저 선량 전산화단층촬영의 관전압과 적응식 통계적 반복 재구성법 적용에 따른 영상평가 및 피폭선량 (Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography)

  • 문태준;김기정;이혜남
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.261-267
    • /
    • 2017
  • 저 선량 흉부 전산화단층촬영(low dose computed tomography; LDCT)검사 시 기존의 검사방법인 필터보정역투영법인 FBP(filted back projection)와 적응식 통계적 반복 재구성법인 ASIR(adaptive statistical iterative reconstruction)의 적용 및 관전압 변화에 따른 영상의 화질과 피폭선량을 비교 평가해 보고자 하였다. 흉부 phantom을 이용하여 재구성방법에 따라 FBP와 ASIR적용(10%, 20%)을 하였고, 관전압(100kVp, 120kVp)에 변화를 주어 실험을 하였다. 화질평가를 위해 back-ground noise와 signal-noise ratio(SNR), contrast-noise ratio(CNR)를 구하였으며, 선량평가를 위해 CTDIvol과 DLP를 구하였다. 화질평가에 있어 kVp에 따른 ascending aorta(AA) SNR과 inpraspinatus muscle(IM) SNR은 AA SNR과 IM SNR은 유의한 차이가 있었다(p < 0.05). 선량평가에 있어 CTDIvol과 DLP는 유의한 차이가 있었으며(p < 0.05), CTDIvol은 120 kVp, FBP가 2.6 mGy, 120 kVp, 10%-ASIR가 2.38 mGy, 120kVp, 20%-ASIR가 2.17 mGy로 0.43 mGy 감소하였고, 100 kVp, FBP가 1.61 mGy, 100 kVp, 10%-ASIR가 1.48 mGy, 100 kVp, 20%-ASIR가 1.34 mGy로 0.27 mGy 감소하였다. 또한 DLP에서는 120 kVp, FBP가 $103.21mGy{\cdot}cm$, 120 kVp, 10%-ASIR가 $94.57mGy{\cdot}cm$, 120 kVp, 20%-ASIR가 $85.94mGy{\cdot}cm$$17.27mGy{\cdot}cm$(16.7%) 감소하였고, 100 kVp, FBP가 $63.87mGy{\cdot}cm$, 100 kVp, 10%-ASIR가 $58.54mGy{\cdot}cm$, 100 kVp, 20%-ASIR가 $53.25mGy{\cdot}cm$$10.62mGy{\cdot}cm$(16.7%)로 감소하였다. 재구성방법에 따른 FBP와 ASIR 10%, 20%에서는 화질의 변화 없이 선량을 줄일 수 있어 흉부 low dose CT검사 시 ASIR 20%적용하여 검사하는 것이 좋으며, 관전압 변화에 따른 120 kVp와 100 kVp에서는 선량은 크게 줄어들었지만, noise가 증가하여 화질이 떨어지는 것으로 나타났다.

사지에 발병한 카포시육종의 방사선치료를 위한 물볼루스 기구의 유용성 고찰 (Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients)

