• Title/Summary/Keyword: CV Cable

Search Result 63, Processing Time 0.028 seconds

APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUATION (열화 진단 평가를 위한 직류 누설법의 활용)

  • Lee, Kwan-Woo;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables' aging test method

  • PDF

APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUAT10N (열화 진단 평가를 위한 직류 누설법의 활용)

  • 이관우;박대희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables'aging test method.

  • PDF

Residual Insulation characteristics of long-term serviced 6.6 kV CV Cable (6.6kV 철거 CV 케이블의 잔존 절연 특성)

  • 백주흠;김동욱;한기만
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.46-49
    • /
    • 1994
  • In order to investigate possibility of CV cable diagnosis technique, residual insulation characteristics of .long - term serviced 0.6 kV CV Cable are examined by DC leakage current residual voltage tensile strength, cross1inking density and AC & impulse breakdown. Also effect of cable structure and water tree are reported

  • PDF

AC Breakdown Characteristics for 22.9kV CV Power Cable Before and After Cyclic Aging for 14days (22.9kV CV 전력케이블의 14주기 고온 열화에 대한 교류파괴특성)

  • 윤대혁;김위영;박민호;박태곤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.601-604
    • /
    • 2001
  • 22.9 kV CV power cable is very important factor of underground distribution power line. Cyclic aging for 14days is performed to remove a large amount of the volatiles found in freshly manufactured cable. In this paper, we examined AC breakdown characteristics of CV power cable before and after cyclic aging for 14days. As the result, even if there were some exceptions, the AC breakdown voltage before aging was lower than that after aging, but most of the results were that the AC breakdown voltage after aging was lower than that before aging.

  • PDF

Normalization Diagnosis of Aging Process on Partial Discharge Signals of CV Cable (CV케이블의 부분방전 신호를 통한 열화과정의 정량적 진단)

  • 소순열;임장섭;김진사;이준웅;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.451-455
    • /
    • 1997
  • The partial discharge has been blown as the chief breakdown of power equipments. The analysis and the recognition is much difficult because the partial discharge signal is very small and has complex aging pattern. Recently, insulation aging diagnosis based on pattern of phase(Ф), partial discharge magnitude(q), number(n) has been very important. Owing to depreciate the reappearance of aging progress at the electrical tree pattern and to be difficult to analyze visually, the study on partial discharge pattern is suggested to normalizing analysis method of partial discharge signals. This parer is purposed on prediction of life-time measurement of cv-cable, on decision of risk degree with normalization and real-time measurement of partial discharge signals for aging diagnosis of cv-cable. As normalizing the aging signals of electrical tree in cv-cable, it is able to confirm risk degree of insulation material with the distribution of Ф-q-n and recognize the process of aging pattern using neural network.

  • PDF

A Study on the Results of the diagnosis of Insulation Deterioration in Live-Line Distribution Power Cables at the Field (배전용 CV케이블의 현장 열화진단 결과의 고찰)

  • Yoo, Soung-Jong;Jeon, Seung-Ik;Jung, Suk-Youn
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1831-1834
    • /
    • 1996
  • Diagnosis of cable insulation degradation has important meaning from a viewpoint of reliability enhancement of CV cable systems. So, we diagnosed 3.3kV & 6.6kV CV distribution cable on live-line which is judged to a most poor installation condition because they have been used in water condition after installation at the Yeochon chemical complex. The paper describes the analysis of the measured data, the problems at diagnosis, and the items which are considered at the development of diagnosis technology and equipment hearafter.

  • PDF

A Study on the Remain Life with Aging in 22kV CV cable (22kV 전력케이블의 열화 판정에 관한 연구)

  • Lee, Kwan-Woo;Mok, Young-Soo;Kim, Bo-Kyeong;Park, Bok-Ki;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.19-21
    • /
    • 2003
  • In this paper, we studied on life-decision of underground cable of live-lines state. As all equipments have been wear, underground cables decided design-life on the whole 30 years because underground cable have been occurred aging as time goes. CV cable has been become about 30 years after installation in the South Korea, is come to a important point of time with estimation about life. Study target cable is 22 kV CV cables in this point of view and installation cable is about 10 years before and behind. Measurement method used dc leakage method of live-lines state that applied voltage of 50V in neutral point and data is analyzing result that is measured during 5 years. In this result, insulation resistance could confirm that change according to season and cause is effect of humidity, seasons and load current. Also, according as data is gone aging, insulation resistance by Weibull distribution could confirm functionally its decrease. As a result, the aging speed of cable that water tree is gone could confirm fastness very. Numerical analysis result, cable that water tree is not gone could confirm that life of cable that has passed 10 years remains about $10{\sim}20$ years.

  • PDF

Determination of Proto Type for 345kV CV Cable Accessories (345kV CV 케이블 접속함의 Proto Type 선정)

  • Lee, S.K.;Kim, I.T.;Son, S.H.;Choi, S.G.;Huh, G.D.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1629-1631
    • /
    • 1998
  • Crosslinked polyethylene (XLPE) insulated cables are now widely used all over the world for extra-high voltage underground transmission systems. Prefabricated type (compression type) joint has developed in order to shorten the assembly time and lower the possibility of contamination at site by many companies in the world. For outdoor termination, to control the electric field distribution as uniform as possible, especially for the use of extra-high voltage system. much of products are adopting the oil-impregnated condensor cone type instead of electric field control element which uses the permitivity of it only (not capacitance). For Gas-immersed termination, dimension of outer insulation bushing was determined by IEC Publication 859. The highest voltage of underground power cable system is 345kV now, in Korea. We have much of experiences of the development of prefabricated type accessories for CV cable systems (154kV, 161kV, 230kV level). So it was possible to inspect the proto type of accessories for 345kV CV cable system and seems that the need time for the development of products is reduced.

  • PDF

Effect of the Capacitance for 600V CV Cable Applying Outdoor Electricity Facilities (옥외전기시설물에 사용되는 600V CV케이블 정전용량의 영향)

  • Lee, H.G.;Ha, T.H.;Bae, J.H.;Him, D.K.;Kim, S.W.;Lee, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.323-325
    • /
    • 2002
  • Because of the progress of civilization, outdoor electricity facilities as a street light, signal light and standing signboard etc. have being increased rapidly. Therefore the application of underground distributing wires is largely expended. In this paper, capacitance for the kinds of 600V CV cable is measured and leakage current for underground cable is calculated. The measurement of capacitance is done which there are defects of cable sheath or not Calculated leakage current is applied to choose the circuit breaker and the like.

  • PDF