• 제목/요약/키워드: Calculation Specifications

검색결과 80건 처리시간 0.027초

가변추진기 추진축계시스템의 설계 (제 I 보 : 외형설계 ) (Design of Propulsion Shafting System for Controllable Pitch Propeller (I : Latout Design with Sizing))

  • 김기인;전효중;박명규;김정렬
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.129-134
    • /
    • 2002
  • This study is focused on the layout design with sizing for the main propulsion shafting with controllable pitch propeller system. For appropriate design and successful manufacturing of controllable pitch Propeller system, it is based on specifications to be required from the customer as well as the stresses calculation and analysis of main propulsion system for hollow shafting. And it must be performed according to the U.S military specifications MIL-STD-2189(SH) with drawing of NAVSHIPS 803-2145807, and also the stress analysis by applying safety factor. The results are as follows : 1. For the main propulsion system with controllable pitch propeller, it is designed the following items propeller diameter, hub diameter, dimensions of oil distribution or actuating unit based on shaft mounting type, diameters of propeller and intermediate shaft, dimension of split muff coupling, coupling flange thickness and of coupling bolt diameter. 2. As the results, we can get complete our own design ability for the main propulsion shafting with controllable pitch propeller system with critical data which are necessary to establish shafting arrangement from the ship building companies.

  • PDF

남성 재킷 패턴 설계를 위한 30-44세 남성의 상반신 체형 및 유형별 사이즈 연구 (A study on the upper body type and size of men aged 30-44 for men jacket pattern design)

  • 권동국
    • 복식문화연구
    • /
    • 제29권6호
    • /
    • pp.881-903
    • /
    • 2021
  • This study aimed to analyze adult men's body sizes and shapes and suggest size specifications to provide preliminary data to academia and industries. A total of 814 adult men aged 30-44 were selected from the 7th Size Korea data, and 55 direct upper body measurement and calculation items were analyzed using SPSS 25.0. In individual Individual differences, thickness, circumference, and width were high, and height and length were low. Height above the waist base line and shoulder dimension decreased in early 40s age group, while height below the waist base line declined as age increased. In addition, buttocks shape changes were found in early 40s age group. According to factor analysis, 'upper body and upper-extremity horizontal size', 'torso height and upper extremity length', 'shoulder dimension', 'upper body length' and 'shoulder angle' were derived. Using clustering analysis, four different body types were classified: i) big abdomen with flat chest, ii) slender with big, raised shoulders, iii) dwarfish with small, droopy shoulders, and iv) obese with large shoulders. 'Slender with big, raised shoulders' was a typical body shape among men aged 30-44. In older participants, the 'big abdomen with flat chest' ratio was low, while 'obese with large shoulders' was more common. This study proposed size specifications by body type considering the above characteristics.

드론을 활용한 풍향풍속이 적용된 박격포용 극표정법 프로그램 개발 (The Development of Mortar POLAR Program with Windward Wind Speed use Drones)

  • 황휘;김정환
    • 대한임베디드공학회논문지
    • /
    • 제18권4호
    • /
    • pp.185-194
    • /
    • 2023
  • Currently, drones are used in various fields such as transportation, agriculture and military. Especially, drones for military use are developed and utilized in many ways such as reconnaissance and bombing to minimize one's own damages. Nevertheless, they are developed as new weapons of modern types, so it is difficult to use them together with existing weapons. In this study, a drone program for effective bombing of mortar, which is often used in modern warfare, is developed. In mortar, a forward soldier comprehends the location of enemy for its distance and altitude, input them in data computer of launching angle, and applies the result value to cannon to launch. However, the existing method has low accuracy of bombing because observing shall be done within 1km from the target, and measuring accurate direction and velocity of the wind is difficult. Whereas, in the program of this study, the location of target, GPS, direction and velocity of the wind, and altitude are measured through drone. Each digit is used to calculate bombing specification for optimal bombing through the calculating formula of launching angle. In addition, when specifications are input in the program, the calculation is done automatically, so that it can be used in various mortars and shells. With the use of the program in this study, the location of enemy can be comprehended, and bombing specifications can be calculated quickly. It also enables the intensity of the wind to be applied for accurate bombing.

방수공사 현장시공실태에 따른 공사비산정기준 개정요인에 관한 연구 (An Analysis on the Revision Factors of Construction Cost Calculation Criteria through Field Survey of Waterproof Work)

