• 제목/요약/키워드: CT Examination Time

검색결과 135건 처리시간 0.028초

18F-FDG PET-CT 검사에서 췌장암, 췌장염, 정상 췌장에 대한 최대 표준섭취계수의 임상적 기준 설정 (Clinical Reference of the Maximum Standardized Uptake Values to the Pancreatic Cancer, Pancreatitis and Normal Pancreas in the 18F-FDG PET-CT)

  • 이재승;권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권2호
    • /
    • pp.80-86
    • /
    • 2018
  • The aim of this study were to establish the clinical references and guidelines for the maximum standardized uptake ($SUV_{max}$) value of pancreatic cancer, pancreatitis, and normal pancreas in $^{18}F-FDG$ PET-CT examinations for pancreatic disease. For this purpose, we performed the statistical analysis on the descriptive statistics, percentiles and inter quartiles range (IQR), normal distribution, and using the probability density function for pancreatic cancer, pancreatitis, and normal pancreas. As a result, the clinical reference of $SUV_{max}$ for the pancreatic cancer, pancreatitis, and normal pancreas was more than 3.45, 1.91 to 2.62, and less than 1.91, respectively. Also, optimal cut-off value for applying the dual time point PET-CT examination was determined to be 2.62. The results of this study are summarized as follows: first, we suggests the clinical reference and guideline for the pancreatic cancer, pancreatitis, and normal pancreas, and second, suggests a scientific approach to improve diagnostic accuracy of pancreatic disease by deviating from an approximate experience approach.

CT 영상에서 폐 결절 분할을 위한 경계 및 역 어텐션 기법 (Boundary and Reverse Attention Module for Lung Nodule Segmentation in CT Images)

  • 황경연;지예원;윤학영;이상준
    • 대한임베디드공학회논문지
    • /
    • 제17권5호
    • /
    • pp.265-272
    • /
    • 2022
  • As the risk of lung cancer has increased, early-stage detection and treatment of cancers have received a lot of attention. Among various medical imaging approaches, computer tomography (CT) has been widely utilized to examine the size and growth rate of lung nodules. However, the process of manual examination is a time-consuming task, and it causes physical and mental fatigue for medical professionals. Recently, many computer-aided diagnostic methods have been proposed to reduce the workload of medical professionals. In recent studies, encoder-decoder architectures have shown reliable performances in medical image segmentation, and it is adopted to predict lesion candidates. However, localizing nodules in lung CT images is a challenging problem due to the extremely small sizes and unstructured shapes of nodules. To solve these problems, we utilize atrous spatial pyramid pooling (ASPP) to minimize the loss of information for a general U-Net baseline model to extract rich representations from various receptive fields. Moreover, we propose mixed-up attention mechanism of reverse, boundary and convolutional block attention module (CBAM) to improve the accuracy of segmentation small scale of various shapes. The performance of the proposed model is compared with several previous attention mechanisms on the LIDC-IDRI dataset, and experimental results demonstrate that reverse, boundary, and CBAM (RB-CBAM) are effective in the segmentation of small nodules.

Stereotactic Radiation Therapy for Nasal Carcinoma with Cribriform Plate Destruction in Three Dogs: A Serial CT Study

  • Soyon An;Gunha Hwang;Moonyeong Choi;Chan Huh;Young-Min Yoon;Hee Chun Lee;Tae Sung Hwang
    • 한국임상수의학회지
    • /
    • 제40권2호
    • /
    • pp.139-146
    • /
    • 2023
  • Three dogs were referred with epistaxis and facial deformity. Computed tomography (CT) scan identified masses in the bilateral nasal cavity with soft tissue attenuation and contrast enhancement. These masses had caused adjacent bones lysis, especially lysis of cribriform plate that extended to the intracranial region. Base on histopathology and CT imaging results, tumors were diagnosed as nasal carcinomas at stage 4. Three dogs were treated with stereotactic radiation therapy (SRT). These dogs received 30-35 Gy from 3-5 daily treatments (7-10 Gy per treatment). The sizes of tumors decreased the most on follow-up CT images at one month after treatment. Recurrence was confirmed between 3 and 5 months after completing SRT. The survival time of dogs treated with SRT were 110, 190, and 210 days, respectively. This study confirmed that SRT could treat canine nasal carcinomas with cribriform plate lysis without causing serious radiation toxicities. Follow-up CT examination is considered at 1 month and 3 to 6 months after SRT to accurately evaluate the prognosis and the timing of recurrence.

