• Title/Summary/Keyword: CV measurement

Search Result 175, Processing Time 0.026 seconds

Effects of Cornu Cervi Parvum Pharmacopuncture on the Blood Picture and Antioxidative Activity in Rats (녹용(Cornu cervi parvum)약침이 흰쥐의 혈액성상과 항산화능에 미치는 영향)

  • Lee, Kee-Byoung;Park, Sang-Kyun
    • Korean Journal of Acupuncture
    • /
    • v.27 no.2
    • /
    • pp.25-34
    • /
    • 2010
  • Objectives : To investigate the effects of Cornu cervi parvum pharmacopuncture with regard to the blood picture and antioxidative activity in rats. Methods : Sprague-Dawley rats were divided into 3 groups (n=5 each) and were treated with Cornu cervi parvum pharmacopuncture every other day for 2 weeks. The groups are classified as follows; normal control without treatment (control group), Cornu cervi parvum pharmacopuncture at CV4 (CV4 group), and Cornu cervi parvum pharmacopuncture at BL23 (BL23 group). Thereafter, the blood and liver samples were obtained for blood analysis and superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GSH-Px) activity measurement. Results : Cornu cervi parvum pharmacopuncture groups showed higher values of red blood cell count and plasma cell volume compared with those of the control (p<0.05). However, hemoglobin level showed no significant differences among groups. With regard to the blood picture, plasma concentration in total protein and albumin showed no significant differences in pharmacopuncture groups, while higher ratio of albumin/globulin was observed in CV4 group. White blood cell counts and its composition showed no significant differences among groups. Pharmacopuncture groups showed higher values in SOD, CAT, and GSH-Px activities compared with those of control group. Conclusions : Cornu cervi parvum pharmacopuncture alleviates oxidative activities in rats.

Paper-based Electrochemical Sensor Using a Self-operated Paper Pump (자발 구동형 종이 펌프를 이용한 종이 전기화학 센서)

  • Si Hiep Hua;Chikwan Kim;Duc Cuong Nguyen;Yong Shin Kim
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.158-164
    • /
    • 2024
  • We developed a self-operated paper pump that can maintain a nearly constant flow rate of an aqueous solution along a paper strip channel in paper-based analytical devices (PADs). The quasi-stationary flow rate was controlled by increasing the crosssectional channel area (capillary force) using a fan-shaped absorption pad coupled with a paper strip channel. The flow rate is regulated by varying the fan angle of the circular absorbing pad. Furthermore, the flow rate can be increased by furnishing a hollow cavity at the center of a conventional paper strip channel. The rate was regulated by varying the length of the hollow paper channel in the flow rate range of 5.1-26.4 mm/min. As a preliminary work, a paper-pump-coupled PAD was fabricated, and its CV detection capability was evaluated for the redox reaction of Fe(CN)6+4/+3. The combination of a paper pump with a PAD resulted in an ideal CV curve with a higher limiting current and faster response time. These results are interpreted well by the Levich equation, which suggests that the paper pump is a very useful component in paper-based sensors.

A Study of Surface Electromyography Measurement of Orbicularis oris motion in Healthy People (정상인의 구륜근 운동 시 표면근전도(SEMG) 측정연구)

  • Kim, Ju Yong;Kim, Bo Hyun;Kim, Hye Bin;Yook, Tae Han;Kim, Jong Uk
    • Journal of Acupuncture Research
    • /
    • v.33 no.4
    • /
    • pp.93-100
    • /
    • 2016
  • Objectives : To find an acupuncture point where more exact Surface Electromyography(SEMG) measurement can be drown, through the study of measurement of orbicularis oris. Methods : Of healthy people from 19 to 40 years of age, who did not fall under exclusion criteria (22 males and 22 females), were selected as subjects, after relaxation for 10 minutes, and they were told how to pronounce 'O' and 'U' with their lips puckered. The SEMG figures were measured with attaching disposable electrode on acupuncture point of right-and-left Hwaryo(LI19) and 1 cun away from Seungjang(CV24) on both sides when the subjects pronounced 'O' and 'U'. Results : The average value was highest on left 1 cun away from Seungjang(CV24) in pronouncing 'O' and 'U', and the average SEMG value was higher in the order of right 1 cun away from Seungjang(CV24), right Hwaryo(LI19), left Hwaryo(LI19). Average of the lower orbicularis oris is statistically higher than that of the upper orbicularis oris, which has significant meaning. However, there was no significant difference when compared by pronunciation. Average of percentage mark of differences of right-and-left measured value of each pronunciation and each acupuncture point : Pronounced 'O' and the upper part of orbicularis oris: $16.76{\pm}11.29%$, pronounced 'O' and the lower part of orbicularis oris: $22.41{\pm}12.92%$, pronounced 'U' and the upper part of orbicularis oris: $17.10{\pm}9.89%$, pronounced 'U' and the lower part of orbicularis oris : $19.20{\pm}10.82%$. Conclusion : The difference of pronunciation will not affect the results in SEMG measurement. In addition, the average of the lower orbicularis oris is statistically and significantly higher than that of the upper orbicularis oris.

