• Title/Summary/Keyword: CT99

Search Result 348, Processing Time 0.026 seconds

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.

Definition of Tumor Volume Based on 18F-Fludeoxyglucose Positron Emission Tomography in Radiation Therapy for Liver Metastases: An Relational Analysis Study between Image Parameters and Image Segmentation Methods (간 전이 암 환자의 18F-FDG PET 기반 종양 영역 정의: 영상 인자와 자동 영상 분할 기법 간의 관계분석)

  • Kim, Heejin;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Ji, Young Hoon;Yi, Chul-Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.99-107
    • /
    • 2013
  • The surgical resection was occurred mainly in liver metastasis before the development of radiation therapy techniques. Recently, Radiation therapy is increased gradually due to the development of radiation dose delivery techniques. 18F-FDG PET image showed better sensitivity and specificity in liver metastasis detection. This image modality is important in the radiation treatment with planning CT for tumor delineation. In this study, we applied automatic image segmentation methods on PET image of liver metastasis and examined the impact of image factors on these methods. We selected the patients who were received the radiation therapy and 18F-FDG PET/CT in Korea Cancer Center Hospital from 2009 to 2012. Then, three kinds of image segmentation methods had been applied; The relative threshold method, the Gradient method and the region growing method. Based on these results, we performed statistical analysis in two directions. 1. comparison of GTV and image segmentation results. 2. performance of regression analysis for relation between image factor affecting image segmentation techniques. The mean volume of GTV was $60.9{\pm}65.9$ cc and the $GTV_{40%}$ was $22.43{\pm}35.27$ cc, and the $GTV_{50%}$ was $10.11{\pm}17.92$ cc, the $GTV_{RG}$ was $32.89{\pm}36.8$4 cc, the $GTV_{GD}$ was $30.34{\pm}35.77$ cc, respectively. The most similar segmentation method with the GTV result was the region growing method. For the quantitative analysis of the image factors which influenced on the region growing method, we used the standardized coefficient ${\beta}$, factors affecting the region growing method show GTV, $TumorSUV_{MAX/MIN}$, $SUV_{max}$, TBR in order. The result of the region growing (automatic segmentation) method showed the most similar result with the CT based GTV and the region growing method was affected by image factors. If we define the tumor volume by the auto image segmentation method which reflect the PET image parameters, more accurate and consistent tumor contouring can be done. And we can irradiate the optimized radiation dose to the cancer, ultimately.

Reduced Regional Cerebral Blood Flow in Patients with Traumatic Brain Injury Who Had No Structural Abnormalities on Magnetic Resonance Imaging : A Quantitative Evaluation of Tc-99m-ECD SPECT Findings (정상 MRI 소견을 보이는 외상성 뇌손상 환자에서 국소뇌혈류량의 이상)

  • Kim, Nam-Hee;Chung, Young-Ki
    • Korean Journal of Biological Psychiatry
    • /
    • v.9 no.2
    • /
    • pp.152-158
    • /
    • 2002
  • Background & Purpose:Neuropsychological disorders after traumatic brain injury(TBI) are poorly correlated with structural lesions detected by structural neuroimaging techniques such as computed tomography(CT) scan or magnetic resonance imaging(MRI). It is well known that patients with TBI have cognitive and behavioral disorders even in the absence of structural lesions of the brain. This study investigated whether there are abnormalities of regional cerebral blood flow(rCBF) in TBI patients without structural abnormality on MRI, using technetium 99m ethyl cysteinate dimer(Tc-99m-ECD) single photon emission computed tomography(SPECT) scans. Materials and Methods:Twenty-eight TBI patients without structural abnormality on MRI(mild, n=13/moderate, n=9/severe, n=6) and fifteen normal controls were scanned by SPECT. A voxel-based analysis using statistical parametric mapping(SPM) was performed to compare the patients with the normal controls. Results:rCBF was reduced in the right uncus and the right lateral orbitofrontal gyrus in the TBI patients. However, no increase of rCBF was noted in the patients in comparison to the normal controls. Conclusions:These results suggest that the TBI patients, even in the absence of structural lesion of the brain, may have dysfunction of the brain, particularly of the orbitofrontal and anterior pole of the temporal cortex. They also suggest that SPECT can be a useful method to identify brain dysfunctions in combination with structural brain imaging and neuropsychological tests.