미세수술을 이용한 하지의 재건시 삼차원 컴퓨터 혈관조영술의 유용성 (Usefullness with 3D CT Angiography in Microsurgical Reconstruction)

  • 성용덕;김효헌
    • Archives of Plastic Surgery
    • /
    • 제33권2호
    • /
    • pp.175-180
    • /
    • 2006
  • Preoperative angiography is frequently used in the planning of microsurgical reconstruction for identification of vascular abnormality that influence the planning of operation. But, recently 3D CT angiography is considered as new technique that can provide detailed information about vascular anatomy as well as soft and bony tissue without the risks of invasive angiography. 3D CT angiograms were performed in 19 patients before microsurgical reconstruction for the lower extremity and hand between May of 2003 and Oct of 2004. Sixteen of the studies were of the donor site and all of 19 studies were of the recipient site. No complications were found from the 3D CT angiograms. In one case of the bone exposed open wound, the injury of anterior tibial artery was identified and the zone of injury was adequately demonstrated. With the improvement in quality of CT imaging, 3D CT angiograms may provide a favorable alternative to invasive angiography. It is capable of providing high-resolution, three dimensional vascular imaging without the need for arterial puncture and prolonged post-procedure observation. The relation among blood vessels, bones, and soft tissue is well demonstrated in 3D CT angiogram. Also The acquisition time and examination cost were considerably lower in comparison with invasive angiography. In conclusion, this study demonstrates that 3D CT angiography may provide accurate, safe, and cost-effective preoperative imaging. The 3D CT angiography with relatively low morbidity, low cost, ease of image acquisition can have an broader role in microsurgical reconstructive surgery.

18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과 (The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning)

  • 차상영;조용귀;이용기;송종남;최남길
    • 한국방사선학회논문지
    • /
    • 제10권4호
    • /
    • pp.255-261
    • /
    • 2016
  • PET/CT 촬영에서 정량분석에 영향을 주는 다양한 인자 중 현재 상품화된 CT 조영제와 MRI 조영제의 종류별 각 성분의 특성에 따른 SUV의 변화를 비교 분석하고자 하였다. 실험장비는 Discovery 690 PET/CT(Ge)와 NEMA NU2-1994 PET phantom를 이용하였고, 팬텀에 증류수 2/3를 채워 넣은 후 방사성동위원소(18F-FDG 37 MBq)와 각각의 CT와 MRI 조영제를 순차적으로 주입하여 팬텀을 고르게 교반하고 다시 증류수를 가득 채운 후 기포가 생기지 않게 하였다. 방출스캔은 FDG 또는 FDG와 혼합한 조영제를 넣고 40분에 15분 동안 스캔하였으며, 투과스캔은 CT로 관전압 120 kVp, 관전류 40 mA, 회전시간 0.5 sec, 단면두께 3.27 mm, DFOV 30 cm의 조건으로 스캔하였다. 분석방법으로 정량분석은 각각 10, 15, 20, 25, 30번째 slice에서 region of interest (ROI)를 설정하여 각각 SUVmean, SUVmax를 구하였다. 결과적으로 순수 FDG 영상과 비교에서 MRI 조영제를 혼합한 3종류의 영상 모두에서 SUVmean가 높게 측정되었으나 통계적 유의성은 없었고, SUVmax 에서는 유의한 결과를 얻었다. 또한 4종류의 CT 조영제 영상은 SUVmean, SUVmax 모두 유의한 결과를 얻었다. PET/CT는 영상의 정확도를 위해 감쇠 보정은 다양한 방법으로 시행되고 있지만 CT와 MRI 조영제는 감쇠보정 시 영상의 왜곡에 의한 진단적 가치를 저하시킬 수 있다. 이러한 이유로 진료 당일 여러 종류의 검사를 시행하기 전 반드시 선행되어야 할 검사를 선별하여 서로 영향을 주지 않도록 함으로서 고객에게 차별화된 양질의 의료서비스를 제공해야 한다.

