• Title/Summary/Keyword: Calibration Site

Search Result 192, Processing Time 0.024 seconds

A Study on Runoff Properties of Non-point Pollutant in Nakdong watershed by using SWAT model (SWAT 모형을 이용한 낙동강 하구언의 비점오염물질 유출특성 규명)

  • Lee, Eun-Jeong;Choi, Kyoung-Sik;Kim, Tae-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.815-823
    • /
    • 2012
  • Non-point source pollutants in down stream of Nakdong river were simulated by SWAT. GIS was utilized to make input data of SWAT such as landuse pattern and soil. Meteorological data of 2007 and 2009 were applied for the calibration and validation of runoff in SWAT. It was difficult to calibrate and validate the runoff and nutrient results since a study area was influenced by the tidal effects. Jindong site was selected to escape from the bias of runoff simulation in the coastal area. $R^2$ values of calibration and validation were 0.8 and 0.79. However, $R^2$ values of water qualities were very low level in comparison to runoff. These resulted from the concentration scale of water qualities such as BOD, T-N and T-P. Additionally, tidal influence could effected on the measurements of nutrients. The simulated annual averages and patterns of BOD, T-N and T-P in SWAT were similar to the measurement data. 80 ~ 96 % of nonpoint source pollutants at Nakbon M site were released from April to August of 2009. The ratio of T-N and T-P from nonpoint source were above 50 % during the rainy season.

The result of KOMPSAT-5 Calibration site simulation (1st) (KOMPSAT-5 검보정 site 시뮬레이션 결과 (1차))

  • Lee, Dong-Han;Shin, Jae-Min;Jung, Ho-Ryung;Seo, Doo-Chun;Song, Jeong-Heon;Choi, Myung-Jin;Yoon, Jae-Chul;Jung, Ok-Chul;Lim, Hyo-Suk
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.35-38
    • /
    • 2008
  • 2010년 발사 예정인 다목적위성 5호의 주 탑재체는 SAR (Synthetic Aperture Radar)이다. 다목적위성 5호의 영상자료 품질을 확보하기 위해 SAR 영상자료에 대한 발사 후 검보정이 현재 한국항공우주연구원에서 준비 작업이 진행 중이다. 본 논문에서는 다목적 위성 5호 검보정 준비 작업 중에서 검보정 site에 대한 시뮬레이션 결과에 대해 설명하고자 한다. SAR 위성 검보정 작업을 위해서는 Corner Reflector가 필수 검보정 장비이고, Corner Reflector(CR)를 다목적위성 5호 beam들의 incidence angle에 따라 적절한 개수를 적절한 위치에 검보정 site 요구조건을 만족하는 위치에 배치해야한다. 한반도내에 15개의 CR들을 가장 요구조건에 만족할 수 있는 적절한 위치에 배치한 후에, 다목적위성 5호의 검보정 site에 대한 시뮬레이션을 수행해 본 결과, 15개의 CR만으로는 다목적위성 5호의 beam들을 모두 검보정할 수 없다는 것을 확인할 수 있었다. 결론적으로 검보정 site 요구조건을 좀 더 만족하고 CR의 개수를 30개 이상 배치할 수 있는 몽고 등의 외국 지역까지 확인해 볼 필요성이 있다.

  • PDF

Design of Calibration and Validation Area for Forestry Vegetation Index from CAS500-4 (농림위성 산림분야 식생지수 검보정 사이트 설계)

  • Lim, Joongbin;Cha, Sungeun;Won, Myoungsoo;Kim, Joon;Park, Juhan;Ryu, Youngryel;Lee, Woo-Kyun
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.3
    • /
    • pp.311-326
    • /
    • 2022
  • The Compact Advanced Satellite 500-4 (CAS500-4) is under development to efficiently manage and monitor forests in Korea and is scheduled to launch in 2025. The National Institute of Forest Science is developing 36 types of forestry applications to utilize the CAS500-4 efficiently. The products derived using the remote sensing method require validation with ground reference data, and the quality monitoring results for the products must be continuously reported. Due to it being the first time developing the national forestry satellite, there is no official calibration and validation site for forestry products in Korea. Accordingly, the author designed a calibration and validation site for the forestry products following international standards. In addition, to install calibration and validation sites nationwide, the authors selected appropriate sensors and evaluated the applicability of the sensors. As a result, the difference between the ground observation data and the Sentinel-2 image was observed to be within ±5%, confirming that the sensor could be used for nationwide expansion.

