• Title/Summary/Keyword: Calibration Interval

Search Result 97, Processing Time 0.023 seconds

Development of the automatic calibration system for industrial resistance thermometers at low temperatures (산업용 저항 온도계의 저온 자동 비교 교정 시스템 개발)

  • Yang, In-Seok;Song, Chang-Ho;Kang, Kee-Hoon;Kim, Yong-Gyoo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.429-436
    • /
    • 2008
  • A system is designed and fabricated for the automatic low temperature calibration by comparison of industrial resistance thermometers. The cryostat is suitable for the calibration of four capsule type thermometers and four long stem thermometers. By the automatic temperature control of the cryostat, we could calibrate thermometers from $-200^{\circ}C$ to $0^{\circ}C$ for ${\sim}15$ hours by one fill of liquid nitrogen in the test run of the system. The uncertainty of the calibration for industrial platinum resistance thermometers using the automatic system is about 30mK with a 95.% confidence interval.

등시지각 색 샘플링을 기반한 CIEL*a*b*-CMY 비선형 색변환

  • 오현수;이을환;유미옥;최환언;안석출
    • Proceedings of the Korean Printing Society Conference
    • /
    • 2000.12b
    • /
    • pp.5-10
    • /
    • 2000
  • In case of outputting the image with color printer, image is occurred color distortion by characteristics of paper, effect by overlap between neighbor dots and the mechanical characteristics if printer. Color calibration is needed to reduce this color distrotion. To color calibration, we select the color sample in printer color gamut. The accuracy of color calibration is determined by the number of sample, distribution, and calibration method. Generally, color space is selected the color sample dividing equal interval. In this case, the range of gamut of printed color patches is reduced due to the effect of inks overlap. Therefore, error is occurred when color transformation relatively. In this paper, we have the color sampling based on equi-visual perception and then reproduce the color using the Neural-Network and interpolation by LUT.

SHORT-TERM CALIBRATION OF MTSAT-1R SOLAR CHANNEL USING DESERT TARGETS

  • Chun, Hyoung-Wook;Sohn, Byung-Ju
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.426-429
    • /
    • 2008
  • In this study, we propose the calibration algorithm for the solar channel (550 ${\sim}$ 900 nm) of MTSAT 1R which is the Japanese geostationary satellite launched on 26 Feb. 2005 and located at $140^{\circ}E$. We developed a method utilizing MODIS-derived BRDFs for the solar channel calibration over the bright desert area. Targets are selected based on the desert's brightness, spatial uniformity, temporal stability and spectral stability. The 6S model has been incorporated to account for directional effects of the surface using MODIS-derived BRDF parameters within the spectral interval in interest. Results based on the analysis for the period from November 2007 to June 2008 suggest that MTSAT-1R solar channel measurements have a low bias within 5%.

  • PDF

Granulometric Analysis of Sediment: Preliminary Results for Inter-lab Calibration (퇴적물 입도분석 방식 비교: 예비결과)

  • Choi, J.Y.;Choi, J.H.;Kim, S.Y.
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.3
    • /
    • pp.246-253
    • /
    • 1999
  • Grain size distributions of sediment samples were analyzed by the different methods, and the results were compared. Reported data of the bottom sediments from the Korean seas show significant deviations among the institutes, and the inter-lab comparison and calibration procedures are considered to be necessary. Grain size data by different methods show different results. Laser diffraction method provides good precision in replicate analysis, but underestimates the amounts of finer (smaller than 2-3 ${\mu}m$) fraction. Data from particle settling method, on the other hand, represent significant errors in the coarse silt (5-6 ${\phi}$) fraction, and slightly overestimate the clay fraction. In the sieve and pipette methods, best results were taken in 0.5 ${\phi}$ interval of analysis. Especially in the coarse silt fraction, pipette analysis is suggested to be made with 0.5 ${\phi}$ interval. During the dry sieving procedure in 1 ${\phi}$ interval, serious errors occur when large amounts of sample materials were concentrated in a particular sieve.

