• Title/Summary/Keyword: CT-reconstruction

Search Result 480, Processing Time 0.026 seconds

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Supercharged Technique in TRAM flap Breast Reconstruction (과급 횡복직근피판술(Supercharged TRAM)을 이용한 유방재건술)

  • Yang, Jung-Dug;Song, Jae-Min;Lee, Sang-Yun;Chung, Ho-Yun;Cho, Byung-Chae;Park, Ho-Yong;Jung, Jin-Hyang
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.577-582
    • /
    • 2010
  • Purpose: When reconstruction for patients who have the large contralateral breast or a following large defect after mastectomy is required, conventional pedicled TRAM flap shows the unpredictable occurrence of fat necrosis and skin flap loss in a relatively high percentage due to insufficient blood supply. In an effort to obtain more stable TRAM flap blood circulation, we have performed a supercharged technique using deep inferior epigastric perforators (DIEP) with conventional pedicled TRAM flap. Methods: From September of 2006 to December of 2008, Fourteen supercharged TRAM flap were performed for breast reconstruction after modified radical mastectomy. The contralateral DIEP was anastomosed to the internal mammary vessels in contralateral pedicled TRAM flap or thoracodorsal vessels in ipsilateral pedicled TRAM flap. Nutrient vessels were selected by Multi-Detector Computed tomography (MD-CT) modalities. For the nutrient vessel, we used deep inferior epigastric vessels (DIEV) of the ipsilateral side in 8 patients, DIEV of the contralateral side in 6 patients. In addition, for the recipient vessel, we used thoracodorsal vessels in 8 patients, internal mammary vessels in 5 patients, intercostals artery perforators in 1 patient. Results: The mean age was 46.8 years and the average follow-up interval was 14 months. There were 11 immediate and 3 delayed breast reconstructions. Fat necrosis incidence rate in supercharged TRAM group was lower than in conventional TRAM flap group. There were no differences of the incidences of abdominal hernia in both groups. Conclusion: The supercharged TRAM flap produces an improvement in vascularity that permits use of all four zones of the flap. The breast reconstruction with supercharged technique is reliable and valuable methods which provide sufficient soft tissue from abdomen without significant complications.

Geometry of Resident's ridge with Multidetector-Row Computed Tomograph Image (다중검출기 컴퓨터 단층 영상 분석을 이용한 Resident's ridge의 형태학적 연구)

  • Roh, Jeong-Ho;Min, Byoung-Hyun;Park, Jeong-Wook;Ahn, Byung-Moon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.40-44
    • /
    • 2008
  • Purpose: The purpose of this study was to report the real geometry of Resident's ridge doing in anterior cruciate ligament reconstruction Materials and Methods: From Jan 2007 to Aug 2007, 48 cases which had normal distal femoral condyle analyzed with Multidetector-Row Computed Tomography. Resident's ridge was defined as change of height above 1 mm in lateral wall of intercondylar notch. Anterior-posterior length of intercondylar notch, length and height of Resident's ridge, distance of Resident's ridge from posterior cortex were estimated with 3-D reconstruction using $Lucion^{(R)}$ program. Results: Cases were $59{\pm}16$ years olds and male was 16 cases, female was 32 cases. 9 cases had no Resident's ridge, anterior-posterior length of intercondylar notch was $25.4{\pm}3.5$ mm, average of length and height of the Resident's ridge was $8.2{\pm}2.6,\;3.5{\pm}1.5$ mm. Distance of the Resident's ridge from posterior cortex was $7.6{\pm}2.6$ mm. Conclusion: Resident's ridge was used as landmark in anterior cruciate ligament reconstruction, which presented in many cases and which had distinct length and height.

  • PDF

Angiogenesis in newly regenerated bone by secretomes of human mesenchymal stem cells