  • PDF

Quantitative Analysis of Regional Cerebral Blood Flow using $^{99m}Tc-HMPAO$ SPECT in Parkinson's Disease (파킨슨병에서 $^{99m}Tc-HMPAO$ SPECT를 이용한 국소뇌혈류의 정량적 분석)

  • Lee, Myung-Chul;Bae, Sang-Kyun;Lee, Myung-Hae;Chung, June-Key;Koh, Chang-Soon;Roh, Jae-Kyu;Myung, Ho-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.251-256
    • /
    • 1992
  • Regional cerebral blood flow were measured in 10 patients with Parkinson's disease and 12 normal persons using $^{99m}Tc-HMPAO$ SPECT. Reconstructed images were interpreted qualitatively and were compared with those findings of CT. For the quantitative analysis, six pairs of region of interest matched with the perfusion territories of large cerebral arteries and cerebellar hemisphere were determined. From the count values, indices showing the degree of asymmetry between right and left cerebral or cerebellar hemisphere, cerebral asymmetry index (ASI) and percent index of cerebellar asymmetry (PIA), and an index showing change of each region, region to cerebellum ratio (RCR) were obtained. ASI of normal persons and patients were $0.082{\pm}0.033$ and $0.108{\pm}0.062$, respectively and PIA were $-0.4{\pm}0.7%$ and $-0.7{\pm}1.0%$, respectively, which showed no statistically significant difference between normal persons and patients. Among 10 RCR's, those of both regions of basal ganglia and both regions of anterior cerebral artery were significantly reduced. We concluded that the most significant reduction of regional cerebral blood flow in patients with Parkinson's disease was observed in the regions of basal ganglia and in the regions of anterior cerebral artery, and the degree of change in hemispheric blood flow was similar in both hemisphere.

  • PDF

Hepatic Arterial Perfusion Scintigraphy with Tc-99m-Macroaggregated Albumin in Hepatocellular Carcinoma (Tc-99m-MAA를 이용한 간세포암의 경동맥 관류스캔)

  • Kim, Gang-Deuk;Sohn, Kwang-Joon;Min, Kyung-Yoon;Kwon, Young-Mi;Kim, Chang-Guhn;Noh, Byung-Suk;Won, Jong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.350-356
    • /
    • 1994
  • Purpose : Hepatic arterial perfusion scintigraphy with Tc-99m-macroggregated albumin (HAPS) study was carried out in 16 patients with hepatocellular carcinoma(HCC) and in six patients without liver tumor to evaluate HAPS findings of hepatocellular carcinoma and usefullness of HAPS. Materials and Methods : HAPS with planar and SPECT study were performed in 22 patients after conventional hepatic or celiac arteriography. For HAPS study, 4-5 mCi of MAA mixed with 2ml of saline was injected into proper hepatic artery or its distal branches at the rate of approximately 1ml/sec. We analysed 21 HCCs over 2cm in diameter(average diameter; 6.4cm) and 17 of 21 HCCs were over 4cm in diameter(Table 1). CT, sonography and angiography were performed within two week in all 16 patients and liver scan was performed in 12 patients. Results : Three different pattern of tumor perfusion were observed in 16 patients with HCC (Table 2). 1) diffuse increased perfusion in 16 of 21(76%)(Fig. 1) 2) increased peripheral perfusion in 4 of 21(19%) (Fig. 2) 3) diffuse decreased perfusion in 1 of 21 (5%) Arteriovenous shunt indicated by lung uptake of MAA were observed in 9 of 16(56%)(Fig. 4). In contrast, angiography demonstrates arteriovenous shunt in 2 of 16(13%). There was no accumulation of radioactivity on RBC-blood pool scan in all six patients with HCC examined (Fig. 1). Conclusion : HAPS is useful study in evaluation of perfusion pattern or vascularity of HCC and in detection of arteriovenous shunt.

  • PDF

Synthesis and radiolabeling of PEGylated dendrimer-G2-Gemifloxacin with 99mTc to Biodistribution study in rabbit

  • Mohtavinejad, Naser;Dolatshahi, Shaya;Amanlou, Massoud;Ardestani, Mehdi Shafiee;Asadi, Mehdi;Pormohammad, Ali
    • Advances in nano research
    • /
    • v.10 no.5
    • /
    • pp.461-470
    • /
    • 2021
  • Infection is one of the major mortality causes throughout the globe. Nuclear medicine plays an important role in diagnosis of deep infections such as osteomyelitis, arthritis infection, heart valve and heart prosthesis infections. Techniques such as labeled leukocytes are sensitive and selective for tracking the inflammations but they are not suitable for differentiating infection from inflammation. Anionic linear-globular dendrimer-G2 was synthesized then conjugation to gemifloxacin antibiotic. The structures were identified by FT-IR, 1H-NMR, C-NMR, LC-MS and DLS. The toxicity of gemifloxacin and dendrimer-gemifloxacin complex was compared by MTT test. Dendrimer-G2-gemifloxacin was labeled by Technetium-99m and its in-vitro stability and radiochemical purity were investigated. In-vivo biodistribution and SPECT imaging were studied in a rabbit model. Identify and verify the structure of the each object was confirmed by FT-IR, 1H-NMR, C-NMR and LC-MS, also, the size and charge of this compound were 128 nm and -3/68 mv respectively. MTT test showed less toxicity of the dendrimer-G2-gemifloxacin than free gemifluxacin (P < 0.001). Radiochemical yield was > %98. Human serum stability was 84% up to 24 h. Biodistribution study at 50 min, 24 and 48 h showed that the complex is significantly absorbed by the intestine and accumulation in the lungs and affects them, finally excreted through the kidneys, biodistribution results are consistent with results from full image means of SPECT/CT technique.

