Power plant instrumentation and control system by using optical fiber cable (광케이블을 이용한 발전소 계측제어시스템)

  • 신건학;조홍근;오면택
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.79-84
    • /
    • 1990
  • Analog systems could not fully deal with instrumentation and control facilities in power plants since these facilities have become more and more complex on account of various needs for large power generation capacity highly cost effective operation to conserve energy and operation management to prevent pollution. Digitalizations of control device and augmentations of control informations increased the necessity of fiber optic data networks which have excellent noise immunity and high quality wide-band with information transfer capability. The goal of this study is to offer a fiber optic data-way system which has high reliabilities, high data transmission rates and small cable ducts with large transmission capacities for the instrumentation and control of power plants.

  • PDF

Performance Improvement of Channel Access Control Method in Wireless Mesh Networks (무선 메쉬 네트워크에서 성능향상을 위한 채널접속 제어 방법)

  • Lee, Soon-Sik;Yun, Sang-Man;Lee, Sang-Wook;Jeon, Seong-Geun;Kim, Eung-Soo;Lee, Woo-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.572-580
    • /
    • 2010
  • The Wireless Mesh Network uses a wireless communication technology with transmission rates simular to a cable which is used as a backbone networks. The topology structure is in a Mesh form which resembles an Ad-hoc networks. However, a metric is needed in order to set the channel access control method to operate intentions and interior motions are different. In this document, an efficient channel for delivering datas to improve access controls to a wireless mesh networks. The improved performance of the proposed plan is for a hidden and exposed mesh client through an exclusive channels to perform a proposed and analyzed methods.

A versatile software architecture for civil structure monitoring with wireless sensor networks

  • Flouri, Kallirroi;Saukh, Olga;Sauter, Robert;Jalsan, Khash Erdene;Bischoff, Reinhard;Meyer, Jonas;Feltrin, Glauco
    • Smart Structures and Systems
    • /
    • v.10 no.3
    • /
    • pp.209-228
    • /
    • 2012
  • Structural health monitoring with wireless sensor networks has received much attention in recent years due to the ease of sensor installation and low deployment and maintenance costs. However, sensor network technology needs to solve numerous challenges in order to substitute conventional systems: large amounts of data, remote configuration of measurement parameters, on-site calibration of sensors and robust networking functionality for long-term deployments. We present a structural health monitoring network that addresses these challenges and is used in several deployments for monitoring of bridges and buildings. Our system supports a diverse set of sensors, a library of highly optimized processing algorithms and a lightweight solution to support a wide range of network runtime configurations. This allows flexible partitioning of the application between the sensor network and the backend software. We present an analysis of this partitioning and evaluate the performance of our system in three experimental network deployments on civil structures.

A Study on the Standards of Open Information About Telecommunications Facilities for Promoting FTTH Investment (FTTH망 투자 촉진을 위한 전기통신설비의 정보제공 기준에 관한 연구)

  • Cho, Eun-jin;Kweon, Soo-cheon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.674-677
    • /
    • 2009
  • The one of the big issues in fixed markets is the investment of next generation networks. The nation-wide incumbent has provided the copper cable based access networks in so far. However in the future multiple providers participant in investing network in first stage of the network investment like mobile networks. Each NRA makes efforts on the resolving construction cost of civil engineering costs through the opening conduits. To smooth operation, information opening service is needed then NRAs must determined the level of opened information and cost of usage information and so on. This paper proposed the alternation of the issues to boost the investment of the next generation networks.

  • PDF

Review of the Conceptual Design for the use of the HTS Cable to Power System (고온초전도케이블의 계통적용을 위한 개념설계)

  • Choi, Sang-Bong;Kim, Dae-Kyeong;Jeong, Seong-Hwan;Moon, Young-Hwan;Seong, Ki-Chul;Kim, Hak-Man
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.253-255
    • /
    • 2002
  • The necessity of compact high temperature super conducting cables is more keenly felt in densely populated metropolitan areas. As the compact high temperature superconducting cables that can be installed in ducts and tunnels can reduce construction cost and make the use of underground space more effective, the effect of introducing it to power system will be huge. For this study, Seoul, Korea is selected as a review model, the loads are estimated by scenario based on a survey and analysis of 345kV and 154kV power supply networks in this area. Based on this, the following items on urban transmission system are examined. (1) A method of constructing a model system to introduce high temperature superconducting cables to metropolitan areas is presented. (2) A case study through the analysis of power demand is conducted, and the amount of high temperature superconducting cable to be introduced by scenario is examined. (3) The economy involved in expanding existing cables and introducing high temperature superconducting cables(ducts or tunnels) following load increase in urban areas is examined and compared. (4) The maximum external diameter of HTS cable to accommodate exiting ducts based on the design standards for current cable ducts is calculated. (5) The voltage level that can be accommodated by existing ducts is examined.

