• Title/Summary/Keyword: CT-26

Search Result 696, Processing Time 0.023 seconds

A Comparative Study on the Lens Dose According to the Change of Shielding Material Used in Brain Computed Tomography (Brain CT에서 차폐 재료 변화에 따른 수정체 선량 비교 연구)

  • Hwang, Incheol;Shin, Woonjae;Gang, Eunbo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.31-37
    • /
    • 2015
  • The cases of radiographic inspection for medical diagnosis in Korea have been continuously increasing year after year, which pays particularly more attention to CT which occupies over the half of medical radiation exposure. To find an effective alternative for reducing radiation exposure, the researchers conducted comparative experiments using some shields made of bismuth, aluminum 6mm, and silicone 22mm. These shielding materials have been used to reduce the entrance surface dose (ESD) on lenses, maintaining the CT number, noise, and uniformity in brain CT scanning which forms the largest part in CT scanning these days. These experiments showed that the doses in the spiral scan parallel to IOML and the conventional scan in Bismuth were 26.41% and 17.52%, respectively; in Aluminum 18.24% and 9.39%; in Silicone 19.47% and 14.39% lower than compared with those in the cases without any shields. In the items of the CT number, noise, and uniformity, the bismuth shield satisfied exceedingly the standards of the phantom image test while aluminum and silicone were within. To keep the graphic quality and get good shielding effect, we recommend the silicone shield which can be manufactured and purchased with ease.

Anti-cancer and Immuno-stimulatory Effects of Vegetable Soup on CT26 Cancer Cells (야채수프의 CT26 암세포에 대한 항암 및 면역 증강 효과)

  • Lim, Hyun Jung;Park, Sang Min;Jun, Hyeong-Kwang;Ryu, Gi-Hyung;Park, Youn-Je
    • Journal of the Korean Society of Food Culture
    • /
    • v.32 no.5
    • /
    • pp.453-464
    • /
    • 2017
  • Vegetable soup has been reported to have anti-inflammatory, anti-oxidative and anti-cancer effects. In this study, five kinds of vegetable soup were developed using a new manufacturing process and compositional changes in raw material, and anti-cancer and immuno-stimulatory activities were evaluated. Cytotoxicity tests based on MTT assay revealed that all vegetable soups had strong inhibitory effects against CT26 mouse colon cancer cells, with soups including Solomon's seal being most effective based on comparison of $IC_{50}$ values. Apoptosis in response to vegetable soup was occurred by 3-5 fold on cancer cells compared to normal cells. Mouse splenocytes increased by 266-541% in response to addition of vegetable soup in an in vitro proliferation experiment. In co-culture with splenocytes and CT26 cancer cells, splenocytes increased by more than 280% in every vegetable soup treatment, while cancer cells decreased by about 60% and cytokines such as $IFN- {\gamma}$ and IL-12 were secreted from splenocytes in high levels only in response to vegetable soup including Solomon's seal. In conclusion, all vegetable soups developed in this study had anti-cancer effects, and vegetable soup including Solomon's seal showed the strongest anti-cancer and immuno-stimulatory effects. These results suggest that functionality of vegetable soup could be increased by changes in manufacturing processes and raw materials composition.

Effect of Korean Red Ginseng extract on colorectal lung metastasis through inhibiting the epithelial-mesenchymal transition via transforming growth factor-β1/Smad-signaling-mediated Snail/E-cadherin expression

  • Kee, Ji-Ye;Han, Yo-Han;Mun, Jeong-Geon;Park, Seong-Hwan;Jeon, Hee Dong;Hong, Seung-Heon
    • Journal of Ginseng Research
    • /
    • v.43 no.1
    • /
    • pp.68-76
    • /
    • 2019
  • Background: In colorectal cancer (CRC), 40-60% of patients develop metastasis. The epithelial-mesenchymal transition (EMT) is a pivotal and intricate process that increases the metastatic potential of CRC. The aim of this study was to investigate the effect of Korean Red Ginseng extract (RGE) on colorectal metastasis through inhibition of EMT and the metastatic abilities of CRC cells. Methods: To investigate the effect of RGE on the metastatic phenotypes of CRC cells, CT26 and HT29 cells were evaluated by using an adhesion assay, a wound-healing assay, an invasion assay, zymography, and real-time reverse transcription-polymerase chain reaction. Western-blot analysis was conducted to elucidate the molecular mechanisms of RGE, which showed an inhibitory effect on the transforming growth factor-${\beta}1$ ($TGF-{\beta}1$)-induced EMT in HT29 cells. Additionally, the antimetastatic effect of RGE was evaluated in a mouse model of lung metastasis injected with CT26 cells. Results: RGE decreased the adhesion and migration ability of the CT26 cells and TGF-${\beta}1$-treated HT29 cells. The invasion ability was also reduced by RGE treatment through the inhibition of matrix metalloproteinase-9 expression and activity. Moreover, RGE suppressed the TGF-${\beta}1$-induced EMT via TGF-${\beta}1$/Smad-signaling-mediated Snail/E-cadherin expression in HT29 cells and lung tissue in CT26 tumor-bearing mice. Conclusion: Our results demonstrated that RGE inhibited colorectal lung metastasis through a reduction in metastatic phenotypes, such as migration, invasion, and the EMT of CRC cells.

