• Title/Summary/Keyword: CT data

Search Result 1,288, Processing Time 0.029 seconds

Virtual Bronchoscopy for Diagnosis of Tracheo-Bronchial Disease (기관지질환 진단을 위한 가상내시경)

  • Kim, Do-Yeon;Park, Jong-Won
    • The KIPS Transactions:PartB
    • /
    • v.10B no.5
    • /
    • pp.509-514
    • /
    • 2003
  • The virtual bronchoscopy was implemented using chest CT images to visualize inside of tracheo-bronchial wall. The optical endoscopy procedures are invasive, uncomfortable for patients and sedation or anesthesia may be required. Also, they have serious side effects such as perforation, infection and hemorrhage. In order to determine the navigation path, we segmented the tracheo-bronchial wall from the chest CT image. We used the coordinates as a navigation path for virtual camera that were calculated from medial axis transformation. We used the perspective projection and marching cube algorithm to render the surface from volumetric CT image data. The tracheobronchial disease was classified into tracheobronchial stenosis causing from inflammation or lung cancer, bronchiectasis and bronchial cancer. The virtual bronchoscopy is highly recommended as a diagnosis tool with which the specific place of tracheobronchial disease can be identified and the degree of tracheobronchial disease can be measured qualitatively, Also, the virtual bronchoscopy can be used as an education and training tool for endoscopist and radiologist.

Development of a Compensating Algorithm for an Iron-cored Measurement CT using Flux-magnetizing Current Curves and Voltage-core Loss Current Curves (자속-자화 전류 곡선과 전압-철손 전류 곡선을 이용한 측정용 철심 변류기의 보상 알고리즘 개발)

  • Kang, Yong-Cheol;Zheng, Tai-Ying;Kang, Hae-Gweon;Lee, Byung-Eun;Kim, Yong-Gyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1849-1854
    • /
    • 2009
  • This paper describes the design, evaluation and implementation of a compensating algorithm for an iron-cored measurement current transformer (CT) that removes the effects of the hysteresis characteristics of the iron-core. The exciting current resulting from the hysteresis characteristics of the core causes an error of the CT. The proposed algorithm decomposes the exciting current into the core loss current and the magnetizing current and each of them is estimated. The core loss current is calculated from the secondary voltage and the voltage-core loss current curve. The core flux linkage is calculated and then inserted into the flux-magnetizing current curve to estimate the magnetizing current. The exciting current at every sampling interval is obtained by summing the core loss and magnetizing currents and then added to the measured current to obtain the correct secondary current. The voltage-core loss current curve and flux-magnetizing current curves, which are different from the conventional curves, are derived in this paper. The performance of the proposed algorithm is validated under various conditions using EMTP generated data. The experimental test results of an iron-core type electronic CT, which consists of the iron-core and the compensation board, are also included. The results indicate that the proposed algorithm can improve the accuracy of the measurement CT significantly, and thus reduce the size and the cost of the CT.

Image Quality and Radiation Dose of High-Pitch Dual-Source Spiral Cardiothoracic Computed Tomography in Young Children with Congenital Heart Disease: Comparison of Non-Electrocardiography Synchronization and Prospective Electrocardiography Triggering

  • Goo, Hyun Woo
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1031-1041
    • /
    • 2018
  • Objective: To compare image quality and radiation dose of high-pitch dual-source spiral cardiothoracic computed tomography (CT) between non-electrocardiography (ECG)-synchronized and prospectively ECG-triggered data acquisitions in young children with congenital heart disease. Materials and Methods: Eighty-six children (${\leq}3$ years) with congenital heart disease who underwent high-pitch dual-source spiral cardiothoracic CT were included in this retrospective study. They were divided into two groups (n = 43 for each; group 1 with non-ECG-synchronization and group 2 with prospective ECG triggering). Patient-related parameters, radiation dose, and image quality were compared between the two groups. Results: There were no significant differences in patient-related parameters including age, cross-sectional area, body density, and water-equivalent area between the two groups (p > 0.05). Regarding radiation dose parameters, only volume CT dose index values were significantly different between group 1 ($1.13{\pm}0.09mGy$) and group 2 ($1.07{\pm}0.12mGy$, p < 0.02). Among image quality parameters, significantly higher image noise ($3.8{\pm}0.7$ Hounsfield units [HU] vs. $3.3{\pm}0.6HU$, p < 0.001), significantly lower signal-to-noise ratio ($105.0{\pm}28.9$ vs. $134.1{\pm}44.4$, p = 0.001) and contrast-to-noise ratio ($84.5{\pm}27.2$ vs. $110.1{\pm}43.2$, p = 0.002), and significantly less diaphragm motion artifacts ($3.8{\pm}0.5$ vs. $3.7{\pm}0.4$, p < 0.04) were found in group 1 compared with group 2. Image quality grades of cardiac structures, coronary arteries, ascending aorta, pulmonary trunk, lung markings, and chest wall showed no significant difference between groups (p > 0.05). Conclusion: In high-pitch dual-source spiral pediatric cardiothoracic CT, additional ECG triggering does not substantially reduce motion artifacts in young children with congenital heart disease.

