apples on the basis of the Brix values.

  • PDF

The Construction of 3D Spatial Imagery Information of Dam reservoir using LiDAR and Multi Beam Echo Sounder (LiDAR와 MBES를 이용한 댐 저수지 3차원 공간영상정보 구축)

  • Lee, Geun-Sang;Choi, Yun-Woong
    • Spatial Information Research
    • /
    • v.18 no.3
    • /
    • pp.1-11
    • /
    • 2010
  • Recently, the construction of three dimensional spatial information of Dam reservoir area is very important part in Dam management work such as sediment survey, but it is difficult to acquire detailed terrain data because totalstation and single beam echo sounder are applied to terrain survey. This study presented method to construct detailed terrain data of Dam reservoir area using LiDAR and multi beam echo sounder. First, LiDAR survey was carried out in land zone and calibration process was applied by ground control point. And also the DEM of land zone was constructed by using algorithm, which eliminated building and vegetation class. As the result of validation of LiDAR DEM using GPS terrain survey, it was possible to construct three dimensional terrain data that was satisfied with the tolerance error of LiDAR, which was the standard error of LiDAR DEM showed as 0.108m. Also multi beam echo sounder was applied to the survey of water zone and it could construct spatial information that was satisfied with bathymetry surveying tolerance error of International Hydrographic Organization by validation with terrain survey data. And LiDAR and multi beam echo sounder data were integrated and it was possible to construct three dimensional spatial imagery information that can be applied to Dam management work such as the estimation of sediment amounts or the monitoring of terrain change by linking with high resolution orthophoto.