• 제목/요약/키워드: Caisson Structure

검색결과 91건 처리시간 0.02초

해상 Crane용 Guide Frame의 안정성에 관한 연구 (A Study on Stability Hanging Guide Frame used in Floating Crane)

  • 장동일;민인기
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.33-40
    • /
    • 1999
  • In this paper, a damaged example of hanging guide frame used in the lifting of shore protection caisson was investigated. An examination of the stress and stability of members was carried out by structural analysis and the causes of damages was investigated. The stability analysis considering local and global stress buckling was performed. As a result of stability analysis. the first structure was unstable structure. Therefore improved structure was examined and the best effective methodology was the reassignment of wire.

  • PDF

Development and Application of Dry Process Caisson for Maintenance of Submerged Barber Structure

  • Lee, Joong-Woo;Lee, Seung-Chul;Oh, Dong-Hoon;Kwak, Seung-Kyu;Lee, Jeong-Su
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 Asia Navigation Conference
    • /
    • pp.105-114
    • /
    • 2006
  • Together with the trend of enhancement in domestic industrial development and economic progress due to import and export, the demand for construction of the roads, bridges, especially port facilities, and several coastal protection and ocean structures is increasing rapidly. MOMAF of Korean Government is driving construction of 9 new ports and renovation of the existing fishery ports. Among these structures most of bridge base, wharves, dolphins, quays, and jetties are being newly built of steel or concrete pile. As the base, supporting bulkheads, and piles are underwater after construction, it is difficult to figure out the status of structures and not enough to get maintenance and strengthen the structures. Every year, moreover, these works suck the government budget due to higher incomplete maintenance expense for protection from corrosions of structures and increased underwater construction period. for the purpose of cutting down the government budget, it is necessary to extend the life cycle of the existing structures. We developed a new method for maintenance of submerged structures near the waterline by allowing dry work environment with the floating caisson. The method shows easy to move around the working area and handle. It also showed not only a significant reduction of maintenance expenses and time for anti-corrosion work but also better protection. This will be a milestone to reduce the maintenance and construction expenses for the shore and water structures.

  • PDF

국내 지진규모를 고려한 케이슨 안벽의 지진시 수평변위 특성에 관한 연구 (A Study on the Seismically-induced Lateral Displacements of Caisson Quay Walls Considering Seismic Magnitude in Korea)

  • 박근보;차승훈;최재순;김수일
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.83-90
    • /
    • 2002
  • There are few earthquake records in Korea and the Japanese or American representative earthquake records have been generally used in the seismic design. In this study, some earthquake records which the range of earthquake magnitudes varies from 5.3 to 7.9 were collected and analyzed to assess which record can rationally reflect Korean seismic characteristics. In this assessment, each seismic energy and acceleration spectrum were analyzed with the unified maximum ground acceleration. Several numerical analyses on Korean representative caisson structures were also carried out to compare each dynamic displacement. In these numerical analyses, soil conditions and the dimension of structure such as height and width were changed. Through this assessment, it is found that the compatible earthquake magnitude in Korea is lower than 7. From the result of numerical analyses, it is shown that horizontal dynamic displacements corresponding to earthquake magnitudes over than 7 are quite larger than those below earthquake magnitude 7. Based on this study, it is necessary that Korean seismic design guideline will refer earthquake magnitude criteria for the construction of the economical aseismic structure.

  • PDF

항만용 Precast Concrete 구조물의 마찰계수 측정 실험 (Measurement Tests of Friction Coefficient of Precast Concrete Used in Haber Construction)

  • 김명식;백동일;김강민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.73-76
    • /
    • 2006
  • The shape and dimension of precast concrete structure used in habor construction(caisson, block, etc.) are considered productive facility abilities, demanded minimum dimension in work of each member, the relation between the depth of water and a location of leaving, work conditions of towing and leaving, after leaving, differential settlement, etc. As this study examined friction resistance effect of financially designed precast concrete structure formed convex in bottom and stone mound.

