• Title/Summary/Keyword: CT Examination Time

Search Result 135, Processing Time 0.025 seconds

Design and Implementation of Web-based Problem Management System for CT Radiological Technologist Education (CT 전문방사선사 교육을 위한 웹기반 문항관리 시스템의 설계 및 구현)

  • Shin Yong-Won;Koo Bong-Oh;Shim Choon-Bo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.1
    • /
    • pp.27-35
    • /
    • 2005
  • Recently, despite of the rapid progress of information technology in the medical and health fields, the development and management of problem sets about medical and education contents related with radiological technologist has been still achieved by manual and offline method using document editor. In this study, the unique web-based problem management system is designed and implemented. That system can efficiently manage and present various kind of problem set about integrated education and personal license without time and space limitations in order to improve the efficiency of supplementary training and to obtain the professional license for CT radiological technologist. The proposed system is composed of administration module and user module. The former supports several functions such as problem creation, problem categorization, user management, and adjustment of leveled assessment. On the other hand, the latter functions examination applying , problem retrieval, personal score retrieval, and interpretation viewing, and so on. In addition, our system is expected as a useful and practical system which provides problem interpretation and analysis of score results after applying for the examination. It can elevate ability of learning and information interchange among them preparing for CT professional radiological technologist licensing examination

  • PDF

Single Centre Experience on Decision Making for Mechanical Thrombectomy Based on Single-Phase CT Angiography by Including NCCT and Maximum Intensity Projection Images - A Comparison with Magnetic Resonance Imaging after Non-Contrast CT

  • Kim, Myeong Soo;Kim, Gi Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.2
    • /
    • pp.188-201
    • /
    • 2020
  • Objective : The purpose of this study was to suggest that computed tomography angiography (CTA) is valuable as the only preliminary examination for mechanical thrombectomy (MT). MT after single examination of CTA including noncontrast computed tomography (NCCT) and maximum intensity projection (MIP) improves door-to-puncture time as well as results in favorable outcomes. Methods : A total of 157 patients who underwent MT at Dong Kang Medical Center from April 2015 to March 2019 were divided into two groups based on the examination performed prior to MT : CTA group who underwent CTA with NCCT and MIP, and NCCT+magnetic resonance image (MRi) group who underwent MRI including perfusion images after NCCT. In the two groups, time to CTA imaging or NCCT+MRi imaging after symptom onset, and time to arterial puncture and reperfusion were characterized as time-related outcomes. The evaluation of vascular recanalization after MT was defined as a modified thrombolysis in cerebral infarction (mTICI) scale. National Institutes of Health Stroke Scale (NIHSS) was assessed at the time of the visit to the emergency room and modified Rankin Scale (mRS) was assessed after 90 days. Results : Typically, there were 34 patients in the CTA group and 33 patients in the NCCT+MRi group. A significantly shorter delay for door-to-puncture time was observed (mean, 86±22.1 vs. 176±47.5 minutes; <0.01). Also, a significantly shorter door-to-imege time in the CTA group was observed (mean, 13±6.8 vs. 93±30.8 minutes; p<0.01). Moreover, a significantly shorter onset-to-puncture time was observed (mean, 195±128.0 vs. 314±157.6 minutes; p<0.01). Reperfusion result of mTICI ≥2b was 100% (34/34) in the CTA group and 94% (31/33) in the NCCT+MRi group, and mTICI 3 in 74% (25/34) in the CTA group and 73% (24/33) in the NCCT+MRi group. Favorable functional outcomes (mRS score ≤2 at 90 days) were 68% (23/34) in the CTA group and 60% (20/33) in the NCCT+MRi group. Conclusion : A single-phase CTA including NCCT and MIP images was performed as a single preliminary examination, which led to a reduction in the time of the procedure and resulted in good results of prognosis. Consequently, it is concluded that this method is of sufficient value as the only preliminary examination for decision making.

A Study on the Reduction of Patient's Exposure Dose according to the Arrival Time of Contrast Media in Abdominal CT Scan using Bolus Tracking Technique (Bolus tracking 기법을 이용한 복부 CT 검사 시 조영제 도달시간에 따른 환자 피폭선량 감소에 관한 연구)

  • Lee, Seung yong;Han, Dong kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • The purpose of this study is to find out the factors that affect the patient's exposure dose during the abdominal CT scan using the bolus tracking technique, and reducing the radiation exposure to the patient during the abdominal CT scan using the bolus tracking technique by adjusting the delay time according to the corresponding factor. The experiment was divided into two parts, and the first experiment was conducted with 300 patients There were 188 males and 112 females, and their average age was 58±12.18(19~85). In the second experiment, 150 subjects (100 males and 50 females) who were undergoing their follow-up examination among the first experiment subjects, and the difference in dose before and after was compared by applying the delay time according to the influencing factor. As a result of the first experiment, there was a relationship between the arrival time of the contrast media and the heart rate, and it was found that the arrival time decreased as the heart rate increased for both men and women. As a result of the second experiment, the average dose of CTDIvol and DLP before/after applying the delay time according to the heart rate decreased 4.98 mGy and 5.33 mGy·cm in the male group, and 3.54 mGy and 3.88 mGy·cm in the female group. By applying proper delay time according to the patient's heart rate during abdominal CT scan with the bolus tracking technique, the radiation exposure dose of the patient can be reduced.

