• Title/Summary/Keyword: CT Industry

Search Result 118, Processing Time 0.022 seconds

The Evaluation of Spatial Resolution of Stationary-gantry Sparse-view CT Security-screening System (고정형(Stationary-gantry) 희소뷰(Sparse-view) CT 보안검색시스템의 공간분해능 평가)

  • YoungJo Kim;KwangYoon Choi;Chunhe Zheng;HyeongKyu Park
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.377-384
    • /
    • 2023
  • In this study, the image quality assessment, especially spatial resolution evaluation, for Sparse-view CT reconstructed images was performed. The main goal of the experiment is to evaluate Modulation Transfer Function by using American Standard Method for Measurement of Computed Tomography System Performance(ASTM E1695-95) which uses the edge test object. To compare with the ASTM method, a different method, the radial-type edge profile, to measure MTF using the edge method also performed. Both approaches were tested on the same image acquired by the stationary-gantry sparse-view CT security-screening system using cylindrical test phantom manufactured in accordance with ANSI 42.45. Both of the spatial resolutions at 10% modulation are 0.195, 0.203lp pixel-1, respectively. The method implemented by ASTM E1695-95 showed higher reliability and had a relatively more accurate spatial resolution result than the radial-type edge profile method.

A Study of CT Development Applied Elastic Epoxy (탄성형 에폭시를 사용한 변류기 개발에 관한 연구)

  • Lee, K.W.;Lee, K.Y.;Chang, Y.M.;Choi, Y.S.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.197-199
    • /
    • 2004
  • In this paper, we studied a accuracy for CT using elastic epoxy. According to industry development, the quality where also the electric material is various is demanded. Insulation material is widely used because epoxy is superior to electrical and mechanical property. Until now, the possibility where the crack will occur is high because epoxy used to electrical products had high hardness. If thermal expansion is different of two material, contraction of epoxy heavily transformed turns ratio of CT. Elastic epoxy absorbed in expansion and contraction of substance material by temperature. So we could design more exacted CT. We had elastic test of elastic epoxy and made CT using elastic epoxy. At the result, We obtained turns ratio of within 4% superior to existing CT.

  • PDF

Evaluation of Images Depending on an Attenuation Correction in a Brain PET/CT Scan

  • Choi, Eun-Jin;Jeong, Mon-Taeg;Dong, Kyung-Rae;Kwak, Jong-Gil;Choi, Ji-Won;Ryu, Jae-Kwang
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.267-276
    • /
    • 2018
  • A Hoffman 3D Brain Phantom was used to evaluate two PET/CT scanners, BIO_40 and D_690, according to the radiation dose of CT (low, medium and high) at a fixed kilo-voltage-peak (kVp) with the tube current(mA) varied in 17~20 stages(Bio_40 PET/CT scanner: the tube voltage was fixed to 120 kVp, the effective tube current(mAs) was increased from 33 mAs to 190 mAs in 10 mAs increments, D_690 PET/CT scanner: the tube voltage was fixed to 140 kVp, tube current(mA) was increased from 10 mAs to 200 mAs in 10 mAs increments). After obtaining the PET image, an attenuation correction was conducted based on the attenuation map, which led to an analysis of the difference in the image. First, the ratio of white to gray matter for each scanner was examined by comparing the coefficient of variation (CV) depending on the average ratio. In addition, a blind test was carried out to evaluate the image. According to the study results, the BIO_40 and D_690 scanners showed a <1% change in CV value due to the tube current conversion. The change in the coefficients of white and gray matter showed that the Z value was negative for both scanners, indicating that the coefficient of gray matter was higher than that of white matter. Moreover, no difference was observed when the images were compared in a blind test.

