• Title/Summary/Keyword: Calculate

검색결과 11,142건 처리시간 0.034초

Modified TOUGHREACT를 이용한 지중 열교환기 내 순환 유체의 온도 분포 추정 (A Study to Calculate Inlet Fluid Temperature of the Borehole Heat Exchanger (BHE) using Modified TOUGHREACT)

  • 김성균;배광옥;이강근;심병완;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.477-480
    • /
    • 2007
  • Inlet fluid temperature of the BRE in the geothermal heat pump system depends on heat exchange rate between the refrigerant of the heat pump and the leaving fluid from the BRE. Because the outlet fluid temperature of the BHE varies with time, inlet fluid temperature has to vary with time. In this study, the module to calculate inlet fluid temperature is developed, which can consider the time-varying outlet fluid temperature and the heat exchange capacity of the heat pump. It is assumed that heat loss or gain of the leaving fluid from outlet to inlet of the BHE is negligible, except when the fluid contacts with the refrigerant of the heat pump. This module is combined with TOUGHREACT, a widely accepted three-dimensional numerical simulator for heat and water flow and geochemical reactions in geothermal systems and is applied to data analyses of the thermal response test.

  • PDF

그래픽 프로그래밍 기법을 이용한 주축용 유도전동기의 속도 센서리스 토크감시 (Speed Sensorless Torque Monitoring of Induction Spindle Motor using Graphical Programming)

  • 박진우;권원태
    • 한국정밀공학회지
    • /
    • 제19권10호
    • /
    • pp.107-113
    • /
    • 2002
  • To monitor the torque of an induction motor using current, rotating speed has been measured and used to calculate the slip angular velocity. Additional sensor, however, can cause extra expense and trouble. In this paper, a new algorithm is proposed to monitor the torque of vector controlled induction motor without any speed measuring sensor. Only stator current is measured to estimate the magnetizing current which is used to calculate flux linkage, rotor velocity and motor torque. Graphical programming is used to implement the suggested algorithm and to monitor the torque of an induction motor in real time. To solve the fluctuation problem of estimated torque caused from instantly varying rotating speed of an induction motor, the rotating speed is reconstructed based on the measured current signals. From several experiments, the proposed method shows a good estimation of the motor torque under the normal rotational speed.

동남해안지역의 피압단열 대수층에서 조석 분석법을 이용한 수리상수 추정

  • 심병완;정상용;성익환;이병대;조병욱
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.497-500
    • /
    • 2003
  • If ground water levels of a confined fractured rock aquifer fluctuate with sea tides, individual values of hydrogeologic parameters can be determined. Tidal efficiency and time lag are first calculated from the water level data recorded at an observation device situated inland from the sea. The tidal efficiency factor of the aquifer at the seacoast is then determined from the observation in monitoring wells and used to calculate storage coefficient. Tidal efficiency factor and the tidal time lag are utilized to calculate storage coefficient and the results are compared. This method is tested in the southeastern coastal area of Busan, Korea. This is a simple and inexpensive way to test confined aquifer but the analysis should be performed according to the coastal environment.

  • PDF

Free Spanning of Offshore Pipelines by DNV

  • CHOI HAN SUK
    • 한국해양공학회지
    • /
    • 제19권2호
    • /
    • pp.47-52
    • /
    • 2005
  • This paper introduces a procedure for free span and fatigue analysis of offshore pipelines per DNV-RP-F105, 2002. The new method includes the axial force and deflection load in pipelines. The screening criteria were established to calculate the allowable span lengths in the new design codes. The screening criteria allows a certain amount of vortex-induced vibration due to wave and current loading. However, the induced pipe stresses are very small and usually below the limit stresess of typical S-N curves. In contrast, the conventional criteria did not allow any vortex-induced vibration in the free span of pipelines. Thus, the screening criteria yields reduced allowable span lengths. A simplified procedure was established to calculate the fatigue damage due to long-term current distribution. The long-term current statistics was assumed with a 3-parameter Weibull distribution. The fatigue damage was estimated for the span lengths obtained from the screening criteria for various conditions. Sample calculations show the effect of axial force for various boundary conditions. Comparisons with conventional criteria are included.

GIS내에 함유된 자유 도전성 파티클의 거동해석 (A Numerica analysis on the lift-off motion of Free Conducting Particle in GIS)

  • 이방욱;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1925-1928
    • /
    • 1996
  • In this work, the behavior of conducting wire type particles existing inside the cylinder type coaxial electrode has been systematically investigated by charge simulation method and electrostatic force analysis from the view point of the acquired charging before being lifted off into the gap under the high ac voltage. Spheroidal charge are adopted as a image charge for the CSM analysis in order to calculate the acquired charges of the particles which are erected on the surface of the outer electrode. For this purpose, different material of the particle and their lengths and diameters have been considered in view to calculate their lift-off field, acquired charge and to understand their effect on the lift-off voltage. The results imply that the particle lengths and diameter have an different influence on the particle behavior in GIS system.

