Patient Position Verification and Corrective Evaluation Using Cone Beam Computed Tomography (CBCT) in Intensity.modulated Radiation Therapy (세기조절방사선치료 시 콘빔CT (CBCT)를 이용한 환자자세 검증 및 보정평가)

  • Do, Gyeong-Min;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: Cone beam computed tomography (CBCT) using an on board imager (OBI) can check the movement and setup error in patient position and target volume by comparing with the image of computer simulation treatment in real.time during patient treatment. Thus, this study purposed to check the change and movement of patient position and target volume using CBCT in IMRT and calculate difference from the treatment plan, and then to correct the position using an automated match system and to test the accuracy of position correction using an electronic portal imaging device (EPID) and examine the usefulness of CBCT in IMRT and the accuracy of the automatic match system. Materials and Methods: The subjects of this study were 3 head and neck patients and 1 pelvis patient sampled from IMRT patients treated in our hospital. In order to investigate the movement of treatment position and resultant displacement of irradiated volume, we took CBCT using OBI mounted on the linear accelerator. Before each IMRT treatment, we took CBCT and checked difference from the treatment plan by coordinate by comparing it with the image of CT simulation. Then, we made correction through the automatic match system of 3D/3D match to match the treatment plan, and verified and evaluated using electronic portal imaging device. Results: When CBCT was compared with the image of CT simulation before treatment, the average difference by coordinate in the head and neck was 0.99 mm vertically, 1.14 mm longitudinally, 4.91 mm laterally, and 1.07o in the rotational direction, showing somewhat insignificant differences by part. In testing after correction, when the image from the electronic portal imaging device was compared with DRR image, it was found that correction had been made accurately with error less than 0.5 mm. Conclusion: By comparing a CBCT image before treatment with a 3D image reconstructed into a volume instead of a 2D image for the patient's setup error and change in the position of the organs and the target, we could measure and correct the change of position and target volume and treat more accurately, and could calculate and compare the errors. The results of this study show that CBCT was useful to deliver accurate treatment according to the treatment plan and to increase the reproducibility of repeated treatment, and satisfactory results were obtained. Accuracy enhanced through CBCT is highly required in IMRT, in which the shape of the target volume is complex and the change of dose distribution is radical. In addition, further research is required on the criteria for match focus by treatment site and treatment purpose.

  • PDF

Morphological Analysis of the Mental Foramen and Anterior Loop of the Mandibular Canal using Computed Tomography (전산화단층촬영 방사선영상을 이용한 이공과 하악관 전방고리의 형태학적 분석)

  • Kim, Yong-Gun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.317-326
    • /
    • 2011
  • The mental foramen and anterior loop of the mandibular canal are important landmarks for mandibular surgical procedures. The purpose of this study was to analyze the shape and position of the mental foramen and anterior loop of the mandibular canal on the computed tomography (CT) images, and apply the results clinically. CT images of 96 patients (33 male, 36 female, age range 17~43 years, mean $24.6{\pm}4.99$ years) were enrolled. The horizontal and vertical position of the mental foramen, as well as the distance from the root apices were measured. The distance of the anterior loop of the mandibular canal to the root apices, and the buccal angle were measured. The mental foramen was found mostly below the second premolar observed in 81 cases (46.0%), between the first and second premolars in 67 cases (38.0%), and between the second premolar and first molar in 19 cases (10.2%). The mean distance between the mental foramen and the lower border of the mandible was $12.20{\pm}1.77$ mm, the mean distance between the mental foramen and root apex was $5.16{\pm}0.98$ mm. The mean distance of the anterior loop of the mandibular canal was $5.80{\pm}2.00$ mm. The buccal angle measured at $47.7{\pm}9.07^{\circ}$. The distance between the root apex and mental foramen measured as $5.16{\pm}0.98$ mm on panoramic radiography, and $6.2{\pm}3.07$ mm on CT. The mean distance between the mental foramen and mandibular canal was $5.39{\pm}1.62$ mm. When performing surgical procedures such as installing dental implants, it is important to minimize surgical trauma, especially the risk of damage to the mental nerve. To optimize the surgical outcome, a careful assessment of the shape and position of the mental foramen and the anterior loop of the mandibular canal must be made. CT images are useful for finding such anatomic structures.

Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT (심근관류 SPECT에서 가역적인 병변을 보인 환자의 3차원 심장 SPECT/CTA 퓨전영상의 유용성)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Kang, Won-Jun;Kim, Seong-Min;Won, Kyoung-Sook;Lim, Seok-Tae;Hwang, Kyung-Hoon;Lee, Byeong-Il;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.513-518
    • /
    • 2009
  • Purpose: Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Materials and Methods: Forty-eight patients (M:F=26:22, Age: $63.3{\pm}10.4$ years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Results: Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Conclusion: Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

Usefulness of wearing pocket dosimeter in nuclear medicine (핵의학 영상검사에서 Pocket dosimeter 착용의 유용성 평가)

  • Kim, Young-Bin;Lee, Eun-Ji;Kim, Kun-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.25-28
    • /
    • 2011
  • Purpose: The aim of study is to find accuracy of pocket dosimeter in measuring exposed dose in compared with survey meter and to compare exposed dose according as Nuclear medicine exams. Materials and Method: First, radiation dose to point source(185 MBq,370 MBq, ${\ldots}$, 1665 MBq, 1850 MBq) were measured in using a pocket dosimeter and a survey meter. Second, radiation dose to 12 patients injected $^{18}F$-FDG 370 MBq were measured in using a pocket dosimeter and a survey meter. Third, radiation dose to 10 patients injected $^{99m}Tc$-DPD 925 MBq were measured in using a pocket dosimeter and a surveymeter. Result: The average is $70.12{\pm}39.36{\mu}Sv/h$ in measurement of point source with Surveymeter and $5{\pm}3.06{\mu}Sv$ in measurement of point source with Pocket dosimeter. The average is $25.04{\pm}6.16{\mu}Sv/h$ in measurement of PET/CT patients with Surveymeter and $2.41{\pm}0.51{\mu}Sv$ in measurement of PET/CT with Pocket dosimeter. The average is $8.58{\pm}0.96{\mu}Sv/h$ in measurement of Bone Scan patients with Surveymeter and $1{\mu}Sv$ in measurement of Bone Scan patients with Pocket dosimeter. Significant difference found between Survey meter value and Pocket dosimeter value in all experimentation (p<0.001). Conclusion: Accoring to rusult Wearing Pocket dosimeter is usefulnee in manerage of exposed dose in nucler medicine exams.

  • PDF

Evaluation of Neoadjuvant Chemotherapy Effect in Osteosarcoma (골육종에서 술전 항암화학요법의 효과 판정)

  • Joo, Min Wook;Kang, Yong-Koo;Yoo, Ie Ryung;Choi, Woo Hee;Chung, Yang-Guk;Kim, Dong-Hyun;Kang, Jin-Woo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.20 no.2
    • /
    • pp.66-73
    • /
    • 2014
  • Purpose: Various diagnostic imaging modalities have been used to evaluate the effect of neoadjuvant chemotherapy for osteosarcoma early and noninvasively. We evaluated the effectiveness of imaging studies of plain radiographs and positron-emission tomography/computed tomography (PET/CT) in predicting neoadjuvant chemotherapy effect for osteosarcoma and tried to establish a general principle in interpretation of PET/CT parameters. Materials and Methods: Eighteen patients who underwent two cycles of neoadjuvant chemotherapy and surgical excision for osteosarcoma were enrolled. There were 13 males and 5 females, with a median age of 19 (11-63) years. Fifteen patients of 18 had the American Joint Committe on Cancer (AJCC) stage IIB. They had plain radiographs and PET/CT before and after neoadjuvant chemotherapy. The resected tumor specimens were pathologically examined to determine histological response grade using a conventional mapping method. Statistical analysis was performed to evaluate the correlation between histopathological necrosis rate, and radiographic finding category, post-chemotherapy maximum standardized uptake value (SUVmax), average standardized uptake value and metabolic tumor volume (MTV) as well as reduction rates of them. Results: Eight patients were good responders to neoadjuvant chemotherapy based on histological evaluation. Median SUVmax reduction rate was 73 (23-77) % in good responders and 42 (-32-76) % in poor responders. Median MTV reduction rate was 93.5 (62-99) % in good responders and 46 (-81-100) % in poor responders. While radiographic finding category was not different according to histological response (p=1.0), SUVmax reduction rate was significantly different (p=0.041). Difference in MTV reduction rates approached statistical significance as well (p=0.071). Conclusion: While radiographic finding category was not reliable to assess neoadjuvant chemotherapy effect for osteosarcoma, reduction rate of SUVmax was a useful indicator in this study. As parameters of PET/CT can be influenced by various factors of settings, different centers have to make an effort to establish their own standard of judgement with reference of previous studies.