Disease Testing in Pelvic Pain Patients: Comparison between Ultrasound and Computed Tomography Imaging (골반통 환자의 질환 검사: 초음파와 컴퓨터단층촬영 간의 비교)

  • EunHoe Goo
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.385-390
    • /
    • 2023
  • The uterus, one of women's reproductive organs, is also closely related to women's health. Among them, hemorrhagic luteal cysts, one of the causes of pelvic pain that women often experience, were observed through CT and ultrasound, and the quality of images was evaluated through quantitative and qualitative evaluations. This study sought to find out whether the test method is more helpful to patients during CT and ultrasound. This study was conducted on 15 adolescent women and 15 adult women(21.31±3.45 average age). The equipment used for filming used EC3-10X (3~10 MHZ) and Philips Mx8000 iCT 256 among Endocavity Probes among Ecube Platinum. After setting a constant ROI on the cyst and the interface as a quantitative analysis method, SNR and CNR values were measured on a 5-point scale based on image quality, lesion clarity, image distortion, clarity of the interface, and motion artifacts (p<0.05). Independent t-test and Mann Whiteny U were performed, and the statistical program used was noted when SPSS (Version 22.0 for windows software package, Chicago, IL, USA) was statistically less than 0.05. Comparing the SNR and CNR values for this experiment, it can be seen that the SNR value was higher in the case of CT images(p<0.05). As a result of the qualitative evaluation, the quality of the image, the clarity of the lesion, the distortion of the image, the clarity of the interface, and the clarity of the boundary were measured on a 5-point scale based on the movement artifact. Comparing each score, CT images scored higher with a finer difference than ultrasound images(p<0.05). In conclusion, both test methods showed excellent results in finding the patient's lesions. However, in quantitative and qualitative evaluations, CT produced higher results in detecting lesions than ultrasound. However, for cyst tests that require continuous observation, ultrasonography, a non-invasive method that is advantageous for patients, will be clinically useful. Therefore, observing the patient's lesions by appropriately distributing these two test methods will provide optimal diagnostic information. These results will be useful for providing clinical basic data and educational materials to CT and US users in the future.

Antitumor Activities of Sea Staghorn (Codium fragile) against CT-26 Cells

  • Kim, Kil-Nam;Kim, Soo-Hyun;Kim, Won-Suk;Kang, Sung-Myung;Lee, Ki-Wan;Lee, Wook-Jae;Park, Soo-Yeong;Kim, Se-Kwon;Jeon, You-Jin
    • Food Science and Biotechnology
    • /
    • v.17 no.5
    • /
    • pp.976-982
    • /
    • 2008
  • The 10 species of marine green algae was collected from Jejudo(Island) in Korea. Methanolic and aqueous extracts were prepared and screened for inhibition activities against tumor cell growth. Of the tested samples, the sea staghorn (Codium fragile) aqueous extract (CFAE) showed the highest activity on CT-26 cell growth. Therefore, CFAE was selected for further experiments and the possibility to induce apoptosis by the CFAE was investigated. Flow cytometric analysis revealed that it dose-dependently increased apoptotic cells with hypodiploid DNA contents in CT-26 cell line. These results indicated that CFAE can suppress the growth of CT-26 cells through apoptosis. The CFAE decreased the protein expression of anti-apoptotic Bcl-xL and led to the activation of caspase-3 and -7. A crude polysaccharide was separated from CFAE and it mainly constituted with 61.2% galactose and 30.5% arabinose as analyzed by high performance liquid chromatography (HPLC).

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Current Transformer Using Epoxy (에폭시를 사용한 변류기)

  • Park, Chul-Woong;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.199-202
    • /
    • 2008
  • In this paper, we studied a accuracy for CT using elastic epoxy. According to industry development, the quality where also the electric material is various is demanded. Insulation material is widely used because epoxy is superior to electrical and mechanical property. Until now, the possibility where the crack will occur is high because epoxy used to electrical products had high hardness. If thermal expansion is different of two material, contraction of epoxy heavily transformed turns ratio of CT Elastic epoxy absorbed in expansion and contraction of substance material by temperature. So we could design more exacted CT We had elastic test of elastic epoxy and made CT using elastic epoxy. At the result, We obtained turns ratio of within 4% superior to existing CT.

