• 제목/요약/키워드: CT99

검색결과 346건 처리시간 0.027초

The Usefulness of Bolus of Radiation Therapy in Patients with Whole Breast Cancer

  • Min, Jung-Whan;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.99-103
    • /
    • 2011
  • Radiation Therapy has been used in the treatment of breast cancer for over 80 years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internam mammary nodes and supraclavicular nodes. The purpose of this study is treated breast cancer patient to use 6 MV, 10 MV with bolus so that we observe changing of skin dose and evaluate those usefulness. Using woman's phantom, after CT simulate scanning, Through RTP system to make treatment plan, select three any place. And then, we measure that dose rate. After moving the phantom to linac, we put for TLD to three point same as RTP system which we put on the phantom. We exposed 6 MV, 10 MV with bolus and without so that it is measured dose by TLD device(4000 Harshaw). As a reult expose 6 MV,10 MV, it differences 10%, 15% according to bolus and withoout bolus where lateral point from RAO, LPO beam, other one is 20% where the furthest from both beams. To use bolus in the hospital is material to include closely part at skin among tissue of breast cancer. Acquired skin dose from RTP system is uncertainity. So it has to test another system likely TLD or other dosimetry system. Also exposed field of breast cancer is included inhomogeneity such as lung, bone and so on. Therefore it has to be accomplished a dose calculating of inhomogeneity part from treatment plan.

  • PDF

Zipeprol 남용환자에서 뇌 단일광자방출 전산화단층촬영술의 임상적 의의 (Clinical Significance of Brain SPECT in Zipeprol Abusers)

  • 조대옥;김재필;김덕윤;양형인;고은미;김광원;최영길
    • 대한핵의학회지
    • /
    • 제27권1호
    • /
    • pp.22-27
    • /
    • 1993
  • Drug abuse is widespread in worldwide and has been associated with neurologic complication. Zipeprol is one of the drugs which been abused for psychological satisfaction in some adolescents. This agent is non-opioid antitussive agent, which is not legally considered as being capable of creating dependence or abuse liability at therapeutic serum levels. But it has been reported that acute or chronic overdose create neurologic complication such as convulsion as well as dependence. Recently we experienced six zipeprol abusers who admitted due to convulsion and variable neurologic symptoms. The aim of our study was to determine the role of $^{99m}Tc$-HMPAO brain SPECT in those patients. EEG and brain CT showed no abnormal finding, but brain SPECT showed focal or multiple perfusion abnormalities in frontal, parietal, occipital cortex, basal ganglia, thalamus and especially at temporal cortex. These results suggest that brain SPECT may be a useful diagnostic tool to evaluate the cerebral dysfunction infused by zipeprol abuse.

  • PDF

청색증으로 내원한 간폐증후군 1예 (A Case of Hepatopumonary Syndrome with Cyanosis)

  • 류대식;정복현;정상식;김호동;유철희;강길현;김남현;정승문;박만수
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권3호
    • /
    • pp.420-425
    • /
    • 1999
  • 저자들은 심한 청색증을 동반한 만성 간질환에서, 폐 내 동정맥 단락과 동맥혈 저산 소혈증을 보인 간폐증 후군 1예를 경험하였기에 문헌고찰과 함께 보고한다. 단순흉부 X-선 사진에는 망상결절이 하엽 기저부에 주로 분포하였고 고해상 전산화 단층영상에서 확장된 폐혈관이 늑막까지 연장되어 보이고, 특히 비정상적으로 증가된 폐혈관종말지의 확장이 늑막하 폐에 분포하였다. 핵의학 관류검사 및 조영 심초음파 검사를 통해 폐내 단락을 진단하여 보고하는 바이다.

