• Title/Summary/Keyword: CT99

Search Result 346, Processing Time 0.028 seconds

Adenocarcinoma of the parotid gland with calcification (석회화를 수반한 이하선내 선양암종)

  • Song Haeng-Eun;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.55-59
    • /
    • 2002
  • A 78-year-old woman was referred to Chonbuk National University Dental Hospital complaining of facial palsy and palpable mass on the right parotid gland area. Clinical examination showed non-specific findings of the intraoral region, but showed asymmetrical facial appearance. Panoramic view showed a large amorphous calcified mass on the posterior to the mandibular ramus and thin cortical plate of the posterior ramus. Sialogram showed constriction of the main duct and no further filling of striated, intercalated ducts and parenchymal areas. CT scans demonstrated an irregular, infiltrating mass with slight enhancement in the right parotid gland. The mass showed necrotic areas and calcifications. Bone scan showed marked accumulation of /sup 99m/Tc-MDP on the right posterior maxilla. Microscopic findings demonstrated the minimal morphologic alterations and rare mitotic figures within tumor cells, and diagnosed as adenocarcinoma (NOS, Grade II). This report could be aid in the diagnosis of calcified lesions of the salivary gland.

  • PDF

Consideration of Imaging Studies for Degenerative Spine Disease (퇴행성 요추질환 영상의 고찰)

  • Sin, Jung-Sub;Kim, Jae-Hun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.1
    • /
    • pp.93-99
    • /
    • 2007
  • Purpose : The aim of this study is to consider degenerative spine disease theoretically and compare plain radiography which is a basic study for low back pain with MRI in cases of degenerative lumbar spine disease to find out whether the abnormalities agree with each other. Methods : In 4 cases of lumbar degenerative disease, we studied the relation of the abnormalities such as disc space narrowing, spinal space narrowing, loss of lordosis and osteophytes on plain radiography with those on MRI of HIVD, spinal stenosis and spondylolisthesis. Results : Many abnormalities such as disc space narrowing, spinal space narrowing, loss of lordosis, osteophytes and change of cortex & bone marrow on plain radiography suggest HIVD, spinal stenosis, spondylolysis or spondylolisthesis on MRI. Conclusion : For low back pain patients, plain radiography is a basic study in diagnosis of HIVD, spinal stenosis, spondylolysis or spondylolisthesis but MRI or CT scan is necessary to develop(build) a treatment plan like an operation.

  • PDF

Development and Application of Web-Based Shopping Systems Configuration Model for the Activation of Electronic Commerce: Concerning both the Business and Technical Issues (전자상거래 확산을 위한 웹기반 쇼핑시스템의 상황모형의 개발 및 적용: 경영과 기술의 조화로운 연구관점)

  • Kim, Chang-Su
    • International Commerce and Information Review
    • /
    • v.6 no.3
    • /
    • pp.81-99
    • /
    • 2004
  • Research relevant to the electronic commerce tends to either overestimate or underrate the role of Information and Communication Technology (lCT). There is both technological skepticism within the social science circles and technical optimism within the engineering and computing field. Each perspective seems to have a limitation in adequately explaining the phenomenon of electronic commerce diffusion. Therefore, this research attempts to explore major characteristics of Web-based shopping systems as enablers of new business, concerning both the technical and business aspects in contemporary electronic commerce settings. On this basis, this paper addresses a configuration model of WBSS on the harmonious perspective concerning both the technical and business issues. It is our hope that both technical perspective and business perspective for exploring WBSS's configuration model presented in this paper can be an initial step towards a more balanced debate of ICT role, for electronic commerce.

  • PDF

A Study on the Fatigue Crack Growth Behavior of Cr-Mo- Steel for Pressure Vessel (압력용기용 Cr-Mo강의 균열진전거동에 관한 연구)

  • Choe, Byeong-Ik;Lee, Hak-Ju;Han, Seung-U;Kim, Chang-Uk;Cha, Jeong-Hwan;Kim, Jeong-Tae;Ji, Byeong-Ha
    • 연구논문집
    • /
    • s.29
    • /
    • pp.91-99
    • /
    • 1999
  • Fatigue crack growth behaviors of Cr-Mo steels developed recently for thick-wall pressure vessel were investigated. Experiments in accordance with ASTM E647 standard were performed for 1/2 inch CT specimens of $2^(1/4)$Cr-1Mo and 3Cr-IMo steels in gaseous environments, hydrogen gas of 10 atm, 1 atm and argon gas of 1 atm. Fatigue crack growth rates were observed and effects of gaseous hydrogen and argon on the crack growth behavior were discussed.