Acceptance Test and Clinical Commissioning of CT Simulator

  • An, Hyun Joon;Son, Jaeman;Jin, Hyeongmin;Sung, Jiwon;Chun, Minsoo
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.160-166
    • /
    • 2019
  • This study examined the clinical use of two newly installed computed tomography (CT) simulators in the Department of Radiation Oncology. The accreditation procedure was performed by the Korean Institute for Accreditation of Medical Imaging. An Xi R/F dosimeter was used to measure the CT dose index for each plug of the CT dose index phantom. Image qualities such as the Hounsfield unit (HU) value of water, noise level, homogeneity, existence of artifacts, spatial resolution, contrast, and slice thickness were evaluated by scanning a CT performance phantom. All test items were evaluated as to whether they were within the required tolerance level. CT calibration curves-the relationship between CT number and relative electron density-were obtained for dose calculations in the treatment planning system. The positional accuracy of the lasers was also evaluated. The volume CT dose indices for the head phantom were 22.26 mGy and 23.70 mGy, and those for body phantom were 12.30 mGy and 12.99 mGy for the first and second CT simulators, respectively. HU accuracy, noise, and homogeneity for the first CT simulator were -0.2 HU, 4.9 HU, and 0.69 HU, respectively, while those for second CT simulator were 1.9 HU, 4.9 HU, and 0.70 HU, respectively. Five air-filled holes with a diameter of 1.00 mm were used for assessment of spatial resolution and a low contrast object with a diameter of 6.4 mm was clearly discernible by both CT scanners. Both CT simulators exhibited comparable performance and are acceptable for clinical use.

Acclimation temperature influences the critical thermal maxima (CTmax) of red-spotted grouper

  • Rahman, Md Mofizur;Lee, Young-Don;Baek, Hea Ja
    • Fisheries and Aquatic Sciences
    • /
    • v.24 no.7
    • /
    • pp.235-242
    • /
    • 2021
  • The present study investigated the critical thermal maxima (CTmax) of red-spotted grouper, Epinephelus akaara under different acclimation temperatures (Tacc). Fish were acclimated at 24℃, 28℃, and 32℃ water temperature for 2 weeks. Water temperature was increased at a rate of 1℃/h and CTmax level was measured following the critical thermal methodology (Paladino et al., 1980). The results showed that CTmax values of E. akaara were 35.61℃, 36.83℃, and 37.65℃ for fish acclimated at 24℃, 28℃, and 32℃, respectively. The acclimation response ratio (ARR) was 0.26. The CTmax values were significantly correlated with body size. Collectively, it is said that the CTmax value of red-spotted grouper can be affected by different adaptation temperature (24℃, 28℃, and 32℃) and the fish acclimated to a higher temperature has a higher CTmax level. Besides, the CTmax value of 35.61℃-37.65℃ indicating the upper thermal tolerance limit for E. akaara under different Tacc (24℃, 28℃, and 32℃). Understanding the thermal tolerance of E. akaara is of ecological importance in the conservation of this species.

The diffusion and policy options of the diagnostic imaging technologies in Korea (의사결정나무 분석을 사용한 고가의료장비의 다빈도 사용 특성 분석)

  • Choi, Yoon Jung;Kwak, Minjung;Yoon, Min
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.1
    • /
    • pp.179-185
    • /
    • 2015
  • The cost of advanced medical technologies is commonly considered to be a major factor in the overall escalation of expenditures on health. The use of computed tomography (CT) scanning has increased dramatically over the past decade. CT has been rapidly adopted, despite their high cost. The aim of this study is to analysis the increasing factor of the frequency of the CT, using the decision tree model. Finally, we propose the effective policy option of diagnostic imaging technology in Korea.

