• Title/Summary/Keyword: CT data

Search Result 1,288, Processing Time 0.028 seconds

The Natural History and Growth Rate of Meningiomas

  • Han, Jung-Ho;Seol, Ho-Jun;Kim, Dong-Gyu;Jung, Hee-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.3
    • /
    • pp.198-203
    • /
    • 2006
  • Objective : To evaluate the natural histories and growth rates of meningiomas, the authors perform this retrospective observational study and attempt to identify those factors predicting tumor growth. Methods : Between 1993 and 2004, a total of 83 patients were diagnosed by computed tomography[CT] scans or magnetic resonance[MR] imaging as having an intracranial meningioma, and were treated by observation only using regular clinical and radiological examinations. Twenty-six of these 83 patients, with available data were included in this study. Follow up periods ranged from 9 to 137 months [mean, 55.6 mo.; median, 60 mo.]. The tumor volumes, absolute growth rates, and tumor doubling times were calculated. Results : Patient age and sex distributions were comparable to those of other studies, but exceptionally 16 meningiomas [62%] were located at the skull base in the present study. During follow-up monitoring, the majority of meningiomas grew, though 77% showed low absolute annual growth rates [$<1cm^3/yr$]. The tumor doubling times ranged from 2.87 to 201.72 years [mean, 42.91 yr]. Based on Imaging analysis, peritumoral edema and the absence of calcification were probable factors predicting tumor growth. Tumor-related symptoms seemed to be slightly related to tumor growth. Other factors, e.g., gender, age, tumor location, and T2-weighted signal Intensities on MR imaging, were not significantly related to tumor growth. Conclusion : This study shows that the majority of meningiomas are slow growing. However, variations in tumor growth are unexplained, thus individualized optimal treatment strategies should be provided in each meningioma.

Image Transfer Using Cellular Phones and Wireless Internet Service

  • Shin, Dong-Ah;Doo, Tae-Hoon;Kim, Hyo-Jun;Kim, Hyoung-Ihl
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.6
    • /
    • pp.471-474
    • /
    • 2006
  • Objective : Neuroimaging data are of paramount importance in making correct diagnosis. We herein evaluate the clinical usefulness of image transfer using cellular phones to facilitate neurological diagnosis and decision-making. Methods : Selected images from CT, MRI scans, and plain films obtained from 50 neurosurgical patients were transferred by cellular phones. A cellular phone with a built-in 1,300,000-pixel digital camera was used to capture and send the images. A cellular phone with a 262,000 color thin-film transistor liquid crystal display was used to receive the images. Communication between both cellular phones was operated by the same wireless protocol and the same wireless internet service. We compared the concordance of diagnoses and treatment plans between a house staff who could review full-scale original films and a consultant who could only review transferred images. These finding were later analyzed by a third observer. Results : The mean time of complete transfer was $2{\sim}3\;minutes$. The quality of all images received was good enough to make precise diagnosis and to select treatment options. Transferred images were helpful in making correct diagnosis and decision making in 49/50 [98%] cases. Discordant result was caused in one patient by improper selection of images by the house staff. Conclusion : The cellular phone system was useful for image transfer and delivery patient's information, leading to earlier diagnosis and initiation of treatment. This usefulness was due to sufficient resolution of the built-in camera and the TFT-LCD, the user-friendly features of the devices, and their low cost.

Skull Reconstruction with Custom Made Three-Dimensional Titanium Implant

  • Cho, Hyung Rok;Roh, Tae Suk;Shim, Kyu Won;Kim, Yong Oock;Lew, Dae Hyun;Yun, In Sik
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.1
    • /
    • pp.11-16
    • /
    • 2015
  • Background: Source material used to fill calvarial defects includes autologous bones and synthetic alternatives. While autologous bone is preferable to synthetic material, autologous reconstruction is not always feasible due to defect size, unacceptable donor-site morbidity, and other issues. Today, advanced three-dimensional (3D) printing techniques allow for fabrication of titanium implants customized to the exact need of individual patients with calvarial defects. In this report, we present three cases of calvarial reconstructions using 3D-printed porous titanium implants. Methods: From 2013 through 2014, three calvarial defects were repaired using custom-made 3D porous titanium implants. The defects were due either to traumatic subdural hematoma or to meningioma and were located in parieto-occipital, fronto-temporo-parietal, and parieto-temporal areas. The implants were prepared using individual 3D computed tomography (CT) data, Mimics software, and an electron beam melting machine. For each patient, several designs of the implant were evaluated against 3D-printed skull models. All three cases had a custom-made 3D porous titanium implant laid on the defect and rigid fixation was done with 8 mm screws. Results: The custom-made 3D implants fit each patient's skull defect precisely without any dead space. The operative site healed without any specific complications. Postoperative CTs revealed the implants to be in correct position. Conclusion: An autologous graft is not a feasible option in the reconstruction of large calvarial defects. Ideally, synthetic materials for calvarial reconstruction should be easily applicable, durable, and strong. In these aspects, a 3D titanium implant can be an optimal source material in calvarial reconstruction.