Computer Vision Based Measurement, Error Analysis and Calibration (컴퓨터 시각(視覺)에 의거한 측정기술(測定技術) 및 측정오차(測定誤差)의 분석(分析)과 보정(補正))

  • Hwang, H.;Lee, C.H.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • When using a computer vision system for a measurement, the geometrically distorted input image usually restricts the site and size of the measuring window. A geometrically distorted image caused by the image sensing and processing hardware degrades the accuracy of the visual measurement and prohibits the arbitrary selection of the measuring scope. Therefore, an image calibration is inevitable to improve the measuring accuracy. A calibration process is usually done via four steps such as measurement, modeling, parameter estimation, and compensation. In this paper, the efficient error calibration technique of a geometrically distorted input image was developed using a neural network. After calibrating a unit pixel, the distorted image was compensated by training CMLAN(Cerebellar Model Linear Associator Network) without modeling the behavior of any system element. The input/output training pairs for the network was obtained by processing the image of the devised sampled pattern. The generalization property of the network successfully compensates the distortion errors of the untrained arbitrary pixel points on the image space. The error convergence of the trained network with respect to the network control parameters were also presented. The compensated image through the network was then post processed using a simple DDA(Digital Differential Analyzer) to avoid the pixel disconnectivity. The compensation effect was verified using known sized geometric primitives. A way to extract directly a real scaled geometric quantity of the object from the 8-directional chain coding was also devised and coded. Since the developed calibration algorithm does not require any knowledge of modeling system elements and estimating parameters, it can be applied simply to any image processing system. Furthermore, it efficiently enhances the measurement accuracy and allows the arbitrary sizing and locating of the measuring window. The applied and developed algorithms were coded as a menu driven way using MS-C language Ver. 6.0, PC VISION PLUS library functions, and VGA graphic functions.

  • PDF

A Study on the Development of CCTV Camera Autonomous Posture Calibration Algorithm for Simultaneous Operation of Traffic Information Collection and Monitoring (교통정보 수집 및 감시 동시운영을 위한 CCTV 카메라 자율자세 보정 알고리즘 개발에 관한 연구)

  • Jun Kyu Kim;Jun Ho Jung;Hag Yong Han;Chi Hyun SHIN
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.1
    • /
    • pp.115-125
    • /
    • 2023
  • This paper relates to the development of CCTV camera posture calibration algorithm that can simultaneously collect traffic information such as traffic volume and speed in the state of view of the CCTV camera set for traffic monitoring. The developed autonomous posture calibration algorithm uses vehicle recognition and tracking techniques to identify the road, and automatically determines the angle of view for the operator's traffic surveillance and traffic information collection. To verify the performance of the proposed algorithm, a CCTV installed on site was used, and the results of the angle of view automatically calculated by the autonomous posture calibration algorithm for the angle of view set for traffic surveillance and traffic information collection were compared.

Experiment of KOMPSAT-3/3A Absolute Radiometric Calibration Coefficients Estimation Using FLARE Target (FLARE 타겟을 이용한 다목적위성3호/3A호의 절대복사 검보정 계수 산출)

