• 제목/요약/키워드: Calibration Correction

검색결과 369건 처리시간 0.032초

대형 평판 디스플레이의 정밀 정렬을 위한 캘리브레이션 기술 (Calibration Technology for Precise Alignment of Large Flat Panel Displays)

  • 홍준호;신동원
    • 한국기계가공학회지
    • /
    • 제21권3호
    • /
    • pp.100-109
    • /
    • 2022
  • In this study, calibration technology that increases the alignment accuracy in large flexible flat panels was studied. For precise of calibration, a systematization of the calibration algorithm was established, and a calibration correction technique was studied to revise calibration errors. A coordinate systems of camera and UVW stage was established to get the global position of the mark, and equations for translational and rotational calibration were systematically derived based on geometrical analysis. Correction process for the calibration data was carried, and alignment experiments were performed sequentially in cases of the presence or absence of calibration-correction. Alignment results of both calibration correction and non-calibration correction showed accuracy performance less than 1㎛. On the other hand, the standard deviation in calibration-correction is smaller than non-calibration correction. Therefore, calibration correction showed improvement of the alignment repeatability.

압전형 압력센서의 교정기법 자동화 (An automatic calibration technique for piezoelectric pressure transducers)

  • 홍성수;최주호;유준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1368-1371
    • /
    • 1996
  • This paper presents an automatic calibration technique for piezoelectric low pressure transducer, which is useful to measure a pressure within 500 psi. This system with automatic calibration function and error correction algorithm generates standard dynamic pressure for the calibration of sensor. With the compensation for the offset voltage and the pressure error, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

압전형 압력센서의 교정기법 자동화 (An Automatic Calibration Technique for Piezoelectric Pressure Transducers)

  • 홍성수;최주호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.1012-1016
    • /
    • 1996
  • This paper presents an automatic calibration technique for piezoelectic low pressure transducer, which is useful to measure a pressure within 500 psi. This system with automatic calibration function and error correction algorithm generates standard dynamic pressure for the calibration of sensor. With the compensation for the offset voltage and the pressure error, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

절차적 멀티카메라 기하 및 색상 정보 보정 툴킷 (Procedural Geometry Calibration and Color Correction ToolKit for Multiple Cameras)

  • Kang, Hoonjong;Jo, Dongsik
    • 한국정보통신학회논문지
    • /
    • 제25권4호
    • /
    • pp.615-618
    • /
    • 2021
  • Recently, 3D reconstruction of real objects with multi-cameras has been widely used for many services such as VR/AR, motion capture, and plenoptic video generation. For accurate 3D reconstruction, geometry and color matching between multiple cameras will be needed. However, previous calibration and correction methods for geometry (internal and external parameters) and color (intensity) correction is difficult for non-majors to perform manually. In this paper, we propose a toolkit with procedural geometry calibration and color correction among cameras with different positions and types. Our toolkit consists of an easy user interface and turned out to be effective in setting up multi-cameras for reconstruction.

In Orbit Radiometric Calibration Tests of COMS MI Infrared Channels

  • Jin, Kyoung-Wook;Seo, Seok-Bae
    • 대한원격탐사학회지
    • /
    • 제27권3호
    • /
    • pp.369-377
    • /
    • 2011
  • Since well-calibrated satellite data is critical for their applications, calibration and validation of COMS science data was one of the key activities during the IOT. COMS MI radiometric calibration process was divided into two phases according to the out-gassing of the sensor: calibrations of the visible (VI) and infrared (IR) channels. Different from the VIS calibration, the calibration steps for the IR channels followed additional processes to secure their radiometric performances. Primary calibration steps of the IR were scan mirror emissivity correction, midnight effect compensation, slope averaging and 1/f noise compensation after a nominal calibration. First, the scan mirror emissivity correction was conducted to compensate the variability of the scan mirror emissivity driven by the coating material on the scan mirror. Second, the midnight effect correction was performed to remove unreasonable high spikes of the slope values caused by the excessive radiative sources during the local midnight. After these steps, the residual (difference between the previous slope and the given slope) was filtered by a smoothing routine to eliminate the remnant random noises. The 1/f noise compensation was also carried out to filter out the lower frequency noises caused from the electronics in the Imager. With through calibration processes during the entire IOT period, the calibrated IR data showed excellent performances.

광 픽업 성능 평가기 캘리브레이션 (Calibration of an Optical Pick-up Performance Evaluator)

  • 류정래;도태용
    • 제어로봇시스템학회논문지
    • /
    • 제20권5호
    • /
    • pp.578-583
    • /
    • 2014
  • Optical pick-up is a core component for data read/write operations in optical disc drives, and an optical pick-up performance evaluator is an instrument used to analyze the overall performance of an optical pick-up. Due to inevitable errors in an analog measurement circuit, resultant evaluation data is not guaranteed to be accurate. In this paper, a calibration method for an optical pick-up performance evaluator is proposed to ensure evaluation accuracy. Measured data is corrected by a 1st order correction function, and a calibration process based on least-square method is utilized to obtain correction coefficients of the correction function. The proposed calibration method is applied to experiments, and enhanced accuracy is presented with resultant evaluation data.

