• Title/Summary/Keyword: Caisson Structure

Search Result 91, Processing Time 0.023 seconds

Seismic behavior of caisson-type gravity quay wall renovated by rubble mound grouting and deepening

  • Kim, Young-Sang;Nguyen, Anh-Dan;Kang, Gyeong-O
    • Geomechanics and Engineering
    • /
    • v.27 no.5
    • /
    • pp.447-463
    • /
    • 2021
  • Caisson-type structures are widely used as quay walls in coastal areas. In Korea, for a long time, many caisson-type quay walls have been constructed with a low front water depth. These facilities can no longer meet the requirements of current development. This study developed a new technology for deepening existing caisson-type quay walls using grouting and rubble mound excavation to economically reuse them. With this technology, quay walls could be renovated by injecting grout into the rubble mound beneath the front toe of the caisson to secure its structure. Subsequently, a portion of the rubble mound was excavated to increase the front water depth. This paper reports the results of an investigation of the seismic behavior of a renovated quay wall in comparison to that of an existing quay wall using centrifuge tests and numerical simulations. Two centrifuge model tests at a scale of 1/120 were conducted on the quay walls before and after renovation. During the experiments, the displacements, accelerations, and earth pressures were measured under five consecutive earthquake input motions with increasing magnitudes. In addition, systematic numerical analyses of the centrifuge model tests were also conducted with the PLAXIS 2D finite element (FE) program using a nonlinear elastoplastic constitutive model. The displacements of the caisson, response accelerations, deformed shape of the quay wall, and earth pressures were investigated in detail based on a comparison of the numerical and experimental results. The results demonstrated that the motion of the caisson changed after renovation, and its displacement decreased significantly. The comparison between the FE models and centrifuge test results showed good agreement. This indicated that renovation was technically feasible, and it could be considered to study further by testbed before applying in practice.

A Study on the Grouting for the Underpinning of Open Caisson of Existing Bridge (기존 교량구조물의 유지관리를 위한 우물통 기초 보강주입에 관한 연구)

  • Chun, Byung-Sik;Yeoh, Yoo-Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.1
    • /
    • pp.131-138
    • /
    • 2000
  • In this study, physical and engineering properties of ordinary portland cement and microcement were investigated to verify reinforcing effect of underpinning of open caisson foundation by using microcement grouting. Laboratory injection tests such as infiltration and injection in case of seepage for the stream bed soil at ${\bigcirc}{\bigcirc}$ Great Bridge in Seoul were carried out. Field injection tests to reinforce open caisson foundation at ${\bigcirc}{\bigcirc}$ Great Bridge were performed and the ability of application by microcement grouting was evaluated. From the test results, physical and engineering properties of microcement are better than those of ordinary portland cement. Also, the ability of infiltration and solidity in case of seepage is better than that of ordinary portland cement. Therefore, it is concluded that microcement is an excellent material to reinforce open caisson foundation of the existing bridge structure under the water and can be used as underpinning material of general foundations.

  • PDF

Dispersion Effects of Wave Force on Interlocking Caisson Breakwater with Shear-Key (전단키형 인터로킹 케이슨 방파제의 파력분산효과)

  • Song, Sung Hoon;Park, Min Su;Jeong, Youn Ju;Hwang, Yoon Koog
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.195-201
    • /
    • 2019
  • Long caisson breakwaters can improve the structural safety of a caisson due to the wave dispersion effect which reduces the average wave force acting on one caisson. However, in order to make long caissons, there are many manufacturing and construction limitations. Recently, interlocking caisson systems, which are to form a long caisson by interlocking individual caissons with adjacent caissons, have been much attention. In the present study, a interlocking caisson system with shear-keys was proposed and the wave dispersion effect according to the shear-key was evaluated analytically. As a result, (1) Because of the asymmetric shape of the interlocking caisson, the structure behavior and the wave dispersion effect of one are also asymmetric. (2) The wave dispersion effect is more influenced by the distribution and characteristics of wave acting on each caisson rather than the shape of the shear-key such as shear angle, height, shear length ratio. (3) The interlocking caisson breakwater is almost the same behavior and wave dispersion effect as a fully integrated breakwater.