  • Kyoungwook Jin;Dae-Soon Park
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1389-1399
    • /
    • 2023
  • KOMPSAT-3/3A (K3/K3A) absolute radiometric calibration study was conducted based on a Field Line of sight Automated Radiance Exposure (FLARE) system. FLARE is a system, which has been developed by Labsphere, Inc. adopted a SPecular Array Radiometric Calibration (SPARC) concept. The FLARE utilizes a specular mirror target resulting in a simplified radiometric calibration method by minimizing other sources of diffusive radiative energies. Several targeted measurements of K3/3A satellites over a FLARE site were acquired during a field campaign period (July 5-15, 2021). Due to bad weather situations, only two observations of K3 were identified as effective samples and they were employed for the study. Absolute radiometric calibration coefficients were computed using combined information from the FLARE and K3 satellite measurements. Comparison between the two FLARE measurements (taken on 7/7 and 7/13) showed very consistent results (less than 1% difference between them except the NIR channel). When additional data sets of K3/K3A taken on Aug 2021 were also analyzed and compared with gain coefficients from the metadata which are used by current K3/K3A, It showed a large discrepancy. It is assumed that more studies are needed to verify usefulness of the FLARE system for the K3/3A absolute radiometric calibration.

Calibration and Validation System for Synthetic Aperture Radar Satellite (영상레이더 위성을 위한 검보정 시스템)

  • Shin, Jae-Min;Jeong, Ho-Ryung;Lee, Kwang-Jae
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.8 no.2
    • /
    • pp.98-104
    • /
    • 2010
  • The demand for Satellite Images is continuously increasing owing to the various applications of optical satellite images. However, the acquisition of optical images has a limitation due to problems of weather and day & night. because an optical satellite makes images with reflections of sunlight. Therefore, SAR Satellite, which uses electromagnetic waves to make an image, gives increased demand to various applications. It also makes increased interest. In this paper, a calibration and validation system, which is an essential element for high quality Radar images, is studied.

  • PDF

A Study on Airborne LiDAR System Calibration and Accuracy Evaluation (항공LiDAR 시스템 검정 및 정확도 평가 연구)

  • Choi, Yun-Soo;Kong, In-Ku;Lee, Kang-Won
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.4
    • /
    • pp.359-366
    • /
    • 2005
  • Airborne LiDAR integrated with on-board GPS/INS and scanning technology is a state-of the-art system for direct 3D geo-spatial data acquisition. In this study, LiDAR data were calibrated using ground points in calibration site for the higher system accuracy. The accuracy results are ${\pm}15{\sim}30\;cm$ in horizontal and ${\pm}15\;cm$ in vertical. The results show that LiDAR system has capability for precise DEM and contour generation, 3D urban modeling and engineering design.

PMCR-A Power Mapping and Calibration Routing for 600 MWe CANDU-PHW Reactors

  • Oh, Se-Ki;G.Kugler
    • Nuclear Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.275-286
    • /
    • 1979
  • In 600 MWe CANDU-PHW reactors PMCR will be used on-site for calibration of the regional overpower system. PMCR will be executed off-line in one of the station computers. The program calculates accurate channel power maps by incorporating a fuel turnup dependent flux to power conversion algorithm. Fuel turnup is calculated by PMCR, hence it is independent of other software. Extensive comparisons with the uniform flux/power conversion approximations were made. Significant improvements in power mapping accuracy are achieved with PMCR.

  • PDF

Preliminary Study for Image-Based Measurement Model in a Construction Site (이미지 기반 건설현장 수치 측정 모델 기초연구)

  • Yoon, Sebeen;Kang, Mingyun;Kim, Chang-Won;Lim, Hyunsu;Yoo, Wi Sung;Kim, Taehoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.287-288
    • /
    • 2023
  • The inspection work at construction sites is one of the important supervisory tasks, which involves verifying that the building is being constructed by the numerical values specified in the design drawings. The conventional measuring method for inspection involves using tools or equipment such as rulers directly by the personnel at the site, and it is usually confirmed by vision. Therefore, this study proposes an model to measure numerical values on images of the construction site. Through the case study to measure the installation interval of jack supports, the proposed algorithm was verified the effiect and validity. The results of this study suggest that it can support inspection work even in the office, which may have been overlooked by on-site inspectors, and contribute to the digitization of inspection work at construction sites.

  • PDF