• Title/Summary/Keyword: CTS Test

Search Result 61, Processing Time 0.02 seconds

High-Speed Wind Tunnel Test on Rocket Booster Separation (로켓 부스터 분리 고속 풍동시험)

  • Ra, Seung-Ho;Kim, In-Sun;Ok, Ho-Nam;Oh, Bum-Seok;Lee, Joon-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.10
    • /
    • pp.75-81
    • /
    • 2005
  • Jettison, grid and CTS test are widely used for the store and stage separation studies. This is an introductory paper on the experimental methodology and typical results of grid and CTS test used for the Korean 3-stage sounding rocket development. Thirteen separation trajectories were evaluated in the ONERA S2MA wind tunnel at Mach numbers of 2.0 and 2.8. The test result was applied as the basic database for the design of optimized separation device.

CTS: A Cluster System Test Suite for Preventive Maintenance (CTS: 예방 정비를 위한 클러스터 시스템 검사 도구)

  • 차광호
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.10 no.5
    • /
    • pp.385-393
    • /
    • 2004
  • Cluster systems have been widely used for solving problems in various application domains, and regarded as useful high performance computing resources. As the number of cluster system user is increasing, it is no less important to maintain stable operation than to improve cluster system performance. Although hardware preventive maintenance is important for keeping normal operation, the testing tool which can be used for general cluster systems during maintenance has received little attention. In this Paper, considering hardware Preventive maintenance, we suggest a testing tool for hardware of cluster system. The cluster system testing tool which is named CTS(Cluster system Test Suite) has two check routines; one for memory, and the other for NIC respectively. The CTS is designed to support the common features of general cluster systems and all the Jobs such as setting test conditions to querying the results can be done entirely within an integrated GUI environment. CTS is used as the testing tool for two kinds of cluster systems during maintenance, and the experimental results show that CTS reports useful information for cluster systems management.

Pre-layout Clock Analysis with Static Timing Analysis Algorithm to Optimize Clock Tree Synthesis (Static Timing Analysis (STA) 기법을 이용한 Clock Tree Synthesis (CTS) 최적화에 관한 연구)

  • Park, Joo-Hyun;Ryu, Seong-Min;Jang, Myung-Soo;Choi, Sea-Hawon;Choi, Kyu-Myung;Cho, Jun-Dong;Kong, Jeong-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.391-393
    • /
    • 2004
  • For performance and stability of a synchronized system, we need an efficient Clock Tree Synthesis(CTS) methodology to design clock distribution networks. In a system-on-a-chip(SOC) design environment, CTS effectively distributes clock signals from clock sources to synchronized points on layout design. In this paper, we suggest the pre-layout analysis of the clock network including gated clock, multiple clock, and test mode CTS optimization. This analysis can help to avoid design failure with potential CTS problems from logic designers and supply layout constraints so as to get an optimal clock distribution network. Our new design flow including pre-layout CTS analysis and structural violation checking also contributes to reduce design time significantly.

  • PDF

The Communication Satellite Transponder Testing by EGSE System

  • Jo, Jin-Ho;Woo, Hyung-Je;Lee, Seong-Pal
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.36-40
    • /
    • 2007
  • EGSE is used to check out satellite payload during the development prior to launch. The EGSE represented in this paper is a test system for Ka band communication transponder of COMS. The EGSE consist of two subsystems as CTS subsystem and PCTS subsystem. Communication Test subsystem (CTS) performs satellite transponder RF performance testing, data analysis and trending. Most of transponder RF performances are automatically tested by the CTS subsystem. Power, Command & Telemetry subsystem (PCTS) monitor telemetry messages from the transponder and send tele-commands to satellite transponder for the configuration change. PCTS also provide simulated S/C power to the transponder during the ground validation testing. The EGSE test functions are verified by the transponder simulator testing and will be used for the flight model transponders testing.

