• Title/Summary/Keyword: CT channel

Search Result 71, Processing Time 0.033 seconds

Evaluation of Surface Radiation Dose Reduction and Radiograph Artifact Images in Computed Tomography on the Radiation Convergence Shield by Using Sea-Shells (전산화단층영상장비에서 패각을 이용한 방사선 융합차폐체의 표면 방사선량 감소율과 방사선 인공물 영상 평가)

  • Seoung, Youl-Hun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.2
    • /
    • pp.113-120
    • /
    • 2017
  • The purpose of this present study was to evaluate the surface radiation dose reduction and radiograph artifact images in computed tomography (CT) for the manufactured radiation shields by using sea-shells. The radiation convergence shields were made from silicons, sea-shells, barium powders, producted circle types of diameter 50 mm, thickness 3.5 mm for 5 kinds (only silicon shield, only barium shield, mixed sea-shells with silicon shield, mixed barium with silicon shield, mixed sea-shells with barium and silicon shield). Radiation generation and acquisition were used 4-channel multi-detector CT. The results of this study showed that mixed sea-shells with silicon shields could reduce the surface dose of 5.3% without radiograph artifact images. In the future, we will expect the radiation convergence shield as environmentally friendly materials by using the recycling of sea-shells with the advantages of silicon which can make various shapes.

The Analysis of Cerebral Aneurysm's Prone position Using Computed Tomography Equipment (전산화단층촬영장치를 이용한 뇌동맥류의 호발부위 분석)

  • Lee, Seon-Tae;Lim, Jong-Soo;Park, Jeong-Kyu
    • Journal of Digital Contents Society
    • /
    • v.12 no.3
    • /
    • pp.271-277
    • /
    • 2011
  • This research studied 249 patients who has an aneurysm and went through computerized CT angiography at S University Hospital in Northern Kyung-sang area from October 1st 2008 to September 30th 2010, and the results are the following. Among total 249 of research objects, 159 women (63.9%) showed higher distribution than 90 men (36.1%) The order of the distribution of aneurysm classified by blood vessel is the following. Posterior communicating artery 34.9% as the highest, internal carotid artery 21.7%, middle cerebral artery of 15.7%, anterior communicating artery 14.5%, posterior cerebral artery and posterior cerebral artery channel 3.6% each, anterior cerebral artery and vertebral artery 2.4% each, and posterior inferior cerebellar artery 1.2%. As a result of analysis of distribution of aneurysm classified by gender, there was no case of posterior cerebral artery and posterior cerebral artery channel among men, and there was no case of posterior inferior cerebellar artery among women. Distribution of aneurysm classified by vessel according to gender showed no statistic significance. (p<0.05). And distribution of aneurysm classified by vessel according to the age, showed no statistic significance. (p>0.05), After applying post analysis to understand the group with age difference, the significance was the highest among the group of 61-70, (4.21), and the group of the age under 30 was the lowest. (2.0) There was statistic significance on the distribution of aneurysm classified by vessel according to the season. (p<0.05). After applying post-analysis in order to understand the groups with difference between seasons, it was found that fall was the highest (4.55) and spring was the lowest. (2.50)

Fabrication of High Frequency Magnetic Characteristics Measurement System Using Digital Oscilloscope and Computer Remote Control (디지털 오실로스코프와 컴퓨터 제어기법을 이용한 고주파 자기특성 측정장치 제작)

  • 김기옥;이재복;송재성;민복기
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.6
    • /
    • pp.327-333
    • /
    • 1997
  • We designed and constructed the high frequency magnetic characteristics measurement system to measure core loss, B-H curve, permeability of toroidal ferrite core, amorphous core and various materials for high frequency application. The system consists of universal equipments such as digitizing oscilloscope, signal generator, power amplifier, PC in order to make upgrade easily. The power source is composed of waveform synthesizer and power amplifier ranging from DC to 20 MHz, and output signal H and B from sample core are digitized by oscilloscope with sampling rate 1 GS/ s per channel. Computer controls power source and oscilloscope, reads data from oscilloscope, displays analyzed waveform and saves data with file. The entire procedures finishes within few seconds.

