• Title/Summary/Keyword: Cabin Space

Search Result 50, Processing Time 0.026 seconds

A Study on the flame behaviors of light railway vehicle (경량전철 차량화재의 화염거동에 대한 연구)

  • 목재균;김연수;이우동;허남건
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.281-289
    • /
    • 2002
  • This paper is described for the flame behaviors in light railway cabin by numerical simulation code, which can be interpreted the design parameters in terms of suppression the fire propagation and excavation the passengers safely. The results shows that the flame intensity(fire temperature, smoke density) depends on the firing points in cabin and propagates rapidly whole cabin space rather than modern subway cabin due to smaller inner space. The data will be used to how can be get the safety case, which is described on the operating principles for all facilities and logistics against to the light railway firing accidents.

  • PDF

Numerical Analysis on the Thermal Flow by a Thermoelectric Module within the Cabin of a Commercial Vehicle (상용차 캐빈 내의 열전모듈에 의한 열유동 수치해석)

  • Kim, J.K.;Oh, S.H.
    • Journal of Power System Engineering
    • /
    • v.16 no.5
    • /
    • pp.47-54
    • /
    • 2012
  • The steady three-dimensional numerical analysis on the thermal flow using standard k-${\varepsilon}$ turbulence model was carried out to investigate the air cooling effect of a cooler on the cabin for a commercial vehicle. Here, the heat exchanging method of this cabin cooler uses the cooling effect of a thermoelectric module. In consequence, the air system resistance of a cooler within the cabin is about 12.1 Pa as a static pressure, and then the operating point of a virtual cross-flow fan considering in this study is formed in the comparatively low flowrate region. The discharging air temperature of a cooler is about $14{\sim}15^{\circ}C$. Moreover, the air cooling temperature difference obtained under the outdoor cabin temperature of $40^{\circ}C$ shows about $7{\sim}9^{\circ}C$ in a driver resting space and about $9{\sim}14^{\circ}C$ in the front of a driver's seat including the space of a driver's foot.

A Study on Characteristics of Interior design materials in Leisure Boats & Yachts (레저보트${\cdot}$요트의 인테리어재료 특징에 관한 연구)

  • Byun Lyang-Soun
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.1 s.54
    • /
    • pp.158-165
    • /
    • 2006
  • The space of leisure boats & yachts is formed by interior design elements and shapes are formed by combination of those elements. By means of configuration of the design elements, space is made in a ship and patterns in an inside space are made through production. These space can be categorized as (1) cabin(common cabin, staterooms, one-cabin), (2) salon, (3) galleys & dinette, (4) heads(showers, toilets, bidets, sinks), (5) cockpit, (6) wheelhouses, navigation stations, (7) fore peaks, (8) engine room, (9) deck etc. Interior materials are classified into (1) walls(bulkheads & lining wall), (2) floors(sole), (3) ceilings(overheads), (4) doors & windows, (5) furniture, (6) lightings and (7) Hardware & decoration in large, medium and small sizes, which constitute interior design elements of a leisure boat & yacht. The materials used in leisure boats & yachts have properties of lightweight, noise and vibration resistance, fire & flame retardant, stability, strengths, lifespan, appearance and special operation in construction.

Exposure Assessment of Dust, Ultra Fine Dust(Particulate Matter 2.5, PM2.5) and Black Carbon among Aircraft Cabin Cleaners (항공기 기내 청소노동자의 분진, 초미세먼지(PM2.5) 및 블랙카본 노출수준 평가)