Development of a 3D Semi-Automatic Measurement Protocol for Hand Anthropometric Measurement (손 치수 측정을 위한 3차원 반자동 측정 방법 개발)

  • Lee, Won-Sup;Yoon, Sung-Hye;You, Hee-Cheon
    • IE interfaces
    • /
    • v.24 no.2
    • /
    • pp.105-111
    • /
    • 2011
  • Measurement protocols for hand anthropometry have been studied for ergonomic product design. The present study developed a 3D semi-automatic measurement protocol (3D-SAMP) which semi-automatically measures various hand dimensions using a 3D scanner. The 3D-SAMP was compared with the conventional direct measurement method (DMM) to examine its effectiveness. The 3D-SAMP consists of (1) fabricating a plaster cast of the hand, (2) placing landmarks on the plaster hand, (3) scanning the plaster hand with a 3D scanner, (4) identifying automatically the positions of the landmarks on the digital hand, and (5) extracting automatically hand anthropometric measurements (lengths, widths, thicknesses, and circumferences). An evaluation experiment conducted in the study found the 3D-SAMP preferred to the DMM in terms of reliability (the number of dimensions exceeding the variability criteria SD=2 mm and CV=5% : 3D-SAMP =2 and DMM=24) and ease of measurement (3D-SAMP=5.2 and DMM=4.3 out of 7). The 3D-SAMP can be applied to ergonomic design of a hand-held product.

Analysis on the Impact of Load Factors in Building Energy Simulation Affecting Building Energy Consumption (에너지시뮬레이션에서의 부하요소가 건물에너지사용량에 미치는 영향 분석)

  • Yoon, Kap-Chun;Jeon, Jong-Ug;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.11 no.4
    • /
    • pp.71-78
    • /
    • 2011
  • The goal of this study is to analyze the impact of load factors on building energy consumption by using EnergyPlus program. We selected a campus building and monitored energy consumption from January 2009 to November 2010. First, we simulated energy consumption basically with weather data, building heat gain and EHP performance data. And then we simulated energy consumption with three additional parameter(infiltration, OA control and schedule). Simulation results are verified by MBE and Cv(RMSE) proposed by M&V guideline 3.0. Simulated total energy consumption was 104.3% of measurements, 4.33% of MBE, and 13.62% of Cv(RMSE). Results show infiltration and schedule were revealed as the most dominant factor of heating energy consumption and of cooling energy consumption, respectively.

Analysis of Stability on Single-leg Standing by Wearing a Head Mounted Display

  • Woo, Byung Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.2
    • /
    • pp.149-155
    • /
    • 2017
  • Objective: The purpose of this study was to investigate the effects of three visual conditions (eyes opened, eyes closed, and wearing of a head mounted display [HMD]) on single-leg standing through kinematics and kinetic analysis. Method: Twelve college students (age: $24.5{\pm}2.6years$, height: $175.0{\pm}6.4cm$, weight: $69.2{\pm}5.1kg$) participated in this study. The study method adopted three-dimensional analysis with six cameras and ground reaction force measurement with one force plate. The analysis variables were coefficient of variation (CV) of the center of body mass, head movement, ground reaction force, and center of pressure, which were analyzed using one-way analysis of variance with repeated measures according to visual conditions. Results: In most cases, the results of this study showed that the CV was significantly higher in the order of HMD wearing, eyes closed, and eyes opened conditions. Conclusion: Our results indicated that body sway was the largest in the HMD wearing condition, and the risk of falling was high owing to the low stability.