  • PDF

3D 프린팅 팬텀의 섬광카메라 적용 평가 (Evaluation of Scintillation Camera Applications of 3D Printing Phantom)

  • 박훈희;이주영;김지현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.343-350
    • /
    • 2021
  • 3D printing technology is an additive manufacturing technology produced through 3D scanning or modeling method. This technology can be produced in a short time without mold, which has recently been applied in earnest in various fields. In the medical field, 3D printing technology is used in various fields of radiology and radiation therapy, but related research is insufficient in the field of nuclear medicine. In this study, we compare the characteristics of traditional nuclear medicine phantom with 3D printing technology and evaluate its applicability in clinical trials. We manufactured the same size phantom of poly methyl meta acrylate(PMMA) and acrylonitrile butadiene styrene(ABS) based on the aluminum step wedge. We used BrightView XCT(Philips Health Care, Cleveland, USA) SPECT/CT. We acquired 60 min list mode for Aluminum, PMMA and ABS phantoms using Rectangular Flood Phantom (Biodex, New York, USA) 99mTcO4 3 mCi(111 MBq), 6 mCi (222MBq) and 57Co Flood phantom(adq, New Hampshire, USA). For the analysis of acquired images, the region of interest(ROI) were drawn and evaluated step by step for each phantom. Depending on the type of radioisotope and radiation dose, the counts of the ABS phantom was similar to that of the PMMA phantom. And as the step thickness increased, the counts decreased linearly. When comparing the linear attenuation coefficient of Aluminum, PMMA and ABS phantom, the linear attenuation coefficient of the aluminium phantom was higher than that of the others, and the PMMA and ABS phantom had similar the linear attenuation coefficient. Based on ABS phantom manufactured by 3D printing technology, as the thickness of the PMMA phantom increased, the counts and linear attenuation coefficient decreased linearly. It has been confirmed that ABS phantom is applicable in the clinical field of nuclear medicine. If the calibration factor is applied through further research, it is believed that practical application will be possible.

Sensitivity and uncertainty quantification of neutronic integral data in the TRIGA Mark II research reactor

  • Makhloul, M.;Boukhal, H.;Chakir, E.;El Bardouni, T.;Lahdour, M.;Kaddour, M.;Ahmed, Abdulaziz;Arectout, A.;El Yaakoubi, H.
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.523-531
    • /
    • 2022
  • In order to study the sensitivity and the uncertainty of the Moroccan research reactor TRIGA Mark II, a model of this reactor has been developed in our ERSN laboratory for use with the N-Particle MCNP Monte Carlo transport codes (version 6). In this article, the sensitivities of the effective multiplication factor of this reactor are evaluated using the ENDF/B-VII.0, ENDF/B-VII.1 and JENDL-4.0 libraries and in 44 energy groups, for the cross sections of the fuel (U-235 and U-238) and the moderator (H-1 and O-16). However, the quantification of the uncertainty of the nuclear data is performed using the nuclear code NJOY99 for the generation and processing of covariance matrices. On the one hand, the highest uncertainty deviations, calculated using the ENDFB-VII.1 and JENDL4.0 evaluations, are 2275, 386 and 330 pcm respectively for the reactions U235(n, f), $ U_{235}(n\bar{\nu})$ and H1(n, γ). On the other hand, these differences are very small for the neutron reactions of O-16 and U-238. Regarding the neutron spectra, in CT-mid plane, they are very close for the three evaluations (ENDF/B-VII.0, ENDF/B-VII.1 and JENDL-4.0). These spectra present two peaks (thermal and fission) around the energies 0.05 eV and 1 MeV.

코로나-19 무증상 감염 환자의 한약 치료 방안에 대한 고찰 (A review on the treatment of Herbal Medicine for asymptomatically infected COVID-19 patients)