The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut

  • Guleryuz, Aysegul;Korkmaz, Cumhur;Sener, Ayse;Tas, Mehmet Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.304-315
    • /
    • 2021
  • PURPOSE. Esthetic expectations have increased the use of polyetheretherketone (PEEK) clasps as alternatives to Cr-Co in removable partial dentures (RPDs). The objective of this study was to evaluate the retentive force and dimensional change of clasps with different thickness and undercut made from PEEK by the thermo-mechanical fatigue. MATERIALS AND METHODS. PEEK clasps (N = 48) with thicknesses of 1 or 1.50 mm and 48 premolar monolithic zirconia crowns with undercuts of 0.25 mm or 0.50 mm were fabricated. Samples are divided into four groups (C1-C4) and were subjected to 7200 thermal aging cycles (at 5 - 55℃). The changes in the retentive force and dimensions of the clasps were measured by micro-stress testing and micro-CT devices from five measurement points (M1 - M5). One-way ANOVA, paired t-test, two-way repeated ANOVA, and post-hoc tests were used to analyze the data (P < .05). RESULTS. The retentive forces of C1, C2, C3, and C4 groups in initial and final test were found to be 4.389-3.388 N, 4.67 - 3.396 N, 5.161 - 4.096 N, 5.459 - 4.141 N, respectively. The effects of retentive force of all PEEK clasps groups were significant decreased. Thermo-mechanical cycles caused significant dimensional changes at points with M2, M4, and M5, and abraded the clasp corners and increased the distance between the ends of the clasp, resulting in reduced retentive forces (P* = .016, P* = .042, P < .001, respectively). CONCLUSION. Thermo-mechanical aging decreases the retentive forces in PEEK clasps. Increasing the thickness and undercut amount of clasps decreases the amount of dimensional change. The values measured after aging are within the clinically acceptable limits.

Shoulder Arthrokinematics of Collegiate Ice Hockey Athletes Based on the 3D-2D Model Registration Technique

  • Jeong, Hee Seong;Song, Junbom;Lee, Inje;Kim, Doosup;Lee, Sae Yong
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.155-161
    • /
    • 2021
  • Objective: There is a lack of studies using the 3D-2D image registration techniques on the mechanism of a shoulder injury for ice hockey players. This study aimed to analyze in vivo 3D glenohumeral joint arthrokinematics in collegiate ice hockey athletes and compare shoulder scaption with or without a hockey stick using the 3D-2D image registration technique. Method: We recruited 12 male elite ice hockey players (age, 19.88 ± 0.65 years). For arthrokinematic analysis of the common shoulder abduction movements of the injury pathogenesis of ice hockey players, participants abducted their dominant arm along the scapular plane and then grabbed a stick using the same motion under C-arm fluoroscopy with 16 frames per second. Computed tomography (CT) scans of the shoulder complex were obtained with a 0.6-mm slice pitch. Data from the humerus translation distances, scapula upward rotation, anterior-posterior tilt, internal to external rotation angles, and scapulohumeral rhythm (SHR) ratio on glenohumeral (GH) joint kinematics were outputted using a MATLAB customized code. Results: The humeral translation in the stick hand compared to the bare hand moved more anterior and more superior until the abduction angle reached 40°. When the GH joint in the stick hand was at the maximal abduction of the scapula, the scapula was externally rotated 2~5° relative to 0°. The SHR ratio relative to the abduction along the scapular plane at 40° indicated a statistically significant difference between the two groups (p < 0.05). Conclusion: With arm loading with the stick, the humeral and scapular kinematics showed a significant correlation in the initial section of the SHR. Although these correlations might be difficult in clinical settings, ice hockey athletes can lead to the movement difference of the scapulohumeral joints with inherent instability.