  • 안승권;김용배;이익재;송태수;손동민;장영재;조정희;김주호;김동욱;조재호;서창옥
    • Radiation Oncology Journal
    • /
    • 제26권3호
    • /
    • pp.189-194
    • /
    • 2008
  • 목 적: 본 연구팀은 사지에 발병한 카포시육종의 방사선치료를 위하여, 물볼루스를 사용할 수 있는 기구를 고안하였고, 쌀볼루스 사용시와 비교하여 유용성을 평가하고자 하였다. 대상 및 방법: 환자가 앙와위 자세에서 하지를 삽입 할 수 있는 폴리스틸렌 상자를 만들고 비닐 재질의 진공비닐을 집어 넣어 물이 누수 되지 않도록 결합하였으며, 진공비닐안에 하지와 물 사이의 공기를 없애기 위해 진공 밸브와 진공 펌프를 연결하여 공기를 제거하였다. 본 연구에서 제작한 물기반 볼루스의 선량 균질도를 비교 평가하기 위해 진공비닐에 하지 팬텀을 삽입한 후 폴리스틸렌 상자에 직접 쌀을 채운 경우, 비닐봉지에 쌀을 담아서 넣은 경우, 그리고 물을 직접 채운 경우에 대해 전산화단층촬영을 시행하였다. 방사선치료계획시스템을 사용하여 공기층의 부피에 의한 밀도의 변화를 분석하였다. 또한 선형가속기를 사용하여 전산화단층 모의치료기와 동일한 셋업에서 하지 팬텀에 필름을 감고, 열형광선량계 6개를 조사야 안에 균등하게 붙여서, 대향이문 조사하여 선량의 균질도 및 선량 값을 측정하였다. 결 과: 각 세 종류 실험의 밀도 측정결과 물볼루스를 기준으로 쌀을 직접 넣은 경우는 14% 감소했으며, 쌀을 비닐 봉지에 나누어 넣은 경우는 18% 감소하였다. 필름의 분석 결과 물볼루스가 쌀볼루스보다 균질도가 $4{\sim}4.4%$ 정도 우수한 것으로 나타났다. 열형광선량계 측정 평균값 분석결과 물볼루스를 기준으로 쌀을 직접 넣은 경우는 3.4% 증가했으며, 쌀을 비닐봉지에 나누어 넣은 경우는 4.3% 증가하였다. 결 론: 자체 제작한 물볼루스 기구는 육안으로 치료 조사야를 확인할 수 있어 셋업의 정확성을 높였으며, 진공 밸브와 진공 펌프를 사용하여 공기층을 감소시켜 치료의 정확성을 높이는 동시에 목적 종양에 균질도가 높은 선량을 부여 할 수 있는 좋은 방안이라 할 수 있다.

64 다중채널 검출기 전산화단층촬영에서 환자고정자 재질에 대한 영상평가 (Image Evaluation for A Kind of Patient Fixing Pad in 64 Multi-Channel Detector Computed Tomograph)

  • 김기복;구은회
    • 한국융합학회논문지
    • /
    • 제7권1호
    • /
    • pp.89-95
    • /
    • 2016
  • 본 실험의 목적은 두부 팬텀 MDCT에서 5 종류의 환자고정자 패드를 이용하여 노이즈, 신호대 잡음비, 선량에 대하여 방사선감수성이 민감한 안와 와 기저핵 부위를 기준으로 영상의 질을 평가하고자 하였다. 영상의 노이즈는 AP가 가장 높게 나타났으며, 신호대 잡음비는 가장 낮게 나타났다. 환자고정자 재료 5(UP, RP, PP SP, AP) 종류 중 신호대 잡음비가 가장 높은 것은 UP 이었지만 RP, PP와 더불어 통계적 유의성이 없었고(p>0.05), UP, RP, PP와 SP, AP는 통계적 유의성이 있었다(p<0.05). 이러한 원인은 방사선을 입사했을 때 SOML의 기준선에 따른 검출기의 흡수선량정도와 각각의 재질의 성분에 따라 방사선 흡수선량이 다르기 때문에 노이즈 차이를 발생하게 된다. 안와 기저핵의 CTDIvol(mGy)와 DLP 값은 각각 56.95, 911.50로 환자고정자 재료에 따라 선량의 차이는 없었다. 결론적으로, 5 종류의 환자고정자 패드는 각각의 차이를 구별할 수 있었으며 SP, AP 보다 UP, RP, PP 사용은 임상적으로 유용한 정보를 제공할 수 있다.

방사선치료계획장치로 설계된 Cerrobend 선량보상체와 전자 선량보상체의 제작 및 특성 분석 (The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System)