The Effect of Moxibustion at Jeonjung($CV_{17}$) on the Heart Rate Variability in Healthy Adults (膻中穴($CV_{17}$) 간접구요법이 정상 성인의 심박변이도(HRV)에 미치는 영향)

  • Lee, Jeong-Ju;Kim, Seong-Joung;Park, Ok-Ju;Lee, Sang-Mi;Park, Min-Cheol;Jo, Eun-Heui
    • Journal of Acupuncture Research
    • /
    • v.29 no.4
    • /
    • pp.43-53
    • /
    • 2012
  • Objectives : This study was accomplished to investigate the effects of moxibustion at Jeonjung($CV_{17}$) on the heart rate variability(HRV) in healthy adults. And based on that, we tried to find out how moxibustion at Jeonjung($CV_{17}$) effects on the activity and balance of the autonomic nervous system Methods : We investigated on 50 healthy volunteers consisted of 24 subjects in moxibustion group and 24 subjects in control group. On the other hand, two volunteers were ruled out by standard of elimination. The study was established by randomized trial. Moxibustion was applied at Jeonjung($CV_{17}$) and rested during 10 minutes in moxibustion group. No treatment was executed in control group. We measured HRV 3 times : baseline measurement and after treatment in moxibustion group(after rest in control group) twice. The SPSS 12.0 for windows was used to analyze the data by paired t-test, Wilcoxon signed ranks test(in group) and Independent t-test, Mann-Whitney U-test (between the groups). Results : 1. In moxibustion group, mean HRT decreased significantly. Ln(VLF) increased significantly. Ln(TP) decreased significantly at $2^{nd}$ time and increased significantly at $3^{rd}$ time. SDNN, RMSSD, PSI, Ln(LF), Ln(HF), Normalized LF, Normalized HF and LF/HF ratio were not affected. 2. In control group, PSI and normalized HF decreased significantly. SDNN, Ln(TP), Ln(VLF), normalized LF and LF/HF ratio increased significantly. Mean HRT, RMSSD, Ln(LF) and Ln(HF) were not affected. Conclusions : This study suggest that moxibustion at Jeonjung($CV_{17}$) makes no effects on the balance of the autonomic nervous system.

A Study of Correlation between Pulse-Respiration Ratio and Characteristics of Thermal Temperature (체표온도특성(體表溫度特性)과 맥율(脈率)의 상관성(相關性) 연구(硏究))

  • Lee, Hyuk-Jae;Park, Young-Jae;Park, Young-Bae;Oh, Hwan-Sup
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.103-130
    • /
    • 2008
  • Background: For standardizing of Han-Yeol [寒熱], which is a kind of diagnosis method in oriental medicine, it is necessary to investigate into relationship of symptoms and signs representative of Han-Yeol [寒熱] to the biofunctional medical signals; thermal temperature by Thermography, Pulse-Respiration Ratio and so on. By correlation analysis of these data items acquired from patients, it could be provides the fundamental data for standardizing of Han-Yeol [寒熱]. Objectives: We performed this study to check the characteristics of thermal temperature with Han-Yeol [寒熱] statue by pulse-respiration ratio. Methods: We selected nine regions around acupoints including Yin dang[印堂], Sugu[水溝, GV26], Ch'ondol[天突, CV22], Chonjung[CV17], Chung-wan[中脘, CV12], Chonchu[天樞 S25], No-gung[勞官, P8], and calculated based on the utility of R.O.I.(Region of Integer) by IR-2000 these points temperature from 68 subjects. In practicing pulse-respiration ratio over 4.0 means the statues of Yeol [熱], pulse-respiration ratio below 4.0 means the statues of Han [寒]. To optimum conditions thermal temperature, which are not effected by internal and external variables, we studied preceding research. The results shows that optimal time period is 20minutes after undressed and the optimal region is the region around acupoints including Sugu [水溝, GV26]. Based on a preceding research results, we analyzed these data by Paired T-test between GV26 Region and 8-Thermography Regions and two-way repeated ANOVA with thermography$({\Delta}T)$ and Han-Yeol [寒熱] statue by pulse-respiration ratio. Results: 1. In applying of two-way repeated ANOVA with thermography$({\Delta}T)$ and Han-Yeol [寒熱] statue by pulse-respiration ratio, Sugu [水溝穴, GV26] - [印堂穴, HN1], Sugu 水溝, GV26] - Chonjung[CV17], Sugu [水溝, GV26] -Chung-wan[中脘, CV12]had significant differences. 2. In applying of Paired T-test between Sugu [水溝穴, GV26] Region and 8- Thermography Regions, there were significant differences except of Sugu [水溝穴, GV26] -Chondolp[天突, CV22]. 3. In the difference of Sugu [水溝, GV26] -Chung-wan[中脘, CV12], thermal temperature increases a lot in the statues of Yeol [熱], thermal temperature decreases a lot in the statues of Han [寒]. Conclusions: On the analysis of Thermography, we obtain the measurement conditions were considered the individual variations. And it is different that the thermal temperature change on Thermography according to Han-Yeol [寒熱] statue by pulse-respiration ratio.