  • 정선형;이경은;정민정;송미덕;장인수
    • 대한한의학회지
    • /
    • 제42권1호
    • /
    • pp.99-109
    • /
    • 2021
  • Objectives: Objective: The purpose of this study is to investigate the treatment of herbal medicine for patients with COVID-19 asymptomatic infections. Method: In English, search engines such as 'PubMed', 'Science Direct', and 'Cumulative Index to Nursing and Allied Health Literature (CINAHL)' were used. In Chinese, search engines such as 'China National Knowledge Infrastructure (CNKI)' and Wanfang were used. The keywords for the search engines were 'COVID-19', 'asymptomatic infection', 'Korean Medicine', 'traditional Chinese medicine', 'herbal medicine', and etc. Only clinical studies using herbal medicine for patients without fever or respiratory symptoms were selected. We excluded the cases that do not fit the research topic. Results: A total of 5 studies were finally selected. Among them, four of them used integrated herbal medicine and Western medicine, and one of the studies treated exclusively for herbal medicine. There were a total of seven prescriptions for herbal medicine used in the study. Outcome variables were used as following: lab test, nucleic acid conversion time, hospitalization period, chest CT, and etc. In the RCT study, herbal medicine and Western medicine decreased nucleic acid conversion time, average hospitalization time compared to the control group, but it was not statistically significant. No other adverse reactions were reported in all studies. Conclusion: According to the results, integrated herbal medicine and Western medicine might be an effective treatment for patients with COVID-19 asymptomatic infection reducing hospitalization period, time of nucleic acid turning negative. No severe adverse effects were reported. However, it is thought that better-designed research will be needed in the future.

조기 암 진단을 위한 $^{18}F$-FDG Fusion PET의 유용성 (Usefulness of $^{18}F$-FDG Fusion PET for Diagnosing an Early Stage Cancer)

  • 전재환;김병진;이홍재;김진의;김현주
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.145-149
    • /
    • 2010
  • 최근 수 년 동안 암 진단의 예민도가 우수한 $^{18}F$-FDG Fusion PET이 건강검진 목적으로 적용되어 왔다. 건강검진에서 $^{18}F$-FDG Fusion PET의 시행 유 무가 조기 암 발견에 유용한지를 규명하기 위하여 건강검진센터에서의 18F-FDG Fusion PET 검사 유 무에 따른 진단율을 비교하였다. 2004년 2월부터 2008년 12월까지 건강검진을 목적으로 서울대학교병원 강남센터를 내원하여 $^{18}F$-FDG Fusion PET을 시행한 2790명을 대상으로 하였다. 피검자에게 $^{18}F$-FDG 5.18 MBq/kg (0.14 mCi/kg)을 투여한 후 1시간이 경과되면 두개골 기저부터 대퇴부까지 영상을 획득하였다. PET scanner는 PHILIPS사의 GEMINI GS를 사용하였다. 서울대학교병원 강남검진센터에서 PET 시행 유 무가 조기 암 진단율에 영향을 주는지에 대하여 분석하였다. 상기 기간 동안 서울대학교병원 강남센터에서 건강검진을 진행한 피검자 중 $^{18}F$-FDG Fusion PET 검사를 시행하지 않은 집단과 시행한 집단은 각각 99,009명과 2,790명이었다. 건강검진에서 PET 검사가 제외된 집단과 시행된 집단의 악성종양 진단율은 각각 0.95%, 1.94%로 나타났다. PET 검사에서 비정상 소견을 보인 사람은 542명이었으며, 이 중 악성 및 양성종양은 각각 10%, 90%로 판명되었다. 악성종양의 종류 및 비율은 갑상선암 31.5%, 폐암 14.8%, 위암 9.3%, 직장암 3.7%, 유방암 3.7%, 전이암 16.7% 등으로 나타났다. 또한 양성 소견으로는 종격동 림프절의 비 특이적인 섭취, 대장의 생리적인 섭취, 갑상선의 미만성 섭취 증가 등이 있었다. 검진 목적으로 시행한 $^{18}F$-FDG Fusion PET의 악성종양 진단율은 일반적인 검진보다 상대적으로 높았다. 결론적으로 건강검진에서 $^{18}F$-FDG Fusion PET을 시행하는 것은 조기 암 진단에 우수하며 유용하다고 사료된다.