A Study on the Improvement for Medical Service Using Video Promotion Materials for PET/CT Scans (PET/CT 검사에서 동영상 홍보물을 통한 의료서비스 향상에 관한 연구)

  • Kim, Woo Hyun;Kim, Jung Seon;Ko, Hyun Soo;Sung, Ji Hye;Lee, Jeoung Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.30-35
    • /
    • 2013
  • Purpose: One of the current services, providing information to the patients and their guardians by using promotion materials induces positive responses and contributes to the improvement of the hospital reliability. Therefore, the objective of this study is to evaluate the effectiveness of audio visual materials, one of the means of promotion, as a way to give accurate medical information to resolve patient's curiosity about purpose and procedure of their examination and deplete complains about waiting which attributes negative effect to service quality assessment. Materials and Methods: 60 patients(mean age $53.97{\pm}12.24$, male : female = 26 : 34) who had $^{18}F-FDG PET/CT$ scan from July 2012 to August 2012 in Seoul Asan Medical Center were referred to the study. All of the patients having PET/CT scan were asked to watch an informative video material before the injection of radiopharmaceutical ($^{18}F-FDG$) and to fill in a questionnaire. Results: As a result of analyzing the contents of questionnaire, 52% of 60 patients had PET/CT scan for the first time and 72.4% of the patients read the PET/CT guidebook offered from their outpatient department or inpatient wards before their scan. After we searched the level of previous knowledge of the purpose and method of PET/CT scan, the patients answered 25.1% "know well", 34% "not sure", 40.9% "don't know" respectively. And 84.7% of the patients answered that watching the PET/CT guide video before the injection helps understanding what exam they were having and 15.3% of the patients did not. For the question asking ever the patients have experienced using our homepage or smart phone QR code to see the guide video before they visit out PET center, only 3.3% of them answered "yes". Lastly, the patients answered 60.1% "yes", 31.4% "so so" and 8.5% "no" respectively for the question asking whether watching the video makes the patients to fill the waiting time short. Conclusion: It is found that understanding of objective and method of the PET/CT scan and level of satisfaction was improved after the patients watched the guide video whether they had PET/CT scan before and read the PET/CT guidebook or not. Also, watching the video was effective for the reduction of perceptible waiting time. But while displaying the PET/CT guide video is useful for providing information about the scan and shortening the waiting time as one of the medical service, utilization of service was actually very poor because of the passive promotion and indifference of the patients about their examination. Therefore, from now on, it is necessary to construct the healthcare system which can be offered to more patients through the active promotion.

  • PDF

Evaluation of Usefulness of CT Angiography in the Lower Extremity using Heart Rate (심박동 수를 활용한 Lower Extremity CT Angiography 검사의 유용성 평가)

  • Sung-Sik, Kim;Ho-Sung, Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.53-62
    • /
    • 2023
  • The purpose of this study is to find an optimized imaging technique and evaluate its usefulness by comparing and analyzing the difference in contrast enhancement of lower extremity artery according to the patient's heart rate during lower extremity Computed Tomography Angiography examination. From January 2022 to August 22nd, 139 outpatients who visited Ajou University Hospital and underwent lower extremity angio CT examination were targeted. According to the heart rate, the groups were divided into four groups: A(HR ≤65), B(65 < HR < 80), C(80≤ HR). In addition, among patients with a heart rate of 65 or less, the heart rate was considered, and the scan was divided into D, E, F group with a delay time. The time of arrival of contrast medium and the average value of contrast enhancement were compared and analyzed. As a result of quantitative evaluation, B and C groups with a heart rate of more than 65 times had better HU values in the popliteal artery than A group (HR ≤ 65), and D group showed better HU improvement effects compared to A group (p<0.001). The comparative analysis with other groups was insignificant. The difference in heart rate affected the angiographic intensity of the lower extremities artery. Therefore, it is effective to apply the appropriate test timing for each patient by using the heart rate during the lower extremity angio CT Scan.

