• Title/Summary/Keyword: Cable Tree

Search Result 107, Processing Time 0.03 seconds

A Tabu Search Heuristic Algorithm for Hierarchical Location Allocation Problem (광대역 융합 가입자 망 설계를 위한 타부서치 알고리즘 개발)

  • Park, Gi-Gyeong;Lee, Yeong-Ho;Kim, Yeong-Uk
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2008.10a
    • /
    • pp.131-135
    • /
    • 2008
  • In this paper, we deal with a hierarchical location-allocation problem in designing the broadband convergence networks (BcN). The objective is to minimize the total cost of switch and cable while satisfying the quality of service (QoS). We formulate the problem as an integer programming model and develop the Tabu Search (TS) heuristic algorithm to find a good feasible solution within a reasonable time limit. Initial solution is obtained by using the tree structure. Three neighborhood generation mechanisms are used by local search heuristic: insertion, switch up, and switch down. In order to demonstrate the effectiveness of the proposed algorithm, we generate lower bounds from nonlinear QoS relaxation problem. We present promising computational results of the proposed solution procedures.

  • PDF

Field Test Results for Water-tree Diagnosis Technologies of Domestic Underground Distribution Cable (국내 지중배전케이블에 대한 수트리 열화진단기술 현장 시험 결과)

  • Lee, Jae-Bong;Joung, Jong-Man;Park, Chul-Bae;Lee, Jae-Ok;Mok, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.506-507
    • /
    • 2006
  • 1986년 제조되어 국내 지중배전계통의 관로에서 20년간 사용된 CNCV케이블에 대하여 IRC(Iso-thermal Relaxation Current) 측벙법을 사용하는 진단장비와 0.1Hz 극저주파 Tan-delta 측정법을 사용하는 진단장비로 케이블의 수트리 열화 진단을 시행하고 철거한 후 교류파괴전압시험을 수행하였다 각 진단장비의 진단결과와 교류파괴전압시험 결과, 수트리의 존재여부를 비교하였다. VLF Tan-delta 측정법을 사용하는 진단장비가 교류파괴전압시험결과, 수트리의 유무 둥과 상관성이 비교적 높게 나타났다. 통계적으로 신뢰성을 확보할 수 있도록 지속적인 비교 검증시험을 추진할 계획이다.

  • PDF

The Study on Treeing under the Temperature Variation in Low Density Polyethylene Mixed with Dodecyl Alcohol (Dodecyl Alcohol이 첨가된 P.E에서 온도변화에 따른 Treeing에 관한 연구)

  • Lee, Chang-Hee;Lee, Kye-An;Kim, Sang-Jun;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.75-78
    • /
    • 1989
  • Insulation of P.E insulated cable under the field of high-voltage will be breakdown ultimately due to the degradation process called 'Treeing' which is generated in the insulation, so long as any counter-measure suppressing or eliminating it could not be provided. In this paper as a counter-measure Dodecyl Alcohol is mixed with P.E and Treeing under the temperature variation has been observed. Results show that the larger weight ratio of Dodecyl Alcohol is stronger the effect of suppressing Tree ing in the range from room temperature to 40$^{\circ}C$ and generated Treeing has been soon eliminated and it never again generated.

  • PDF

Study of Partial Discharge Degradation of Insulating Materials in Liquid Nitrogen (액체$N_2$중 절연재료의 부분방전 열화 연구)

  • Kim, H.H.;Kim, S.H.;Ma, D.Y.;Chang, J.K.;NamGung, D.;Cho, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.406-410
    • /
    • 1995
  • A superconducting cable is one of the promising methods of undground transmission of high electric power in the future. It is very important that composite insulation system of $LN_2$ and polymer films takes into consideration for application high $T_c$ superconductor. This study is about both the partial discharge and properties V-t in $LN_2$. As result, applied voltage doesn't depend on the radius of non-eroded area but eroded area. And eroded area is observed the formation such as the ring of a tree.

  • PDF

A Study on Discharge Statistics Quantities for Deterioration Diagnosis of Branch-type Tree (가지형 트리의 열화진단을 위한 방전통계량에 관한 연구)

  • Shin, S.K.;Kim, K.M.;Kim, T.Y.;Lee, D.J.;Park, C.O.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2345-2348
    • /
    • 1999
  • Existing $\psi$-AEA-t (phase-AEA-time) characteristic in polymer materials for power cable is good in general deterioration characteristic according to time variation, but it is difficult to clearly distinguish from deterioration state and diagnosis of deterioration is not enough to some extent. This paper is interpreted AE discharge statistics quantities measuring phase-amplitude variation of acoustic emission characteristic obtained from treeing breakdown experiment. Besides it can know useful discharge statistics quantities (AE average inception phase/amplitude, AE average maximum phase/amplitude) about so many for diagnosis of treeing deterioration.