  • PDF

The Diagnostic Assessment of Hand Elevation Test in Carpal Tunnel Syndrome

  • Ma, HyunJin;Kim, Insoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.5
    • /
    • pp.472-475
    • /
    • 2012
  • Objective : The aim of this study is to establish the value of hand elevation test as a reproducible provocative test for the diagnosis of carpal tunnel syndrome (CTS). Methods : We had a prospective study of 45 hands of 38 patients diagnosed with CTS between April 2005 and February 2009. The diagnosis of CTS was based on the American Academy of Neurology clinical diagnostic criteria. Experimental and control group patients underwent Tinel's test, Phalen's test, carpal compression test and hand elevation test as provocative tests for CTS. Results : We used chi-square analysis to compare Tinel's test and Phalen's test, carpal compression test with hand elevation test. The sensitivity and specificity of the hand elevation test is 86.7% and 88.9% each. Tinel's test had 82.2% sensitivity and 88.9% specificity. Phalen's test had 84.4% sensitivity and 86.7% specificity. Carpal compression test had 84.4% sensitivity 82.2% specificity. Comparisons of sensitivity and specificity between hand elevation test and Tinel's test, Phalen's test, and carpal compression test had no statistically significant differences. To compare the diagnostic accuracies of four tests, the area under the non-parametric receiver operating character curve was applied. Conclusion : The hand elevation test has higher sensitivity and specificity than Tinel's test, Phalen's test, and carpal compression test. Chi-square statistical analysis confirms the hand elevation test is not ineffective campared with Tinel's test, Phalen's test, and carpal compression test.

Extension of Absolute Evaluation Technique for Ratio Error and Phase Displacement of Core Type Current Transformers: Ip =$5\;kA{\sim}40\;kA$ (철심형 전류변성기의 비오차 및 위상오차 절대 평가 기술의 확장 : 1차 전류 = $5\;kA{\sim}40\;kA$)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.431-436
    • /
    • 2008
  • We have extended an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) up to primary current of 40,000 A by measuring four parameters of equivalent circuit in CT. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 5 A - 40,000 A / 5 A. The ratio error and phase displacement of the CTs under test obtained in this study are consistent with those measured at the national institutes in Canada and Germany using the same CTs under test within an expanded uncertainty (k = 2) in the overall current ratios.

Carthamus tinctorius seeds-Taraxacum coreanum combination attenuates scopolamine-induced memory deficit through regulation of inflammatory response and cholinergic function

  • Mei Tong He;Yu-Su Shin;Hyun Young Kim;Eun Ju Cho
    • Nutrition Research and Practice
    • /
    • v.18 no.5
    • /
    • pp.647-662
    • /
    • 2024
  • BACKGROUND/OBJECTIVES: There is growing interest in herbal medicines for managing age-related diseases, such as Alzheimer's and Parkinson's. Safflower seeds (Carthamus tinctorius L. seeds, CTS) and dandelions (Taraxacum coreanum, TC) are widely used to treat bone- or inflammation-related diseases in Oriental countries. This study investigated the protective effect of the CTS-TC combination on scopolamine (Sco)-induced memory deficits through inflammatory response and cholinergic function. Moreover, marker components such as serotonin, N-(p-coumaroyl) serotonin, N-feruloylserotonin, chlorogenic acid, and chicoric acid in the CTS-TC combination were analyzed for their potential benefits on memory function. MATERIALS/METHODS: Water extracts of CTS, TC, and the CTS-TC combination at various ratios (4:1, 1:1, and 1:4) (100 mg/kg) were orally administered to mice for 14 days. Sco (1 mg/kg) was intraperitoneally injected into the mice before each behavioral test. T-maze and novel object recognition tests were conducted to monitor behavioral changes after the treatment. Western blotting was performed to detect protein expression. In addition, the presence of 5 biomarkers, serotonin, N-(p-coumaroyl) serotonin, N-feruloylserotonin, chlorogenic acid, and chicoric acid, was analyzed using high-performance liquid chromatography (HPLC). RESULTS: Behavioral tests showed that the CTS-TC combination enhanced memory function in Sco-injected mice. Inflammation-related proteins (inducible nitric oxide synthase, cyclooxygenase-2, and glial fibrillary acidic protein) were downregulated after treatment with the CTS-TC combination. The acetylcholinesterase protein expression was also downregulated. HPLC analysis revealed that N-feruloylserotonin and chicoric acid were the predominant components, followed by N-(p-coumaroyl) serotonin, chlorogenic acid, and serotonin. CONCLUSION: These findings suggest that the CTS-TC combination protects against Sco-induced memory deficits by inhibiting inflammatory responses and cholinergic dysfunction. N-feruloylserotonin and chicoric acid, along with N-(p-coumaroyl) serotonin, chlorogenic acid, and serotonin, might be biomarkers for the CTS-TC combination, and their effects on memory protection warrant further study.

