• Title/Summary/Keyword: Cable Induction System

Search Result 29, Processing Time 0.027 seconds

Analysis of Overvoltage Distribution in Low-Voltage Induction Motor Due to Inverter Switching Surge (인버터 스위칭 써지에 의한 저압 유도전동기의 과도전압 분포해석)

  • Hwang, Don-Ha;Kim, Yong-Joo;Lee, In-Woo;Bae, Sung-Woo;Kim, Dong-Hee;Ro, Chae-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1151-1153
    • /
    • 2003
  • In this paper, switching surge voltage distribution in stator windings of induction motor driven by IGBT PWM inverter is studied. To analyze the irregular voltage of stator winding, equivalent circuit model of inverter-cable-motor was proposed and high frequency parameter is computed by using finite element method (FEM). Electromagnetic transient program (EMTP) analysis of the whole system for induction motor and PWM inverter is proposed. In order to experiment, an induction motor, 380 [V], 50 [HP], with taps from one phase and a switching surge generator was built to consider the voltage distribution.

  • PDF

Analysis of Overvoltage Distribution in Stator Winding of Induction Motor Driven by IGBT PWM Inverter (IGBT 인버터 구동 유도전동기 고정자 권선에서의 과도전압 분포 해석)

  • Bae S. W.;Hwang D. H.;Kim Y. J.;Kim D. H.;Kim M. H.;Lee I. W.
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.17-20
    • /
    • 2002
  • In this paper voltage distribution in stator windings of induction motor driven by IGBT PWM inverter is studied. To analyze the irregular voltage of stator winding, equivalent circuit model of inverter-cable-motor was proposed and high frequency parameter is computed by using finite element method (FEM). Electro-magnetic transient program (EMTP) analysis of the whole system for induction motor and PWM inverter is proposed. Induction motor, 50[HP], and a switching surge generator was built to consider the voltage distribution. The results of EMTP analysis compared with experimental results.

  • PDF

System Fault Analysis of Inverter Fed Induction Motor drives (인버터 구동 유도전동기의 계통사고 해석)

  • Kwon Young Mok;Kim Jae Chul;Song Seung Yeop;Shin Joong Eun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.304-306
    • /
    • 2004
  • Recently, operating equipment with the high quality is necessary as technology is developing rapidly and equipment becomes more accurate. Therefore, the importance of diagnosis has been rising in modem industries. This paper presents that the induction motor is driven by invertor. We were using EMTP (Electromagnetic Transient Program) to study different characteristics of induction motor caused by faults; single phasing and the short circuit fault. After having the fault occurred in feeder cable, motor current, flux and torque waveform are analyzed

  • PDF

Environmental Test of Avionics Equipment for Lightning Indirect Effect (낙뢰 간접영향에 대한 항공전자장비의 환경시험)

  • Jeong, Duck-young;Yang, Hyun-duck
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.2
    • /
    • pp.55-59
    • /
    • 2013
  • Before avionics equipment are installed in aircraft, several environmental tests such as temperature, vibration, lightning, fire etc. must be conducted. One of the environmental tests is to substantiate protection designs of lightning indirect effect. It can be showed through RTCA DO-160G, section22 "Lightning Induced Transient Susceptibility" test. An additional test of aircraft level is required as well after installation of avionics equipment.

Vibration Control of Stay Cable Using Smart Passive Damping System (스마트 수동 감쇠 시스템을 이용한 사장 케이블의 진동 제어)

  • Jung Hyung-Jo;Cho Sang-Won;Jang Ji-Eun;Lee In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.497-504
    • /
    • 2005
  • Stay cables, such as are used in cable-stayed bridges, are prone to vibration due to their low inherent damping characteristics. Several methods have been proposed and implemented to mitigate this problem, though each has its limitations. Recently some studies have shown that active and semiactive control system using MR (Magnetorheological) damper can potentially achieve both higher performance levels than passive control system and adaptability with few of the detractions. However, a control system including a power supply, controller, and sensors is required to maximize the performance of the MR damper and this complicated control system is not effective to most of large civil structures. This paper proposes a smart passive damping system using MR dampers by introducing electromagnetic induction (EMI) system as an external power source to MR damper and verified the performance of smart passive damping system for mitigating the vibration of stay cables. The performances of smart passive damping system are compared with those of linear viscous damper and passive-mode MR damper.