  • 나병식;정웅기;안성자;남택근;윤미선;송주영
    • 한국의학물리학회지:의학물리
    • /
    • 제16권2호
    • /
    • pp.82-88
    • /
    • 2005
  • 상용화된 방사선 치료계획 장치에서 제공하는 선량보상체(compensator) 설계 기능의 타당성 을 검증하고자 Cerrobend 재료를 대상으로 한 고밀도의 선량보상체 설계 및 제작과 동적다엽콜리메이터를 활용한 전자 선량보상체(Electronic Compensator)의 구현을 통해 그 기능을 분석하였다. 5개의 두께가 다른 영역으로 구성한 팬텀을 대상으로 전산화단층촬영(CT) 영상을 획득하고, 기준 깊이에서 균일한 선량분포를 형성하도록 방사선치료계획장치(RTP)에서 선량보상체를 설계하였다. Cerrobend 선량보상체 주조 틀을 제작하기 위해 컴퓨터로 자동 제어되는 스티로폼 절삭기를 사용하였고, 전자선량보상체를 구현하기 위해 다엽콜리메이터를 사용하였으며, 선량분포의 측정을 위해서 선량측정용 필름을 사용하였다. 선량보상체를 적용하지 않았을 경우, 선량분포에서 $\pm13.93 cGy$의 편차를 보였으나, Cerrobend 선량보상체와 전자선량보상체를 적용하였을 경우, 각각 $\pm0.99 cGy$$\pm1.82cGy$의 편차를 보여 선량분포의 균일도를 높이는 선량보상체로서 기능을 구현함을 증명하였다. 방사선치료계획장치에서 계획된 기준 선량값과의 평균 오차를 분석한 결과, Cerrobend 선량보상체는 $+3.83\%$, 전자 선량보상체는 $-4.37\%$의 오차를 보였으며, 이는 Cerrobend 선량보상체 제조과정에서의 오차와 절대 선량측정 도구로서 필름이 갖고 있는 한계성을 고려할 때, 선량보상체 기능의 정확도 입증에 타당성 있는 결과로 생각한다.

  • PDF

뇌 정위 방사선수술의 선량 계산을 위한 몬테카를로 시뮬레이션 코드 개발 (Development of Monte Carlo Simulation Code for the Dose Calculation of the Stereotactic Radiosurgery)

  • 강정구;이동준
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.303-308
    • /
    • 2012
  • 뇌정위 방사선수술의 선량계산을 위해 Geant4 기반의 응용 프로그램을 개발 하였다. 선형가속기에서 발생하는 방사선의 스펙트럼을 입력하기 위하여 사전에 실행하여 구한 스펙트럼에 각 에너지별로 구한 가중치를 곱하여 확률밀도를 구하였다. 이를 누적밀도로 변환하여 입력하도록 하였다. 메신저 클래스를 이용하여 다양한 형태의 MLC 조사면을 설정할 수 있도록 하였다. 갠트리와 테이블의 회전을 모사하기 위하여 rotateX와 rotateY라는 회전행렬을 사용하였다. 월드좌표 속에서 갠트리와 테이블을 정의하여 각각 회전을 구현하였다. 실제 환자의 자료는 CT의 dicom 파일에서 픽셀 크기, 매트릭스 크기 등의 정보와 픽셀의 HU를 밀도로 변환한 파일을 생성한 다음 이 파일을 이용 환자의 모델링에 이용 하였다. 환자의 모델링은 팬텀월드 안에 픽셀의 크기에 해당하는 복셀을 정의하고 이 복셀에 픽셀의 밀도와 이 밀도에 해당하는 물질을 할당해주었다.

3D 프린팅 팬텀의 섬광카메라 적용 평가 (Evaluation of Scintillation Camera Applications of 3D Printing Phantom)

  • 박훈희;이주영;김지현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.343-350
    • /
    • 2021
  • 3D printing technology is an additive manufacturing technology produced through 3D scanning or modeling method. This technology can be produced in a short time without mold, which has recently been applied in earnest in various fields. In the medical field, 3D printing technology is used in various fields of radiology and radiation therapy, but related research is insufficient in the field of nuclear medicine. In this study, we compare the characteristics of traditional nuclear medicine phantom with 3D printing technology and evaluate its applicability in clinical trials. We manufactured the same size phantom of poly methyl meta acrylate(PMMA) and acrylonitrile butadiene styrene(ABS) based on the aluminum step wedge. We used BrightView XCT(Philips Health Care, Cleveland, USA) SPECT/CT. We acquired 60 min list mode for Aluminum, PMMA and ABS phantoms using Rectangular Flood Phantom (Biodex, New York, USA) 99mTcO4 3 mCi(111 MBq), 6 mCi (222MBq) and 57Co Flood phantom(adq, New Hampshire, USA). For the analysis of acquired images, the region of interest(ROI) were drawn and evaluated step by step for each phantom. Depending on the type of radioisotope and radiation dose, the counts of the ABS phantom was similar to that of the PMMA phantom. And as the step thickness increased, the counts decreased linearly. When comparing the linear attenuation coefficient of Aluminum, PMMA and ABS phantom, the linear attenuation coefficient of the aluminium phantom was higher than that of the others, and the PMMA and ABS phantom had similar the linear attenuation coefficient. Based on ABS phantom manufactured by 3D printing technology, as the thickness of the PMMA phantom increased, the counts and linear attenuation coefficient decreased linearly. It has been confirmed that ABS phantom is applicable in the clinical field of nuclear medicine. If the calibration factor is applied through further research, it is believed that practical application will be possible.