  • Hyunhee Park;Sedong Kim;Sungho Kim;Seung-Hyun Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.171-187
    • /
    • 2023
  • Objectives: Aircraft cabin cleaning work is characterized by being performed within a limited time in a narrow and enclosed space. The objective of this study was to evaluate the exposure levels to dust, ultra fine dust(PM2.5) and black carbon(BC) among aircraft cabin cleaners. Methods: Active personal air sampling for respirable dust(n=73) and BC(n=47) was conducted during quick transit cleaning(cabin general and vacuum-specific) and seat cover replacement and total dust and PM2.5 were area-air-sampled as well. Also, size distribution of particle was identified with the cleaning workers targeted. Dusts were collected with PVC filters using gravimetric analysis. The concentration of PM2.5 and the particle size distribution were measured with real-time direct reading portable equipment using light scattering analysis. The concentration of BC was measured by aethalometer(filter-based real-time light absorption analysis instrument). Results: The geometric mean of respirable dust was the highest at vacuum cleaning as 74.4 ㎍/m3, following by replacing seat covers as 49.3 ㎍/m3 and cabin general cleaning as 47.8 ㎍/m3 . The arithmetic mean of PM2.5 was 4.83 ~ 9.89 ㎍/m3 inside the cabin, and 28.5~44.5 ㎍/m3 outside the cabin(from bus and outdoor waiting space). From size distribution, PM2.5/PM10 ratio was 0.54 at quick transit cleaning and 0.41 at replacing seat covers. The average concentration of BC was 2~7 ㎍/m3, showing a high correlation with the PM2.5 concentration. Conclusions: The hazards concentration levels of aircraft cabin cleaners were very similar to those of roadside outdoor workers. As the main source of pollution is estimated to be diesel vehicles operating at airports, and it is necessary to replace older vehicles, strengthen pollutant emission control regulations, and introduce electric vehicles. In addition, it is necessary to provide as part of airport-inftastructure a stable standby waiting space for aircraft cabin cleaners and introduce a systematic safety and health management system for all workers in the aviation industry.

Design Verification of Cabin Pressurization System by Flight Test of T-50 Advanced Trainer (T-50 비행시험을 통한 조종실 여압시스템의 설계검증)

  • Seo, Dong-Yeon;Son, Won-Ik;O, Yeong-Jin;Kim, Ju-Hyeong;Park, Seong-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.11
    • /
    • pp.70-75
    • /
    • 2006
  • The cabin pressurization system response should be consistent with the design limits such as the cabin pressure schedule, the pressure regulation tolerance, the maximum rate of pressure change during normal and abnormal operation and the maximum cabin air inflow rate change. In this paper, the results of pressure loss analysis and flight test for cabin pressurization system of T-50 advanced trainer are introduced. The pressure tolerance at unpressurized condition using calculated exit area of pressurization components through pressure loss analysis is predicted. Pressurization components of D company are selected and the predicted pressure tolerance is in good agreement with flight test results. Finally, T-50 pressurization system is verified by some flight tests of T-50 advanced trainer to comply with various pressurization design criteria of MIL-E-18927.

Development of Amenity-oriented Air Cleaning System for Railroad Passenger Cabin (철도차량용 공기청정시스템 개발)

  • Park, Duck-Shin;Cho, Young-Min;Kwon, Soon-Bark;Park, Eun-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1288-1292
    • /
    • 2007
  • Because the indoor spaces of the passenger cabin is generally airtight to secure the safety of passengers and enhance the efficiency of the cabin air conditioning performances, the contamination pattern of them are largely similar to that of general indoor spaces. Therefore, continuous supply of outdoor air is required to keep the amenity of indoor space. Heating, ventilation, and air-conditioning (HVAC) system is composed of air cleaning filter, heater and air conditioned, blower and ducts. To achieve the clean indoor environment, an integrated control of each HVAC equipment are required. In this study, we developed the air cleaning system to enhance the amenity of the railroad passenger cabin.

  • PDF

Development of Amenity-Oriented Air Cleaning System for Railroad Passenger Cabin (객차용 청정시스템 개발)

  • Park, Duch-Shin;Cho, Young-Min;Kwon, Soon-Bark;Park, Eun-Young
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1234-1239
    • /
    • 2006
  • Because the indoors spaces of the passenger cabin is generally airtight to secure the safety of passengers and enhance the efficiency of the cabin air conditioning performances, the contamination pattern of them are largely similar to that of general indoor spaces. Therefore, continuous supply of outdoor air is required to keep the amenity of indoor space. Heating, ventilation, and air-conditioning (HVAC) system is composed of air cleaning filter, heater and air conditioned, blower and ducts. To achieve the clean indoor environment, an integrated control of each HVAC equipment are required. In this study, we developed the air cleaning system to enhance the amenity of the railroad passenger cabin.