  • PDF

동해항 방파제를 대상으로 한 신뢰성 설계법의 비교 연구. 2. 케이슨의 활동 (Comparative Study of Reliability Design Methods by Application to Donghae Harbor Breakwaters. 2. Sliding of Caissons)

  • 김승우;서경덕;오영민
    • 한국해안해양공학회지
    • /
    • 제18권2호
    • /
    • pp.137-146
    • /
    • 2006
  • 본 논문은 동해항 방파제를 대상으로 신뢰성 설계법을 비교하는 한 쌍의 논문의 두 번째 부분이다. 제 2부인 본 논문에서는 케이슨의 활동을 다룬다. 사석 마운드 위에 케이슨을 거치한 직립방파제의 파괴모드는 케이슨의 활동 및 전도, 그리고 사석 마운드 또는 지반의 파괴 등이 있는데, 그 중 케이슨의 활동에 의한 파괴가 가장 많이 발생한다. 케이슨 활동 파괴에 대한 기존의 결정론적 설계법은 저항이 하중보다 일정 배수(예를 들어 1.2배) 커야 한다는 안전율 개념으로 접근한다. 그러나 안전율의 개념으로는 구조물의 안정성을 정량적으로 평가할 수 없다. 한편 최근 활발한 연구가 진행되고 있는 신뢰성 설계법은 구조물의 파괴확률을 산정함으로써 안정성에 대한 정량적인 평가를 가능케 한다. 신뢰성 설계법은 사용되는 확률적 개념의 정도에 따라 Level 1, 2 및 3의 세가지로 분류된다. 본 연구에서는 기존의 결정론적 방법으로 설계, 시공된 후 1987년 피해를 입었던 동해항 방파제의 케이슨 활동에 대하여 피해 전과 보강 후의 단면에 대해서 각각 신뢰성 해석을 수행하였다. 그 결과 피해 전 단면의 파괴확률은 허용파괴확률을 크게 초과하여 케이슨이 과소 설계되었음을 나타내는 반면, 보강 후 단면의 파괴확률은 허용파괴확률과 비슷한 값을 보임으로써 보강 후 안정한 구조물이 되었음을 나타냈다. 한편, 서로 다른 세 가지 신뢰성 설계법의 결과가 대체로 잘 일치하는 것을 보임으로써 각 방법을 이용한 해석 결과 사이에는 큰 차이가 없음을 확인하였다.

교량 우물통 기초의 세굴피해 평가를 위한 고유진동수 측정 (Natural Frequency Measurement for Scour Damage Assessment of Caisson Pier)

  • ;고석준;정경자;이주형;유민택;김성렬
    • 한국지반공학회논문집
    • /
    • 제37권11호
    • /
    • pp.51-60
    • /
    • 2021
  • 하천의 세굴은 교각 주변의 흙을 침식시켜 교각의 횡방향 지지력을 저감시키고 구조물의 건전도를 저하시키게 된다. 본 연구에서는 세굴이 구조물의 건전도에 미치는 영향을 살펴보고자 주변지반의 굴착에 따른 교각의 고유진동수 측정실험을 수행하였다. 폐교예정인 만경강교의 우물통기초 교각에서 충격진동시험을 수행하였다. 교각의 상단, 중앙, 하단에 가속도계를 부착하고 세 지점을 타격하여 가속도를 계측하였다. 실험 결과, 타격위치에 따른 가속도 측정값 중 상단타격이 일관되고 합리적인 가속도 결과를 보여주었다. 계측된 가속도는 고속 푸리에 변환(FFT)을 통하여 주파수 영역으로 변환되었고, 이를 이용하여 고유진동수를 측정하였다. 또한, 세굴이 교각의 고유진동수 변화에 미치는 영향을 분석하기 위하여 교각 주변 지반을 굴착하면서 고유진동수의 변화를 측정하였다. 그 결과, 굴착 깊이에 따라 고유 진동수가 감소하는 경향을 보여주었지만, 우물통 기초형식이 큰 강성을 가지고 있어 그 감소폭은 작은 것으로 나타났다.