  • 오재훈;안방률
    • 한국산학기술학회논문지
    • /
    • 제20권10호
    • /
    • pp.468-477
    • /
    • 2019
  • 다양한 재료와 신기술의 개발로 방수공사 시공방법이 변화되고 현장에 적용되고 있으나, 공사비산정기준은 현장실태를 제대로 반영하지 못하고 있다. 본 연구에서는 공사비산정기준을 개정하기 위해 시방기준분석과 현장실태 조사를 통한 주요개정내용 및 결과를 분석하였다. 먼저 현재 공사비산정기준에서 정하는 각 항목들을 분석하여 현장조사를 통한 실태와 비교 분석하였다. 주요 조사 내용으로는 현장의 바탕면 품질수준 향상으로 바탕처리 난이도가 감소하였으며, 재료의 기능향상으로 시공시간 단축과 다양한 시공방 법이 적용되고 있었다. 또한, 두 가지 이상의 재료를 복합적으로 사용하는 복합방수공법의 적용이 늘어나고 있었으며, 시공장소, 부위에 따라 생산성의 차이가 나타나는 것으로 분석되었다. 이 결과를 바탕으로 방수항목을 세분화하여 복합공법에 적용이 가능하도록 하였으며, 재료별, 시공방법별 투입 품을 차별화 하였다. 시공부위에 따라 구분된 기준을 제시하며, 적용성이 떨어지는 항목은 삭제하여 시방기준에 적합하고 현장시공실태를 반영한 개정으로 공사비산정기준의 적정성이 확보되었다. 향후 시방기준과 현장의실태의 변화에 유연하게 대응할 수 있는 세부화된 공사비산정기준 마련이 필요하다.

Transverse reinforcement for confinement at plastic hinge of circular composite hollow RC columns

  • Won, Deok Hee;Han, Taek Hee;Kim, Seungjun;Park, Woo-Sun;Kang, Young Jong
    • Computers and Concrete
    • /
    • 제17권3호
    • /
    • pp.387-406
    • /
    • 2016
  • Confined transverse reinforcement was arranged in a plastic hinge region to resist the lateral load that increased the lateral confinement effect in the bridge substructure. Columns increased the seismic performance through securing stiffness and ductility. The calculation method of transverse reinforcements at plastic hinges is reported in the AASHTO-LRFD specification. This specification was only proposed for solid reinforced concrete (RC) columns. Therefore, if this specification is applied for another column as composite column besides the solid RC column, the column cannot be properly evaluated. The application of this specification is particularly limited for composite hollow RC columns. The composite hollow RC column consists of transverse, longitudinal reinforcements, cover concrete, core concrete, and an inner tube inserted in the hollow face. It increases the ductility, strength, and stiffness in composite hollow RC columns. This paper proposes a modified equation for economics and rational design through investigation of displacement ductility when applying the existing specifications at the composite hollow RC column. Moreover, a parametric study was performed to evaluate the detailed behavior. Using these results, a calculation method of economic transverse reinforcements is proposed.

22.9kV CN/CV 전력 케이블의 상시 허용전류에 관한 연구 (A study on the continuous permissible current rating in 22.9kV CN/CV underground distribution power cables)

  • 김정배;김정태;구자윤;선종호;류희석;조연옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.304-307
    • /
    • 1990
  • Referring to the calculation of the continuous permissible current rating in 22.9kV CN/CV underground distribution power cables, the current and temperature have been fully discussed and analyzed based on their three different values: one is the actually measured value throughout our test and the other two are calculated in connection with different specifications IEC-287 and JCS-168-D respectively. For this purpose, our test has been carried out with real cables which have been under stress either with induced current or with rating voltage. In the former, the calculated current of IEC-287 shows closer value to the measured one than that of JCS-168-D does. In the latter, there has been little difference on the temperature comparing with that measured without voltage application. Therefore, we think that it is preferable to choose the IEC-287 specification for the calculation of the continuous permissible current rating in the commercially power cables.

  • PDF

과학기술위성 3호 다목적 적외선 영상시스템 적외선 우주배경복사 관측 감도 계산 (SENSITIVITY CALCULATIONS FOR THE COSMIC IR BACKGROUND OBSERVATIONS BY MIRIS)

  • 이대희;이성호;한원용;박장현;남욱원;진호;육인수;박영식;박성준;이형목;박수종
    • 천문학논총
    • /
    • 제22권4호
    • /
    • pp.177-181
    • /
    • 2007
  • We present the sensitivity calculation results for observing the Cosmic Infrared Background (CIRB) by the Multi-purpose IR Imaging System (MIRIS), which will be launched in 2010 as a main payload of the Science and Technology Satellite 3 (STSAT-3). MIRIS will observe in I ($0.9{\sim}1.2um$) and H ($1.2{\sim}2.0um$) band with a $4{\times}4$ degree field of view to obtain the large scale structure (${\sim}3$ degree) of the CIRB. With the given specifications of the MIRIS, our sensitivity calculation results show that the MIRIS has a detection limit of ${\sim}9\;nW\;m^{-2}\;sr^{-1}$ (I band) and ${\sim}6\;nW\;m^{-2}\;sr^{-1}$ (H band), which is appropriate to observe the large scale structure of CIRB.