  • PDF

Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry (유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교)

  • Park, Tae Seok;Han, Jun Hee;Jo, Seung Yeon;Lee, Eun Lim;Jo, Kyu Won;Kweon, Dae Cheol
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

The Interaction of Nonionic Surfactant with Iodine in the Presence of $Ca^{2+}$ ($Ca^{2+}$ 존재하에서 비이온성 계면활성제와 요오드와의 상호작용)

  • Park Jeoung-Sun;Kwon Oh-Yun;Paek U-Hyon
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.1
    • /
    • pp.36-42
    • /
    • 1993
  • In the presence of $Ca^{2+}$ ion, the charge transfer (CT) interaction of nonionic surfactants, $nonylphenol-(ethylene oxide)_n\;[NP-(EO)_n; n = 11, 40, 100]$ with iodine in aqueous solution were investigated by UV-visible spectrophotometer. The characteristics of spectra depended on the concentration of $Ca^{2+}$ ion and the number of EO unit. Above CMC, the intensity of the CT band by the addition of $Ca^{2+}$ ion for the $NP-(EO)_{11}$ and $NP-(EO)_{40}$ increased and then decreased, while for the $NP-(EO)_{100}$ continuously increased. The increase in the intensity of CT band were attributed to the compactness of micelle in the presence of $Ca^{2+}$ ion. These phenomena may be explained by the fact that the linear ethylene oxide (EO) chain, to be free configuration in aqueous solution, could form a pseudo-crown ether structures capable of forming complexes with $Ca^{2+}$ ion.

  • PDF

Anti-tumor and Anti-inflammatory Effects of Ecklonia cava in CT26 Tumor-bearing BALB/cKorl Syngeneic Mice (CT26 고형암을 내포하는 BALB/cKorl Syngeneic 마우스에서 Ecklonia cava의 항암효과 및 항염증효과)

  • Yu Jeong Roh;Ji Eun Kim;You Jeong Jin;Ayun Seol;Hee Jin Song;Tae Ryeol Kim;Kyeong Seon Min;Eun Seo Park;Ki Ho Park;Dae Youn Hwang
    • Journal of Life Science
    • /
    • v.33 no.11
    • /
    • pp.887-896
    • /
    • 2023
  • The inflammatory response have been considered as one of important targets for cancer treatment because they play a key role during all steps of tumor development including initiation, promotion, malignant conversion and progression. To investigate the anti-inflammatory response during anti-tumor activity of an aqueous extracts of Ecklonia cava (AEC), alterations on the distribution of mast cells and the expression of inducible nitric oxide synthase (iNOS) and cyclooxygenase-2 (COX-2), nuclear factor (NF)-κB, inflammasome compositional protein and inflammatory cytokines were examined in CT26 colon tumor-bearing BALB/cKorl syngeneic mice after administrating AEC for five weeks. After treatment of AEC, total weight of tumor and necrotic region of tumor section were significantly decreased compared to vehicle treated group. The number of infiltered mast cells was higher in AEC treated group than vehicle treated group, while the expression levels of COX-2 and iNOS were decreased in AEC treated group. Also, similar decrease pattern were detected in the expression levels of NF-κB, NLR family pyrin domain containing 3 (NLRP3), apoptosis-associated speck-like protein containing a caspase recruitment domain (ASC) and caspase-1 (Cas-1) after AEC treatment although the decrease rate was varied. Furthermore, the mRNA expressions of three inflammatory cytokines including tumor necrosis factor-α (TNF-α), interleukin-1α (IL-1α) and interleukin-6 (IL-6) were remarkably decreased in AEC treated group compared to vehicle treated group. These results suggest that inhibition of inflammatory response may be tightly associated with anti-tumor activity of AEC in CT26 colon tumor-bearing BALB/cKorl syngeneic mice.