  • PDF

Experimental investigation of flow parameters influencing the calibration of five-hole probes (5공프로우브의 보정에 영향을 주는 유동변수들에 대한 실험적 연구)

  • Lee, Sang-U;Yun, Tae-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.637-649
    • /
    • 1997
  • Effects of cone angle, pressure-hole orientation and Reynolds number on the five-hole probe calibration have been investigated for eight large-scale conical five-hole probes, which have either perpendicular pressure holes or forward-facing pressure holes for the cone angles of 45 deg, 60 deg, 75 deg and 90.deg. Pitch and yaw angles are changed from -40 deg to +40 deg with an interval of 5 deg, respectively, when the probe Reynolds numbers are 1.77*10$^{4}$, 3.53*10$^{4}$ and 7.06*10$^{4}$. The result shows that larger cone angle results in more sensitive changes in the calibration coefficients. In the case that the cone angle is 45 deg, the pitch-angle and yaw-angle coefficients of the five-hole probe with the perpendicular pressure holes show a very different trend compared with those of the five-hole probe with the forward-facing pressure holes. On the other hand, when the cone angle is more than 60 deg, each calibration coefficient is nearly independent of the pressure-hole orientation. Additionally, the effects of the Reynolds number on the calibration coefficients are also reported in detail.

Field Intercomparison and Calibration of Net Radiometers (순복사계의 야외 상호 비교 및 보정)

  • Byung-Kwan Moon;Sang-Boom Ryoo;Yong-Hoon Youn;Jonghwan Lim;Joon Kim
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.128-137
    • /
    • 2003
  • Net radiation (Rn) is one of the most fundamental components in surface energy budget. For an accurate measurement of Rn, periodic and consistent calibrations of net radiometers are required. With a 4-month time interval, two field experiments were conducted to inter-compare and calibrate two types of net radiometers (the Q-7.1 and the CNR1), widely used in flux measurements. Differences between the Q-7.1 and the CNR1 net radiometers were within 7.7%, and the errors after calibration against the standard net radiometer were <3.2%. Radiometric responses and calibration factors appeared to have changed with sky renditions, especially temperature difference with season's progress. We concluded that the periodically calibrated Q-7.1 can replace more expensive, more accurate CNR1 net radiometer for long-term field measurements, providing that field calibrations of net radiometers are performed every 4-6 months interval.

Variability of Calibration Factors for Open-Path CO2/H2O Infrared Gas Analyzer and Its Effect on Long-Term Flux Measurement (개회로 CO2/H2O 적외선 기체 분석기 보정 인자의 변동성과 장기 플럭스 관측에 미치는 영향)

  • Choi, Tae-jin;Yun, Jin-I.;Lim, Jong-Hwan;Park, Eun-Woo;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.2
    • /
    • pp.103-113
    • /
    • 2002
  • Calibration experiments were executed to document pertinent calibration methods for open-path infrared gas analyzer (OP-2) in field operations and to quantify their performance characteristics in continuous long-term flux measurements. Based on our results, we concluded: (1) flow rate of 2.0 L min$^{-1}$ can be used for calibration instead of the recommended 0.5 L min$^{-1}$ . Such faster flow rate brings the sampled air in the calibration hood at equilibrium within 5 min for $CO_2$ and 10 min for $H_2O$; (2) after reaching equilibrium, two-minute average sampling for related variables per each concentration may be sufficient; (3) use of four concentration is needed to derive the nonlinear calibration equation for water vapor with 1% uncertainty of flux measurement; and (4) the resultant calibration interval for OP-2 for both $CO_2$ and $H_2O$ is approximately one month.