  • PDF

조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가 (Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques)

  • 남지호;기용간;김동원;김원택
    • Radiation Oncology Journal
    • /
    • 제25권1호
    • /
    • pp.26-33
    • /
    • 2007
  • 목 적: 좌측 조기유방암으로 보존수술 후 2차원 또는 3차원 모의치료를 통해 방사선치료를 받은 환자들에서 SPECT (single photon emitted computerized tomography) 영상을 이용하여 심근관류결손의 부위와 빈도를 비교 평가하고자 하였다. 대상 및 방법: 2002년 1월부터 2003년 8월까지 AJCC 병기 T1-T2N0M0인 좌측 조기유방암으로 진단되어 외과에서 보존수술 및 화학요법 후 방사선치료를 시행하였던 32명의 환자들을 대상으로 하였다. X선 투시기를 이용한 2차원 모의치료를 통해 방사선치료를 받은 환자들과 컴퓨터단층촬영 기반의 3차원 모의치료 방법을 이용했던 환자들을 구분하여 연구를 진행하였다. 이들을 대상으로 최소 3년 이상의 추적관찰 기간 후에 technetium-99m-sestamibi gated perfusion SPECT를 시행하여 각 군에서의 심근관류결손의 부위와 빈도를 비교 평가하였고, 각 환자들에서의 심벽의 운동상태와 좌심실의 박출량을 측정하여 분석하였다. 또한 모의치료 과정에서 방사선에 피폭되는 심장영역을 각 군에서 측정하여 심근관류결손과의 상관관계를 알아보았다. 결 과: SPECT 영상 결과, 심근관류결손이 확인된 경우는 전체 32명의 환자 중 11명(34.4%)이었다. 2차원 모의치료를 받은 15명의 환자 중 7명(46.7%)에서, 3차원 모의치료를 받은 17명의 환자 중 4명(23.5%)에서 관류결손이 발견되었는데, 3차원 모의치료를 이용한 환자들에서 심근관류결손의 빈도가 통계적으로 유의하게 낮았다(p=0.0312). 심근관류결손이 확인된 11명 중, 심첨부 결손을 보인 경우가 10명으로 대부분을 차지했다. 심벽의 운동상태와 심실박출량은 모두 정상이었으며, 방사선 조사야에 포함된 심장영역은 3차원 모의치료 군에서 보다 작았으나 양군에서의 심근관류결손과의 통계적 유의성은 확인할 수 없었다. 결 론: 저자들은 이번 연구를 통해 좌측 조기유방암 환자에서 보존수술 후 방사선치료 시 전산화단층촬영 모의치료기를 이용한 3차원 모의치료 방법을 이용하면 심근에 대한 조사용적을 줄일 수 있어 심근관류결손의 빈도를 낮출 수 있음을 확인하였다. 그러나 심근관류스캔상의 결손과 향후 임상적인 허혈성 심장질환으로의 발전 또는 이로 인한 사망률의 증가와의 연관성은 장기간의 추적관찰과 전향적 임상연구를 통해 확인할 필요가 있겠다.

KCl을 사용한 LiNi0.6Co0.2Mn0.2O2계 양극활물질의 잔류리튬 저감 및 전기화학특성 개선 (Improved Electrochemical Performance and Minimized Residual Li on LiNi0.6Co0.2Mn0.2O2 Active Material Using KCl)