Clinical Application of Transcatheter Arterial Chemoembolization Combined with Synchronous C-arm Cone-Beam CT Guided Radiofrequency Ablation in treatment of Large Hepatocellular Carcinoma

  • Wang, Zhi-Jun;Wang, Mao-Qiang;Duan, Feng;Song, Peng;Liu, Feng-Yong;Wang, Yan;Yan, Jie-Yu;Li, Kai;Yuan, Kai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권3호
    • /
    • pp.1649-1654
    • /
    • 2013
  • Objective: This work aimed to evaluate the safety and clinical efficacy of transcatheter arterial chemoembolization (TACE) combined with c-arm cone-beam CT guided synchronous radiofrequency ablation (RFA) in treatment of large hepatocellular carcinoma (HCC). Methods: 21 patients with large HCC were studied from January 2010 to March 2012. TACE combined with synchronous C-arm cone-beam CT guided RFA were performed on a total of 25 lesions. Conventional imaging examination (CEUS, enhanced CT or MRI) and AFP detection were regularly conducted to evaluate the technical success rate of combined treatment, complications, treatment response, time without disease recurrence and survival rate. Results: The technical success rate of combined treatment was 100%, without any significant complication. After 1 month, there were 19 cases with complete response and 2 cases with partial response, with an complete response rate of 90.4% (19/21) and a clinical effective rate of 100% (21/21). The complete response rates of single nodular lesions (100%, 17/17) was significantly higher than that of multiple nodular lesions (50%, 2/4) (P<0. 05). During 2 to 28 months of follow-up, in 19 cases with complete response, the average time without disease recurrence was $10.8{\pm}6$ months. The total survival rates of 6, 12 and 18 months in 21 patients were 100%, respectively. Conclusion: TACE combined with synchronous C-arm CT guided RFA is safe and effective for treatment of large HCC. The treatment efficacy for single nodular lesion is better than that for multiple nodular lesions.

18F-FDG와 99mTcO4-를 이용한 당일 검사 시 상호 영향에 대한 Phantom 연구 (Phantom Study of the Mutual Influences Between 18F-FDG and 99mTcO4- on the Same Day)

  • 함준철;박민수;반영각;임한상;김재삼
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.68-72
    • /
    • 2014
  • 핵의학 검사는 반감기로 인한 동위원소의 잔류로 당일에 두 가지 검사를 시행하는데 어려움이 있다. 본 연구는 $^{18}F$-FDG와 $^{99m}TcO_4{^-}$의 상호 영향을 연구함으로써 당일 검사를 진행할 경우 고려될 사항에 대해 알아보고자 한다. NEMA-1994 Phantom을 이용하여 세 번의 실험을 진행했다. 첫 실험은 $^{99m}TcO_4{^-}$을 HOT과 BKG 비 4:1로 만들어 GE사의 INFINIA 장비로 SPECT를 시행하였고, BKG 영역에 $^{18}F$-FDG 37 MBq을 주입 후 동일 조건으로 60분에 1회씩 13회 Scan 했다. 두 번째는 $^{18}F$-FDG를 HOT과 BKG 비 4:1 로 만들어 GE사의 PET/CT Discovery 600 에서 Scan 하였고, BKG 영역에 $^{99m}TcO_4{^-}$을 148 MBq 주입 후 동일 조건으로 60분에 1회씩 6회 Scan 했다. 마지막 실험은 $^{18}F$-FDG를 HOT과 BKG 비 4 : 1로 만들고 1 Bed Scan 후 $^{99m}TcO_4{^-}$을 148 MBq 및 296 MBq씩 증가 시키며 같은 조건으로 1 Bed Scan했다. HOT과 BKG 영역의 비, CNR 혹은 SNR 그리고 총 획득 계수를 측정 후 비교 했다. $^{18}F$-FDG는 SPECT 시행 시 비율 및 CNR에 유의한 차이를 보였다(p>0.05). $^{99m}TcO_4{^-}$는 PET/CT 시행 시 비율 및 SNR이 유의한 차이를 보이지 않았다(p<0.05). $^{99m}TcO_4{^-}$이 PET/CT 검사의 Total Counts를 감소시킨다는 결과를 획득했다. PET/CT 검사를 한 경우 12시간 까지도 $^{99m}TcO_4{^-}$을 이용한 검사에 영향을 미칠 수 있으며, $^{99m}TcO_4{^-}$를 먼저 시행한 경우에는 PET/CT 검사에 SUV 및 SNR에 영향은 없지만 검출 효율을 감소시켰다. 당일 검사 시에는 $^{99m}TcO_4{^-}$을 이용한 검사를 먼저 진행하고 PET/CT의 검사 시간을 늘려 검출 효율을 보완하는 방법을 권장하고자 한다.

