• Title/Summary/Keyword: CT data

Search Result 1,288, Processing Time 0.032 seconds

Critical Temperature for Early Marginal Transplanting of Japonica Rice in Korea (우리나라 자포니카 벼 품종의 조기이앙 한계온도 분석)

  • Woonho Yang;Shingu Kang;Dae-Woo Lee;Mi-Jin Chae
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.68 no.4
    • /
    • pp.246-261
    • /
    • 2023
  • We investigated critical temperature for early marginal transplanting (CT-EMT) of the contemporary japonica rice varieties in Korea through the field, pot seedling tray, and the phytotron experiments during 2020 to 2023. The lowest mean temperature for 10 days from transplanting (MT-10DFT) that resulted in earlier heading date was 12.4℃ and the highest MT-10DFT that did not show the earlier heading date was 12.0℃ in the field study when the MT-10DFT varied by changing transplanting date. The lowest MT-10DFT that induced the increased biomass but not the earlier heading date was 11.6℃ and the highest MT-10DFT that showed neither the increased biomass nor the earlier heading date was 11.4℃. Compared to the 10-day later transplanting, the dates of the first root development, initiation of the chlorophyll recovery, and the first tiller development were earlier when the MT-10DFT was 9.1℃ or higher, 10.5℃ or higher, and 11.6℃ or higher, respectively, in the pot seedling tray and field experiments. The earliness of the first tiller development was a practical index for the estimation of CT-EMT during the early growth stage of rice. The response of transplanted rice to temperature treatments with the diurnal change of 10℃ in the phytotron study was similar to that shown in the field study. The data shown for constant temperature without a diurnal change revealed that the extent of positive effects of high temperature at day-time was greater than the extent of negative effects of low temperature at night-time on the early growth of transplanted rice. It was concluded that the critical MT-10DFT for early marginal transplanting of japonica rice in the temperate environments was between 11.4 to 11.6℃ based on the plant growth and between 12.0 to 12.4℃ based on the plant development.

Estimation of Monthly Dissolved Inorganic Carbon Inventory in the Southeastern Yellow Sea (황해 남동부 해역의 월별 용존무기탄소 재고 추정)

  • KIM, SO-YUN;LEE, TONGSUP
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.27 no.4
    • /
    • pp.194-210
    • /
    • 2022
  • The monthly inventory of dissolved inorganic carbon (CT) and its fluxes were simulated using a box-model for the southeastern Yellow Sea, bordering the northern East China Sea. The monthly CT data was constructed by combining the observed data representing four seasons with the data adopted from the recent publications. A 2-box-model of the surface and deep layers was used, assuming that the annual CT inventory was at the steady state and its fluctuations due to the advection in the surface box were negligible. Results of the simulation point out that the monthly CT inventory variation between the surface and deep box was driven primarily by the mixing flux due to the variation of the mixed layer depth, on the scale of -40~35 mol C m-2 month-1. The air to sea CO2 flux was about 2 mol C m-2 yr-1 and was lower than 1/100 of the mixing flux. The biological pump flux estimated magnitude, in the range of 4-5 mol C m-2 yr-1, is about half the in situ measurement value reported. The CT inventory of the water column was maximum in April, when mixing by cooling ceases, and decreases slightly throughout the stratified period. Therefore, the total CT inventory is larger in the stratified period than that of the mixing period. In order to maintain a steady state, 18 mol C m-2 yr-1 (= 216 g C m-2 yr-1), the difference between the maximum and minimum monthly CT inventory, should be transported out to the East China Sea. Extrapolating this flux over the entire southern Yellow Sea boundary yields 4 × 109 g C yr-1. Conceptually this flux is equivalent to the proposed continental shelf pump. Since this flux must go through the vast shelf area of the East China Sea before it joins the open Pacific waters the actual contribution as a continental shelf pump would be significantly lower than reported value. Although errors accompanied the simple box model simulation imposed by the paucity of data and assumptions are considerably large, nevertheless it was possible to constrain the relative contribution among the major fluxes and their range that caused the CT inventory variations, and was able to suggest recommendations for the future studies.

