• 제목/요약/키워드: CT scan time

검색결과 235건 처리시간 0.023초

흉부CT 검사 시 HRCT 영상 재구성의 유용성 (Usefulness Evaluation of HRCT using Reconstruction in Chest CT)

  • 박성민;김긍식;강성민;유병규;이기배
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

PET/CT 검사에서 동영상 홍보물을 통한 의료서비스 향상에 관한 연구 (A Study on the Improvement for Medical Service Using Video Promotion Materials for PET/CT Scans)

  • 김우현;김정선;고현수;성지혜;이정은
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.30-35
    • /
    • 2013
  • 의료서비스의 만족도를 향상시키기 위한 방안으로 체감 대기시간 단축과 정확한 의료정보 제공, 검사의 정확도 등이 긍정적인 반응을 보여주고 있다. 이와 같은 방안에 동영상 홍보물이 유용성이 있는지 평가하였으며, 휴대용 DVD플레이어를 구입하여 검사 전 개인적으로 동영상을 시청하도록 한 방법이 서비스 만족도 향상에 도움이 되는 것으로 조사되었다. 체감대기시간 단축에 의한 만족도 향상은 예약시간보다 지연 되는 경우 보다 효과적이며, 현재 제공되고 있는 동영상의 활용도 향상을 위한 홍보를 적극적으로 시행한다면 정확한 의료정보 제공에 의한 만족도 역시 향상될 것이다. 방사성의약품 투여 후 표준섭취시간을 초과하는 시간대 중 가장 많은 부분을 차지하는 1~~3분대를 최소화하기 위해 약 7분 정도의 홍보 동영상을 제공한 결과 미준수 건수가 2.3% 감소하였으며, 이는 정확한 검사를 제공하여 고객의 만족도를 높일 수 있다. 향후 동영상 제공에 대한 홍보를 적극적으로 시행하고 검사 전 개별적으로 동영상을 시청할 수 있도록 휴대용 DVD 플레이어를 제공할 수 있는 구조적인 시스템이 갖춰진다면 의료서비스에 의한 고객 만족도 향상에 기여하리라 생각된다.

  • PDF

Bolus tracking 기법을 이용한 복부 CT 검사 시 조영제 도달시간에 따른 환자 피폭선량 감소에 관한 연구 (A Study on the Reduction of Patient's Exposure Dose according to the Arrival Time of Contrast Media in Abdominal CT Scan using Bolus Tracking Technique)

  • 이승용;한동균
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.93-100
    • /
    • 2021
  • 본 연구는 bolus tracking 기법을 이용한 복부 CT 검사 시 환자 피폭선량에 영향을 미치는 인자를 알아보고 인자를 통해 지연시간을 조절하여 추후 bolus tracking 기법을 이용한 복부 CT 검사 시 환자의 방사선 피폭선량을 감소시키는 목적이 있다. 실험은 두 가지로 나누어 실시하였고, 첫 번째 실험은 환자 300명을 대상으로 하였고 남자 188명, 여자 112명, 평균나이는 58±12.18세(19~85세)이었다. 대상자의 신장, 체중, 체질량지수, 수축기혈압, 이완기혈압, 심박동수에 따른 조영제 도달시간(Arrival time)을 측정하였고, 영향 인자 그룹별 도달시간의 평균값을 기준으로 영향 인자에 따른 지연시간을 정하여 두 번째 실험에 적용하였다. 두 번째 실험은 첫 번째 실험 대상자 중 추적검사를 시행하는 150명(남자 100명, 여자 50명)을 대상으로하였고, 영향 인자에 따른 지연시간을 적용하여 적용 전·후 선량을 비교하였다. 첫 번째 실험 결과 조영제 도달시간과 심박동수가 관계가 있었고, 두 번째 실험 결과 심박동수에 따른 지연시간 적용 전·후 CTDIvol와 DLP 의 평균선량은 남자 4.98 mGy, 5.33 mGy·cm 감소하였고, 여자 3.53 mGy, 3.88 mGy·cm 감소하였다. 따라서 bolus tracking 기법을 이용한 복부 CT 검사 시 환자의 심박동수에 따른 지연시간 적용으로 방사선 피폭선량을 감소시킬 수 있다.