Synovial Sarcoma of the Anterior Chest Wall: A Case Report (앞가슴벽에 생긴 윤활막육종: 증례 보고)

  • Mingook Kim;Seung Eun Lee;Joon Hyuk Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1227-1233
    • /
    • 2020
  • Synovial sarcoma is a malignant soft tissue tumor that usually involves the extremities, particularly near the knees; a synovial sarcoma originating in the chest wall is extremely rare. We describe a 26-year-old woman diagnosed with a synovial sarcoma originating in the chest wall, based on CT and MRI findings. Contrast-enhanced CT images revealed a small, well-defined enhancing mass with calcification, in the subpleural area. This lesion was initially diagnosed as a benign tumor; however, the patient developed sudden severe pain with spontaneous bleeding and hemothorax, suggesting the possibility of malignancy. MRI revealed a multilobulated mass with a fluid-fluid level, which characterizes a synovial sarcoma.

Correlation of Pre-treatment FDG Uptake to Therapeutic Response and Relapse in Patients with Small Cell Lung Cancer (소세포폐암의 치료전 FDG섭취와 치료반응 및 재발과의 연관성)

  • Seo, Young-Soon;Kwon, Seong-Young;Jeong, Shin-Young;Song, Ho-Chun;Min, Jung-Joon;Kim, Kyu-Sik;Kim, Young-Chul;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.538-545
    • /
    • 2007
  • Purpose: We evaluated correlation of $^{18}F$-FDG uptakes, therapeutic response and relapse in pre-treatment $^{18}F$-FDG PET/CT in patients with SCLC. Materials and methods: We included 26 patients with pathologically proven small cell lung cancer. Total 102 lesions (26 lungs, 69 lymph nodes and 8 metastatic lesions) were evaluated. All patients underwent $^{18}F$-FDG PET/CT for staging. The maxSUV was used as a parameter of $^{18}F$-FDG uptake. The patients were divided into responders and non-responders according to response criteria on chest CT scan after 3 cycles of chemotherapy. We compared maxSUV between two groups by using independent t-test. To access correlation with $^{18}F$-FDG uptake and relapse, maxSUV and interval time to relapse was analyzed by correlation analysis. The cutoff value of maxSUV was evaluated by ROC curve. Results: Twelve-one patients (81%) were responders and five patients were non-responders on follow-up chest CT scan. The mean maxSUV of main lung lesions in responders and non-responders were $14.15{\pm}3.72$ and $9.17{\pm}2.15$, respectively. The maxSUV in the responders was significantly lower than that in non-responders (p<0.05). According to ROC curve, point of cut that predicts therapeutic response was 8.98 with 100% sensitivity and 57% specificity. The correlation analysis between $^{18}F$-FDG uptakes and interval time to relapse showed a significant negative correlation (p<0.05, r=-0.757). Conclusion: The pre-treatment $^{18}F$-FDG uptake of responders was significantly lower than that of non-responders. Patients with high $^{18}F$-FDG uptake in pre-treatment $^{18}F$-FDG PET/CT relapse earlier.

Comparative study of 2-nitroimidazole-fluorophore-conjugated derivatives with pimonidazole for imaging tumor hypoxia

  • Seelam, Sudhakara Reddy;Hong, Mi Kyung;Lee, Yun-Sang;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.2
    • /
    • pp.101-112
    • /
    • 2019
  • Herein, 2-nitroimidazole-fluorophore conjugates were synthesized by linking 2-nitroimidazole and FITC or RITC via thiourea bonds. The prepared derivatives were stable for 2 h in Dulbecco's modified Eagle's medium (DMEM) at 37 ℃. The novel conjugates were studied for their in vitro uptake under hypoxic conditions using U87MG and CT-26 cell lines, showing significantly higher uptakes in hypoxic than normoxic cells. Immunohistochemical analysis confirmed hypoxia in U87MG and CT-26 xenografted tumor tissues. Moreover, the prepared conjugates were evaluated by in vivo experiments after intravenous injection in U87MG and CT-26 xenografted mice. Hypoxia was confirmed by immunohistochemistry of the prepared derivatives with co-injected pimonidazole. Confocal microscopy of the prepared derivatives showed strong fluorescence in hypoxic tumor tissues correlated with the pimonidazole distribution. This suggested that the 2-nitroimidazole-fluorophore conjugates are promising optical imaging probes for tumor hypoxia and are promising substitutes for pimonidazole immunohistochemistry, which requires a multi-step procedure of incubation involving antibody, second antibody, dye, hydrogen peroxide, and multiple washing steps.