Measurement of facial soft tissues thickness using 3D computed tomographic images (3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Shin Dong-Won;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

Positional Changes of the Internal Reference Points Followed by Reposition of the Maxilla - A Study of a 3D Virtual Surgery Program (상악골 재위치술 시행 시 골편의 이동량에 따른 내측기준점의 변화 - 3차원 가상수술 프로그램을 이용한 연구)

  • Suh, Young-Bin;Park, Jae-Woo;Kwon, Min-Su
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.5
    • /
    • pp.413-419
    • /
    • 2011
  • Purpose: Reposition of the maxilla is a common technique for correction of midfacial deformities. To achieve the goal of the surgery, the maxilla should be repositioned based on the precisely planned position during surgery. The internal reference points (IRPs) and the external reference points (ERPs) are usually used to determine vertical dimension of maxilla, which is an important factor for confirming maxillary position. However, the IRPs are known to be inaccurate in determining the vertical dimension. In this study, we investigated the correlation of positional change of the modified IRPs with repositioned maxilla. Methods: The study group consisted of 26 patients with dentofacial deformities. For the simulation of the surgery, patient maxillary CT data and 3-D virtual surgery programs (V-$Works^{(R)}$ and V-$Surgery^{(R)}$) were used. IRPs of this study were set on both the lateral wall of piriform aperture, inferior margin of both infraorbital foramen, and the labial surfaces of the canine and first molar. The distance from the point on lateral wall of the piriform aperture to the point on the buccal surface of the canine was defined as IRP-C, and the distance from the point on the inferior margin of the infraorbital foramen to the point on the buccal surface of the $1^{st}$ molar was defined as IRP-M. After the virtual simulation of Le Fort I osteotomy, the changes in IRP-C and IRP-M were compared with the maxillary movement. All measures were analyzed statistically. Results: With respect to vertical movements, the IRP-C (approximately 98%) and the IRP-M (approximately 96%) represented the movement of the canine and the $1^{st}$ molar. Regarding rotating movement, the IRPs changed according to the movement of the canine and the $1^{st}$ molar. In particular, the IRP-C was changed in accordance with the canine. Conclusion: IRPs could be good indicators for predicting vertical movements of the maxilla during surgery.

Development of a Stereotactic Radiosurgery Planning System (뇌정위 방사선수술을 위한 컴퓨터 치료계획시스템의 개발)

  • 조병철;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.17-24
    • /
    • 1997
  • We developed PC-based planning system for linear accelerator based stereotactic radiosurgery. The system was developed under Windows 95 on Pentium Pro$\^$(R) 200 ㎒ IBM PC with 128 MB RAM. It was programed using IDL$\^$(R)/ of Research Systems, Inc. as a programing tool. CT image data obtained with BRW stereotactic frame is transferred to PC through magnetoptical disk. As loading the image, the system automatically recognizes the location of rods and establishes stereotactic coordinates. It accurately calculates and corrects the coordinates, degree of tilting, and magnification rate of axial images. After the coordinates is defined we can delineate and edit the contours of target and organs of interest on axial images. Upon delineating contours of target, isocenter is determined automatically and we can set up the beam configuration for radiosurgery. The system provides beam's eye view and room's eye view for efficient confuguring of beams. The system calculates dose distribution 3-dimensionally. It takes 1 to 2 minutes to calculate dose distribution for 5 arcs. We can verify the dose distribution on serial axial images. We can analyze the dose distribution quantitatively by evaluation of dose-volume histogram of target and organ of interest. This system, PC-based radiosurgery planning system, includes the basic features for radiosurgery planning and calculates dose distribution within reasonable time for clinical application.