  • PDF

Design of a High Speed Asymmetric Baseband MODEM ASIC Chip for CATV Network (CATV 망용 고속 비대칭 기저대역 모뎀 ASIC 칩 설계)

  • 박기혁
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.9A
    • /
    • pp.1332-1339
    • /
    • 2000
  • This paper presents the architecture and design of a high speed asymmetric data transmission baseband MODEM ASIC chip for CATV networks. The implemented MODEM chip supports the physical layer of the DOCSIS(Data Over Cable Service Interface Specification) standard in MCNS(Multimedia Cable Network System) The chip consists of a QPSK/16-QAM transmitter and a 64/256-QAM receiver which contain a symbol timing recovery circuit, a carrier recovery circuit, a blind equalizer using MMA and LMS algorithms. The chip can support data rates of 64Mbps at 256 QAM and 48Mbps at 64-QAM and can provide symbol rates up to 8MBaud. This symbol rate is faster than existing QAM receivers. We have performed logic synthesis using the $0.35\mu\textrm{m}$ standard cell library. The total number of gates is about 290,000 and the implemented chip is being fabricated and will be delivered soon.

  • PDF

The Reduction Method for Radiated EMI in USB Power Line of Cable (USB 케이블의 전원선 에서의 방사성 EMI 개선)

  • Park, Kyoung-Jin;Lee, Dae-Woo;Ko, Yong-Mok;Gang, Eun-Gyun;Park, Jong-Hyun;Kim, Keun-Yong;Ra, Keuk-Whan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.201-208
    • /
    • 2013
  • In this paper, we studied on improvement for radiated EMI of USB power line of cable. it is made by using wireless video access point system for confirming the phenomenon of radiated EMI from cable. then, we make sure that the limit exceed through the initial measurement of radiated EMI limit criteria in comparison to about 3 [dBuV/m]~15 [dBuV/m]. after that we confirmed the resonance in power line of cable through measurement of s-parameters. so, we confirmed the relation radiated EMI and power line of cable resonance and we reduced radiated EMI in power line of cable through a capacitor and low pass-band filter using the technique of power networks management. in conclusion, we suggested how to reduce power line of cable resonance applied for the improved method. and we confirmed that suggested reduction method is suitable through testing radiated EMI. the result of radiated EMI reduction limit criteria 40[dBuV/m]~47[dBuV/m] in comparison to about 3 [dBuV/m]~20 [dBuV/m].

The Distribution Automation System - its communication techniques (배전자동화시스템의 정보통신 설계로 구현 사례)

  • Kim, Myong-Soo;Ko, Sang-Chon;Lee, Sang-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3015-3017
    • /
    • 1999
  • KEPCO is faced with a number of network choice for Distribution Automation System(DAS), such as Power Line, Pair. Coaxial and Optical Cable, etc. The increasing use of DAS requires suitable communication networks. KEPCO has exhausted much efforts to implement its own standard DAS in possible early date. This paper presents the DAS in KEPCO and some of initial design efforts toward KEPCO's DAS at KEPRI.

  • PDF

An investment cost model for metropolitan area subscriber networks (대도시 가입자망 투자비 산출 모형의 개발)

  • Hwang, Geon;Chang, Seok-Gwon;Kim, Sa-Hyeok
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1997.10a
    • /
    • pp.239-242
    • /
    • 1997
  • Subscriber network investment cost is a main cost element among those constituting the access charges in telephone networks. The purpose of this paper to estimate the investment cost of installing a subscriber network in a typical metropolitan area and to develop a cost modeling framework. To this aim, a metropolitan area in Seoul was investigated. The main cost elements were identified and their relationships with the cable technology, geographical characteristics, and the number of subscribers were analyzed. The findings could be used to design an enhanced cost proxy models for estimating the access charges in a multi-operator environment.

  • PDF

Comparison of BP and SOM as a Classification of PD Source (부분방전원의 분류에 있어서 BP와 SOM의 비교)

  • 박성희;강성화;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.9
    • /
    • pp.1006-1012
    • /
    • 2004
  • In this paper, neural networks is studied to apply as a PD source classification in XLPE power cable specimen. Two learning schemes are used to classification; BP(Back propagation algorithm), SOM(self organized map - kohonen network). As a PD source, using treeing discharge sources in the specimen, three defected models are made. And these data making use of a computer-aided discharge analyser, statistical and other discharge parameters is calculated to discrimination between different models of discharge sources. And a]so these distribution characteristics are applied to classify PD sources by two scheme of the neural networks. In conclusion, recognition efficiency of BP is superior to SOM.