• 제목/요약/키워드: Cadaveric study

검색결과 117건 처리시간 0.024초

Anatomical variation of quadratus plantae in relation with flexor digitorum brevis

  • Punnapa Raviteja;Mrudula Chandrupatla;Ramoju Harshitha;Marni Sameer Chowdary
    • Anatomy and Cell Biology
    • /
    • 제56권4호
    • /
    • pp.562-565
    • /
    • 2023
  • The muscles of the sole have been traditionally categorized into four layers, but it is more practical to divide them into peripheral and central groups. The peripheral groups include medial and lateral groups. The central plantar muscles are more numerous and divided into superficial and deep layers. During routine dissection in the Department of Anatomy, All India Institute of Medical Sciences Bibinagar, Hyderabad, variations are been observed in the plantar intrinsic muscle in the left foot & right foot of a 53-year-old male cadaver. This is the first cadaveric report of a combination of discrepancies especially the inter-tendinous connection between quadratus plantae and flexor digitorum brevis. Similar observations in the literature were not found by us. It is important to identify and study these dissimilarities of muscles of the sole for surgeons, anatomists, radiologists and orthopaedics as these muscles and tendons are used in foot reconstructive procedures, and for the treatment of some congenital anomalies.

Uncommon configuration of intercostobrachial nerves, lateral roots, and absent medial cutaneous nerve of arm in a cadaveric study

  • Rosemol Xaviour
    • Anatomy and Cell Biology
    • /
    • 제56권4호
    • /
    • pp.570-574
    • /
    • 2023
  • The intercostobrachial nerve (ICBN) originates from the second intercostal nerve's lateral cutaneous branch, while the median nerve (MN) typically arises from the brachial plexus's lateral and medial roots. The medial cutaneous nerve of the arm, a branch of the medial cord of the brachial plexus, often connects with the ICBN. Variations were observed during the dissection of a 50-year-old male cadaver, including MN having two lateral roots (LR), LR1 and LR2, joining at different levels. Three ICBNs innervated the arm in this case, with the absence of the medial cutaneous nerve of the arm compensated by branches from the medial cutaneous nerve of the forearm. Understanding these anatomical variations is crucial for surgical procedures like brachioplasty, breast augmentation, axillary lymph node dissection, and orthopedic surgery. Surgeons and medical professionals must be aware of these variations to enhance preoperative planning, minimize complications, and improve patient outcomes in these procedures.

Buccal gland within the bucinator muscle

  • Emma R. Lesser;Arada Chaiyamoon;R. Shane Tubbs;Joe Iwanaga
    • Anatomy and Cell Biology
    • /
    • 제57권1호
    • /
    • pp.152-154
    • /
    • 2024
  • There are major and minor salivary glands that aid in the digestive process. Major glands are discrete and exist in predictable locations; minor salivary glands are more widespread and usually found dispersed in the mucosa of the mouth. Glands have their own contractile abilities, which allow them to secrete products without the assistance of vasculature or skeletal, or smooth muscle. This study will describe a cadaveric histological specimen in which an ectopic buccal gland was embedded within bucinator muscle fibers. Potential causes and explanations for this finding will be discussed, as well.