가임기 여성의 유방암 토모치료 시 난소선량 평가비교 (Evaluation of Ovary Dose for woman of Childbearing age Woman with Breast cancer in tomotherapy)

  • 이수형;박수연;최지민;박주영;김종석
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.337-343
    • /
    • 2014
  • 목 적 : 최근 시행되고 있는 가임기 여성의 유방암 토모치료 시 치료영역 외에서 발생되는 산란 및 누설에 의한 난소산란선량을 측정하여 평가하고자 한다. 대상 및 방법 : 인체모형팬텀(Aldorson Rando phantom, USA)을 대상으로 전산화단층영상 2.5 mm 획득 후, Tomotherapy Planning station(Tomotherapy, Inc, USA)을 이용하여 좌측 유방암 환자의 토모테라피 치료계획(Tomotherapy Helical & Tomotherapy Direct)을 수립하였다. 난소의 산량 선량 측정을 위한 측정 지점은 치료계획면적의 30 cm 아래 떨어진 골반의 좌우 위치로 직경 1.5 mm, 길이가 12mm인 저에너지용 보상필터가 들어있는 종류의 유리선량계 (GD-352M, ASAHI TECHNO GLASS CO, Japan)를 이용하여 각 5회씩 측정하여 평균하였으며, 선형지수-선량반응모델을 이용한 장기등가선량(organ equivalent dose: OED)으로 평가하였다. 결 과 : 토모 Helical 및 토모 Direct의 두 가지 방식으로 측정된 난소의 산란선량은 좌측 난소부위가 각각 평균 $64.94{\pm}0.84mGy$, $37.64{\pm}1.20mGy$이고, 우측 난소부위가 평균 $64.38{\pm}1.85mGy$, $32.96{\pm}1.11mGy$로 나타났다. 이는 토모치료 시 비교적 모니터 단위(MU)가 크고 조사 시간이 긴 토모Helical 방식이 토모Direct에 비하여 측정된 산란선량의 양이 보다 약 1.8배 높은 경향을 보였다. 결 론 : 가임기 여성의 유방암 토모테라피 시 발생하는 좌우측 난소의 산량선량은 ICRP 권고 선량이하로, 불임 및 2차 암 발생에 대한 우려 수준은 현저히 낮지만 향후 유방암 발생 연령층이 낮아지고, 토모테라피와 같이 고정밀 영상유도장치를 이용한 방사선치료가 발달할수록, 가임기 여성 환자의 난소산란선량에 대한 임상적 추적조사가 더욱 필요할 것으로 사료된다.

컴퓨터 단층촬영의 조직간 밀도차이에 대한 노이즈 영향 (Effect of Noise on Density Differences of Tissue in Computed Tomography)