  • Katagiri, Wataru;Kawai, Takamasa;Osugi, Masashi;Sugimura-Wakayama, Yukiko;Sakaguchi, Kohei;Kojima, Taku;Kobayashi, Tadaharu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.8.1-8.8
    • /
    • 2017
  • Background: For an effective bone graft for reconstruction of the maxillofacial region, an adequate vascular network will be required to supply blood, osteoprogenitor cells, and growth factors. We previously reported that the secretomes of bone marrow-derived mesenchymal stem cells (MSC-CM) contain numerous growth factors such as insulin-like growth factor (IGF)-1, transforming growth factor $(TGF)-{\beta}1$, and vascular endothelial growth factor (VEGF), which can affect the cellular characteristics and behavior of regenerating bone cells. We hypothesized that angiogenesis is an important step for bone regeneration, and VEGF is one of the crucial factors in MSC-CM that would enhance its osteogenic potential. In the present study, we focused on VEGF in MSC-CM and evaluated the angiogenic and osteogenic potentials of MSC-CM for bone regeneration. Methods: Cytokines in MSC-CM were measured by enzyme-linked immunosorbent assay (ELISA). Human umbilical vein endothelial cells (HUVECs) were cultured with MSC-CM or MSC-CM with anti-VEGF antibody (MSC-CM + anti-VEGF) for neutralization, and tube formation was evaluated. For the evaluation of bone and blood vessel formation with micro-computed tomography (micro-CT) and for the histological and immunohistochemical analyses, a rat calvarial bone defect model was used. Results: The concentrations of IGF-1, VEGF, and $TGF-{\beta}1$ in MSC-CM were $1515.6{\pm}211.8pg/mL$, $465.8{\pm}108.8pg/mL$, and $339.8{\pm}14.4pg/mL$, respectively. Tube formation of HUVECs, bone formation, and blood vessel formation were increased in the MSC-CM group but decreased in the MSC-CM + anti-VEGF group. Histological findings suggested that new bone formation in the entire defect was observed in the MSC-CM group although it was decreased in the MSC-CM + anti-VEGF group. Immunohistochemistry indicated that angiogenesis and migration of endogenous stem cells were much more abundant in the MSC-CM group than in the MSC-CM + anti-VEGF group. Conclusions: VEGF is considered a crucial factor in MSC-CM, and MSC-CM is proposed to be an adequate therapeutic agent for bone regeneration with angiogenesis.

Effect of Anteromedial Cortex Oblique Angle on Change of Tibial Posterior Slope Angle in High Tibial Osteotomy Using Computer Assisted Surgery (CAS) (Computer Assisted Surgery(CAS)를 이용한 개방형 근위경골절골술 시 전내측피질골경사각이 경골후방경사각에 미치는 영향)

  • Lee, Ho-Sang;Kim, Jay-Jung;Wang, Joon-Ho;Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.351-361
    • /
    • 2012
  • The leading surgical method for correcting the misalignment of the varus and valgus in the knee joint is the high tibial osteotomy (HTO). In the opening wedge HTO (OWHTO), there is no concern about damaging the peroneal nerve on the lateral tibia of the proximal fibula. OWHTO has been the preferred choice, as the opening of the correction angle can be modulated during the operation. The correction of the varus and valgus on the coronal plane are performed adroitly. Nevertheless, there have been numerous reports of unintended changes in the medial tibial plateau and posterior slope angle (PSA). The authors have developed an HTO method using computer-assisted surgery with the aim of addressing the abovementioned problems from an engineer's perspective. CT images of the high tibia were reconstructed three-dimensionally, and a virtual osteotomy was performed on a computer. In addition, this study recommends a surgical method that does not cause changes in the PSA after OWHTO. The results of the study are expected to suggest a clear relationship between the anteromedial cortex oblique angle of each patient and the PSA, and an optimal PSA selection method for individuals.

Acute Type A Aortic Dissection Mimicking Penetrating Atherosclerotic Ulcer (침투성 동맥경화성 궤양과 흡사한 급성 A형 대동맥 박리증 -1l례 보고 -)

  • Choi, jae-Sung;Kwak, Jae-Gun;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.36 no.1
    • /
    • pp.30-34
    • /
    • 2003
  • As classical acute aortic dissection, atherosclerotic penetrating ulcers and intramural hematoma have different pathophysiology and natural history, treatment strategy should be different and, therefore, accurate differential diagnosis is necessary. However, these three aortic diseases may be indistinguishable by clinical observation and even by various diagnostic modalities such as cardiac echocardiography, CT and MRI. The patients was a 71-year-old female with chief complaints of anterior chest pain, nausea and vomiting which occurred suddenly 3 days before admission. CT angiographic with 3 dimensional reconstruction shows intramural hematoma in ascending aorta, aortic arch, descending thoracic aorta and right brachiocephalic trunk, heompericardium, and blood in mediastinum and both pleural cavities. The CT angiographic finding of focal out-bulging in the ascending thoracic aorta was diagnosed as penetrating atherosclerotic ulcer. The patient underwent emergency operation under a preoperative diagnosis of penetrating atherosclerotic ulcer with a sign of aortic rupture. In the intraoperative findings, however, intimal tear was seen in the anterior portion of the ascending aorta about 1cm below the brachiocephalic trunk and falselumen appeared after hematoma was removed from the layer of tunica media. We report a case of type A aortic dissection which mimicked clinical and diagnostic features of penetrating atherosclerotic ulcer.