Feasibility of Bilateral Crossing C7 Intralaminar Screws : A Cadaveric Study

  • Baek, Tae-Hyun;Kim, Ilsup;Hong, Jae-Taek;Kim, Daniel H.;Shin, Dongsuk;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권1호
    • /
    • pp.5-10
    • /
    • 2014
  • Objective : When the pedicle screw insertion technique is failed or not applicable, C7 intralaminar screw insertion method has been used as an alternative or salvage fixation method recently. However, profound understanding of anatomy is required for safe application of the bilaterally crossing laminar screw at C7 in clinic. In this cadaveric study, we evaluated the anatomic feasibility of the bilateral crossing intralaminar screw insertion and especially focused on determination of proper screw entry point. Methods : The C7 vertebrae from 18 adult specimens were studied. Morphometric measurements of the mid-laminar height, the minimum laminar thickness, the maximal screw length, and spino-laminar angle were performed and cross-sectioned vertically at the screw entry point (spino-laminar junction). The sectioned surface was equally divided into 3 parts and maximal thickness and surface area of the parts were measured. All measurements were obtained bilaterally. Results : The mean mid-laminar height was 13.7 mm, mean minimal laminar thickness was 6.6 mm, mean maximal screw length was 24.6 mm, and mean spinolaminar angle was $50.8{\pm}4.7^{\circ}$. Based on the measured laminar thickness, the feasibility of 3.5 mm diameter intralaminar screw application was 83.3% (30 sides laminae out of total 36) when assuming a tolerance of 1 mm on each side. Cross-sectional measurement results showed that the mean maximal thickness of upper, middle, and lower thirds was 5.0 mm, 7.5 mm, and 7.3 mm, respectively, and mean surface area for each part was $21.2mm^2$, $46.8mm^2$, and $34.7mm^2$, respectively. Fourteen (38.9%) sides of laminae would be feasible for 3.5 mm intralaminar screw insertion when upper thirds of C7 spino-laminar junction is the screw entry point. In case of middle and lower thirds of C7 spino-laminar junction, 32 (88.9%) and 28 (77.8%) sides of laminae were feasible for 3.5 mm screw insertion, respectively. Conclusion : The vertical cross-sectioned area of middle thirds at C7 spinolaminar junction was the largest area and 3.5 mm screw can be accommodated with 77.8 % of feasibility when lower thirds were the screw entry point. Thus, selection of middle and lower thirds for each side of screw entry point in spino-laminar junction would be the safest way to place bilateral crossing laminar screw within the entire lamina. This anatomic study result will help surgeons to place the screw safely and accurately.

한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구 (Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study)

  • 윤용철;오종건;김영우;김학준;문홍주;김남렬
    • Journal of Trauma and Injury
    • /
    • 제26권3호
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

돼지진피조직(Porcine Dermal Matrix, $Permacol^{(R)}$)을 이용한 보형물 유방재건술: 무세포성 사체 진피 (Acellular Cadaveric Dermis, $AlloDerm^{(R)}$)와 비교 연구 (Implant Breast Reconstruction Using Porcine Dermal Matrix ($Permacol^{(R)}$): A Comparative Study with Acellular Cadaveric Dermis ($AlloDerm^{(R)}$))

  • 정보람;노태석;김영석;홍종원;나동균
    • Archives of Plastic Surgery
    • /
    • 제38권5호
    • /
    • pp.559-566
    • /
    • 2011
  • Purpose: The use of tissue expander/implant in breast reconstruction using tissue expander-implant is one of the most common surgical procedures. The use of AlloDerm as a sling to reestablish the lower pole of the pectoralis major muscle results a decrease in morbidity compared with more invasive procedures. However the use of AlloDerm is more expensive than other options. We decided to compare AlloDerm with Permacol, which has been safely used in human body reconstruction and is less costly than AlloDerm. Methods: After mastectomy, the inferolateral origin of the pectoralis major muscle was elevated. Either AlloDerm or Permacol was sutured to the chest wall at the level of the previously marked inframammary fold. The lower border of the pectoralis major muscle and the upper portion of the crescent-shaped piece of either AlloDerm or Permacol was sutured together using a tension free technique, and a tissue expander was subsequently inserted into the subpectoral-subAlloDerm (or Permacol) dual pocket. Results: AlloDerm was used in twenty-one patients (28 breasts) and Permacol was used in six patients (11 breasts) for tissue expander-implant breast reconstruction. During the mean follow-up period of 17 months (8~25 months). Two infections (7%) occurred in AlloDerm cases and four infections (36%) occurred in Permacol cases. Conclusion: This study is the first comparison of tissue expander/implant breast reconstruction using AlloDerm and Permacol. The use of Permacol resulted in more postoperative infection compared with the use of AlloDerm. This report is still limited with the small number of cases studied.

