• Title/Summary/Keyword: Cables

Search Result 1,577, Processing Time 0.029 seconds

Local Fault Detection Technique for Steel Cable using Multi-Channel Magnetic Flux Leakage Sensor (다채널 자속누설 센서를 이용한 강케이블의 국부 단면손상 검색)

  • Park, Seunghee;Kim, Ju-Won;Lee, Changgil;Lee, Jongjae;Gil, Heung-Bae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.4
    • /
    • pp.287-292
    • /
    • 2012
  • In this study, Multi-Channel Magnetic Flux Leakage(MFL) sensor - based inspection system was applied to monitor the condition of cables. This inspection system measures magnetic flux to detect the local faults(LF) of steel cable. To verify the feasibility of the proposed damage detection technique, an 8-channel MFL sensor head prototype was designed and fabricated. A steel cable bunch specimen with several types of damage was fabricated and scanned by the MFL sensor head to measure the magnetic flux density of the specimen. To interpret the condition of the steel cable, magnetic flux signals were used to determine the locations of the flaws and the level of damage. Measured signals from the damaged specimen were compared with thresholds set for objective decision making. In addition, the magnetic flux density values measured from every channel were summed to focus on the detection of axial location. And, sum of flux density were displayed with threshold. Finally, the results were compared with information on actual inflicted damages to confirm the accuracy and effectiveness of the proposed cable monitoring method.

Structural Design and Analysis of a Hydraulic Coiling Arm for Offshore Wind-turbine Submarine Cable (해상풍력 해저케이블 하역용 유압식 코일링 암 구조설계 및 해석)

  • Kim, Myung-Hwan;Kim, Dong-Hyun;Oh, Min-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Structural design and analysis of a coiling arm unloading machine for submarine cable have been originally conducted in this study. Three-dimensional CAD modeling process is practically applied for the structural design in detail. Finite element method(FEM) and multi-body dynamics(MBD) analyses are also used to verify the safety and required motions of the designed coiling arm structure. The effective moving functions of the designed coiling arm with respect to rotational and radial motions are achieved by adopting bearing-roller mechanical parts and hydraulic system. Critical design loading conditions due to its self weight, carrying cables, offshore wind, and hydraulic system over operation conditions are considered for the present structural analyses. In addition, possible inclined ground conditions for the installation of the designed coiling arm are also considered to verify overturn stability. The present hydraulic type coiling arm system is originally designed and developed in this study. The developed coiling arm has been installed at a harbor, successfully tested its operational functions, and finished practical unloading mission of the submarine cable.

A study on digital locking device design using detection distance 13.4mm of human body sensing type magnetic field coil (인체 감지형 자기장 코일의 감지거리 13.4mm를 이용한 디지털 잠금장치 설계에 관한 연구)

  • Lee, In-Sang;Song, Je-Ho;Bang, Jun-Ho;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.9-14
    • /
    • 2016
  • This study evaluated a digital locking device design using detection distance of 13.4mm of a human body sensing type magnetic field coil. In contrast to digital locking devices that are used nowadays, the existing serial number entering buttons, lighting, number cover, corresponding pcb, exterior case, and data delivery cables have been deleted and are only composed of control ON/OFF power switches and emergency terminals. When the magnetic field coil substrates installed inside the inner case detects the electric resistance delivered from the opposite side of the 12mm interval exterior contacting the glass body part, the corresponding induced current flows. At this time, the magnetic field coil takes the role as a sensor when coil frequency of the circular coil is transformed. The magnetic coil as a sensor detects a change in the oscillation frequency output before and after the body is detected. This is then amplified to larger than 2,000%, transformed into digital signals, and delivered to exclusive software to compare and search for embedded data. The detection time followed by the touch area of the body standard to a $12.8{\emptyset}$ magnetic field coil was 30% contrast at 0.08sec and 80% contrast at 0.03sec, in which the detection distance was 13.4mm, showing the best level.