The Effect of Reynolds Number on the Three-Dimensional Flow Measurements with a Two-Stage Cone-Type Five-Hole Probe in a Non-Nulling Mode (Reynolds 수가 2단 원추형 5공프로브를 이용한 3차원 유동 측정에 미치는 영향 - 저속 유동장에서의 보정 결과 -)

  • Lee, Sang-U;Jeon, Sang-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.1
    • /
    • pp.27-38
    • /
    • 2002
  • The effects of Reynolds number on the non-nulling calibrations of a cone-type ave-type probe in low-speed flows have been investigated at Reynolds numbers of 2.04$\times$10$^3$, 4.09$\times$10$^3$and 6.13$\times$10$^3$. The calibration is conducted at the pitch and yaw angles in ranges between -35 degrees and 35 degrees with an angle interval of 5 degrees. In addition to the calibration coefficients, reduced pitch and yaw angles, static and total pressures, and velocity magnitude are obtained through a typical non-nulling reduction procedure. The result shows that each calibration coefficient, in general, is a function of both the pitch and yaw angles, so that the pre-existing calibration data in a nulling mode are not enough in accounting far the full non-nulling calibration characteristics. Due to interference of the probe stem, the calibration coefficient are more sensitive to Reynolds number at positive pitch angles than at negative ones. The calibration data reduced in this study may serve as a guide line in the estimation of uncertainty intervals resulted from the Reynolds number effects at low Reynolds numbers.

Reynolds Number Effects on the Non-Nulling Calibration of a Cone-Type Five-Hole Probe for Turbomachinery Applications

  • Lee, Sang-Woo;Jun, Sang-Bae
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.8
    • /
    • pp.1632-1648
    • /
    • 2005
  • The effects of Reynolds number on the non-nulling calibration of a typical cone-type five-hole probe have been investigated for the representative Reynolds numbers in turbomachinery. The pitch and yaw angles are changed from - 35 degrees to 35 degrees with an angle interval of 5 degrees at six probe Reynolds numbers in range between $6.60{\times}10^3\;and\;3.17{\times}10^4$. The result shows that not only each calibration coefficient itself but also its Reynolds number dependency is affected significantly by the pitch and yaw angles. The Reynolds-number effects on the pitch- and yaw-angle coefficients are noticeable when the absolute values of the pitch and yaw angles are smaller than 20 degrees. The static-pressure coefficient is sensitive to the Reynolds number nearly all over the pitch- and yaw-angle range. The Reynolds-number effect on the total-pressure coefficient is found remarkable when the absolute values of the pitch and yaw angles are larger than 20 degrees. Through a typical non-nulling reduction procedure, actual reduced values of the pitch and yaw angles, static and total pressures, and velocity magnitude at each Reynolds number are obtained by employing the calibration coefficients at the highest Reynolds number ($Re=3.17{\times}10^4$) as input reference calibration data. As a result, it is found that each reduced value has its own unique trend depending on the pitch and yaw angles. Its general tendency is related closely to the variation of the corresponding calibration coefficient with the Reynolds number. Among the reduced values, the reduced total pressure suffers the most considerable deviation from the measured one and its dependency upon the pitch and yaw angles is most noticeable. In this study, the root-mean-square data as well as the upper and lower bounds of the reduced values are reported as a function of the Reynolds number. These data would be very useful in the estimation of the Reynolds-number effects on the non-nulling calibration.

DEVELOPING A VISIBLE CHANNEL CALIBRATION ALGORITHM FOR COMS OVER OCEAN AND DESERT TARGETS

  • Sohn, B.J.;Chun, Hyoung-Wook;Kim, Jung-Geun
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.53-56
    • /
    • 2007
  • The Korean Geostationary satellite (COMS) to fly in year 2009 will carry a meteorological sensor from which visible channel measurements will be available. We developed a method utilizing satellite-derived BRDFs for the solar channel calibration over the bright desert area. The 6S model has been incorporated to account for directional effects of the surface using MODIS-derived BRDF parameters within the spectral interval in interest. Simulated radiances over the desert targets were compared with MODIS and SeaWiFS measured spectral radiances in order to examine the feasibility of the developed calibration algorithm. We also simulated TOA radiance over ocean targets to verify the consistency and reliability of the result. It was shown that simulated 16-day averaged radiances are in good agreement with the satellite-measured radiances within about ${\pm}5%$ uncertainty range for the year 2005, suggesting that the developed algorithm can be used for calibrating the COMS visible channel within about 5% uncertainty level.

  • PDF