한국인 Cadaver Test에 대한 상완골 골수정 개발에 관한 연구 (A Study on Development of Humeral Intramedullary Fixation Nail based on Korean Cadaver Tests)

  • 전창수;이재원;고철웅;오종건;우수현;이성재
    • 한국정밀공학회지
    • /
    • 제28권8호
    • /
    • pp.984-991
    • /
    • 2011
  • The aim of this study is to develop a humeral Intramedullary fixation nail (HIFN) suitable for Korean people. In this study, CT images were obtained from 72 Korean cadaveric humeral bones and 3D Korean humeral bone models were reconstructed based on the CT images to investigate anatomical characteristics. Major design parameters of HIFN were selected using the morphological measurement information of the Korean humeral bone models. Through finite element analysis and mechanical tests, the developed HIFN prototype was compared with the Polarus HIFN ($ACUMED^{(R)}$, USA), and it was found that the HIFN prototype showed similar and/or superior mechanical performance compared to the Polarus HIFN. Also, clinical validation for the HIFN prototype was carried out to check predictable troubles in surgical operations. Finally, optimal design modification was proposed to prevent the possible axillary nerve injury due to the locking screw system of the HIFN prototype.

Anatomical variations and developmental anomalies of the thyroid gland in Ethiopian population: a cadaveric study

  • Dessie, Meselech Ambaw
    • Anatomy and Cell Biology
    • /
    • 제51권4호
    • /
    • pp.243-250
    • /
    • 2018
  • Because of its embryonic origin, the thyroid gland is predisposed to multiple anatomical variations and developmental anomalies. These include the pyramidal lobe, the origin of levator glandular thyroidae, the absence of the isthmus, ectopic thyroid, accessory thyroid tissues, etc. These anatomical variations are clinically significant to surgeons, anatomists, and researchers. The present study was designed to report anatomical variations and developmental anomalies of the thyroid gland in Ethiopian population. The study was conducted on 40 cadavers used for routine dissection classes. The thyroid gland was exposed and observed for any variations and developmental anomalies. The length, width, and thickness of the lobes were measured using a vernier caliper. Differences in the incidence of pyramidal lobe and absence of the isthmus between sexes were tested using a Pearson chi-square test. The mean length, width, and thickness of the right lobe were 4.24 cm, 1.8 cm, and 1.6 cm, respectively, whereas it was 4.08 cm, 1.8 cm, and 1.6 cm, respectively for that of the left lobe. The pyramidal lobe was noted in 52.5% of the cadavers. The levator glandulae thyroidae were prevalent in 40% of the cadavers. The isthmus mainly overlies the 2nd to 4th tracheal rings and was absent in 7.5% of the cadavers. Accessory thyroid tissue and double pyramidal lobes were noted in 2.5% of the cadavers. Most of the variations of the thyroid gland were seen frequently in female but it was not statically significant. Different clinically important and rare variations of the thyroid gland were found.

Scapular spine base fracture with long outside-in superior or posterior screws with reverse shoulder arthroplasty

  • Eroglu, Osman Nuri;Husemoglu, Bugra;Basci, Onur;Ozkan, Mustafa;Havitcioglu, Hasan;Hapa, Onur
    • Clinics in Shoulder and Elbow
    • /
    • 제24권3호
    • /
    • pp.141-146
    • /
    • 2021
  • Background: The purpose of the present study was to determine how long superior screws alone or in combination with posterior placement of metaglene screws protruding and penetrating into the scapular spine in reverse total shoulder arthroplasty affect the strength of the scapular spine in a fresh cadaveric scapular model. Methods: Seven fresh cadaver scapulas were allocated to the control group (short posterior and superior screws) and seven scapulars to the study group (spine base fixation with a four long screws, three with both long superior and long posterior screws). Results: The failure load was lower in the spine fixation group (long screw, 869 N vs. short screw, 1,123 N); however, this difference did not reach statistical significance (p>0.05). All outside-in long superior or superior plus posterior screws failed due to scapular spine base fracture; failures in the short screw group were due to acromion fracture. An additional posterior outside-in screw failed to significantly decrease the failure load of the acromion spine. Conclusions: The present study highlights the significance of preventing a cortical breach or an outside-in configuration when a superior or posterior screw is inserted into the scapular spine base.