  • PDF

Down-Scaled 3D Object for Telediagnostic Imaging Support System

  • Shin, Hang-Sik;Yoon, Sung-Won;Kim, Jae-Young;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.4
    • /
    • pp.185-191
    • /
    • 2005
  • In this paper, we proposed a downscaled 3D object technique using medical images for telediagnostic use. The proposed system consisted of downscaling/thresholding processes for building a downscaled 3D object and a process for obtaining 2D images at specific angles for diagnosis support. We used 80 slices of Digital Imaging and Communication in Medicine(DICOM) CT images as sample images and the platform-independent Java language for the experiment. We confirmed that the total image set size and transmission time of the original DICOM image set using a down-scaled 3D object decreased approximately $99\%\;and\;98.41\%,$ respectively. With additional studies, the proposed technique obtained from these results will become useful in supporting diagnosis for home and hospital care.

Biodistribution of Iodine-131-Iodomisonidazole and Imaging of Tumor Hypoxia in Mice bearing CT-26 Adenocarcinoma (CT-26 선암을 접종한 마우스에서 Iodine-131-Iodomisonidazole의 생체분포 및 종양저산소증의 영상화)

  • Kim, Hye-Won;Kim, Chang-Guhn;Yoon, Kwon-Ha;Kim, Hyun-Jeong;Juhng Seon-Kwan;Roh, Byung-Suk;Yang, David J.;Kim, E.Edmund;Lee, Hyun-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.289-297
    • /
    • 1999
  • Purpose: Misonidazole is a radiosensitizer that binds in hypoxic cells. The purpose of this study was to find out the feasibility of I-131-Iodomisonidazole (IMISO) for imaging of tumor hypoxia. Materials and Methods: Tosyl precursor was dissolved in acetonitrile and I-131-NaI was added to synthesize IMISO. Balb/c mice inoculated with CT-26 adenocarcinoma were injected with IMISO. Mice were sacrificed at 1, 2, 4, 24 hr and % of injected dose per gram of tissue (%ID/g) was determined. For scintigraphy and MRI, mouse bearing CT-26 adenocarcinoma was administered with IMISO and imaging was performed 4 hr after. Then, mouse body was fixed and microtomized slice was placed on radiographic film for autoradiography Results: %ID/g of tumor was 1.64 (1h), 0.98 (2h), 0.85 (4h) and 0.20 (24h), respectively. At 24h, %ID/g of tumor was higher than that of all other tissues except thyroid. Tumor to muscle ratio increased with time and tumor to blood ratio also increased with time and reached 1.53 at 24 hr. On autoradiogram, tumor was well visualized as an increased activity in central hypoxic area of the tumor which corresponds to the area of high signal intensity on T2-weighted MR image. On scintigraphy, tumor uptake was visualized. Conclusion: This results suggest that IMISO may have a potential for tumor hypoxia imaging in mouse model. However, further study is needed to improve it's localization in tumor tissue and to achieve acceptable images of tumor hypoxia.

  • PDF

The Evaluation of Domestic Immunoradiometric Assay Kit for Alpha-fetoprotein (Alpha-fetoprotein 측정용 국산 방사면역측정법 시약의 평가)

  • Won, Kyoung-Sook;Ryu, Jin-Sook;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.353-359
    • /
    • 2000
  • Purpose: Although ${\alpha}$-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for ${\alpha}$-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for ${\alpha}$-fetoprotein (Riakey AFP IRMA $CT^R$, Sin-Jin Medics, Seoul, Korea). Materials and Methods: We evaluated intra- and inter-assay precision, recovery rate, parallelism, and sensitivity of serum ${\alpha}$-fetoprotein measurement using Riakey AFP IRMA $CT^R$ kit. The values of ${\alpha}$-fetoprotein measured by Riakey AFP IRMA $CT^R$ kit were compared with those measured by two foreign commercial kits (${\alpha}$-fetoproteina of Radim and ${\alpha}$-feto.riabead of Abbott). Results: Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within $100{\pm}10%$. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of ${\alpha}$-fetoprotein by Riakey AFP IRMA $CT^R$ and that by two foreign commercial kits(r=0.98). Conclusion: The first Korean domestic immunoradiometric kit for ${\alpha}$-fetoprotein, Riakey AFP IRMA $CT^R$, performed well for clinical use.