  • PDF

A Study on Minimum Cabin Crew Requirements for Korean Low Cost Air Carriers

  • Yoo, Kyung-In;Kim, Mun-Kyung
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.33 no.2
    • /
    • pp.291-314
    • /
    • 2018
  • In recent 3 years, Korea's low-cost airlines have expanded their areas of passenger transportation not only to domestic market but also to Japan, China, Southeast Asia and US territory as a total of 6 companies (8 airlines including small air operation business carriers). Currently, three more airlines have filed for air transportation business certification as future low-cost carriers, and this expansion is expected to continue. To cope with the aggressive airline operations of domestic and foreign low-cost carriers and to enhance their competitiveness, each low-cost airline is taking a number of strategies for promoting cabin service. Therefore, the workload of the cabin crew is increased in proportion to the expansion, and the fatigue directly connected with the safety task performance is increased. It is stipulated in the Enforcement Regulations of the Korea Aviation Safety Act that at minimum, one cabin crew is required per 50 passenger seating capacity, and all low cost carriers are boarding only the minimum cabin crew. Sometimes it is impossible for them to sit in a floor level emergency exit for evacuation, which is the main task of the cabin crew, and this can cause confusion among evacuating passengers in the event of an emergency. In addition, if one of the minimum cabin crew becomes incapacitated due to an injury or the like, it will become a serious impediment in performing emergency evacuation duties. Even in the normal situation, since it will be violating the Act prescription on the minimum cabin crew complement, passengers will have to move to another available airline flights, encountering extreme inconvenience. Annex 6 to the Convention on International Civil Aviation specifies international standards for the determination of the minimum number of cabin crew shall be based only on the number of passenger seats or passengers on board for safe and expeditious emergency evacuation. Thereby in order to enhance the safety of the passengers and the crew on board, it is necessary to consider the cabin crew's fatigue that may occur in the various job characteristics (service, safety, security, first aid)and floor level emergency exit seating in calculating the minimum number of cabin crew. And it is also deemed necessary for the government's regulatory body to enhance the cabin safety for passengers and crew when determining the number of minimum cabin crew by reflecting the cabin crew's workload leading to their fatigue and unavailability to be seated in a floor level emergency exit on low cost carriers.

Multi-objective optimization design for the multi-bubble pressure cabin in BWB underwater glider

  • He, Yanru;Song, Baowei;Dong, Huachao
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.4
    • /
    • pp.439-449
    • /
    • 2018
  • In this paper, multi-objective optimization of a multi-bubble pressure cabin in the underwater glider with Blended-Wing-Body (BWB) is carried out using Kriging and the Non-dominated Sorting Genetic Algorithm (NSGA-II). Two objective functions are considered: buoyancy-weight ratio and internal volume. Multi-bubble pressure cabin has a strong compressive capacity, and makes full use of the fuselage space. Parametric modeling of the multi-bubble pressure cabin structure is automatic generated using UG secondary development. Finite Element Analysis (FEA) is employed to study the structural performance using the commercial software ANSYS. The weight of the primary structure is determined from the volume of the Finite Element Structure (FES). The stress limit is taken into account as the constraint condition. Finally, Technique for Ordering Preferences by Similarity to Ideal Solution (TOPSIS) method is used to find some trade-off optimum design points from all non-dominated optimum design points represented by the Pareto fronts. The best solution is compared with the initial design results to prove the efficiency and applicability of this optimization method.

A Study on Indoor Environment Performances of Power Yacht in Summer Season (여름철 파워요트 실내환경 성능에 관한 연구)

  • Lee, Han-Seok;Doe, Guen-Young;Lim, Duck-Min;Kim, Hak-Chul
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.175-180
    • /
    • 2009
  • In this study, the basic data were collected for improving the amenity of indoor environment of a super yacht and the performance of indoor environment was analyzed by utilizing measured data during summer period. Through the results of examination, the following conclusions are drawn. 1) It is estimated that, in case of closing the door of Saloon connected with outside, there is little inflow of exhaust gas, but when the door is open, the indoor-air might be polluted so fast. Therefore, it is necessary to make a counter plan about the method of ventilation and amount of ventilation to keep the indoor aerial environment agreeable. 2) It is urgent to conceive countermeasure against engine noise because the noise level of all rooms exceeds 60dB, which is regulation of noise for protecting crew established in ship's classification, during the sailing. 3) State cabin and Guest cabin are super cooled by operating air conditioner exceeding agreeableness extent and it is needed to prevent them.