  • PDF

DESIGN OF AIR SEAT CUSHION ORTHOSIS FOR PLEGIA

  • Hong, Jung-Hwa;Kim, Gyoo-Suk;Kim, Jong-Kwon;Mun, Mu-Seong;Ryu, Jei-Cheong;Lee, In-Huk;Lee, Jong-Keun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.121-123
    • /
    • 2002
  • The design of an air seat cushion for preventing decubitus ulcer includes many design factors such as the even distribution of interface pressure, the minimization of mean and peak interface pressure values, and the reduction of interface shear force and pressure gradient. It involves the anatomic condition of plegia's buttock as well as air pressure in air cells of cushion. As a result, a suitable design of the cushion satisfying the all requirements is a difficult problem. Therefore, an appropriate and effective numerical tool to develop an air cushion orthosis is required. The purpose of the present study was to develop an air seat cushion orthosis having optimized air cells for evenly distributed interface pressure between the buttock and cushion surface. For the purpose, an advanced finite element (FE) model for the design of air cushion was developed. Since the interface pressure and shear force behavior, as well as stress analyses were primary concern, a FE air cell model was developed and verified by the experiments. Then, the interactions of two cells were checked. Also, the human part of the developed numerical model includes every material property and geometry related to buttock and femoral parts. For construction of dimension data of buttock and femoral parts, CT scans were performed. A commercial FE program was employed for the simulation representing the seating process on the orthosis. Then, sensitive analyses were performed with varying design parameters. A set of optimal design parameters was found satisfying the design criteria of the orthosis. The results were utilized to produce a prototype of the orthosis. Experimentally, the buttock interface pressure distributions from the optimized and previous ones were compared. The new seat orthosis showed a significantly improved interface pressure characteristics compared to the most popular one in the market. The new orthosis will be used for the development of the AI(artificial intelligent) controlled seat orthosis fur prevention of decubitus ulcer fur various plegic patients and the elderly.

  • PDF

Aortocaval Fistula - A case report - (대동맥-대정맥루 -치험 1예-)

  • Cho Kwang-Hyun;Kwon Young-Min;Han Il-Yong;Jun Hee-Jae;Lee Yang-Haeng;Hwang Youn-Ho;Yoon Young-Chul
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.721-724
    • /
    • 2005
  • Aortocaval fistula is a rare complication of abdominal aortic aneurysm, involving less than $1\%$ of all abdominal aortic aneurysms. A 64-years old man with a long history of hypertension and abdominal aortic aneurysm had chest pain, dyspnea, epigastric discomfort and palpable abdominal pulsating mass. Physical examination revealed hypo­tension with a systolic blood pressure of 70 mmHg, a large pulsatile mass and a systolic abdominal bruit. Laboratory data revealed a hemoglobin values of 11.0 g/dL, blood urea nitrogen (BUN) value of 5 mg/dL, and creatine value of $2.5 mg\%$. Abdominal Angio CT showed a 10cm infrarenal abdominal aortic aneurysm with dilatation of the IVC and aortocaval fistula from the aortic aneurysm, which was confirmed at emergency surgery. When the aneurysm was opened and the thrombus was removed, a 1 cm communication was identified between the aorta and IVC. This was controlled with Foley catheters ballooning, and the fistula was closed by continuous suture placed outside the aneurysm. A bifurcated aorto-iliac graft was used to restore arterial continuity. The patient was discharged home after uncomplicated postoperative course.

Surgery versus Conservative Treatment for Spontaneous Supratentorial Intracerebral Hemorrhage in Spot Sign Positive Patients

  • Kim, Hui-Tae;Lee, Jong-Myong;Koh, Eun-Jeong;Choi, Ha-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.309-315
    • /
    • 2015
  • Objective : An advantage of surgical treatment over conservative treatment of spontaneous intracerebral hemorrhage (ICH) is controversial. Recent reports suggest that contrast extravasations on CT angiography (CTA) might serve as a crucial predictor of hematoma expansion and mortality. The purpose of this study was aimed at investigating the efficacy of surgical treatment in patients with spot sign positive ICH. Methods : We used our institutional medical data search system to identify all adult patients who admitted for treatment of ICH between January 1, 2007 and January 31, 2012. Patients were classified two groups into a surgical group (n=27) and a conservative treatment group (n=28). Admission criteria were the following: age 20-79 years, spontaneous supratentorial ICH, Glasgow Coma Score Ranging from 9 to 14, ICH volume ${\geq}20mL$, and treatment within 24 hours. Results : Fifty-five patients were analyzed. There was no significant difference in the ICU stay between the conservative treatment group ($7.36{\pm}3.66days$) and the surgical treatment group ($6.93{\pm}2.20days$; p=0.950). There was a significant difference in the in-hospital stay between the conservative treatment group ($13.93{\pm}8.87days$) and the surgical treatment group ($20.33{\pm}6.37days$; p=0.001). Overall mortality at day 90 after ICH was 36.4%; this included 16 of 28 patients (57.1%) in the conservative group and 4 of 27 patients (14.8%) in the surgical group. In univariate analysis, there was a positive effect of the surgical treatment in reducing mortality at 90 days (p=0.002), Glasgow Outcome Scale (GOS) at 90-day (p=0.006), and modified Rankin Scale (mRS) at 90-day (p=0.023). In multivariate logistic analysis, there was a significant difference in mortality (odds ratio, 0.211; 95% confidence interval, 0.049-0.906; p=0.036) between the groups at 90-day follow-up. However, there was no significant difference in GOS (odds ratio, 0.371; 95% confidence interval, 0.031-4.446; p=0.434) and mRS (odds ratio, 1.041; 95% confidence interval, 0.086-12.637; p=0.975) between the groups at 90-day follow-up. Conclusion : In this study of surgical treatment of supratentorial ICH in patients with spot sign positive in CTA was associated with less mortality despite of long duration of in-hospital stay. We failed to show that clinical outcome benefit of surgical treatment compared with conservative treatment in patients with spot sign positive ICH.