TRANSVERSE CHANGE OF THE PROXIMAL SEGMENT AFTER BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY IN MANDIBULAR PROGNATHISM USING COMPUTED TOMOGRAPHY (하악전돌증환자에서 하악지시상분할골절단술 후 전산화단층촬영을 이용한 근심골편의 횡적인 변화에 관한 연구)

  • Kim, Young-Joon;Kook, Min-Suk;Park, Hong-Ju;Shet, Uttom Kumar;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.232-240
    • /
    • 2008
  • Purpose: This study was performed to evaluate transverse changes of proximal segment after bilateral sagittal split ramus osteotomy (BSSRO) using 3-D CT in mandibular prognathism. Patients and methods: Twenty-two patients who underwent BSSRO for mandibular set-back in class III malocclusion without facial asymmetry were examined. Miniplates were used for the fixation after BSSRO. Facial CT was taken before and after BSSRO within 3 months. Frontal-ramal inclination (FRI), inter-gonial width (IGW) and intercondylar width (ICW) were measured in 3-D CT images using V-works $4.0^{TM}$ program. Student t-test was used to compare the changes between pre- and post-operative measurements using SPSS 10.0 program. Results: 1. Mean peroperative FRI value ($12.87{\pm}3.43^{\circ}$) was slightly increased to postoperative value ($14.13{\pm}3.72^{\circ}$) (p < 0.05). The average FRI increased 10.42% and the range was from $-2.46^{\circ}$ to $3.34^{\circ}$. 2. Mean peroperative IGW ($99.01{\pm}5.36$) was slightly decreased to postoperative IGW ($96.51{\pm}5.88mm$) (p < 0.05). The average IGW decreased 2.52 % and the range was from $-6.61^{\circ}$ to 0.91 mm. 3. Mean preoperative ICW ($125.01{\pm}5.30mm$) was slightly decreased to postoperative ICW ($125.40{\pm}5.45mm$) (p < 0.05). There is no significant difference between pre- and post-operative ICW. 4. There was significant correlationship between FRI difference and IGW difference (p < 0.05). Conclusions: These results indicate that the lower ramus of the proximal segment is moved inward after BSSRO procedure for mandibular set-back.

5,10-Methylenetetrahydrofolate Reductase Polymorphisms and Colon Cancer Risk: a Meta-analysis

  • Fang, Xin-Yu;Xu, Wang-Dong;Huang, Qian;Yang, Xiao-Ke;Liu, Yan-Yan;Leng, Rui-Xue;Pan, Hai-Feng;Ye, Dong-Qing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.19
    • /
    • pp.8245-8250
    • /
    • 2014
  • Previous studies investigating the association between 5,10-methylenetetrahydrofolate reductase (MTHFR) gene polymorphisms and colon cancer risk have generated conflicting results. The aim of our meta-analysis was to clarify the precise association. A systematic literature search was conducted to identify all relevant studies. Pooled odds ratio (ORs) with 95% confidence interval (CI) were used to estimate the strength of the association. In this meta-analysis, a total of 13 articles, involving 5,386 cases and 8,017 controls met the inclusion criteria. Overall, a significant association was found between colon cancer risk and the MTHFR C667 polymorphism (TT vs CC+CT: OR=0.79; 95%CI=0.65-0.96; p=0.017). Stratification by ethnicity revealed that MTHFRC667 was associated with colon cancer risk in the non-Asian group (TT vs CC+CT:OR=0.77, 95%CI=0.68-0.89, p=0.000; TT vs CC: OR=0.84, 95%CI=0.73-0.97, p=0.016). Stratification by source of control indicated that MTHFR C667 also correlated with colon cancer risk in the population-based subgroup (TT vs CC: OR=0.85, 95%CI=0.74-0.97, p=0.017; TT vs CC+CT: OR=0.78, 95%CI=0.68-0.89, p=0.000) and hospital-based subgroup (TT vs CC+CT: OR=0.65, 95%CI=0.49-0.86, p=0.003). However, risk was significantly increased for MTHFR A1298C polymorphisms and colon cancer risk in hospital-based studies (C vs A: OR=1.52, 95%CI=1.26-1.83, p=0.000; CC+AC vs AA: OR=1.93, 95%CI=1.47-2.49, p=0.000) but reduced in population-based studies (CC vs AA: OR=0.83, 95%CI=0.70-0.99, p=0.042). In conclusion, the results of our meta-analysis suggest that the MTHFR C667 polymorphism is associated with reduced colon cancer risk, especially for non-Asian populations.