  • PDF

The Effect of Venesection with Cupping Therapy at Jeonjung($CV_{17}$) on the Heart Rate Variability in Healthy Adults (전중혈(膻中穴)($CV_{17}$) 습부항요법이 정상 성인의 심박변이도(HRV)에 미치는 영향)

  • Kim, Seong Joung;Park, Jin Soo;Lee, Jeong Ju;Park, Ok Ju;Kim, Sul Gi;Jeong, Ho Hyun;Park, Min Cheol;Kwon, Young Mi;Jo, Eun Heui
    • Journal of Acupuncture Research
    • /
    • v.30 no.4
    • /
    • pp.15-24
    • /
    • 2013
  • Objectives : This study was accomplished to investigate the effects of venesection with cupping therapy at Jeonjung($CV_{17}$) on the heart rate variability(HRV) in healthy adults. And based on that, we tried to find out how venesection with cupping therapy at Jeonjung($CV_{17}$) affects the activity and the balance of the autonomic nervous system. Methods : We investigated on 60 healthy volunteers consisted of 30 subjects in venesection with cupping therapy group and 30 subjects in control group. The study was established by randomized trial. venesection with cupping therapy was applied at Jeonjung($CV_{17}$) for 10 minutes in venesection with cupping therapy group. No treatment was executed in control group. We measured HRV 3 times : First, baseline measurement and two more times after treatment in venesection with cupping therapy group(after rest in control group). The SPSS 12.0 for Windows was used to analyze the data by paired t-test(in both group), independent-test(between the groups) and Chi-square test(between the sexs). Results : 1. In venesection with cupping therapy group, SDNN, Ln(TP), Ln(LF), Normalized LF, and LF/HF ratio increased significantly. Normalized HF decreased significantly. Mean HRT, RMSSD, PSI, Ln(HF), and Ln(VLF) were not affected. 2. In control group, Ln(HF) decreased significantly. Mean HRT, SDNN, RMSSD, PSI, Ln(TP), Ln(LF), Ln(VLF), Normalized LF, Normalized HF, and LF/HF ratio were not affected. Conclusions : This study suggests that venesection with cupping therapy at Jeonjung($CV_{17}$) increases the activity of the autonomic nervous system and has effects on the balance of the autonomic nervous system.

Characterization of Leather Skin Layer Coatings on Water Dispersed Polyurethane Applied with Eathyl Acetate and Piperazine (Eathyl acetate와 Piperazine이 적용된 수분산 폴리우레탄의 Skin layer 코팅에 따른 특성 연구)

  • Lee, Joo-Youb
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.1235-1242
    • /
    • 2019
  • In this study, prepolymer was synthesized through the reaction of isoporon diisocyanate (IPDI) and dimethylolbutanoic acid (DMBA) based on poly (tetramethylene ether) glycol (PTMG) for the synthesis of water-soluble polyurethane to be used as a leather surface coating applied with ethyl acetate and piperazine. Thereafter, the piperazine was chain-extended with 0.01 M, 0.03 M, 0.05 M, and 0.07 M in the water-dispersed resin, and the tensile strength, elongation, CV (cyclic voltammetry), and solvent resistance analysis were performed. Tensile strength of the prepared sample was measured at 5.422 kgf/㎟ when the piperazine content was 0.07M, and elongation was measured as 587% when the piperazine was 0.01M. Solvent resistance analysis showed the same solvent resistance regardless of piperazine content, and the redox potential was changed according to piperazine content through CV measurement.