64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소 (Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols)

  • 김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.299-306
    • /
    • 2009
  • MDCT의 시간분해능 향상과 등방성 해상능(isotrophic resolution) 영상의 획득, 그리고 지능적인 심전도 동조를 바탕으로 하여 심혈관 질환의 효과적인 진단검사로 인정받고 있는 후향적 심전도 동조화(retrospective ECG gating) 하의 coronary CT angiography는 상대적으로 많은 환자선량을 제공함으로 인해 우수한 진단방법으로서의 장점을 반감시키고 있다. 이에 각 장치 제조사에서는 환자선량을 감소시키는 방법의 연구가 활성화되어 왔으며, 이의 일환으로 지능적인 cardiac dose modulation 기술과 전향적 심전도 동조화(prospective ECG gating)를 사용한 sequential scan이 도입되고 있다. 이에 본 연구에서는 64 채널 MDCT에서 54 kg, 163 cm인 여성 인체모형팬텀을 대상으로 하고 형광유리선량계를 사용하여 후향적 심전도 동조화 하의 coronary CT angiography 프로토콜에서 환자선량의 정량적 평가와 환자선량 감소를 위해 본원에서 선택적으로 적용하고 있는 5가지 검사 프로토콜을 적용하였을 경우의 effective dose와 중요 부위의 organ dose를 측정 비교하여 다음과 같은 결과를 얻었다. 1) Dose modulation없이 120 kVp와 210 mAs의 노출조건으로 retrospectively ECG gated helical scan으로 시행한 conventional coronary CT angiography 프로토콜의 effective dose는 17.8 mSv였으며, 심장의 organ dose는 103.8 mGy였다. 2) 관전압을 120 kVp에서 100 kVp로 낮추었을 경우 effective dose는 11.0 mSv로 conventional coronary CT에 비해 38.2%가 감소하였으며, 심장은 67.3 mGy로 45.2%가 감소하였다. 3) Cardiac dose modulation을 적용한 경우 effective dose는 13.3 mSv로 conventional coronary CT에 비해 25.3%가 감소하였으며, 심장은 80.0 mGy로 22.9%가 감소하였다. 4) 100 kVp의 저관전압과 cardiac dose modulation을 적용한 경우 effective dose는 8.1 mSv로 conventional coronary CT angiography에 비해 54.5%가 감소하였으며, 심장은 49.5 mGy로 52.3%가 감소하였다.

  • PDF

TOF 기법을 이용한 PET/CT 검사에서 적정 스캔 시간에 대한 정량적 평가 (Quantitative Evaluation on Optimal Scan Time of PET/CT Studies Using TOF PET)

  • 문일상;이홍재;김진의;김현주
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.34-37
    • /
    • 2012
  • $^{18}F$-FDG 검사 시 한 bed 당 적정 스캔 시간을 정량 평가하기 위하여 Philips사 TF 64 PET/CT를 사용하였다. Phantom 실험과 환자를 대상으로 다양한 스캔 시간을 적용하며 평가를 하여 최적의 스캔 시간을 알고자 하였다. 20초 간격으로 총 5회의 서로 다른 bed 당 스캔 시간을 NEMA IEC body phantom과 환자들에게 적용하여 $^{18}F$-FDG 영상을 획득하였다. Phantom 실험의 경우 관심영역과 background의 방사능비를 8:1로 했다. 관심영역과 background 영역의 표준섭취계수(SUV)와 대조회복계수(CRC)가 계산되었다. 환자를 대상으로 한 연구에서는 평균$444{\pm}74$ MBq의 $^{18}F$-FDG가 환자에게 주사되었고 20명의 환자, 38개의 병소부위에서 표준섭취계수가 측정되었다. Background noise는 background 부분의 표준편차를 평균으로 나누어 계산되었다. Phantom 실험에서 두 그룹 (LT-60 [<60 sec]과 GT-60 [${\geq}60$ sec])을 비교한 결과 LT-60 그룹의 표준섭취계수(SUV)와 대조회복계수(CRC)가 (H1: 14.2 and 7.3, H2: 11.4 and 7.8, H3: 4.9 and 3.2), GT-60 그룹(H1: 8.9 and 2.8, H2: 8.2 and 5.0, H3: 2.0 and 1.6)에서 보다 높은 변이율을 보였다. 이는 한 bed 당 스캔시간이 60 sec 이상일 때 안정적인 표준섭취계수와 대조회복계수를 나타내는 것을 의미한다. 환자를 대상으로 한 연구에서 역시 표준섭취계수(SUV)와 대조회복계수(CRC)가 LT-60 그룹에서 높은 변이율을 보였다. PET/CT 영상에서 background noise는 bed 당 스캔시간이 증가함에 따라 감소하는 것으로 나타났다. 그리고 60 sec 이하 그룹에서는 높은 background noise로 인하여 높은 SUV와 CRC 변이율을 보였다. 따라서 PET/CT 영상의 질을 고려할 때 1 bed 당 스캔시간은 최소 60 sec 이상이어야 한다.