Diffuse Infiltrative Lung Disease : Comparison of Diagnostic Accuracies of High-Resolution CT and Radiography (미만성 침윤성 폐질환의 진단: HRCT와 단순흉부X선사진의 비교)

  • Kim, Kyeong-Ah;Kang, Eun-Young;Oh, Yu-Whan;Kim, Jeung-Sook;Park, Jai-Soung;Lee, Kyung-Soo;Kang, Kyung-Ho;Chung, Kyoo-Byung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.388-402
    • /
    • 1996
  • Background : To compare the diagnostic accuracies of High-resolution CT(HRCI) and chest radiography in the diagnosis of diffuse infiltrative lung disease(DILD). Methods : This study included ninety-nine patients with a diagnosis of acute or chronic DILD, representing 20 different diseases. Twelve normal subjects were included as control. The disease state was confirmed either pathologically or clinically. Radiographs and CT scans were evaluated separately by three independent observers without knowledge of clinical and pathologic results. The observers listed three most likely diagnoses and recorded degree of confidence. Results : The sensitivity of HRCT in the detection of DILD was 98.9% compared to 97.9% of chest radiography. Overall, a correct first-choice diagnosis was made in 48% using chest radiographs and in 60% using HRCT images. The correct diagnosis was among the top-three choices in 64% when chest radiographs were used, and in 75% when HRCT images were reviewed. Overally a confident diagnosis was reached more often with HRCT(55%) than with chest radiography(26%). The correct first-choice diagnosis increased remarkably when the HRCT was used in usual interstitial pneumonia, miliary tuberculosis, diffuse panbronchiolitis and lymphangitic carcinomatosis. Conclusion : HRCT is confirmed to be superior to conventional radiography in the detection and accurate diagnosis of DILD. HRCT is especially valuable in the diagnosis of usual interstitial pneumonia, miliary tuberculosis, diffuse panbronchiolitis, and lymphangitic carcinomatosis.

  • PDF

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.

Clinical Characteristics and Comparison of the Various Methods Used for the Diagnosis of the New Influenza A Pandemic in Korea (한국에서의 2009 신종 인플루엔자 A의 임상양상과 다양한 진단 방법들의 비교)

  • Kwon, Min Jung;Lee, Chang Kyu;Roh, Kyoung Ho;Nam, Myung Hyun;Yoon, Soo Young;Lim, Chae Seung;Cho, Yun Jung;Kim, Young Kee;Lee, Kap No
    • Laboratory Medicine Online
    • /
    • v.1 no.1
    • /
    • pp.26-34
    • /
    • 2011
  • Background: Laboratory diagnosis of new influenza A (H1N1) is crucial for managing patients and establishing control and prevention measures. We compared the diagnostic accuracies of the real time RT-PCR (rRT-PCR) test recommended for the confirmation of the new flu and the viral culture method used conventionally for viral disease with that of the rapid antigen test (RAT). Methods: We performed RAT, R-mix culture, and real-time PCR by using 861 respiratory samples collected from December 2009 to January 2010 and evaluated the abilities of these methods to detect new influenza A. The relationship among the positive rates of RAT, grades of culture, and the cycle threshold (Ct) values of rRT-PCR was also evaluated. Results: Of the 861 patients, 308 (35.8%) were diagnosed with new influenza A. The sensitivities, specificities, positive predictive values, and negative predictive values of the tests were respectively as follows: 59.7%, 99.5%, 98.4%, and 81.6% for RAT; 93.2%, 100%, 100%, and 96.3% for R-mix culture; and 95.8%, 100%, 100%, and 97.7% for rRT-PCR. Samples with weak positive grade in culture and those with Ct values of 30-37 in rRT-PCR showed positivities as low as 25.3% and 2.3% in RAT, respectively. The hospitalization rate and death rate of the confirmed patients were 3.2% and 0.3%, respectively, and gastrointestinal symptoms were observed in 7.2% of the patients. Conclusions: R-mix culture and rRT-PCR tests showed excellent reliability in the diagnosis of new influenza A and could be very useful, especially for samples with low viral load.

Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy (Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가)

  • Lee, Hun Hee;Kim, Chan Kyu;Song, Kwan Soo;Bang, Mun Kyun;Kang, Dong Yun;Sin, Dong Ho;Lee, Du Heon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose : In this study, we evaluated the usefulness of colloid gel(slime) as a compensator for irregular patient surfaces in radiation therapy. Materials and Methods : For this study, colloid gel suitable for treatment was made and four experiments were conducted to evaluate the applicability of radiation therapy. Trilogy(Varian) and CT(SOMATOM, Siemens) were used as treatment equipment and CT equipment. First, the homogeneity according to the composition of colloid gel was measured using EBT3 Film(RIT). Second, the Hounsfield Unit(HU) value of colloid gel was measured and confirmed by CRIS phantom, Eclipse RTP(Eclipse 13.1, Varian) and CT. Third, to measure the deformation and degeneration of colloid gel during the treatment period, it was measured 3 times daily for 2 weeks using an ion chamber(PTW-30013, PTW). The fourth experiment was compared the treatment plan and measured dose distributions using bolus, rice, colloid gel and additional, dose profiles in an environment similar to actual treatment using our own acrylic phantom. Result : First experiment, density of the colloid gel cases 1, 2 and 3 was $1.02g/cm^3$, $0.99g/cm^3$ and $0.96g/cm^3$. When the homogeneity was measured at 6 MV and 9 MeV, case 1 was more homogeneous than the other cases, as 1.55 and 1.98. In the second experiment, the HU values of case 1, 2, 3 were 15 and when the treatment plan was compared with the measured doses, the difference was within 1 % at all 9, 12 MeV and a difference of -1.53 % and -1.56 % within the whole 2 % at 6 MV. In the third experiment, the dose change of colloid gel was measured to be about 1 % for 2 weeks. In the fourth experiment, the dose difference between the treatment plan and EBT3 film was similar for both colloid gel and bolus, rice at 6 MV. But colloid gel showed less dose difference than bolus and rice at 9 MeV. Also, dose profile of colloid gel showed a more uniform dose distribution than the bolus and rice. Conclusion : In this study, the density of colloid gel prepared for radiation therapy was $1.02g/cm^3$ similar to the density of water, and alteration or deformation was not observed during the radiotherapy process. Although we pay attention to the density when manufacturing colloid gel, it is sufficient in that it can deliver the dose uniformly through the compensation of the patient's body surface more than the bolus and rice, and can be manufactured at low cost. Further studies and studies for clinical applications are expected to be applicable to radiation therapy.

  • PDF

Contrast-Enhanced Magnetic Resonance Angiography for Evaluation of the Steno-occlusive Disease of the Supraaortic Arteries: Comparison with Computed Tomography Angiography and Digital Subtraction Angiography (조영증강 자기공명 혈관조영술을 이용한 대동맥궁 위 혈관의 협착 및 페쇄 질환 평가: 전산화 단층 혈관조영술 및 디지털 감산혈관조영술과의 비교)

  • Jeh, Su-Kyung;Kim, Bum-Soo;Jung, So-Lyung;Ahn, Kook-Jin;Shin, Yong-Sam;Lee, Kwan-Sung;Kim, Young-In;Lee, Kwang-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.152-160
    • /
    • 2009
  • Purpose : To intra-individually compare diagnostic accuracy of high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with computed tomography angiography (CTA) and digital subtraction angiography (DSA) for the assessment of supraaortic steno-occlusive disease. Materials and Methods : Twenty-eight patients (20 men, 8 women, 53-79 years of age) underwent supraaortic CE-MRA, CTA and DSA. CE-MRA was performed on two 1.5T MR scanners (voxel dimension: $0.66{\times}0.66{\times}1.1$ or $1.2\;mm^3$), and CTA on 64-slice CT scanners (voxel dimension: $0.42{\times}0.42{\times}0.63\;mm^3$). All the three examinations were completed within 40 days (median 19 days; range 1-40 days). Retrospective evaluation and measurement of diameter of 6 extracranial and 9 intracranial arterial segments was done by 2 experienced radiologists. Results: A total of 420 arterial segments were examined by CE-MRA, CTA and DSA. On DSA, 34 stenoocclusive lesions were noted at extracranial (n= 19) and intracranial (n = 15) vessels. For extracranial stenosis greater than 70%, sensitivity, specificity, positive predictive value (PPV) and negative predictive values (NPV) were 94.7%, 98.7%, 90.0% and 99.3% on CE-MRA, and 94.7%, 99.3%, 94.7% and 99.3% on CTA. For intracranial stenosis greater than 50%, sensitivity; specificity, PPV and NPV were 93.3%, 98.3%, 77.8%and 99.6% on CE-MRA, and 86.7%, 97.9%, 72.2% and 99.1 % on CTA, with DSA as the standard of reference. Conclusion : Supraaortic CE-MRA is as reliable as CTA in depicting the arterial stenosis, and is effective in screening of significant stenosis of both extracranial and intracranial arterial stenosis.