  • PDF

Usefulness of $^{99m}Tc-HMPAO$ SPECT in the Localization of the Epileptic focus in Temporal Lobe Epilepsy: Comparison with EEG, MRI and CT (측두엽성간질의 간질 병소 편측화에서 $^{99m}Tc-HMPAO$ SPECT의 유용성: 뇌파, 자기 공명 영상 및 전산화 단층 영상과의 비교)

  • Kim, Jong-Ho;Kim, Jong-Soon;Kim, Sang-Eun;Choi, Chang-Woon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Lee, Nam-Soo;Myung, Ho-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.17-26
    • /
    • 1991
  • 뇌 혈류의 기능적 영상화는 간질병소의 국소화에 이용되고 있으며 측두엽성간질의 편측화에 여러가지 진단 방법이 이용되고 있으나 만족할만한 결과를 보이지 못하고 있다. 최근 PET또는 SPECT를 이용하여 측두엽성간질에서 발작 간에 측두엽 병소의 대사율 및 혈류의 감소가 나타나며, 이러한 소견은 발작 유발 병소의 편측화에 매우 유용할것이라는 보고들이 있다. 저자들은 측두엽성간질에서 간질 병소를 편측화 하는데에 $^{99m}Tc-HMPAO$ SPECT의 유용성을 평가 하고자 측두엽성간질 31예에서 발작 간의 $^{99m}Tc-HMPAO$ SPECT 소견, 뇌파, 자기 공명 영상 및 전산화 단층 소견을 비교하였다. SPECT 소견에 따른 나이, 병력 기간과 병발시 나이 등의 임상 지수 간에는 유의한 차이가 없었다. 31예의 환자중 23예에서(74.2%) 국소 뇌 혈류 감소를 보였으며 17예(54.8%)에서 측두엽에 관류 감소가 관찰 되었다. 비인두 뇌파 표준 뇌파는 24예(77.4%)에서 측두엽에 편측화를 보였으며 SPECT와 뇌파 양자가 모두 편측화된 경우 일치도는 8/12예 (66.7%) 였다. 16예에서 시행된 전산화 단층 영상은 모두 편측화를 보이지 못했으며 27예에서 시행된 자기 공명 영상에서는 단지 1예에서 편측화를 보였다. 이상의 결과로서 발작 간의 $^{99m}Tc-HMPAO$ SPECT는 측두엽성간질 병소의 편측화에 유용한 보조 검사로 생각된다.

  • PDF

Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy (전립선암 치료 시 Tomoimage에 기초한 Setup 오차에 관한 고찰)

  • Cho, Jeong-Hee;Lee, Sang-Kyu;Kim, Sei-Joon;Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Purpose: The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Materials and Methods: Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours and then the radiation therapist registered the MVCT images with the CT simulation images based on the bone based, rectal balloon based and GTV based respectively and registered image was compared with each others. The average and standard deviation of each X, Y, Z and rotation from the initial planning center was calculated for each patient. The image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours. Results: There was a significant difference in the mean variations of the rectal balloon among the methods. Statistical results based on the bone fusion shows that maximum x-direction shift was 8 mm and 4.2 mm to the y-direction. It was statistically significant (P=<0.0001) in balloon based fusion, maximum X and Y shift was 6 mm, 16mm respectively. One patient's result was more than 16 mm shift and that was derived from the rectal expansions due to the bowl gas and stool. GTV based fusion results ranging from 2.7 to 6.6 mm to the x-direction and 4.3$\sim$7.8 mm to the y-direction respectively. We have checked rotational error in this study but there are no significant differences among fusion methods and the result was 0.37$\pm$0.36 in bone based fusion and 0.34$\pm$0.38 in GTV based fusion.

  • PDF