Settlement Evaluation of Caisson-Type Quay Wall Using PSI of Velocity During Earthquake (지진시 속도의 PSI를 활용한 케이슨식 안벽의 침하량 평가 )

  • Gichun Kang;Hyunjun Euo;Minje Baek;Hyunsu Yun;Jungwook Choi;Seong-Kyu Yun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.2
    • /
    • pp.71-83
    • /
    • 2023
  • It is very important to predict the amount of settlement in order to maintain the function of the coastal structure. Finite element analysis methods and real and model experiments are used as methods for this, but this has the disadvantage of requiring a lot of cost and time. Therefore, this study was conducted for the purpose of a simple formula proposal that can easily predict the amount of settlement of the caisson-type quay wall structure. In the research process, after calculating the PSI (Power Spectrum Intensity) of the velocity, the amount of settlement of the structure is calculated by substituting it into the simple formula of the existing gravity breakwater. By comparing and analyzing the amount of settlement of the structure obtained through numerical analysis, it was confirmed that the error between the amount of settlement of the existing simple formula and the amount of settlement of the numerical analysis was large, and it was confirmed that the background could not be considered in the case of the existing simple formula. Therefore, this study proposed a correction factor for the background of the quay wall structure, indicating a simple formula that can obtain the amount of settlement of the caisson-type quay wall structure. Compared to the numerical analysis settlement amount, it was judged that this simple formula had sufficient precision in calculating the caisson-type quay wall settlement amount. In addition, facilities vulnerable to earthquake resistance can be easily extracted in situations where time and cost are insufficient, and it is expected to be used as a screening technique.

Evaluation of Vibration Characteristics of Caisson-Type Breakwater Using Impact Vibration Tests and Validation of Numerical Analysis Model (진동시험에 의한 방파제 케이슨의 동특성 평가 및 수치해석 모델의 검증)

  • Yi, Jin-Hak;Park, Woo-Sun;Lee, So-Young;Kim, Jeong-Tae;Seo, Choon-Gyo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • In this study, impact vibration tests are applied to analyze the vibration characteristics of caisson-type breakwater, and the results obtained from vibration tests are compared with numerical simulation results considering fluid-soil-structure interaction effects to verify the feasibility of a numerical analysis model. It is found that natural frequencies are reduced as amount of 1.7-4.3% after additional parapet structure is added to increase the height of breakwater, and the same results was observed from the numerical simulation study. Through the comparison, it was verified that the vibration tests and numerical simulation study can be applied to evaluate the vibration characteristics of caisson-type breakwater.

Characteristics of Wave by Additional Installation of Porous Dual Circular Caissons on the Existing Breakwater (기존 방파제에 투과성 이중 원형케이슨 추가설치에 따른 파랑 특성 분석)

  • Park, Min Su
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.6
    • /
    • pp.396-410
    • /
    • 2020
  • The design and the construction are carried out by installation of new caissons on the back or the front of existing caissons to increase the stability of existing caisson breakwater. In this study, we use the eigenfunction expansion method to analyze the effects of wave structure interaction when new porous dual circular caissons are installed on the back or the front of existing breakwater. The porous dual circular caisson which consisting of a porous outer cylinder circumscribing an impermeable inner cylinder is one type of seawater exchanging breakwater. The comparison of numerical results between present method and Sankarbabu et al. is made, and the wave force and the wave run-up acting on each porous dual circular caisson are calculated for various parameters by considering the wave structure interaction.