Development of Ubiquitous Sensor Network Intelligent Bridge System (유비쿼터스 센서 네트워크 기반 지능형 교량 시스템 개발)

  • Jo, Byung Wan;Park, Jung Hoon;Yoon, Kwang Won;Kim, Heoun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.120-130
    • /
    • 2012
  • As long span and complex bridges are constructed often recently, safety estimation became a big issue. Various types of measuring instruments are installed in case of long span bridge. New wireless technologies for long span bridges such as sending information through a gateway at the field or sending it through cables by signal processing the sensing data are applied these days. However, The case of occurred accidents related to bridge in the world have been reported that serious accidents occur due to lack of real-time proactive, intelligent action based on recognition accidents. To solve this problem in this study, the idea of "communication among things", which is the basic method of RFID/USN technology, is applied to the bridge monitoring system. A sensor node module for USN based intelligent bridge system in which sensor are utilized on the bridge and communicates interactively to prevent accidents when it captures the alert signals and urgent events, sends RF wireless signal to the nearest traffic signal to block the traffic and prevent massive accidents, is designed and tested by performing TinyOS based middleware design and sensor test free Space trans-receiving distance.

Reliability-Based Assessment of Structural Safety of Steel-Concrete Hybrid Cable-Stayed Bridge Erected by the FCM and FSM during Construction (FCM과 FSM공법에 의한 강-콘크리트 복합사장교의 신뢰성에 기초한 시공간 구조안전도평가)

  • Yoon, Jung Hyun;Cho, Hyo Nam
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.5
    • /
    • pp.515-526
    • /
    • 2007
  • In this study, the models and methods for the safety assessment of Steel-Concrete Hybrid Cable-Stayed Bridge, which consists of steel composite girder and concrete girder erected by the FCM(Free Cantilever Method) and FSM(Full Staging Method) are proposed for the assurance of structural safety and the prevention against bridge collapse during construction. By the structural reliability approach that reasonably considers the uncertainties associated with the resistance and the load effect, the resistance and the load distribution characteristics of Steel-Concrete Hybrid Cable-Stayed Bridgeare defined and the strength limit state equations of permanent structures and temporary structures during construction are suggested. An AFOSM algorithm and MCS technique are used for the reliability analysis of cables, pylons, girders, steel-concrete conjunction part and temporary bents. Also, component reliability analyses are performed at the construction stages based on the structural system model. To demonstrate their rationality and practicality, the proposed models and approaches are applied to a real bridge. The sensitivity analyses of main parameters are performed in order to identify the critical factors that control the safety of similar bridges. As a result, it may be stated that the proposed models could be implemented as a rational and practical approach for the safety assessment of Steel-Concrete Hybrid Cable-stayed bridges erected by FCM and FSM during construction.

Study on the Efficient Application of Vision-Based Displacement Measurements for the Cable Tension Estimation of Cable-Stayed Bridges (사장교 케이블의 장력 추정을 위한 영상변위 측정법의 효율적 적용에 대한 연구)

  • Lee, Hyeong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.709-717
    • /
    • 2016
  • In this study, the convenience and efficiency of vision-based displacement measurement (VBDM) to estimate the cable tension of cable-stayed bridges and the requirements for its effective application were examined. To demonstrate its convenience and efficiency, it was confirmed that VBDM can be accomplished with a minimum amount of equipment using a commercial camcorder. In this case, it was found that the accuracy of estimation of the natural frequencies is sufficient, even though magnitude errors can occur when conducting high-speed recording at the low resolution afforded by the minimal equipment employed. It was also confirmed that the most important factor in detecting the precise natural frequencies is the use of the appropriate frequency range in the tension estimation using vibration. Based on these results, a study was carried out on the accuracy variation of the estimated tension according to the frame rate of a commercial camcorder. For this purpose, an experiment was performed to estimate the cable tension in a cable-stayed bridge model. Through this experiment, the detectable tensions of cables with various natural frequencies as a function of the frame rate were summarized. As a result, it was shown that the frame rate should be determined based on the natural frequency which is estimated to be located within the appropriate frequency range (approximately 10~75% of theoretical range) considering the aliasing and low-frequency distortion due to excitations.

Pin Distribute Method of Twist Cable at Military Unmanned Vehicle Wiring Unit Connector (군용 무인 이동체 배선장치 커넥터에서 트위스트 케이블 핀 배치 최적화 방안)

  • Eun, Hee-hyun;Roh, Dong-gyu;Kwak, Gyu-min;Kim, Jae-seung;Lee, Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.4
    • /
    • pp.245-250
    • /
    • 2020
  • Currently, unmanned military vehicles under development in Korea have more devices to carry out various missions, and interface cables between them are also increasing. In addition, due to a small space problem inside the unmanned vehicle, devices are required to be miniaturized and integrated. For two reasons, connectors also need to be selected, which makes them vulnerable to noise due to the closer distance between the pins. In this paper, we analyzed how much the magnetic field produced by noise at the connector pin where cable twist is released affects the surrounding pin and presented the guide for optimal pin placement. First, the effect of magnetic field is greater than the crosstalk between pin and pin. Second, the magnetic field on both sides between + and - is strong when approaching one step with noise source. Third, the magnetic field strength is improved when setting the ground pin as the ground pin between the noise and the original signal when approaching the A noise source and the two steps. Fourth, in the case of a differential mode communication, the optimal placement area of the sensitive signal was presented according to positions Tx± and Rx±.