  • 양원석;손정민;천권수
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.403-407
    • /
    • 2018
  • 현재 우리나라의 암 사망률 중 가장 높은 암은 폐암이며 조기발견이 어려운 대표적인 암이다. 조기 발견을 위하여 저선량 흉부 CT를 활용하고 있으며 이는 일반 흉부 X선 사진에 비해 약 3배 정도 폐암 진단율이 높다. 그러나 저선량 흉부 CT는 영상 해상도가 크게 저하될 뿐 아니라 신호가 약해 잡음에 민감한 단점이 있다. 또한 공기로 채워져 있는 폐는 밀도가 낮은 장기로 잡음의 유무가 암의 조기 진단에 영향을 크게 줄 수 있다. 본 연구는 Visual C++을 이용하여 2.0밀도를 가진 큰 원 내부에 물의 밀도인 1.0을 값을 갖는 원을 설정하고 그 안에 각각 밀도가 다른 작은 5개의 원을 수학적 팬텀화하고 가우시안 노이즈를 1%, 2%, 3%, 4% 각각 발생시켜 밀도차에 의한 노이즈의 영향을 평균 값과 표준편차 값, 신호대잡음비(SNR)로 확인하였다. 1% 노이즈 발생 시 큰 원과 작은 원의 밀도차가 가장 큰 영역의 SNR은 4.669로 노이즈의 영향이 작게 나타났으며 밀도차가 가장 낮은 영역의 SNR은 1.183으로 노이즈의 영향이 크게 나타났다. 또한 음의 밀도차에서도 같은 결과 값을 얻었으며 양의 밀도와 음의 밀도 모두 큰 원과 작은 원의 밀도차이가 높은 경우에 SNR 값이 높은 것을 확인 할 수 있다. 화질 또한 밀도차가 크게 나타났을 때 확연하게 육안으로 확인할 수 있었으며 노이즈레벨이 증가하는 경우에는 SNR이 감소하여 잡음의 영향이 크게 나타났다. 이는 밀도차가 적은 장기 또는 암과의 밀도가 비슷한 영역의 장기는 노이즈 영향이 크게 나타날 것이며 노이즈의 발생 확률에 따른 밀도차이의 영향이 진단에 영향을 끼칠 것으로 사료된다.

여닫이형 방사선 치료의 검증: 잔여 움직임의 선량적 영향 (Verification of Gated Radiation Therapy: Dosimetric Impact of Residual Motion)

  • Yeo, Inhwan;Jung, Jae Won
    • 한국의학물리학회지:의학물리
    • /
    • 제25권3호
    • /
    • pp.128-138
    • /
    • 2014
  • 여닫이형 방사선 치료에서, 잔여 움직임으로 인하여 방사선은 실직적인 질병의 부위 뿐만이 아니라 주변 정상조직까지 투여 되도록 되어 있다. 비록 표적이 방사선 투여 중 움직이지만, 방사선이 최소한도로 실질적인 부위 (임상적 표적 체적)에 조사되기를 원한다. 본 연구의 목적은 여닫이형 치료에 있어서 방사선이 실질적인 표적에 투여되는지를 검증하고, 여닫이 범위, 움직임의 정도 및 임상적 표적체적의 크기의 변화에 따라, 표적및 주변 조직에 투여되는 방사선의 경향을 연구하는 데 있다. 이 목적을 달성하기 위하여, 실험 및 이론적인 연구를 고안하여 수행하였다. 직육각형 및 피라미드형의 표적 체적을 내포하는 팬텀을 만들어 움직이며 4차원 영상을 얻었다. 여러 여닫이 범위를 얻어진 영상에 적용하여 치료계획용 내부표적(표적체적 및 내부 움직임범위포함)을 만들었다. 직육각형 표적에는 전통적인 치료계획을 그리고 피라미드형 표적에는 세기 변조형 치료계획을 세웠다. 평판형 다이오드에 치료계획에서 얻어진 여닫이형 방사선을 수직으로 조사하여 실험적으로 선량평가를 수행하였고 또한 움직이는 상황에서 선량투여를 전산적으로 모사하였다. 본 연구는 두 표적에 대한 반음영 영역의 확장 및 움직임으로 인하여 방해 받았으나 확실하게 수행된 표적 선량투여 그리고 주변 조직에 투여된 상당량의 선량등을 수반하는 잔여움직임의 영향을 정량적으로 그리고 해석적으로 분석하였다. 선량-체적 히스토그램 분석에 따르면, 내부표적에는 여닫이 범위 또는 움직임 정도가 감소함에 따라 또한 표적체적이 증가함에 따라 선량이 증가함을 보였고, 내부 움직임 범위에 해당하는 체적에 대하여는 여닫이 범위 또는 움직임 정도가 감소함에 따라 선량이 증가하였고, 마지막으로 주변 정상조직에 대하여는, 내부 움직임 범위와는 반대의 경향을 보였다. 본 연구는 잔여움직임의 영향에 대하여 확실한 이해를 주었고 호흡행태가 재생되는한 불연속적인 투여과 표적의 움직임에도 불구하고 여당이형 방사선 치료는 안전함을 입증하였다. 본연구에서 수반된 절차와 전산적 모델은 여닫이형 치료의 시작점 검증, 주기적인 품질관리 및 환자별 검증에 사용될 수 있다. 환자별 영상에 선량을 재구성하는 방향으로 추후 연구가 필요하다.