Development of Time-Dependent Reliability-Based Design Method Based on Stochastic Process on Caisson Sliding of Vertical Breakwater (직립방파제의 케이슨 활동에 대한 확률과정에 기반한 시간의존 신뢰성 설계법 개발)

  • Kim, Seung-Woo;Cheon, Sehyeon;Suh, Kyung-Duck
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.5
    • /
    • pp.305-318
    • /
    • 2012
  • Although the existing performance-based design method for the vertical breakwater evaluates an average sliding distance during an arbitrary time, it does not calculate the probability of the first occurrence of an event exceeding an allowable sliding distance(i.e. the first-passage probability). Designers need information about the probability that the structure is damaged for the first time for not only design but also maintenance and operation of the structure. Therefore, in this study, a time-dependent reliability design method based on a stochastic process is developed to evaluate the first-passage probability of caisson sliding. Caisson sliding can be formulated by the Poisson spike process because both occurrence time and intensity of severe waves causing caisson sliding are random processes. The occurrence rate of severe waves is expressed as a function of the distribution function of sliding distance and mean occurrence rate of severe waves. These values simulated by a performance-based design method are expressed as multivariate regression functions of design variables. As a result, because the distribution function of sliding distance and the mean occurrence rate of severe waves are expressed as functions of significant wave height, caisson width, and water depth, the first-passage probability of caisson sliding can be easily evaluated.

Hydraulic Experiments on Reflection Coefficients for Perforated Wall Caisson with Rock Fill (유수실을 사석으로 채운 유공 케이슨에 대한 반사계수 실험)

  • Kim, Young-Taek;Lee, Jong-In
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.403-408
    • /
    • 2019
  • In general, the caisson having the perforated wall is used to for the purpose of reducing the wave reflection and wave overtopping. In this study, the hydraulic characteristics (reflection coefficient) of the perforated wall caisson chamber filled with aggregates (rocks) were investigated with hydraulic model tests. When the perforated wall chambers were filled with aggregates, the reflection coefficients would increase. However, it was confirmed that the rock filling method into the perforated wall chamber could secure the stability of the structures and satisfy the hydraulic characteristics at a certain level.

Structural Health Monitoring of Harbor Caisson-type Structures using Harmony Search Method (최적화 화음탐색법을 이용한 항만 케이슨 구조물의 구조건전성 평가)

  • Lee, So-Young;Kim, Jeong-Tae;Yi, Jin-Hak;Kang, Yoon-Koo
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.122-128
    • /
    • 2009
  • In this study, damage detection method using harmony search method and frequency response is proposed. In order to verify this method, the following approaches are implemented. Firstly, damage detection method using harmony search was developed. To detect damage, objective functions that minimize difference with natural frequency and modal strain energy from undamaged and damaged model are used. Secondly, efficiency of developed damage detection method was verified by damage detection of beam structure. And results of harmony search and micro genetic algorithm are compared and evaluated. Thirdly, numerical model was implemented for harbor caisson structure and damage scenario was determined. Lastly, damage detection was performed by proposed method and utility of proposed method is verified.

Analysis on Phase Relation between Inertia Force and Dynamic Earth Pressure of Caisson by Numerical Analysis (수치해석을 이용한 우물통 기초의 관성력과 동적토압의 위상관계 분석)

  • Kim, Sung-Ryul;Jang, Hak-Sung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.23-31
    • /
    • 2008
  • Dynamic earth pressure acting on geotechnical structures can be driving force or resisting force for the displacement of the structure according to the phase relation between the dynamic earth pressure and inertia force of structures. In this research, the evaluation procedure of the phase relation between the dynamic earth pressure and the inertia force was proposed. According to the procedure, numerical analyses on caisson foundation of bridges were performed and the phase relation was analyzed. The analysis results showed that the dynamic earth pressure becomes the driving force, which increases the displacement of the structure, if the displacement amplitude of ground is larger than that of structure due to the low stiffness of the ground, and the dynamic earth pressure becomes the resisting force against the displacement of the structure if the displacement amplitude of ground is smaller than that of structure due to the high stiffness of the ground.