Study on the Air Insulation Design Guideline for ±500 kV Double Bipole Transmission Line with Metallic Return Conductor (도체귀로형 ±500 kV Double Bipole 송전선로 공기절연에 관한 연구)

  • Shin, Kooyong;Kwon, Gumin;Song, Seongwhan;Woo, Jungwook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.141-147
    • /
    • 2019
  • Recently, the biggest issue in the electricity industry is the increase in renewable energy, and various technologies are being developed to ensure the capacity of the power system. In addition, super-grids linking power systems are being pushed to utilize eco-friendly energy between countries and regions worldwide. The HVDC transmission technology is required to link the power network between regions with different characteristics of the power system such as frequency and voltage. Until now, Korea has applied HVDC transmission technology that connects mainland and Jeju Island with submarine cables. But, the HVDC transmission technology is still developing for long-distance high-capacity power transmission from power parks on the east coast to load-tight areas near the metropolitan area. Considering the high population density and mountainous domestic environment, it is pushing for commercialization of the design technology of the ${\pm}500kV$ Double Bipole with metallic return wire transmission line to transmit large-scale power of 8 GW using minimal right of ways. In this paper, the insulation characteristics were studied for the design of double-bipole transmission tower with metallic return wire, which is the first time in the world. And the air insulation characteristics resistant to the various overvoltage phenomena occurring on transmission lines were verified through a full-scale impulse voltage test.

Development and Simulation of a Detecting Method using Reflectometry of Electrical Signal (전기적 신호의 반사파 측정법을 적용한 부식 진단 기술의 개발 및 시뮬레이션)

  • Yoon, Seung Hyun;Bang, Su Sik;Shin, Yong-June;Lim, Yun Mook
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.6
    • /
    • pp.367-372
    • /
    • 2018
  • Defects in aging infrastructures such as pre-stressed concrete bridges and cable bridges can cause a collapse of the entire structure. Defects, however, are often located inside of the structures that they are not visible from the outside. For example, in PSC bridges, because reinforcement steels are encased by exterior covers, corrosion and void on the reinforcement steel cannot be detected with a visual inspection. Therefore, in this paper, a new non-destructive evaluation(NDE) method that can detect defects inside of structures is presented. The new method utilizes sending of electrical signals, a method often utilized in electrical engineering to detect any discontinuities on power cables. In order to confirm the applicability and accuracy of the method, some experiments were conducted in the laboratory. And to overcome the hardship of conducting experiments on real structures due to their enormous size, simualtions were conudcted using a commercial program, COMSOL. The results of the experiments were analyzed and compared to confirm the accuracy of the simualtions.

Possibility of Fishery in Offshore Wind Farms (해상풍력발전단지 내 어업 가능성에 관한 고찰)

  • Jung, Cho-Young;Hwang, Bo-Kyu;Kim, Sung-Cheol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.535-541
    • /
    • 2019
  • The purpose of this study was to investigate the possibility of fishery in offshore wind farms and evaluate the risk linked to the presence of turbines and submarine cables in these areas. With this objective, we studied an offshore wind farm in the Southwest Sea and the current state of vessels in the surrounding National Fishing Port. The risk assessment criteria for 22 fishing gears and methods were set by referring to the fishing boats; thereafter, the risk was assessed by experts. The fishing gears and methods that could be safely operated (i.e., associated with low risk) in the offshore wind farm were: single-line fishing, jigging, and the anchovy lift net. The risk was normal so that it is possible to operate, but the fishing gears and methods that need attention are: the set long line, drifting long line, troll line, squid rip hook, octopus pot, webfoot octopus pot, coastal fish pot, stow net on stake, winged stow net, stationary gill net, and drift gill net. Moreover, the fishing gears and methods difficult to operate in the of shore wind farm (i.e., associated with high risk) were: the dredge, beam trawl, and purse seine. Finally, those associated with very high risk and that should not be allowed in offshore wind farms were: the stow net, anchovy drag net, otter trawl, Danish seine, and bottom pair trawl.