사진측량 기법을 사용한 어안렌즈 왜곡보정에 관한 연구 (A Distortion Correction Method for the Fish-Eye Lens using Photogrammetric Techniques)

  • 강진아;박재민;김병국
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2007년도 춘계학술발표회 논문집
    • /
    • pp.161-164
    • /
    • 2007
  • The paper studies in the wide-angle lens and distortion tendency and employs the correction techniques suitable to the fish-eye lens using the existing photographic survey methods. After carrying out the calibration of the the fish-eye lens, we calculated the correction parameters, and then developed the method that convert the original image-point to new image-point correcting distortion. The objectives of suggested calibration method in this paper are to calibrate the image of the the fish-eye lens used in the computer-vision and the control-instrumentation field widely. The proposed technique expects to improve the accuracy of the image of the fish-eye lens in the indoor tracking and monitoring field. Also the referenced cross point auto-extraction program is embodied for improving efficiency of the lens correction techniques. Consequently, this calibration method would be applied to the automated distorting correction method on not only the fish-eye lens also general lens.

  • PDF

Evaluation of GSICS Correction for COMS/MI Visible Channel Using S-NPP/VIIRS

  • Jin, Donghyun;Lee, Soobong;Lee, Seonyoung;Jung, Daeseong;Sim, Suyoung;Huh, Morang;Han, Kyung-soo
    • 대한원격탐사학회지
    • /
    • 제37권1호
    • /
    • pp.169-176
    • /
    • 2021
  • The Global Space-based Inter-Calibration System (GSICS) is an international partnership sponsored by World Meteorological Organization (WMO) to continue and improve climate monitoring and to ensure consistent accuracy between observation data from meteorological satellites operating around the world. The objective for GSICS is to inter-calibration from pairs of satellites observations, which includes direct comparison of collocated Geostationary Earth Orbit (GEO)-Low Earth Orbit (LEO) observations. One of the GSICS inter-calibration methods, the Ray-matching technique, is a surrogate approach that uses matched, co-angled and co-located pixels to transfer the calibration from a well calibrated satellite sensor to another sensor. In Korea, the first GEO satellite, Communication Ocean and Meteorological Satellite (COMS), is used to participate in the GSICS program. The National Meteorological Satellite Center (NMSC), which operated COMS/MI, calculated the Radiative Transfer Model (RTM)-based GSICS coefficient coefficients. The L1P reproduced through GSICS correction coefficient showed lower RMSE and Bias than L1B without GSICS correction coefficient applied. The calculation cycles of the GSICS correction coefficients for COMS/MI visible channel are provided annual and diurnal (2, 5, 10, 14-day), but long-term evaluation according to these cycles was not performed. The purpose of this paper is to perform evaluation depending on the annual/diurnal cycles of COMS/MI GSICS correction coefficients based on the ray-matching technique using Suomi-NPP/Visible Infrared Imaging Radiometer Suite (VIIRS) data as reference data. As a result of evaluation, the diurnal cycle had a higher coincidence rate with the reference data than the annual cycle, and the 14-day diurnal cycle was the most suitable for use as the GSICS correction coefficient.

A 10-b 500 MS/s CMOS Folding A/D Converter with a Hybrid Calibration and a Novel Digital Error Correction Logic

  • Jun, Joong-Won;Kim, Dae-Yun;Song, Min-Kyu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2012
  • A 10-b 500 MS/s A/D converter (ADC) with a hybrid calibration and error correction logic is described. The ADC employs a single-channel cascaded folding-interpolating architecture whose folding rate (FR) is 25 and interpolation rate (IR) is 8. To overcome the disadvantage of an offset error, we propose a hybrid self-calibration circuit at the open-loop amplifier. Further, a novel prevision digital error correction logic (DCL) for the folding ADC is also proposed. The ADC prototype using a 130 nm 1P6M CMOS has a DNL of ${\pm}0.8$ LSB and an INL of ${\pm}1.0$ LSB. The measured SNDR is 52.34-dB and SFDR is 62.04-dBc when the input frequency is 78.15 MHz at 500 MS/s conversion rate. The SNDR of the ADC is 7-dB higher than the same circuit without the proposed calibration. The effective chip area is $1.55mm^2$, and the power dissipates 300 mW including peripheral circuits, at a 1.2/1.5 V power supply.

도로 위 숫자 및 기호 인식을 위한 광각렌즈 기반 Camera Calibration 연구

  • 강진규;홍형길;;;박강령;조형오
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 추계학술발표대회
    • /
    • pp.1406-1407
    • /
    • 2015
  • 본 논문에서는 도로 위 숫자 및 기호인식에 적합한 Calibration Model에 대하여 연구하였다. 기존에 제시된 Geometric Transform, Fisheye Projection, Caltech Toolbox 기반 방법으로 얻은 Calibration Model의 성능을 비교하였다. Geometric Transform은 Fisheye Distortion Correction에 부적합한 결과를 얻었고, Fisheye Projection은 성능은 좋으나 시스템에 사용할 Camera Lens의 Specification을 모르기 때문에 이를 예측해야 하는 단점이 있다. 마지막으로 Caltech Tool box 기반 방법은 Calibration을 위한 Keypoint를 수동으로 지정하다 보니까 이로 인한 오차가 존재하게 된다. Calibration을 시도 할 때마다 결과에 차이가 있었으며, Calibration 결과의 측면에서 Fisheye Projection이 가시적으로 가장 좋은 결과를 나타냈다.