  • PDF

Assessment of Breast Volume Change after Transverse Rectus Abdominis Myocutaneous Flap

  • Park, Sang Uk;Shim, Jeong Su
    • Archives of Plastic Surgery
    • /
    • 제39권6호
    • /
    • pp.631-635
    • /
    • 2012
  • Background The evaluation of a breast after breast reconstruction depends on a surgeon's subjective criteria. We used computed tomography (CT) scans to obtain an objective evaluation of the postoperative results by measuring the breast volume of patients who had undergone breast reconstruction using pedicled transverse rectus abdominis myocutaneous (TRAM) flaps. This research will help in the objective postoperative evaluation of reconstructed breasts, and also in the preoperative flap size designs. Methods A total of 27 patients underwent breast reconstruction using pedicled TRAM flaps after mastectomy from September 2007 to July 2010. Of these, 10 patients who were followed up and underwent CT scans 2 or more times during the follow-up period were included in this study. We evaluated the change in breast volume over time using CT scans, and the interval breast volume change between CT scans. Results All of the 10 patients' reconstructed breasts showed a volume decrease over time. The breast volume changes in the intervals between CT scans were as follows: 5.65% decrease between the first CT and second CT scan, 2.3% decrease between the second CT and third CT scan, (statistically significant) and 1.89% decrease between the third CT and forth CT scan. (not statistically significant). Conclusions This research shows the possibility of objectively evaluating the postoperative breast volume changes. The findings will be helpful in designing the size of TRAM flaps to use on defects after mastectomy. Based on these results, we should also closely observe the reconstructed breast volume for at least 2 years.

자발성 뇌실질내 출혈 환자에서 혈종 증가의 위험 인자에 대한 분석 (Analysis of the Risk Factors of Hematoma Enlargement in Patients with Spontaneous Intracerebral Hemorrhage)

  • 이용묵;고현송;염진영;김성호;송시헌;김윤
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권4호
    • /
    • pp.437-442
    • /
    • 2001
  • Objective : The purpose of this study was to evaluate the risk factors of hematoma enlargement in patients with spontaneous intracerebral hemorrhage(ICH). Methods : A series of 214 ICH patients diagnosed by brain CT scan in our neurosurgery department from June 1995 to July 1998 were reviewed with clinical status, past medical histories, laboratory findings, CT findings and prognosis. Results : In 27 patients(12.6%), the second CT scan showed an enlarged hematoma. Age, sex, and site of hematoma were not related to hematoma enlargement. A long interval(>6 hours) between the onset and the 1st CT scan strongly reduced the incidence of hematoma enlargement. The incidence of hematoma enlargement significantly increased in patients with previous history of hypertension, cerebral infarction and ICH. This analysis also demonstrated the following independent factors predisposed to hematoma enlargement : initial high systolic blood pressure, high serum total protein, low serum albumin, low serum sodium, prolonged prothrombin time(>14 sec) and activated partial thromboplastin time(>29.5 sec), irregular hematoma shape, and combined intraventricular hemorrhage. Prognosis in the group of hematoma enlargement showed high mortality(48.1%) and poor outcome. Conclusion : Patients with previous history of hypertension, cerebral infarction and ICH, and with high systolic blood pressure, prolonged coagulation time, irregular hematoma shape and intraventricular hemorrhage in CT scan should be observed carefully. And, early surgical therapy of large hematoma and meticulous control of blood pressure may decrease the mortality and morbidity in patients with spontaneous ICH.

  • PDF

PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가 (The Research of Comparison Evaluation on the Decline in Artifact Using Respiratory Gating System in PET-CT)

  • 김진영;이승재;정석;박민수;강천구;임한상;김재삼
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.63-67
    • /
    • 2015
  • 환자의 호흡에 의해 발생되는 인공물의 감소를 위한 다양한 방법들 중 호흡동조 시스템(이하 Q static scan)과 비교하여 CTAC Shift 보정방법, Additional scan(추가 검사방법)을 평가해보고자 한다. 본 연구는 2015년 2월에서 5월까지 본원을 내원한 환자들 중 영상에서 호흡에 의해 인공물이 발생한 환자 10명을 대상으로 진행하였으며 장비는 PET-CT Discovery 710 (GE Healthcare, MI, USA)과 호흡동조 시스템인 Varian사의 RPM system을 사용하였다. 환자는 24시간동안의 운동금지, 12시간동안 커피와 담배 금지, 8시간동안 금식을 한 후 충분한 수분을 섭취하고 도착시 혈관확보를 한 후 혈당 체크를 진행하며 $^{18}F$-FDG를 kg당 5.18 Mbq을 주사하였다. 그 후 1시간동안 안정을 취하고, 배뇨 후 검사를 진행하였다. CT조건은 관전압 120 kVp와 관전류 60 mAs, DFOV는 70 cm, Matrix size는 $192{\times}192$으로 모두 동일하게 진행하였다. 인공물이 발생한 영상을 기준으로 Additional scan, 호흡동조 시스템을 연동한 Q static scan, CTAC Shift 보정방법을 통해 영상화하였다. 각각의 영상에서 인공물의 감소를 비교하였으며, 육안적 평가와 SUVmax의 변화를 측정하였다. 인공물이 발생한 Whole body scan(WBS)을 통해 얻은 영상 대비 CTAC Shift 보정방법을 통해 얻은 영상의 경우 12~56%, Q static scan 영상은 17~54%, Additional scan 영상은 -27~46%의 변화율을 보였다. Blind Test에서는 CTAC Shift 보정영상이 4점으로 가장 높은 점수를 얻었고 Q static scan 영상이 3.5점, Additional scan 영상이 3.4점의 점수를 얻었다. Oneway ANOVA 검정을 통해 기준이 된 WBS scan 영상과 세 가지 Scan방법간에 유의한 차이를 보였으며(p<0.05) 세 가지 Scan방법간에는 유의한 차이를 보이지 않았다(p>0.05). 그러나 Blind test에서는 세 가지 Scan방법간의 유의한 차이를 보였다. Additional scan과 Q static scan은 CTAC Shift 보정 방법보다 시간이 소요되며 환자에게 CT 재촬영에 의한 과피폭이 우려되며 Q static scan은 호흡의 기복이 심하거나 통증으로 인해 호흡 주기가 불규칙한 환자의 경우 적용하기에 어려움이 있다. CTAC Shift 보정 방법의 경우 제한적으로 보정이 가능하며 그 범위 또한 제한적이다. 이를 보완하기 위해 각 병원의 시스템을 적절히 이용하고 각 방법의 장점의 여러 요소들을 발전시킨다면 진단적 가치를 높이기 위한 방법의 하나로써 유용할 것으로 사료된다.