Correction of Prompt Gamma Distribution for Improving Accuracy of Beam Range Determination in Inhomogeneous Phantom

  • Park, Jong Hoon;Kim, Sung Hun;Ku, Youngmo;Lee, Hyun Su;Kim, Young-su;Kim, Chan Hyeong;Shin, Dong Ho;Lee, Se Byeong;Jeong, Jong Hwi
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.207-217
    • /
    • 2017
  • For effective patient treatment in proton therapy, it is therefore important to accurately measure the beam range. For measuring beam range, various researchers determine the beam range by measuring the prompt gammas generated during nuclear reactions of protons with materials. However, the accuracy of the beam range determination can be lowered in heterogeneous phantoms, because of the differences with respect to the prompt gamma production depending on the properties of the material. In this research, to improve the beam range determination in a heterogeneous phantom, we derived a formula to correct the prompt-gamma distribution using the ratio of the prompt gamma production, stopping power, and density obtained for each material. Then, the prompt-gamma distributions were acquired by a multi-slit prompt-gamma camera on various kinds of heterogeneous phantoms using a Geant4 Monte Carlo simulation, and the deduced formula was applied to the prompt-gamma distributions. For the case involving the phantom having bone-equivalent material in the soft tissue-equivalent material, it was confirmed that compared to the actual range, the determined ranges were relatively accurate both before and after correction. In the case of a phantom having the lung-equivalent material in the soft tissue-equivalent material, although the maximum error before correction was 18.7 mm, the difference was very large. However, when the correction method was applied, the accuracy was significantly improved by a maximum error of 4.1 mm. Moreover, for a phantom that was constructed based on CT data, after applying the calibration method, the beam range could be generally determined within an error of 2.5 mm. Simulation results confirmed the potential to determine the beam range with high accuracy in heterogeneous phantoms by applying the proposed correction method. In future, these methods will be verified by performing experiments using a therapeutic proton beam.

Clinical Significance of Abdominal Fat Distribution in Korean Male Children and Adolescents (한국 소아 청소년 남아에서 복부 지방 분포 측정의 임상적 의의)

  • Lee, Yeoun-Joo;Kim, Kyung-Mo;Oh, Seak-Hee;Park, Hye-Soon;Myong, Jun-Pyo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.13 no.2
    • /
    • pp.172-179
    • /
    • 2010
  • Purpose: Visceral adipose tissue may be strongly linked to increased metabolic risks in adults. However, because little is known regarding the effect of visceral adipose tissue in children and adolescents, we performed this study to determine the association between abdominal fat distribution and metabolic risk factors in this population. Methods: One hundred one children and adolescents (78 males and 23 females; mean age, 10.8${\pm}$2.4 years) were enrolled. The anthropometric data and metabolic risk factors were evaluated. Theabdominal fat distribution was assessed according to the CT measurement. Age-adjusted, partial correlations were performed among the visceral adipose fat area (VFA), subcutaneous adiposefat area (SFA), metabolic risk factors, and anthropometrics. Results: The SFA increased more rapidly than the VFA with advancing years in both genders. In males, the VFA and SFA were positively correlated with anthropometrics. The VFA was correlated with low HDL-cholesterol and the SFA was correlated with diastolic blood pressure (DBP). However, there was no statistical significance between the VFA, SFA, anthropometrics, and other metabolic risk factors. The VFA and SFA were strongly linked to a number of metabolic risk factors, such as other anthropometrics. Conclusion: This study investigated how a low HDL-C was correlated with VFA and how a high DBP was associated with SFA in Korean male children and adolescents. Our results suggest that the correlation between the VFA, SFA, and metabolic risk factors was relatively weak compared to that reported in previous adult studies.