Evaluation of the Usefulness of Detection of Abdominal CT Kidney and Vertebrae using Deep Learning (딥러닝을 이용한 복부 CT 콩팥과 척추 검출 유용성 평가)

  • Lee, Hyun-Jong;kwak, Myeong-Hyeun;Yoon, Hye-Won;Ryu, Eun-Jin;Song, Hyeon-Gyeong;Hong, Joo-Wan
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.15-20
    • /
    • 2021
  • CT is important role in the medical field, such as disease diagnosis, but the number of examination and CT images are increasing. Recently, deep learning has been actively used in the medical field, and it has been used to diagnose auxiliary disease through object detection during deep learning using medical images. The purpose of study to evaluate accuracy by detecting kidney and vertebrae during abdominal CT using object detection deep learning in YOLOv3. As a results of the study, the detection accuracy of the kidney and vertebrae was 83.00%, 82.45%, and can be used as basic data for the object detection of medical images using deep learning.

Efficient Semi-automatic Annotation System based on Deep Learning

  • Hyunseok Lee;Hwa Hui Shin;Soohoon Maeng;Dae Gwan Kim;Hyojeong Moon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.18 no.6
    • /
    • pp.267-275
    • /
    • 2023
  • This paper presents the development of specialized software for annotating volume-of-interest on 18F-FDG PET/CT images with the goal of facilitating the studies and diagnosis of head and neck cancer (HNC). To achieve an efficient annotation process, we employed the SE-Norm-Residual Layer-based U-Net model. This model exhibited outstanding proficiency to segment cancerous regions within 18F-FDG PET/CT scans of HNC cases. Manual annotation function was also integrated, allowing researchers and clinicians to validate and refine annotations based on dataset characteristics. Workspace has a display with fusion of both PET and CT images, providing enhance user convenience through simultaneous visualization. The performance of deeplearning model was validated using a Hecktor 2021 dataset, and subsequently developed semi-automatic annotation functionalities. We began by performing image preprocessing including resampling, normalization, and co-registration, followed by an evaluation of the deep learning model performance. This model was integrated into the software, serving as an initial automatic segmentation step. Users can manually refine pre-segmented regions to correct false positives and false negatives. Annotation images are subsequently saved along with their corresponding 18F-FDG PET/CT fusion images, enabling their application across various domains. In this study, we developed a semi-automatic annotation software designed for efficiently generating annotated lesion images, with applications in HNC research and diagnosis. The findings indicated that this software surpasses conventional tools, particularly in the context of HNC-specific annotation with 18F-FDG PET/CT data. Consequently, developed software offers a robust solution for producing annotated datasets, driving advances in the studies and diagnosis of HNC.

Cut-Through versus Cut-Out: No Easy Way to Predict How Single Lag Screw Design Cephalomedullary Nails Used for Intertrochanteric Hip Fractures Will Fail?

  • Garrett W. Esper;Nina D. Fisher;Utkarsh Anil;Abhishek Ganta;Sanjit R. Konda;Kenneth A. Egol
    • Hip & pelvis
    • /
    • v.35 no.3
    • /
    • pp.175-182
    • /
    • 2023
  • Purpose: This study aims to compare patients in whom fixation failure occurred via cut-out (CO) or cut-through (CT) in order to determine patient factors and radiographic parameters that may be predictive of each mechanism. Materials and Methods: This retrospective cohort study includes 18 patients with intertrochanteric (IT) hip fractures (AO/OTA classification 31A1.3) who underwent treatment using a single lag screw design intramedullary nail in whom fixation failure occurred within one year. All patients were reviewed for demographics and radiographic parameters including tip-to-apex distance (TAD), posteromedial calcar continuity, neck-shaft angle, lateral wall thickness, and others. Patients were grouped into cohorts based on the mechanism of failure, either lag screw CO or CT, and a comparison was performed. Results: No differences in demographics, injury details, fracture classifications, or radiographic parameters were observed between CO/CT cohorts. Of note, a similar rate of post-reduction TAD>25 mm (P=0.936) was observed between groups. A higher rate of DEXA (dual energy X-ray absorptiometry) confirmed osteoporosis (25.0% vs. 60.0%) was observed in the CT group, but without significance. Conclusion: The mechanism of CT failure during intramedullary nail fixation of an IT fracture did not show an association with clinical data including patient demographics, reduction accuracy, or radiographic parameters. As reported in previous biomechanical studies, the main predictive factor for patients in whom early failure might occur via the CT effect mechanism may be related to bone quality; however, conduct of larger studies will be required in order to determine whether there is a difference in bone quality.