  • PDF

A study on insulation Characteristics of XLPE by various additives (다양한 첨가제에 따른 가교폴리에틸렌의 절연특성 분석)

  • Song, Sang-Min;Kim, Gyu-Sik;Son, Won-Keun;Ryu, Boo-Hyung;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.193-196
    • /
    • 2001
  • XLPE is occasionally happened to deteriorate cable insulation characteristics. It is happened to do a breakdown state by the degradation of electrical characteristic and electrical breakdown strength. I prepared TR-XLPE (Tree-Retardant XLPE) as adding various additives to prevent its states. Various additives are treeing retardants, anti-oxidants. Treeing retardants three kinds of aromatic compounds as adding each additive. Anti-oxidants use quinone compound and cresol compound as adding each additive. In order to observe each electrical characteristics, I measured breakdown strength, relative dielectric constant$({\varepsilon}_r)$, dielectric loss tangent$(tan{\delta})$. TR-XLPE specimens as adding treeing retardants and anti-oxidants enhance breakdown strength, ${\varepsilon}_r$, $tan{\delta}$ than pure XLPE.

  • PDF

The Study of Multi-Circuit Breaker Coordination in the Underground Distribution Line (지중배전선로의 다회로차단기 운영방안 연구)

  • Jo, Nam-Hun;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.4
    • /
    • pp.143-151
    • /
    • 2000
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the distribution line, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. On underground distribution line, the serving of cables by earth-moving equipment is a prevalent cause of faults and the most cable faults quickly develop into bolted current. we introduce th multi-circuit breaker coordination methods in the Underground Distribution Line.

  • PDF

Desing and Verification of Satellite B-ISDN Signalling Protocol (위성 B-ISDN 신호 프로토콜의 설계 및 검증)

  • Park, Seok-Cheon;Choe, Dong-Yeong;Gang, Seong-Yong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.7
    • /
    • pp.1909-1918
    • /
    • 1999
  • The terrestrial/satellite hybrid network may replace or supply the terrestrial network in some areas or certain applications. For example, it may play a major role in global B-ISDN or in certain areas where the deployment of optical cable is not feasible, especially at the early stage of implementing terrestrial B-ISDN. Furthermore, it can play an important role in the development of B-ISDN due to their features of flexible wide coverage, independent of ground distances and geographical constraints, multiple access and multipoint broadcast. Also, satellite have the capability to supply terrestrial B-ISDN/ATM with flexible links for access networks as well as trunk networks. This paper describes the design and verification of the interworking protocol between terrestrial B-ISDN뭉 satellite network. For the verification, the designed interworking protocol is modeled by Petri-net and the model is analyzed by reachability tree.

  • PDF

Selection of measurement sets in static structural identification of bridges using observability trees

  • Lozano-Galant, Jose Antonio;Nogal, Maria;Turmo, Jose;Castillo, Enrique
    • Computers and Concrete
    • /
    • v.15 no.5
    • /
    • pp.771-794
    • /
    • 2015
  • This paper proposes an innovative method for selection of measurement sets in static parameter identification of concrete or steel bridges. This method is proved as a systematic tool to address the first steps of Structural System Identification procedures by observability techniques: the selection of adequate measurement sets. The observability trees show graphically how the unknown estimates are successively calculated throughout the recursive process of the observability analysis. The observability trees can be proved as an intuitive and powerful tool for measurement selection in beam bridges that can also be applied in complex structures, such as cable-stayed bridges. Nevertheless, in these structures, the strong link among structural parameters advises to assume a set of simplifications to increase the tree intuitiveness. In addition, a set of guidelines are provided to facilitate the representation of the observability trees in this kind of structures. These guidelines are applied in bridges of growing complexity to explain how the characteristics of the geometry of the structure (e.g. deck inclination, type of pylon-deck connection, or the existence of stay cables) affect the observability trees. The importance of the observability trees is justified by a statistical analysis of measurement sets randomly selected. This study shows that, in the analyzed structure, the probability of selecting an adequate measurement set with a minimum number of measurements at random is practically negligible. Furthermore, even bigger measurement sets might not provide adequate SSI of the unknown parameters. Finally, to show the potential of the observability trees, a large-scale concrete cable-stayed bridge is also analyzed. The comparison with the number of measurements required in the literature shows again the advantages of using the proposed method.

Identification of Normally Operating High-Voltage Cables beyond Expected Life time (예상 수명을 초과하여 정상적으로 동작하는 고압 케이블의 확인)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.5
    • /
    • pp.207-212
    • /
    • 2015
  • Continuous, high-quality supply of electrical energy is the backbone of any modern economy. Any equipment operating at a power station must be reliable and safe. All major power supply components such as transformers, cables, generators, and switchgear need to be kept in perfect operating condition. The lifetime of power cables, used as the main means of transferring electric power, is understood to be about 30 years, from the time of manufacturing. The dielectrics between two conductors of a cable must be able to withstand electrical stresses from high-voltage input. This condition should be verified throughout the lifetime of the cable system. Several techniques, such as VLF-tan${\delta}$, partial discharge, and insulation resistance are used in order to determine the operating conditions of cables. In this paper, we present our work on insulation resistance to diagnose cables in operation at the Western Power station in Taean, Chungcheong Namdo Province, South Korea. As a result we have found cables the life time of which is 38 years.