  • PDF

Detection of Recurrence in a Surveillance Program for Epithelial Ovarian Cancer

  • Suprasert, Prapaporn;Chalapati, Wadwilai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7193-7196
    • /
    • 2013
  • Ovarian cancer patients need a surveillance program for the detection of tumor progression after completion of treatment. The methods generally consist of history taking, physical examination, tumor marker monitoring and imaging. However, the details of recurrence detection with each method are not well defined. To clarify this issue, ovarian cancer patients who achieved complete or partial responses and developed tumor progression at the follow up time between January 2004 and December 2010 in University Hospital Chiang Mai, Thailand, were reviewed. Clinical data, CA 125 level and imaging results at the tumor progression time were recorded and analyzed. There were 144 ovarian cancer patients meeting the inclusion criteria with the mean age of 51 years and 62.5% of them were in an advanced stage. Complete response was achieved in 89 patients (61.8%) after primary treatment. The median progression free survival and overall survival were 15.5 months and 37.5 months, respectively. Abnormal symptoms presented in 49.3% of the studied patients and 59.7% developed physical examination abnormalities. In addition, CA 125 was elevated in 89.6% while in 74.3% of tumor progression was identified by CT-scan. Short treatment time period and a high level of CA 125 were significant independent prognostic factors in these patients. In conclusion, careful history taking, physical examination and monitoring of CA 125 levels are important methods for tumor progression detection in a surveillance program for epithelial ovarian cancer patients.

Barium 조영제의 농도 차이가 PET 검사에 미치는 영향 (Influence on PET Exam Caused by Density Differences of Barium-sulfate Contrast Media)

  • 최우준;신상기;남기표;박순기
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose: The evaluation of SUV (Standardized Uptake Values) for quantitative analysis in PET exam is the most significant. In PET exam, we make attenuation correction images by using $^{68}Ge$, $^{137}Cs$ or CT data. At this time, a distorted attenuation map affects quantitative analysis. After the exam using barium-sulfate and high density of barium contrast make attenuation map distorted. And then it brings bed influences on SUV. The aim of this study is to verify the relationship between high density barium-sulfate and SUV in PET exam. Materials and Methods By using $^{18}F$-FDG, we made barium-sulfate powder, density of 0, 1.5, 3, 5, 10 and 15% respectively and acquired PET and PET/CT images per each density. And we examined SUV variations from PET and PET/CT images according to differences of barium's density. Moreover, we finally calculated SUV causing variations in HU (Hounsfield Units) values to justify whether the differences of barium density bring any changes in PET/CT exam. Results: From PET images acquired from transmission scan with $^{68}Ge$, we got SUV figures from 6.46 to 6.8 in barium density between 0 to 15 percent. On the other hand, In PET images acquired from Tx scan that using CT, SUV was 6.77 to 23.73, derived from the same barium density. And CT HU values range from 29 to 2004. Conclusion: PET images from Tx data using $^{68}Ge$ weren't affected by barium density and had no differences in SUV. But in the PET/CT images using CT Tx data, there's considerable variations in HU and SUV values according to a difference of barium density in HU values. To perform a precise examination, barium sulfate should be removed from a human body before performing a PET exam.

  • PDF

응급의료서비스를 통해 내원한 뇌출혈 환자의 주취 유무에 따른 KTAS Level과 검사시간의 차이 (Emergency department triage and medical process according to alcohol intoxication in brain hemorrhage)

  • 김용준;이경열
    • 한국응급구조학회지
    • /
    • 제24권2호
    • /
    • pp.99-109
    • /
    • 2020
  • Purpose: Alcohol intoxication is frequently observed in patients with brain hemorrhage. The purpose of this study was to determine whether intoxication affects the Korean Triage and Acuity Stage (KTAS) level and the emergency medical process in emergency departments. Methods: This study was a retrospective observational study enrolled 253 brain hemorrhage patients (47 of those intoxicated) who visited the emergency medical center on public EMS ambulance from January. 1, 2017 to April, 30, 2019. Data were collected through the electronic medical record (EMR). KTAS level and time to computerized tomography (CT) were compared to evaluate whether inebriation affects care and examination processes. All data were analyzed using SPSS program. Results: Of the 47 patients intoxicated patients, 85.1% were male, and 74.5% accompanied by trauma. Initial KTAS level showed significant differences (77.2%; p=.000) when the level 3,4 was not drunk. The average time taken from triage to CT scans showed a significant difference of 24.81±23.72 (min) when the drunken state was not 58.38±56.54 (min)(p=.000). Conclusion: In patients with brain hemorrhage admitted to ED from public EMS, undertriage and delay after initial assessment were detected in inebriated patients. Careful initial evaluation and prompt medical response should be considered for patients transported by EMS.