  • 유기원;신미라;신태명;홍태환;김홍경
    • 전기화학회지
    • /
    • 제20권1호
    • /
    • pp.7-12
    • /
    • 2017
  • $LiNi_{0.6}Co_{0.2}Mn_{0.2}O_2$의 전구체 물질에 KCl을 첨가함으로써, 리튬카보네이트($Li_2CO_3$)와 리튬수산화물(LiOH)의 양을 감소시켰을 때 전기화학특성에 어떤 영향을 주는지에 대한 연구를 진행하였다. KCl을 1 질량 %로 전구체에 첨가하여 $800^{\circ}C$에서 열처리 한 샘플의 경우, 첨가하지 않은 재료와 대비하여 잔류하는 리튬카보네이트($Li_2CO_3$)는 8,464 ppm에서 1,639 ppm으로 리튬수산화물(LiOH)은 8,088 ppm에서 6,287 ppm으로 크게 감소하였다. XRD 분석결과 KCl의 첨가는 모상구조에 영향을 주지 않았으며, 층상구조 결정성이 약간 개선되는 효과가 확인되었다. 또한, 전하전달 저항($R_{ct}$)은 $255{\Omega}$에서 KCl 첨가 시 $99{\Omega}$으로 감소하였다. 초기 방전 용량은 171.04 mAh/g에서 182.73 mAh/g으로 증가하였으며 싸이클 특성도 개선되었다. 특히, AFM 분석을 통하여 표면적이 50% 감소하는 것을 확인하였는데, 이는 잔류리튬의 산화반응으로 인한 열 때문일 것으로 해석되고, 전해질과의 부반응을 억제할 수 있는 장점이 있었다. 잔류리튬 제거를 위해 KCl을 첨가한 연구는, 아직까지 발표된 바가 없으며, $LiNi_{0.6}Co_{0.2}Mn_{0.2}O_2$계 양극활물질의 전기화학특성을 개선하는데 매우 효과적임을 본 연구를 통해 확인할 수 있었다.

흥부 전산화단층촬영을 이용한 한국성인의 기관내경과 단면적의 측정 (CT Measurement of Diameter and Dimension of the Trachea in Normal Korean Adults)

  • 한재열;김광호;이건;김형진;조순구;선경
    • Journal of Chest Surgery
    • /
    • 제34권7호
    • /
    • pp.534-538
    • /
    • 2001
  • 배경: 기관의 크기와 기관주위의 정상형태에 대한 지식은 임상에서 기도나 호흡관리, 그리고 기관재건술을 시행하는데 중요한 정보가 된다. 흉부 단순촬영은 기관의 직경을 재는 간단한 방법이지만 그 상이 확대되는 경향과 측면촬영에서 어깨와 상이 겹쳐서 나타나는 단점이 있다. 이에 저자들은 한국인 정상 성인의 기관의 정상치를 알기 위해 흥부 전산화 단층촬영을 이용하여 기관의 내경과 단면적을 측정하였다. 대상 및 방법: 남자 43명과 여자34명을 대상으로 하여 각각 나이에 따라 20~39세는 제 1군, 40~59세는 제2군, 60세 이상은 제 3군으로 구분하였다. 흉부 유입구와(Level 1) 대동맥궁에서(Level 2) 흉부 전산화 단층촬영을 이용하여 각각 전후경과 횡경을 재고 그 단면적을 구하였다. 결과: level 1에서 한국인 성인 남자의 기관의 전후경은 15.95$\pm$2.99 m, 횡경은 17.72$\pm$2.13 m이었고, 여자의 경우 전후경은 15.56$\pm$2.12 m, 횡경은 14.18$\pm$2.07mm로 남녀간에 유의한 차이가 있었다(p 0.05). Level 2에서 남자의 전후경은 19.77$\pm$2.57 m, 횡경은 18.02$\pm$2.19 mm이었고 여자의 전후경은 15.35$\pm$1.82 m, 횡경은 15.00$\pm$1.60 mm로 남녀간에 유의한 차이가 있었다 (p 0.05). 기관단면적은 남자가 각 Level에서 279.14$\pm$61.37 $\textrm{mm}^2$(Level 1), 281.93$\pm$63.97 $\textrm{mm}^2$(level 2)였고, 여자가 173.29$\pm$35.81 $\textrm{mm}^2$(Level 1), 181.88$\pm$34.74 $\textrm{mm}^2$(Level 2)로 두 위치에서 단면적은 남녀간에 유의한 차이가 있었다(p 0.05). 기관의 각각의 위치에서 내경과 단면적은 연령군에 따라 고연령층에서 증가하는 추세를 나타내었으나 통계적인 의미는 없었다. 결론: 한국 정상 성인의 기관내경과 단면적의 크기는 성별에 따라 통계적으로 유의한 차이가 있었으나 연령에 따른 차이는 없었고, 전산화 단층촬영은 기관의 내경과 단면적의 크기를 얻는데 비교적 정확하고 안전한 방법이라 생각된다.

  • PDF