Unilateral Maxillary Sinus Lesion : A Retrospective Study of 318 Cases with Surgical Treatment (수술로써 치료한 일측성 상악동 병변 318예의 후향적 연구)

  • Lee, Ho Byoung;Lee, Sang Hoon;Moon, Ji Seung;Park, Geun Hyung;Koo, Soo Kweon
    • Journal of Clinical Otolaryngology Head and Neck Surgery
    • /
    • v.29 no.2
    • /
    • pp.204-211
    • /
    • 2018
  • Background and Objectives : Unilateral maxillary sinus lesions are relatively common but may occur in variety of causes. Therefore, accurate diagnosis and appropriate treatment are needed. The aim of this study is to review patients with unilateral maxillary sinus lesion who underwent surgical treatment and to analyze causes and characteristics of unilateral maxillary sinus lesions with literature review. Materials and Methods : A retrospective chart analysis was completed on 318 patients with unilateral maxillary sinus lesions who underwent surgical treatment from January, 2008 through May, 2018. Clinical history and data such as age, sex, symptoms of initial, radiologic and dental finding, operation type were collected from medical record. Results : Patients mean age was 50.7 years with slight male gender dominance. Most common type was sinusitis (42.7%), followed by odontogenic sinusitis (22.3%) and fungal ball (19.5%). In particular, the most common cause of odontogenic sinusitis was post dental surgery such as implant. Middle meatal antrostomy (90.9%) was accounted for a great part of surgery underwent to patients. Patients complained of post nasal discharge (62.9%), nasal obstruction (40.9%) and odor smell(35.2%) most commonly. Periapical lucency (35.8%) was the most common in CT finding followed by implant perforation (17.3%) and oroantral fistula (12.3%) in odontogenic sinusitis. Conclusions : Unilateral maxillary sinus lesions are relatively common, but they are increasing recently with dental procedures such as implant surgery, and serious adverse effects due to malignant tumors or improper treatment may occur, so accurate diagnosis and treatment are needed.

Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible

  • Alom, Ghaith;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.12-23
    • /
    • 2021
  • Purpose. The aim of the study was to compare the lingualized implant placement creating a buccal cantilever with prosthetic-driven implant placement exhibiting excessive crown-to-implant ratio. Materials and Methods. Based on patient's CT scan data, two finite element models were created. Both models were composed of the severely resorbed posterior mandible with first premolar and second molar and missing second premolar and first molar, a two-unit prosthesis supported by two implants. The differences were in implants position and crown-to-implant ratio; lingualized implants creating lingually overcontoured prosthesis (Model CP2) and prosthetic-driven implants creating an excessive crown-to-implant ratio (Model PD2). A screw preload of 466.4 N and a buccal occlusal load of 262 N were applied. The contacts between the implant components were set to a frictional contact with a friction coefficient of 0.3. The maximum von Mises stress and strain and maximum equivalent plastic strain were analyzed and compared, as well as volumes of the materials under specified stress and strain ranges. Results. The results revealed that the highest maximum von Mises stress in each model was 1091 MPa for CP2 and 1085 MPa for PD2. In the cortical bone, CP2 showed a lower peak stress and a similar peak strain. Besides, volume calculation confirmed that CP2 presented lower volumes undergoing stress and strain. The stresses in implant components were slightly lower in value in PD2. However, CP2 exhibited a noticeably higher plastic strain. CONCLUSION. Prosthetic-driven implant placement might biomechanically be more advantageous than bone quantity-based implant placement that creates a buccal cantilever.

Comparison of Correlation Coefficients and Intraclass Correlation Coefficients Between Two-way FSI Flow Velocity of Simulated Abdominal Aorta and Human 4D Flow MRI Flow Velocity (시뮬레이션 복부 대동맥의 양방향 FSI 유속과 인체 4D flow MRI 유속의 상관계수, 급내상관계수 비교)