도시부 횡단보도 제원 산정에 관한 연구 - 폭과 정지선을 중심으로 - (Estimating the Dimension of a Crosswalk in Urban Area - Focusing on Width and Stop Line -)

  • 김윤미;박제진;권성대;하태준
    • 대한토목학회논문집
    • /
    • 제36권5호
    • /
    • pp.847-856
    • /
    • 2016
  • 최근 우리나라는 고도의 경제 성장과 더불어 급격한 도시화로 인하여 인구, 환경, 주택문제가 발생하고 있고, 특히 교통문제는 심각한 사회 문제로 대두되고 있는 실정이다. 현재까지의 교통정책 방향은 차량소통 중심으로 시행되어 온 것이 현실이다. 이에 본 연구에서는 운전자 관점이 아닌 보행자 관점의 교통정책의 필요성을 부각시키고자 한다. 2015년 전체 교통사고 사망자수(4,621명) 대비 보행 중 사망자수(1,795명) 비율은 38.8%로 보행자 교통사고 해결 방안 수립이 요구되고 있다. 횡단보도는 보행자가 안전하게 횡단할 수 있어야 하지만 현행 횡단보도의 폭원 산정 및 정지선 설치위치에 대한 명확한 기준 없이 도로의 폭을 기준으로 설치되어 있다. 특히 보행량이 많은 대학교나 상업시설 주변 지역은 횡단보도 설계 시 보행자 통행을 고려하지 않고 설계되고 있는 실정이다. 횡단보도 녹색시간 동안 수용할 수 있는 보행자 통행량보다 실제 통행량이 많을 경우, 대기 보행자가 주어진 녹색시간 동안 횡단하지 못하거나 주어진 횡단보도 면적을 벗어난 상태로 무리하게 횡단하여 교통 안전상의 문제가 발생할 수 있다. 이에 본 연구에서는 차량소통 위주의 신호시간 결정, 보행 신호시간 부족, 대로 상에서의 보행자 횡단거리 등 많은 문제점을 내재하고 있는 횡단보도 내 보행자 사고율을 낮추고자 보행자 통행량과 보행속도를 고려한 횡단보도 제원을 산정하고자 한다. 먼저 횡단보도 제원 산정을 위해 횡단보도, 보행자, 정지선에 관한 법규와 기존 연구문헌을 고찰하였다. 기존 횡단보도 제원과 정지선의 문제점을 분석하여 횡단보도 제원 산정을 위한 방법론을 제시하고, 이를 토대로 횡단보도 제원을 산정하였다. 결론적으로 본 연구에서 제시한 횡단보도 제원 및 정지선 개선방안은 해당 교통안전시설물 설치 및 기준 정립 시 기초 자료로 활용 가능할 것으로 기대된다.

고속도로 졸음쉼터 제원 산정 및 설계기준 정립에 관한 연구 (Development of Specifications and Design Criteria of Rest Area for Drowsy Drivers)

  • 오석진;박제진;홍정표;하태준
    • 대한토목학회논문집
    • /
    • 제37권2호
    • /
    • pp.397-407
    • /
    • 2017
  • 본 연구는 고속도로 졸음쉼터 현황 조사 및 문제점 도출을 통해 졸음쉼터의 제원 산정 및 설계기준 수립을 위한 개선안 제시를 목적으로 한다. 고속도로 졸음쉼터 진입부를 감속변이구간, 감속차로, 진입연결로로 분류하고, 진출부는 진출연결로, 가속차로, 가속변이구간으로 분류하여 차량의 본선 주행속도, 진출입연결로의 시 종점부 주행속도, 감속도 및 가속도 등을 고려하여 구간별 적정길이를 산정하였다. 또한 졸음쉼터 주차부를 주차형태, 횡단구성 주차공간의 길이 등으로 구분하고, 실제 졸음쉼터를 이용하는 차량의 이용률, 중차량 비율, 졸음쉼터 내 설계속도 등을 고려하여 합리적인 설계기준을 정립하였다. 본 연구를 통해 제시된 고속도로 졸음쉼터 설계기준은 향후 졸음쉼터 계획 및 재정비 시 유용하게 활용될 수 있을 것으로 판단된다. 또한, 고속도로 졸음쉼터의 규정 및 산정 결과를 고려한 졸음쉼터의 설치기준 정립은 휴게시설 및 고속도로 교통사고 예방은 물론 이용률 증가 및 안전성 측면의 향상을 가져올 것으로 판단된다.

벌크화물용 포장용기의 최적 설계(II)-프로그램 개발 (Optimum Design of Packaging Container for Bulk Materials(II)-Computer Program Development)

  • 박종민;권순홍;정성원
    • 한국포장학회지
    • /
    • 제6권1호
    • /
    • pp.12-18
    • /
    • 2000
  • If optimum design technique is applied in the design of packaging container for bulk materials, merits on the side of not only economic and compression performance but distribution efficiency are expected. In this study, on the ground of the optimum models for required board area and compression strength performance, optimum design program having faculties of outward and inward optimum design and information design was developed. This program was composed of input module, output module, database and management module, and calculation module. Though the packaging specifications ars same, requied board area, board composition and cost of container were greatly different according to exterior packaging conditions. Also, about 12% in weight of container was lighter, and about $13{\sim}17%$ in cost of container was reduced when the program was applied for 2 kinds of bulk materials.

  • PDF