3-D CT EVALUATION OF CONDYLE HEAD POSITION, MANDIBULAR WIDTH, AND MANDIBULAR ANGLE AFTER MANDIBULAR SETBACK SURGERY (3-D CT를 이용한 악교정수술후의 하악 과두 위치와 하악폭경 및 하악각의 평가)

  • Kim, Jae-Won;Lee, Dong-Hyun;Lee, Su-Youn;Kim, Jae-Hyun;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.229-239
    • /
    • 2009
  • The purpose of this study is to evaluate the change in condylar position, width, and angle before and after orthognathic surgery using 3-dimensional computed tomograph. Pre and posterative 3-D CT was taken on 38 patients and through axial, frontal, sagittal measurements and by 3-dimensional reconstruction, the changes in condylar postion, mandibular width and angle were analyzed and others such as the difference in gender, operation and fixation method, setback length and in relation with temporomandibular disorders were done together too. The results were as follows: The inward rotation of condyle in axial condylar angle, the forward movement of right condyle in sagittal anterior-posterior distance, the superior movement of both condyles in sagittal superior-inferior distance, the decrease in gonial angle, the increase in mandibular width, the decrease in distance between the axial coronoid process distance and the increase in the frontal intercondylar distance were statistically significant. There were no statistically significant changes in gender difference, however in the difference in operation method, change in the gonial angle was observed and there was more change in bilateral sagittal split osteotomy group compared to two-jaw surgery group. In the difference in fixation method, the decrease in axial coronoid process distance and the change in sagittal anterior-posterior distance were statistically significant. In the difference in setback, the increase in setback didn't relate directly with the increased change in condyle position. In the relation with temporomandibular disorder, changes in left axial condylar angle and axial coronoid process distance were statistically significant. Changes in condylar position could be observed after the orthognathic surgery but it doesn't seem to have much of a clinical importance. The orthognathic surgery is effective in decreasing the mandibular angle, and it is not related with the temporomandibular disorder.

Treatment of Blow-out Fractures Using Both Titanium Mesh Plate and Porous Polyethylene (Medpor®) (광범위한 안와파열골절에서 Titanium Mesh Plate와 Porous Polyethylene (Medpor®) 동시 사용의 유용성)

  • Gu, Ja Hea;Won, Chang Hoon;Dhong, Eun-Sang;Yoon, Eul-Sik
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.2
    • /
    • pp.85-90
    • /
    • 2010
  • Purpose: The goals of a blow-out fracture reconstruction are to restore the osseous continuity, provide support for the orbital contents and prevent functional and anatomic defects. Over the past several years, a range of autogenous and synthetic implants have been used extensively in orbital reconstructions. None of these implants have any absolute indications or contraindications in certain clinical settings. However, in extensive blow-out fractures, it is difficult to restore support of the orbital contents, which can cause more complications, such as enophthalmos. This study examined the clinical outcomes of extensive or comminuted blow-out fractures that were reconstructed by the simultaneous use of a titanium mesh plate and $Medpor^{(R)}$. Methods: Eighty six patients with extensive orbital fractures, who were admitted between March 1999 and February 2007, were reviewed retrospectively. The patients' chart and CT were inspected for review. Twenty three patients were operated on with both a titanium mesh plate (Matrix MIDFACE pre-formed orbital plate, Synthes, USA) and $Medpor^{(R)}$ (Porex, GA, USA). The patients underwent pre-operative CT scans to evaluate the fracture site and measure the area of the fracture. A transconjunctival approach was used, and titanium mesh plates were inserted subperiosteally with screw fixation. $Medpor^{(R)}$ was inserted above the titanium mesh plate. The patients were evaluated post-operatively for enophthalmos, diplopia, sensory disturbances and eyeball movement for a period of at least 6 months. Results: No implant-related complications were encountered during the follow-up period. Enophthalmos occurred in 1 patient, 1 patient had permanent sensory disturbance, and 3 patients complained of ocular pain and fatigue, which recovered without treatment. Although there were no significance differences between groups, the use of 2 implants had fewer complications. Therefore, it can be an alternative method for treating blow out fractures. Conclusion: The use of both a titanium mesh plate and $Medpor^{(R)}$ simultaneously may be a safe and acceptable technique in the reconstruction of extensive blow-out fractures.

VR, AR Simulation and 3D Printing for Shoulder and Elbow Practice (VR, AR 시뮬레이션 및 3D Printing을 활용한 어깨와 팔꿈치 수술실습)

  • Lim, Wonbong;Moon, Young Lae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.175-179
    • /
    • 2016
  • Recent advances in technology of medical image have made surgical simulation that is helpful to diagnosis, operation plan, or education. Improving and enhancing the medical imaging have led to the availability of high definition images and three-dimensional (3D) visualization, it allows a better understanding in the surgical and educational field. The Real human field of view is stereoscopic. Therefore, with just 2D images, stereoscopic reconstruction process through the surgeon's head, is necessary. To reduce these process, 3D images have been used. 3D images enhanced 3D visualization, it provides significantly shorter time for surgeon for judgment in complex situations. Based on 3D image data set, virtual medical simulations, such as virtual endoscopy, surgical planning, and real-time interaction, have become possible. This article describes principles and recent applications of newer imaging techniques and special attention is directed towards medical 3D reconstruction techniques. Recent advances in technology of CT, MR and other imaging modalities has resulted in exciting new solutions and possibilities of shoulder imaging. Especially, three-dimensional (3D) images derived from medical devices provides advanced information. This presentation describes the principles and potential applications of 3D imaging techniques, simulation and printing in shoulder and elbow practice.