  • PDF

소아 충수염 진단에 CT의 유용성 (Usefulness of Preoperative Computed Tomography in Children with Clinically Suspected Appendicitis)

  • 전시열
    • Advances in pediatric surgery
    • /
    • 제19권2호
    • /
    • pp.57-65
    • /
    • 2013
  • The entity of negative appendectomies still poses a dilemma in chlidren. Focused computed tomography (CT) scanning has become the diagnostic test of choice in many hospitals. However, the impact of CT scans on the diagnosis in children is unknown exactly. The purpose of this study was to critically evaluate CT scans for the evaluation of acute appendicitis in children, to review utilization of this diagnostic test in our appendicitis population and to determine if diagnostic accuracy has improved. A retrospective analysis of efficacy of CT scan for diagnosis of appendicitis in children was conducted. Children undergoing appendectomy for acute appendicitis were reviewed from 2007 to 2012. Perforation and negative appendectomy (removal of a normal appendix) rates were determined by the final pathologic report. Statistical comparison were made using the $x^2$ test and significance was assigned at p < 0.05. Five hundred four appendectomies were performed. Mean age was $10.1{\pm}3.21$ years, and 62.7% were boys. Overall, 308 children (61.1%) underwent CT scanning, 100 (19.8%) had US performed, and 97 (19.2%) had no radiographic study. A pathologically normal appendix was removed in 8.7% (27 of 308) of CT patients, 9.0% (9 of 100) of US patients, and 11.3% (11 of 97) of patients without a study. The frequency of CT scanning increased from 29.7% (27 of 91) of all children in 2007 to 75.6% (59 of 78) in 2012, whereas utilization of US decreased from 30.8% (28 of 91) to 11.5% (9 of 78). During this time period the difference in the negative appendectomy rate did change significantly from 14% to 6%. Liberal use of CT scans in diagnosing appendicitis in children has resulted in a decreased negative appendectomy rate.

CT 촬영 조건에 따른 PET 영상의 변화 (Change of PET Image According to CT Exposure Conditions)

  • 박재윤;김정훈;이용기
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.473-479
    • /
    • 2019
  • 다양한 촬영 조건의 CT 감쇠 지도가 PET 영상에 영향을 미치는지 알아보기 위하여 다양한 kVp와 mA조건에서 Uniformity phantom 영상의 신호 강도(SI; Signal Intensity)와 표준 섭취율 계수(SUV; Standardized Uptake Value)를 측정하고, CTDI (Computed Tomography Dose Index)를 통해 각 조건에 따른 피폭선량을 측정하였다. 또한 동일한 조건에서 Resolution phantom의 반치폭(FWHM; Full Width at Half Maximum)을 측정하여 CT의 kVp와 mA에 따른 PET 영상의 화질 변화에 대하여 정량적으로 알아보고자 하였다. 연구 결과, CT의 촬영 조건은 PET 영상에는 영향을 주지 않는 것으로 나타났으나, CT의 촬영 조건이 감소하게 되면 방사선 피폭이 감소하게 되지만 영상에 영향을 미치게 되므로 향후 진단이 가능한 CT 화질을 유지하면서 방사선 피폭을 최소화할 수 있는 양전자 방출 단층 촬영(PET/CT; Positron Emission Tomography / Computed Tomography)의 촬영 조건에 대한 연구가 지속적으로 되어야 할 것이다.