  • PDF

Robust Design for Parts of Induction Bolt Heating System (유도가열시스템의 구성부품에 대한 강건설계)

  • Kim, Doo Hyun;Kim, Sung Chul;Lee, Jong Ho;Kang, Moon Soo;Jeong, Cheon Kee
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.10-17
    • /
    • 2021
  • This paper presents the robust design of each component used in the development of an induction bolt heating system for dismantling the high-temperature high-pressure casing heating bolts of turbines in power plants. The induction bolt heating system comprises seven assemblies, namely AC breaker, AC filter, inverter, transformer, work coil, cable, and CT/PT. For each of these assemblies, the various failure modes are identified by the failure mode and effects analysis (FMEA) method, and the causes and effects of these failure modes are presented. In addition, the risk priority numbers are deduced for the individual parts. To ensure robust design, the insulated-gate bipolar transistor (IGBT), switched-mode power supply (SMPS), C/T (adjusting current), capacitor, and coupling are selected. The IGBT is changed to a field-effect transistor (FET) to enhance the voltage applied to the induction heating system, and a dual-safety device is added to the SMPS. For C/T (adjusting current), the turns ratio is adjusted to ensure an appropriate amount of induced current. The capacitor is replaced by a product with heat resistance and durability; further, coupling with a water-resistant structure is improved such that the connecting parts are not easily destroyed. The ground connection is chosen for management priority.

Smart Passive System Based on MR Damper (MR댐퍼 기반의 스마트 수동제어 시스템)

  • Cho, Sang-Won;Jo, Ji-Seong;Kim, Chun-Ho;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.51-59
    • /
    • 2005
  • Magnetorheological(MR) dampers are one of the most promising semi active control devices, because they have advantages such as small power requirement, reliability, and low price to manufacture. To reduce the responses of structures with MR dampers, a control system including power supply, controller, and sensors is required. However, when a mount of MR dampers are used to a large?scale civil structure such as cable stayed bridges, the control system becomes complex. Therefore, it is not easy to install and maintain the MR damper based control system. To resolve above difficulties, This paper proposes a smart passive system that consists of a MR damper and an electromagnetic induction(EMI) system. According to the Faraday’s law of induction, EMI system that is attached to the MR damper produces electric energy. The produced energy is supplied to the MR damper. Thus, the MR damper with EMI system does not require any power at all. Furthermore, the induced electric energy is proportional to external loads like earthquakes, which means the MR damper with EMI system is adaptable to external loads without any controller and corresponding sensors. Therefore, it is easy to build up and maintain the proposed smart passive system.

The Study on the AC Interference of High Power Cable on Underground Gas Pipeline (전력케이블과 가스배관의 병행구간에 대한 교류부식 영향 검토 연구)

  • Bae, J.H.;Kim, D.K.;Ha, T.H.;Lee, H.G.;Kwak, B.M.;Lim, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.470-473
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power. Therefore, there has been and still is a growing concern (safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline. especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion, limitation of safety voltage and analysis of indiction voltage.

  • PDF

Output filter design for conducted EMI reduction of PWM Inverter-fed Induction Motor System

  • Kim Lee-Hun;Won Chung-Yuen;Kim Young-Seok;Choi Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.761-767
    • /
    • 2001
  • In this paper, filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives will be examined. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections, ringing, and the dv/dt, di/dt. Therefore, filtering techniques are investigated to reduce the motor terminal overvoltage, ringing, and EMI noise in inverter fed ac motor drive systems. The output filter is used to limit the rate of the inverter output voltage and reduce EMI(common mode noise) to the motor. The performance of the output filter is evaluated through simulations (PSIM) and experiment on PWM inverter-fed ac motor drive(3phase, 3hp(2.2kw), input voltage 220/380V, induction motor). An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board. Finally, experimental results showed that the inverter output filter reduces more CM noise than the LPF(low pass filter) and reduce overvoltage and ringing at the motor terminal.

  • PDF

Efficiency Enhancement of a Wireless Power Transmission System Applying a Superconducting Coil (초전도 코일을 적용한 무선전력전송 시스템 효율 향상)

  • Kang, Min-Sang;Choi, Hyo-Sang;Jeong, In-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.353-356
    • /
    • 2015
  • Due to high oil prices, environmental pollution, the study of electric vehicles have been actively promoted. Charger for the electric vehicle is being developed using wireless rather than cable options. In this paper, we got more efficiency from using a superconducting transmission coil compared to using a normal coil. We implemented a wireless power transmission system using a magnetic induction at a frequency of 63.1 kHz. For comparison, a transmitter was designed using a superconducting coil and a normal coil. In addition, a receiver used a normal coil to apply for electric vehicles. The applied voltage and current were12 V and 5 A. Efficiency at a distance of 40 ~ 80 mm was measured. As a result, the superconducting transmission coil had a higher efficiency than the normal transmission coil. However, the receiving coil should be normal conductor for stable operation considering that it was put in moving electric vehicle. The efficiency was increased to 44 % at a distance of 40 mm when the diameter of normal receiving coil was 120 mm.