Transfer of RP4:Mu cts from E. coli to Rhizovium leguminosarum (RP4:Mu cts의 E.coli로 부터 Rhizovium leguminosarum으로의 전달)

  • 이인렬;허연주;이영록
    • Korean Journal of Microbiology
    • /
    • v.23 no.2
    • /
    • pp.107-114
    • /
    • 1985
  • In order to use for recipient strains of RP4:Mu cts, 5 strainsof Rhizobium were selected among 32 strains, which were isolated and identified in this study. Hybrid plasmin RP4::Mu cts, which, is temperature sensitive and confers resistance to ampicillin, kanamycin and tetracycline was transfered by conjugation from E. coli to other atrains of C. coli and the symbiotic nitrogen fixer, Rhizobium leguminosarum. Transfer frequencies of RP4::Mu cts plasmid from E. coli to Rhizobium were about $10^{-8}-10^{-7}$ in LB agar and YMA media. The transconjugants were confirmed by demonstrating that the drug-resistant and temperature-sensitive clones isolated were drug-resistant and temperature-sensitive clones isolated were capable of releasing phage and forming plaques. The plaque-forming units of transconjugants were about $10^2\;to\;10^3$. Stability test of RP4::Mucts in Rhizobium represented that most of the transconjugants had drug resistance and produce phage Mu cts.

  • PDF

Evaluation of Thermography in the Diagnosis of Carpal Tunnel Syndrome : Comparative Study between Patient and Control Groups

  • Hong, Yong-Pyo;Ryu, Kyeong-Sik;Cho, Byung-Moon;Oh, Sae-Moon;Park, Se-Hyuck
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.6
    • /
    • pp.423-426
    • /
    • 2006
  • Objective : There is still debate about the diagnostic efficacy of digital infrared thermographic imaging[DITI], nevertheless, it has been used for the diagnosis of carpal tunnel syndrome[CTS]. We performed comparative study between patient and control groups to investigate the diagnostic value of DITI in CTS. Methods : We studied 27 patients with electrodiagnostically-proven CTS and 18 symptom-free volunteers as a control. We measured thermal difference on DITI in the corresponding regions of the hands and forearms. We statistically analyzed the thermal data using a t-test. Results : The average thermal difference in the diagnosed patient group ranged from $0.0303^{\circ}C$ to $0.2856^{\circ}C$, while that in control group ranged from $0.0611^{\circ}C$ to $0.2878^{\circ}C$. In the CTS patient group, thermal difference between each 2nd finger was higher than that of other regions. However, there was no statistical significance between patient and control groups. Conclusion : We found that the diagnostic value of DITI in CTS was not sufficient. There should be a reconsideration of the usefulness of DITI in CTS.

Research on flexural bearing capacity of cold-formed thin-walled steel and reinforced concrete sandwich composite slabs

  • Qiao, Wentao;Huang, Zhiyuan;Yan, Xiaoshuo;Wang, Dong;Meng, Lijun
    • Steel and Composite Structures
    • /
    • v.45 no.2
    • /
    • pp.219-230
    • /
    • 2022
  • The aim of this paper is to study the mechanical behaviors of the cold-formed thin-walled steel and reinforced concrete sandwich composite slab (CTS&RC-SCS) under vertical loads and to develop the calculation methods of its flexural bearing capacity and section stiffness. Two CTS&RC-SCS specimens were designed and manufactured to carry out the static loading test, and meanwhile, the numerical simulation analyses based on finite element method were implemented. The comparison between experimental results and numerical analysis results shows that the CTS&RC-SCS has good flexural capacity and ductility, and the accuracy and rationality of the numerical simulation analysis are verified. Further, the variable parameter analysis results indicate that neither increasing the concrete strength grade nor increasing the thickness of C-sections can significantly improve the flexural capacity of CTS&RC-SCS. With the increase of the ratio of longitudinal bars and the thickness of the composite slab, the flexural capacity of CTS&RC-SCS will be significantly increased. On the basis of experimental research and numerical analysis above, the calculation formula of the flexural capacity of CTS&RC-SCS was deduced according to the plastic section design theory, and section stiffness calculation formula was proposed according to the theory of transformed section. In terms of the ultimate flexural capacity and mid-span deflection, the calculated values based on the formulas and the experimental values are in good agreement.