  • PDF

The Clinical Study on the Efficiency of the A-Shi Point (추간판탈출증환자의 침구치료에서의 아시혈 병행에 대한 임상적 고찰)

  • Yoon, Ki-Boong;Cho, Ma-Lee-Na;Jung, Hong
    • Journal of Acupuncture Research
    • /
    • v.18 no.1
    • /
    • pp.226-236
    • /
    • 2001
  • Objects : To evaluate clinical efficiency of The A-Shi point for the herniated lumbar intervertebral disc. Methods : The patients who had a diagnosis of herniated lumbar intervertebral disc by lumber CT and MRI, and were observed from the twentieth March 2000 to the tenth Novemsber 2000, were divided into two classes ; the "A" group was 15 cases practiced with Acupuncture treatment used of A-Shi point and the twelve-Meridian, the "B"group 15cases only Acupuncture treatment used of twelve-Meridian, Results : the most type of low back pain was, the Gall bladder channel of Foot-souyang 15 cases (50%) and the Gall-Bladder Meridian Muscle was 45 cases the most in the existence part of A-Shi point On the result of treatment due to clinical symptoms, the "A" group was 57.9% as excellent and "B" group 19.8%. On the measurement of Lumber flexion, the "A" group proceed more excellent result than the "B group at the whole grade. Conclusion : These results suggest that The A-shi point was effective treatment of herniated intervertebral disc.

  • PDF

Fabrication of Artificial Bone through the Imitation of human bone

  • Jang, Dong-U;Sakar, Swapan Kumar;Kim, Min-Sung;Song, Ho-Yeon;Min, Young-Gi;Lee, Byong-Taek
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.41.2-41.2
    • /
    • 2010
  • In this work, HAp-(t-ZrO2) ceramic composites of biomimic artificial bone were fabricated by multi-extrusion process in order to replace nature bone. HAp-(t-ZrO2) and graphite powders were mixed separately with ethylene vinyl acetate (EVA) and stearic acid using shear mixer. Extruded HAp-(t-ZrO2) filaments and carbon filaments were arranged in the die to fabricate the first pass filament. The first pass filaments were arranged in the same die with a central carbon core for making the space for spongy bone. Burning out and sintering processes were performed to remove the binder and lubricant. The microstructure channel diameter was researched around $300{\mu}m$. Microstructure analysis was carried out by OM, SEM, and $\mu$-CT. Compressive strength was investigated for the artificial bone. Some preliminary bio-compatibility test was evaluated.

  • PDF

Endobronchial Ultrasound in Early Lung Cancer (초기 폐암에서 기관지 초음파 내시경의 임상적 유용성)

  • Park, Jinkyeong;Hwangbo, Bin
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2011
  • Endobronchial ultrasound (EBUS), which enables visualization of lesions beyond the bronchus, broadens the fields of bronchoscopy. Two types of ultrasound, radial and linear, are used for bronchoscopy. Radial EBUS is performed by inserting an ultrasound mini-probe through the working channel of a flexible bronchoscope. Evaluation of the depth of invasion of early endobronchial lung cancers using radial EBUS is useful in deciding endobronchial treatment. A central tumor limited to within the cartilaginous layer is a good indication for endobronchial photodynamic therapy. EBUS-guide sheath (GS) technique is a sampling method assisted by localization of peripheral lesions using EBUS. The diagnostic yield of EBUS-GS method is higher than that of conventional transbronchial biopsy. High diagnostic values of EBSU-GS method are reported even in small (${\leq}2cm$) peripheral tumors. Linear EBUS is used for endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA). EBUS-TBNA has high diagnostic yields in mediastinal staging of lung cancer even in patients having radiologically early stage lung cancers with normal CT or PET findings in the mediastinum. EBUS is a valuable method in evaluating early endobronchial tumors and peripheral small lung cancers and as well as in mediastinal staging.

  • PDF

Flow Characteristics in a Human Airway model for Oral Cancer Surgery by PIV Experiment and Numerical Simulation (PIV 측정 및 수치해석을 이용한 구강암 수술에 따른 기도 형상 내 유동 특성)

  • Hong, Hyeonji;An, Se Hyeon;Seo, Heerim;Song, Jae Min;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.115-122
    • /
    • 2021
  • Oral cancer surgery typically consists of resection of lesion, neck dissection and reconstruction, and it has an impact on the position of hyoid bone. Therefore, morphological change of airway can occur since the geometric parameter of airway is correlated with the hyoid bone. Airflow is affected by geometry of the airway. In this study, flow characteristics were compared between pre- and post-surgery models by both particle image velocimetry (PIV) and numerical simulation. 3D model of upper airway was reconstructed based on CT data. Velocity is accelerated by the reduced channel area, and vortex and recirculation region are observed in pre- and post-surgery models. For the post-surgery model, high pressure distribution is developed by significantly decreased hydraulic diameter, and the longitudinal flow stream is also interrupted.