  • PDF

브러시 없는 직류 선형 모터의 추력 계산 방법의 비교 (The Comparison of thrust computational methods of a brushless DC linear motor)

  • 최문석;김용일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.32-34
    • /
    • 1997
  • For a given brushless DC linear motor, we suggest the numerical prediction methods to analyze it's thrust characteristics. First, we calculate the magnetic flux density by the finite element method, and we then compute the maximum thrust with three computational methods - a Lorentz equation, a Maxwell stress method and a virtual work method. To confirm the accuracy of the computational methods, we measure the thrust of the linear motor made by our laboratory with a force-torque sensor. Also, we calculate the thrust by the measured back electromotive force. To choose the appropriate method for a specified application, we compare the maximum thrusts of the computational method and the calculation by the back electromotive force with the measured one. We conclude that the Maxwell stress method is turned out the best because it has the most accurate results among three computational methods and it is more convenient than the calculation method by the back electromotive force.

  • PDF

IEC 60909에 의한 삼상 고장계산 (Three-phase Fault Calculation by IEC 60909)

  • 손석금
    • 전기학회논문지P
    • /
    • 제63권1호
    • /
    • pp.12-18
    • /
    • 2014
  • This paper analyzes how to calculate the three phase short circuit current calculation procedures used in the IEC 60909 short circuit. It presented the new procedure of the fault current for the interrupting capacity of the circuit breaker. This procedure is applied to the future power system and calculates the fault current. Power demands are increased because of the growth of the economy for this reason, the fault current of the power system is largely increased and the fault current procedure for the proper interrupting capacity calculation of the existing or the new circuit breaker is essential. How to calculate the three phase short circuit current for ac electrical system and select the high voltage and low voltage circuit breaker based on IEC 60909 standards.

A Fast Algorithm of the Apparent Factor Calculation for Distance Relay Setting without Fault Analysis

  • Jo, Yong-Hwan;Xiang, Ling;Choi, Myeon-Song;Park, Ji-Seung;Lim, Seong-Il;Kim, Sang-Tae;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.64-69
    • /
    • 2013
  • For power system protection, the distance relay settings are important. Apparent factor is a necessary parameter in distance relay settings. Apparent factors have to be calculated when setting the distance relays and doing the resetting in case of configuration change in power system. The problem is that the current method to calculate apparent factor requires tools and plenty of time to do fault analysis and this method is complex especially in case of configuration change. Therefore this paper proposes a fast algorithm to calculate apparent factor without the fault analysis. Test results prove that this algorithm is simple and accurate by simulation.

임피던스 행렬 구성법을 이용한 순간전압강하 취약지역의 계산 (Calculation of the Area of Vulnerability to Voltage Sags by using Impedance Building Algorithm)

  • 박종일;박창현
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.44-53
    • /
    • 2012
  • This paper presents a method to calculate the area of vulnerability by using the impedance building algorithm. The installation of DG (Distributed Generation) is one of the countermeasures against voltage sags in power systems. In order to estimate the effect of the DG, the voltage sag assessment should be performed based on the area of vulnerability and system fault statistics. To determine the area of vulnerability, system impedance matrix should be calculated. The calculation of the impedance matrix of large systems is time-consuming task. This paper addresses an effective scheme to calculate the area of vulnerability and system impedance matrix.

Hydro-mechanical analysis of non-uniform shrinkage development and its effects on steel-concrete composite slabs

  • Al-Deen, Safat
    • Steel and Composite Structures
    • /
    • 제26권3호
    • /
    • pp.303-314
    • /
    • 2018
  • Drying shrinkage in concrete caused by drying and the associated decrease in moisture content is one of the most important factors influencing the long-term deflection of steel-concrete composite slabs. The presence of profiled steel decking at the bottom of the composite slab causes non-uniform drying from top and bottom of the slab resulting non-uniform drying shrinkage. In this paper, a hydro-mechanical analysis method is proposed to simulate the development of non-uniform shrinkage through the depth of the composite slab. It also demonstrates how this proposed analysis method can be used in conjunction with previously presented structural analysis model to calculate the effects of non-uniform shrinkage on the long-term deflection of the slab. The method uses concrete moisture diffusion model to simulate the non-uniform drying of composite slab. Then mechanical models are used to calculate resulting shrinkage strain from non-uniform drying and its effect on the long-term behaviour of the composite slabs. The performance of the proposed analysis method is validated against experimental data.