  • Ahn, Hae Nam;Kim, Jung Hun;Park, Ji eun;Choi, Hyeun Woo;Lee, Jong Min
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.143-149
    • /
    • 2021
  • In order to predict and prevent the disease of the abdominal aorta, which is the largest artery in the human body and the most common aneurysm, the normal arterial blood flow operation should be considered. To this end, we are trying to solve problems that may arise in the future by executing FSI based on the data obtained from 4D flow MRI. However, to match the similarity between the 4D flow MRI flow and the FSI flow, correlation was used in previous papers, but the correlation did not show the degree of agreement. Therefore, in this paper, we analyzed the correlation between the 4D flow MRI flow velocity of the human abdominal aorta and the two-way FSI flow velocity in which the three physical properties used for the aortic FSI were added to the CT abdominal aorta 3D model and the interclass correlation coefficient. As a result, the physical property M2 showed the highest similarity in correlation and intraclass correlation coefficient, and this property is intended to be helpful in the future study of the abdominal aortic two-way FSI flow rate.

Selection of suitable reference gene for gene expression studies of porcine ovaries under different conditions in quantitative reverse transcription polymerase chain reaction assay

  • Kim, Hwan-Deuk;Jeon, Hye-Jin;Jang, Min;Bae, Seul-Gi;Yun, Sung-Ho;Han, Jee-Eun;Kim, Seung-Joon;Lee, Won-Jae
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.37 no.2
    • /
    • pp.96-105
    • /
    • 2022
  • The ovary undergoes substantial physiological changes along with estrus phase to mediate negative/positive feedback to the upstream reproductive tissues and to play a role in producing a fertilizable oocyte in the developing follicles. However, the disorder of estrus cycle in female can lead to diseases, such as cystic ovary which is directly associated with decline of overall reproductive performance. In gene expression studies of ovaries, quantitative reverse transcription polymerase chain reaction (qPCR) assay has been widely applied. During this assay, although normalization of target genes against reference genes (RGs) has been indispensably conducted, the expression of RGs is also variable in each experimental condition which can result in false conclusion. Because the understanding for stable RG in porcine ovaries was still limited, we attempted to assess the stability of RGs from the pool of ten commonly used RGs (18S, B2M, PPIA, RPL4, SDHA, ACTB, GAPDH, HPRT1, YWHAZ, and TBP) in the porcine ovaries under different estrus phase (follicular and luteal phase) and cystic condition, using stable RG-finding programs (geNorm, Normfinder, and BestKeeper). The significant (p < 0.01) differences in Ct values of RGs in the porcine ovaries under different conditions were identified. In assessing the stability of RGs, three programs comprehensively agreed that TBP and YWHAZ were suitable RGs to study porcine ovaries under different conditions but ACTB and GAPDH were inappropriate RGs in this experimental condition. We hope that these results contribute to plan the experiment design in the field of reproductive physiology in pigs as reference data.

Effect of an aluminum chloride hemostatic agent on the dentin shear bond strength of a universal adhesive

  • Sujin Kim;Yoorina Choi;Sujung Park
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.14.1-14.11
    • /
    • 2023
  • Objectives: This study investigated the effect of an aluminum chloride hemostatic agent on the shear bond strength (SBS) of a universal adhesive to dentin. Materials and Methods: Eighty extracted human molars were trimmed at the occlusal dentin surfaces and divided mesiodistally. According to hemostatic agent application, specimens were randomly allocated into control (C) and hemostatic agent (Traxodent; H) groups. Each group was divided into 4 subgroups according to the adhesive system (n = 20): Scotchbond Multi-Purpose (SBER), Clearfil SE Bond (CLSE), All-Bond Universal etch-and-rinse mode (ALER), and All-Bond Universal self-etch mode (ALSE). SBS was measured for half of the specimens at 24 hours, and the other half were thermocycled in water baths (group T). Fracture surfaces were examined to determine the failure mode. The SBS was measured, and data were analyzed using 1-way analysis of variance, the Student's t-test, and the Tukey honestly significant difference test (p = 0.05). Results: No significant differences in SBS were found between groups C and H for any adhesive system at 24 hours. After thermocycling, a statistically significant difference was observed between CT+ALSE and HT+ALSE (p < 0.05). When All-Bond Universal was applied to hemostatic agent-contaminated dentin, the SBS of H+ALSE was significantly lower than that of H+ALER (p < 0.05). The SBER subgroups showed no significant differences in SBS regardless of treatment and thermocycling. Conclusions: When exposed dentin was contaminated by an aluminum chloride hemostatic agent before dentin adhesive treatment, application of All-Bond Universal in etch-and-rinse mode was superior to self-etch mode.