A Study on the Radiation Exposure Dose of Brain Perfusion CT Examination a Phantom (Phantom을 이용한 뇌 관류 CT검사에서 방사선 피폭선량에 관한 연구)

  • Jung, Hong-Rynag;Kim, Ki-Jeong;Mo, Eun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.287-294
    • /
    • 2015
  • The purpose of this study, was Let's examine the exposure dose at the time of cerebral blood flow CT scan of acute ischemic stroke patients. In particular, long-term high doses of radiation sensitive organs and we Measured using phantom and a glass dosimeter. Apply the existing protocol suggested by the manufacturer (fixed time delay technique) and the proposed new convergence protocol (bolus tracking technique), reporting to measure the dose, dose reduction was to prepare the way. Results up to 39.8% as compared to the existing protocols in a new suggested convergence protocol, a minimum of 5.8% was long-term dose is reduced. Test dose of $CDTI_{vol}$ and DLP values decreased 25%, respectively, were measured at less than recommended dose. Try checking the protocol set out in the existing based on the analysis result of the above, by applying the proposed new convergence protocol by reducing the dose would have to contribute to improved public health. It is believed to be research continues to find the optimum protocol in the other tests.

A Study on the Indirect Radiation Exposure of the Medical Personnel Who is Responsible for Patient Safety in CT Examination (전산화단층촬영검사 시 검사실 내에 위치할 수 있는 의료인의 간접 피폭선량에 대한 연구)

  • Choi, Min-Hyeok;Jang, Ji-Sung;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.105-111
    • /
    • 2019
  • A medical personnel could be placed beside a patient together in CT room to do Ambu-bag for a seriously ill patients or emergency patient. At this time, the medical personnel can be exposed indirect radiation unnecessarily. In this case, it is necessary to recognize indirect radiation dose levels and methods to reduce them using actual clinical CT protocols such as Chest, Abdomen, and Brain CT. We researched surface radiation dose with or without radiation protectors such as apron and goggles according to different distances far from gantry using two different CT scanners (Fixed MDCT and mobile CT). As a result, for Chest, Abdomen, and Brain CT with Fixed MDCT, indirect radiation dose on thorax portion were 0.047, 0.089, 0.034 mSv without apron. Also, those with apron were 0.007, 0.012, 0.006 mSv. In case of mobile CT, it was 0.014 mSv without apron and 0.005 mSv with apron. By using protectors and increasing the distance, we could reduce it to 97%. Systematic management is necessary based on the measured data in order to minimize radiation damage due to indirect exposure dose.

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.

A Study on Perception by Examinees of the Health Promotion Center Institutions about Exposure to Radioactivity (건강검진센터에 내원한 환자의 방사선피폭에 대한인지도 조사)

  • Yeo, Jin-Dong;Jeon, Byeong-Kyu
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.457-468
    • /
    • 2016
  • The purpose of this study was to investigate factors of perception by inpatients of the Medical Examination institutions about exposure to radioactivity at the time of radioactive examination, providing basic information for making educational materials aimed to change their perception. Most of those patients, 72.0% responded that CT was a type of radioactive examination bringing highest exposure to radiosensitivity. Most of the subjects, 63.5% said that a body part most vulnerable to exposure to radiosensitivity was the genital gland at the time of radiosensitivity examination. And most of the participants, or 29.0% responded that they obtained information about radiation from TVs or newspapers. Among the surveyed patients, men were higher in scores for factors of the perception of radiation such as recognition of radiation, harmfulness of radiation, psychological state at the time of radioactive examination, prevention of exposure to radioactivity and necessity of radiation that women were, with statistically significant differences between the two groups. These findings suggest that it is urgently needed to develop an education program which helps patients better perceive exposure to radioactivity and that radiologists should be very careful to reduce the does of that exposure. If patients better perceive radiation, they would be less anxious and less exposed to radioactivity when receiving the radioactive examination.

The Safety Assessment of Surrounding Dose on Nuclear Medicine Test by Use The F-18 FDG (F-18 FDG를 이용한 핵의학 검사에서 주변 선량의 안전성 평가)

  • Kwak, Byung-Joon;Ji, Tae-Jeong;Min, Byung-In
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.157-162
    • /
    • 2009
  • Radioactive medicines are used a lot owing to the increase of a PET-CT examination using glucose metabolism useful for the early diagnosis of diseases. Therefore, the spatial dose that is generated from patients and their surroundings causes the patients' guardians and health professional to be exposed to radiation. However, they get unnecessarily exposed to radiation because medical institutions lack in space for isolation and recognition of the examination. This research intended to examine the spatial dose rates by measuring the dose emitted from the patient for 48 hours to whom F-18 FDG was administered. The spatial dose rates that were measured 100cm away from the patient's body after F-18 FDG was injected were $65.88{\mu}$Sv/hr at 60-minute point, $45.13{\mu}$Sv/hr at 90-minute point, $9.88{\mu}$Sv/hr at 6-hour point, and $1.24{\mu}$Sv/hr at 12-hour point. When the dose that the guardian and health professional got was converted into the annual(240-day working) accumulative dose, it was examined that the guardian received 81.56 mSv/yr and health professional received 49.36mSv/yr. In addition, the result has revealed that the dose that the patient received from one time of PET-CT examination was 3.75mSv/yr, which is 1.5 times more when compared with the annual natural radiation exposure dose.