Diagnostic Performance of Diffusion - Weighted Imaging for Multiple Hilar and Mediastinal Lymph Nodes with FDG Accumulation

  • Usuda, Katsuo;Maeda, Sumiko;Motono, Nozomu;Ueno, Masakatsu;Tanaka, Makoto;Machida, Yuichiro;Matoba, Munetaka;Watanabe, Naoto;Tonami, Hisao;Ueda, Yoshimichi;Sagawa, Motoyasu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6401-6406
    • /
    • 2015
  • Background: It is sometimes difficult to assess patients who have multiple hilar and mediastinal lymph nodes (MHMLN) with FDG accumulation in PET-CT. Since it is uncertain whether diffusion-weighted magnetic resonance imaging (DWI) is useful in the assessment of such patients, its diagnostic performance was assessed. Materials and Methods: Twenty-three patients who had three or more stations of hilar and mediastinal lymph nodes with SUVmax of 3 or more in PET-CT were included in this study. Results: For diagnosis of disease, there were 20 malignancies (lung cancers 17, malignant lymphomas 2 and metastatic lung tumor 1), and 3 benign cases (sarcoidosis 2 and benign disease 1). For diagnosis of lymph nodes, there were 7 malignancies (metastasis of lung cancer 7 and malignant lymphoma 1) and 16 benign lymphadenopathies (pneumoconiosis/silicosis 7, sarcoidosis 4, benign disease 4, and atypical lymphocyte infiltration 1). The ADC value ($1.57{\pm}0.29{\times}10^{-3}mm^2/sec$) of malignant MHMLN was significantly lower than that ($1.99{\pm}0.24{\times}10^{-3}mm^2/sec$) of benign MHMLN (P=0.0437). However, the SUVmax was not significantly higher ($10.0{\pm}7.34$ as compared to $6.38{\pm}4.31$) (P=0.15). The sensitivity (86%) by PET-CT was not significantly higher than that (71%) by DWI for malignant MHMLN (P=1.0). The specificity (100%) by DWI was significantly higher than that (31%) for benign MHMLN (P=0.0098). Furthermore, the accuracy (91%) with DWI was significantly higher than that (48%) with PET-CT for MHMLN (P=0.0129). Conclusions: Evaluation by DWI for patients with MHMLN with FDG accumulation is useful for distinguishing benign from malignant conditions.

The Data Transmission of Image Storage System of PACS (PACS내 영상저장 장치의 데이터 전송)

  • Cho, EuyHyun;Park, Jeongkyu
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.785-791
    • /
    • 2018
  • Recently, Disk array is widely used as a long term storage device in PACS, but reliability is not enough in relation to annual failure rate of disk. Between October 2016 and February 2017, we scanned the serial port of the hard disk while reading or storing medical images on a PACS reader. The data rate was calculated from the data stored in HDD 99ea that were used in the PCAS image storage device and in HDD 101ea that were used in the Personal Computer. When a CT image was read from a PACS reader, Reading was 87.8% and Writing was 12.2% in units of several tens of megabytes or less. When the CT image was stored in the PACS reader, Reading was 11.4% and Writing was 88.6% in units of several tens of megabytes or less. While reading the excel file on the personal computer, Reading was 75% and Writing was 25% in less than 3 MB, and In the process of storing the excel file on the personal computer, Reading was carried out by 38% and Writing was carreid out 62% in the units of 3 MB or less. The transfer rate of the hard disk used in the PACS image storage device was 10 GB/h, and the transfer rate per hour of the hard disk of the personal computer was 5 GB / h. Annual failure rate of hard disk of image storage system is 0.97 ~ 1.13%, Annual failure rate of Hard Disk of personal computer is 0.97 ~ 1.13%. the higher transfer rate is, the higher annual failure rate is. These results will be used as a basis for predicting the life expectancy of the hard disk and the annual failure rate.