두 경부 암 환자의 방사선치료 시 자체 제작한 고정 기구 유용성의 고찰 (Implementation of Man-made Tongue Immobilization Devices in Treating Head and Neck Cancer Patients)

  • 백종걸;김주호;이상규;이원주;윤종원;조정희
    • 대한방사선치료학회지
    • /
    • 제20권1호
    • /
    • pp.1-9
    • /
    • 2008
  • 목 적: 두 경부 암 방사선치료 시 구강 구조물 내에 정확한 자세 재현성을 유지하는 것은 환자에게 편안함을 주는 동시에 최적화된 선량분포를 얻는데 매우 중요하다. 이 연구의 목적은 방사선치료 시 재현성을 유지하고 구강 내부의 공기와 조직계면 사이의 선량을 보정하기 위해 각 환자의 고정 기구를 자체 제작하였으며, 이를 기존의 고정 기구와 비교 분석하는데 그 목적이 있다. 대상 및 방법: 치과 환자의 구강 조형물 제작 시 사용되는 알지네이트(alginate; AROMA FINE DF III normal set, japan)와 퍼티 (putty; aquasil soft putty/regular set, germany)를 이용하여 각 환자의 구강 구조와 동일한 고정 기구를 제작 하였다. 방사선 치료 시 재현성을 평가를 위해 자체 제작한 고정 기구를 이용하여 컴퓨터 단층 촬영 시와 동일한 자세로 5회 Linac-gram을 촬영하고 분석하였다. 자체 제작한 고정 기구의 선량 안정성을 검증하기 위하여 공기, 물, 알지네이트 그리고 퍼티를 삽입할 수 있는 아크릴 팬텀을 제작하였다. 실험은 두 가지 조사면적(3$\times$3 cm, 5$\times$5 cm)에 대해 단일 조사를 통해 이루어졌고 방사선 치료 계획 장비(Pinnacle ver.7.6c, Philips, USA)에 의해 계산된 선량과 EBT 필름을 사용한 측정된 선량을 비교 분석하였다. 결 과: 자체 제작한 고정 기구의 재현성 검증을 위한 조사야 확인 영상 확인 결과 기존의 고정 기구를 사용한 경우에 비해 알지네이트와 퍼티를 이용한 고정 기구는 4배 이상의 우수한 재현성을 보였고, 방사선 치료 시 환자의 불편함을 해소 할 수 있었다. 방사선 치료 계획 장비를 이용한 계산된 계면선량은 공기일 때 3$\times$3 cm, 5$\times$5 cm에서 각각 7.87%, 0.56%로 나타났으며 EBT (international specialty products, USA)필름을 사용한 측정된 계면선량은 36.5%, 11.8%로 EBT 필름을 사용한 측정된 계면선량이 크게 나타났다. 결 론: 두 경부 암 환자의 방사선 치료 시 구강 내 구조물의 자세 재현성을 유지하기 위하여 알지네이트와 퍼티를 이용하여 자체 제작한 고정 기구는 기존의 고정 기구 보다 매우 우수한 재현성을 유지 할 수 있었으며, 소 조사면에 대한 방사선 치료 계획 시 치료 계획 장비의 선량 계산 알고리즘의 한계로 인한 구강 내 계면선량의 감소를 보정해 최적의 선량분포를 얻을 수 있었다.

  • PDF