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

The 3-Dimensional Analysis of the Efficacy of a Belly-Board Device for the Displacement of Small Bowel During Pelvic Irradiation (골반강 방사선치료 중 소장의 이동을 위한 벨리보드의 효과에 대한 3차원적 분석)

  • Lee, Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.271-279
    • /
    • 2008
  • Purpose: To evaluate the efficacy of a belly-board device (BBD) in reducing the volume of small bowel during four-field pelvic irradiation. Materials and Methods: Twenty-two cancer patients (14 uterine cervical cancer, 6 rectal cancer, and 2 endometrial cancer) scheduled to receive pelvic irradiation were selected for this study. Two sets of CT images were taken with and without the belly-board device using the Siemens 16 channel CT scanner. All patients were set in the prone position. The CT images were transferred to a treatment planning system for dose calculation and volume measurements. The external surfaces of small bowel and the bladder were contoured on all CT scans and the 4-pelvic fields were added. The dose-volume-histogram of the bladder and small bowel, with and without the BBD, were plotted and analyzed. Results: In all patients, the total small bowel volume included in the irradiated fields was reduced when the BBD was used. The mean volume reduction was 35% (range, $1{\sim}79%$) and was statistically significant (p<0.001). The reduction in small bowel volume receiving $10{\sim}100%$ of the prescribed dose was statistically significant when the BBD was used in all cases. Almost no change in the total bladder volume involved was observed in the field (<8 cc, p=0.762). However, the bladder volume receiving 90% of the prescribed dose was 100% in 15/22 patients (68%) and $90{\sim}99%$ in 7/22 patients (32%) with the BBD. In comparison, the bladder volume receiving 90% of the prescribed dose was 100% in 10/22 patients (45%), $90{\sim}99%$ in 7/22 patients (32%), and $80{\sim}89%$ in 5/22 patients (23%) without the BBD. When the BBD was used, an increase in the bladder volume receiving a high dose range was observed Conclusion: This study shows that the use of a BBD for the treatment of cancer in the pelvic area significantly improves small bowel sparing. However, since the BBD pushed the bladder into the treatment field, the bladder volume receiving the high dose could increase. Therefore it is recommended to be considerate in using the BBD when bladder damage is of concern.

Characteristics of Fat Tissue According to the Anatomical Regions of the Body: Computed Tomographic and Histological Findings (신체 부위에 따른 지방조직의 특성: 컴퓨터단층촬영 및 조직학적 소견)

  • Shin, Dong-Woo;Son, Dae-Gu;Park, Mu-Shik;Kim, Jun-Hyung;Han, Ki-Hwan
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.535-546
    • /
    • 2010
  • Purpose: The subcutaneous fat tissue is separated into 2 layers by the subcutaneous fascia: the superficial and deep fat layers. The two fat layers have different structures according to the body regions. The purpose of this study is to evaluate the distribution and pattern of the two fat layers in the human body by computed tomography (CT) and histological analysis according to age, sex, anatomical region, and body mass index (BMI). Methods: This study included 200 males and 200 females who underwent 64-channel dynamic CT in our hospital. The patients were divided into 5 groups according to 10 years of their ages separately in either male or female gender. The thickness of the superficial and deep fat layers was measured in the abdominal, pelvic, and femoral regions, and we analyzed the values. Statistical analyses were performed using SPSS software. The $3{\times}3$-cm whole fat layers were harvested from the same sites of 3 cadavers for histological examination, and one cadaver was dissected for gross evaluation. Results: The total thickness of subcutaneous fat tissue was greater in females than in males, and the ratio of the superficial fat layer to the whole fat layer was higher in females. The superficial fat layer became thinner with increasing age in males. As BMI increased, the total fat layer became thicker, and the superficial fat layer became thicker than the deep fat layer. On histological examination, the superficial fat layer had small adipose lobules and showed a densely distributed pattern in the abdominal region, whereas in the femoral region, it had large adipose lobules and showed a sparsely distributed pattern. There were no significant differences in the histological findings of the deep fat layer between the 3 body regions. Conclusion: Significant differences in histological findings of the two fat layers were found in relation to age, sex, anatomical region, and BMI. The superficial fat layer became thinner with increasing age in males, but it was constant in females. As BMI increased, the total thickness of subcutaneous fat tissue became greater, and the superficial fat layer became thicker than the deep fat layer. Our measurements can be used to understand the characteristics of the fat layers in relation to age, sex, anatomical region, and BMI.