Survival Probability of the Patients with Cerebral Vascular Disease Who Visited an Oriental Hospital (모 한방병원에 내원한 뇌혈관 질환자들의 예후)

  • 김지용;서운교
    • The Journal of Korean Medicine
    • /
    • v.23 no.4
    • /
    • pp.91-97
    • /
    • 2002
  • Objective: This study was conducted to know the survival probability of the patients with cerebrovascular disease. Method: 1,341 patients who were suspected of having cerebrovascular disease clinically were investigated by telephone and NHIC (National Health Insurance Corporation) data. Conclusion: 1. The study population was grouped as 'Negative Brain CT findings' (11.8%), 'Hemorrhage' (12.4%) and 'Infarction' (75.7%). 2. The survival probabilities calculated by the Life Table method were statistically significant among brain CT finding groups (P<0.01). 3. The mean survival time calculated by the Kaplan-Meier method were also statistically significant among brain CT finding groups (P<0.01). 4. The result of Cox regression model was that sex (OR=0.7), age (OR=1.07), diabetes mellitus (OR=1.38), and heart disease (OR=1.69) affected the survival of the patients with cerebrovascular disease.

  • PDF

초고속 통신망을 이용한 척추 경나사못 삽입술 Simulator

  • 윤승식;성정환;최희원;김영호;강석호;염진섭
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1999.04a
    • /
    • pp.105-107
    • /
    • 1999
  • 본 연구의 목적은 CT장비로부터 얻어지는 단면 영상을 이용하여 재구성한 3차원 Voxel 정보를 기반으로 의료 시술 중 위험도가 높으며 장기간의 수술 훈련이 필요한 수술인 척추경나사 삽입술에 대한 모의 시술기를 개발하는 것이다. 모의 시술기의 입력은 환자의 환부에 대한 CT와 모의 시술을 해보고자 하는 의사 (사용자)의 입력 (경나사의 진입 위치와 각도)이 되며 출력은 의사들이 시술장에서 받을 수 있는 유일한 방법인 Voxel데이터로부터 재생성된 X-Ray이미지, 혹은 C-Arm의 동영상이며, 최종 결과 출력은 나사못이 삽입된 재구성 CT 이미지들과 3차원 정보를 볼 수 있는 Image Based Rendering의 Image data set이 된다. 본 연구에서는 각 시각화 부분의 특성을 고려하여 direct volume projection, surface modeling, 그리고 최근 많은 관심을 받고 있는 Image Based Rendering 기법을 intergrate하여 사용하였으며 각 시각화 모듈의 초고속 정보 통신망에서의 정보 교환에 대한 방법론에 대해 다루고 있다.

  • PDF

Dynamic Response Characteristics of Distance Relay Including the Instrumental Devices (계기용 변성기를 포함한 거리계전기의 동특성 해석)

  • 김남호;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.3
    • /
    • pp.227-236
    • /
    • 1992
  • In this paper, a simulation program of relaying system including the CT and CPD ( capacitive potential device ) is developed to study the effect of its operation under various system conditions. To deal with the dynamic characteristics of relaying system, state space technique is applied, and then the state equations of CT, CPD and mho distance relay are constructed. Also the dynamic response characteristics of overall relaying system is verified by digital simulation. Since the proposed model is capable of taking arbitrary input waveforms from EMTP in analyzing its dynamic responses, the effects of CT-saturation and CPD-subsidence transient characteristics on the operating points of who distance relay can be accurately prodicted. It gives more effective results, compared with the model without considering those characteristics by checking the exprimental data.

A study on the finite element modeling of femur based marching cube algorithm (Marching cube 알고리즘을 이용한 대퇴골의 유한요소 모델링에 관한 연구)

  • 곽명근;오택열;변창환;이은택;유용석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1074-1077
    • /
    • 2002
  • Biomechanical behavior of the human femur is very important in various clinical situations. In this study, the data of FE models based on DICOM file exported from Computed tomography(CT). We generated FE models(voxel model, tetra model) of human femur using CT slide image. We compared them with Yon Mises stress results derived from finite element analysis(FEA). Comparing the two models, we found a correlation of them. As a result, the tetra model based proposed marching cube algorithm is a valid and accurate method to predict parameters of the complex biomechanical behavior of human femur.

  • PDF